Search NASA⌕ Search

SEARCH · Search NASA

Results for “repeat sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Simple Transient Thermal Test Assembly for Insulation Materials

A simple transient thermal test was developed for evaluating the thermal performance of high-temperature flexible insulation materials in atmospheric pressure air. The test setup was inspired by the test assembly used for evaluating the performance of fire shelters and fire protective clothing. The heating source used was a burner supplied with propane gas that can generate relatively uniform heating over a wide area. The ratio of the in-plane width to thickness of the insulation test sample in the test assembly was selected to be greater than ten so that the heat transfer in the center of the test assembly was nearly one-dimensional. A rigid, thin Inconel plate was used as the septum plate directly exposed to the flame to provide a relatively uniform, known-temperature boundary condition for the test assembly, and to prevent convective heat transfer through the test insulation from the burner. The test sample, flexible alumina paper insulation, was placed between the Inconel plate and a thin titanium witness plate. The overall assembly was further insulated using a combination of rigid and flexible ceramic insulations to minimize heat losses from the periphery of the test assembly. Thermocouples installed on the septum and witness plates and inside the insulation test sample provided temperature measurements at various locations. For the evaluation tests, the Inconel septum plate reached temperatures between 780°C and 850°C for tests with flame exposure durations of 120 sec to 300 sec. The measured temperatures for various tests with similar flame exposure times were repeatable. A one-dimensional numerical heat transfer model of the test assembly was developed. The close agreement between measured and predicted temperatures on the titanium witness plate and inside the insulation test sample indicated that this test may provide a one-dimensional thermal testing capability for evaluation of thermal performance of similar insulations.

Daryabeigi, Kamran↗

Cardiopulmonary Inflammatory Response to Meteorite Dust Exposures - Implications for Human Health on Earth and Beyond

This year marks the 50th anniversary of Apollo 11, the first time humans set foot on the Moon. The Apollo missions not only help answer questions related to our solar system, they also highlight many hazards associated with human space travel. One major concern is the effect of extraterrestrial dust on astronaut health. In an effort to expand upon previous work indicating lunar dust is respirable and reactive, the authors initiated an extensive study evaluating the role of a particulate’s innate geochemical features (e.g., bulk chemistry, internal composition, morphology, size, and reactivity) in generating adverse toxicological responses in vitro and in vivo. To allow for a broader planetary and geochemical assessment, seven samples were evaluated: six meteorites from either the Moon, Mars, or Asteroid 4 Vesta and a terrestrial basalt analogue. Even with the relatively small geochemical differences (all samples basaltic in nature), significant difference in cardiopulmonary inflammatory markers developed in both single exposure and multiple exposure studies. More specifically: 1) the single exposure studies reveal relationships between toxicity and a meteorite sample’s origin, its pre-ejected state (weathered versus un-weathered), and geochemical features (e.g. bulk iron content) and 2) multiple exposure studies reveal a correlation with particle derived reactive oxygen species (ROS) formation and neutrophil infiltration. Extended human exploration will further increase the probability of inadvertent and repeated exposures to extraterrestrial dusts. This comprehensive dataset allows for not only the toxicological evaluation of extraterrestrial materials but also clarifies important correlations between geochemistry and health. The utilization of an array of extraterrestrial samples from Moon, Mars, and asteroid 4Vesta will enable the development of a geochemical based toxicological hazard model that can be used for: 1) mission planning, 2) rapid risk assessment in cases of unexpected exposures, and 3) evaluation of the efficacy of various in situ techniques in gauging surface dust toxicity. Furthermore, by better understanding the importance of geochemical features on exposure related health outcomes in space, it is possible to better understand of the deleterious nature of dust exposure on Earth.

Harrington, A. D.↗

Evaluation of a standard test method for total hemispherical emittance of surfaces from 293K to 1673K

Emittance tests were made on samples of Rene' 41, Haynes 188, and Inconel 625 superalloy metals in an evaluation of a standard test method for determining total hemispherical emittances of surfaces from 293 K to 1673 K. The intent of this evaluation was to address any problems encountered, check repeatability of measured emittances, and gain experience in use of the test procedure. Five test specimens were fabricated to prescribe test dimensions and surfaces cleaned of oil and residue. Three of these specimens were without oxidized surfaces and two with oxidized surfaces. The oxidized specimens were Rene' 41 and Haynes 188. The tests were conducted in a vacuum where the samples were resistance-heated to various temperature levels ranging from 503 K to 1293 K. The calculated results for emittance, in the worst case, were repeatable to a maximum spread to + or - 4% from the mean of five sets of plotted data for each specimen.

Compton, E. C.↗

Determination of Local Densities in Accreted Ice Samples Using X-Rays and Digital Imaging

At the NASA Lewis Research Center's Icing Research Tunnel ice shapes, similar to those which develop in-flight icing conditions, were formed on an airfoil. Under cold room conditions these experimental samples were carefully removed from the airfoil, sliced into thin sections, and x-rayed. The resulting microradiographs were developed and the film digitized using a high resolution scanner to extract fine detail in the radiographs. A procedure was devised to calibrate the scanner and to maintain repeatability during the experiment. The techniques of image acquisition and analysis provide accurate local density measurements and reveal the internal characteristics of the accreted ice with greater detail. This paper will discuss the methodology by which these samples were prepared with emphasis on the digital imaging techniques.

Broughton, Howard↗

Incipient fault detection study for advanced spacecraft systems

A feasibility study to investigate the application of vibration monitoring to the rotating machinery of planned NASA advanced spacecraft components is described. Factors investigated include: (1) special problems associated with small, high RPM machines; (2) application across multiple component types; (3) microgravity; (4) multiple fault types; (5) eight different analysis techniques including signature analysis, high frequency demodulation, cepstrum, clustering, amplitude analysis, and pattern recognition are compared; and (6) small sample statistical analysis is used to compare performance by computation of probability of detection and false alarm for an ensemble of repeated baseline and faulted tests. Both detection and classification performance are quantified. Vibration monitoring is shown to be an effective means of detecting the most important problem types for small, high RPM fans and pumps typical of those planned for the advanced spacecraft. A preliminary monitoring system design and implementation plan is presented.

Milner, G. Martin↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

Compact, Non-Pneumatic Rock-Powder Samplers

Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

Sherrit, Stewart↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Microbiology and Crew Medical Events on the International Space Station

The closed environment of the International Space Station (ISS) creates an ideal environment for microbial growth. Previous studies have identified the ubiquitous nature of microorganisms throughout the space station environment. To ensure safety of the crew, microbial monitoring of air and surface within ISS began in December 2000 and continues to be monitored on a quarterly basis. Water monitoring began in 2009 when the potable water dispenser was installed on ISS. However, it is unknown if high microbial counts are associated with inflight medical events. The microbial counts are determined for the air, surface, and water samples collected during flight operations and samples are returned to the Microbiology laboratory at the Johnson Space Center for identification. Instances of microbial counts above the established microbial limit requirements were noted and compared inflight medical events (any non-injury event such as illness, rashes, etc.) that were reported during the same calendar-quarter. Data were analyzed using repeated measures logistic regression for the forty-one US astronauts flew on ISS between 2000 and 2012. In that time frame, instances of microbial counts being above established limits were found for 10 times for air samples, 22 times for surface samples and twice for water. Seventy-eight inflight medical events were reported among the astronauts. A three times greater risk of a medical event was found when microbial samples were found to be high (OR = 3.01; p =.007). Engineering controls, crew training, and strict microbial limits have been established to mitigate the crew medical events and environmental risks. Due to the timing issues of sampling and the samples return to earth, identification of particular microorganisms causing a particular inflight medical event is difficult. Further analyses are underway.

Oubre, Cherie↗

Microbiology and Crew Medical Events on the International Space Station

The closed environment of the International Space Station (ISS) creates an ideal environment for microbial growth. Previous studies have identified the ubiquitous nature of microorganisms throughout the space station environment. To ensure safety of the crew, microbial monitoring of air and surface within ISS began in December 2000 and continues to be monitored on a quarterly basis. Water monitoring began in 2009 when the potable water dispenser was installed on ISS. However, it is unknown if high microbial counts are associated with inflight medical events. The microbial counts are determined for the air, surface, and water samples collected during flight operations and samples are returned to the Microbiology laboratory at the Johnson Space Center for identification. Instances of microbial counts above the established microbial limit requirements were noted and compared inflight medical events (any non-injury event such as illness, rashes, etc.) that were reported during the same calendar-quarter. Data were analyzed using repeated measures logistic regression for the forty-one US astronauts flew on ISS between 2000 and 2012. In that time frame, instances of microbial counts being above established limits were found for 10 times for air samples, 22 times for surface samples and twice for water. Seventy-eight inflight medical events were reported among the astronauts. A three times greater risk of a medical event was found when microbial samples were found to be high (OR = 3.01; p =.007). Engineering controls, crew training, and strict microbial limits have been established to mitigate the crew medical events and environmental risks. Due to the timing issues of sampling and the samples return to earth, identification of particular microorganisms causing a particular inflight medical event is difficult. Further analyses are underway.

Oubre, Cherie M.↗

Portable Infrared Reflectometer Designed and Manufactured for Evaluating Emittance in the Laboratory or in the Field

The optical properties of materials play a key role in spacecraft thermal control. In space, radiant heat transfer is the only mode of heat transfer that can reject heat from a spacecraft. One of the key properties for defining radiant heat transfer is emittance, a measure of how efficiently a surface can reject heat in comparison to a perfect black body emitter. Heat rejection occurs in the infrared region of the spectrum, nominally in the range of 2 to 25 mm. To calculate emittance, one obtains the reflectance over this spectral range, calculates spectral absorptance by difference, and then uses Kirchhoff s Law and the Stefan-Boltzmann equation to calculate emittance. A new portable infrared reflectometer, the SOC 400t, was designed and manufactured to evaluate the emittance of surfaces and coatings in the laboratory or in the field. It was developed by Surface Optics Corporation under a contract with the NASA Glenn Research Center at Lewis Field to replace the Center s aging Gier-Dunkle DB-100 infrared reflectometer. The specifications for the new instrument include a wavelength range of 2 to 25 mm; reflectance repeatability of +/-1 percent; self-calibrating, near-normal spectral reflectance measurements; a full scan measurement time of 3.5 min, a sample size of 1.27 cm (0.5 in.); a spectral resolution selectable from 4, 8, 16, or 32/cm; and optical property characterization utilizing an automatic integration to calculate total emittance in a selectable temperature range.

Jaworske, Donald A.↗

Development and Characterization of Improved NiTiPd High-Temperature Shape-Memory Alloys by Solid-Solution Strengthening and Thermomechanical Processing

The need for compact, solid-state actuation systems for use in the aerospace, automotive, and other transportation industries is currently motivating research in high-temperature shape-memory alloys (HTSMA) with transformation temperatures greater than 100 C. One of the basic high-temperature alloys investigated to fill this need is Ni(19.5)Ti(50.5)Pd30. Initial testing has indicated that this alloy, while having acceptable work characteristics, suffers from significant permanent deformation (or ratcheting) during thermal cycling under load. In an effort to overcome this deficiency, various solid-solution alloying and thermomechanical processing schemes were investigated. Solid-solution strengthening was achieved by substituting 5at% gold or platinum for palladium in Ni(19.5)Ti(50.5)Pd30, the so-called baseline alloy, to strengthen the martensite and austenite phases against slip processes and improve thermomechanical behavior. Tensile properties, work behavior, and dimensional stability during repeated thermal cycling under load for the ternary and quaternary alloys were compared. The relative difference in yield strength between the martensite and austenite phases and the dimensional stability of the alloy were improved by the quaternary additions, while work output was only minimally impacted. The three alloys were also thermomechanically processed by cycling repeatedly through the transformation range under a constant stress. This so-called training process dramatically improved the dimensional stability in these samples and also recovered the slight decrease in work output caused by quaternary alloying. An added benefit of the solid-solution strengthening was maintenance of enhanced dimensional stability of the trained material to higher temperatures compared to the baseline alloy, providing a greater measure of over-temperature capability.

Bigelow, Glen↗

O-6 Optical Property Degradation of the Hubble Space Telescope's Wide Field Camera-2 Pick Off Mirror

Degradation in the performance of optical components can be greatly affected by exposure to the space environment. Many factors can contribute to such degradation including surface contaminants; outgassing; vacuum, UV, and atomic oxygen exposure; temperature cycling; or combinations of parameters. In-situ observations give important clues to degradation processes, but there are relatively few opportunities to correlate those observations with post-flight ground analyses. The return of instruments from the Hubble Space Telescope (HST) after its final servicing mission in May 2009 provided such an opportunity. Among the instruments returned from HST was the Wide-Field Planetary Camera-2 (WFPC-2), which had been exposed to the space environment for 16 years. This work focuses on the identifying the sources of degradation in the performance of the Pick-off mirror (POM) from WFPC-2. Techniques including surface reflectivity measurements, spectroscopic ellipsometry, FTIR (and ATR-FTIR) analyses, SEM/EDS, X-ray photoelectron spectroscopy (XPS) with and without ion milling, and wet and dry physical surface sampling were performed. Destructive and contact analyses took place only after completion of the non-destructive measurements. Spectroscopic ellipsometry was then repeated to determine the extent of contaminant removal by the destructive techniques, providing insight into the nature and extent of polymerization of the contaminant layer.

McNamara, Karen M.↗

Development of a Rotating Rake Array for Boundary-Layer-Ingesting Fan-Stage Measurements

The recent Boundary-Layer-Ingesting Inlet/Distortion Tolerant Fan wind tunnel experiment at NASA Glenn Research Center's 8-foot by 6-foot supersonic wind tunnel examined the performance of a novel inlet and fan stage that was designed to ingest the vehicle boundary layer in order to take advantage of a predicted overall propulsive efficiency benefit. A key piece of the experiment's instrumentation was a pair of rotating rake arrays located upstream and downstream of the fan stage. This paper examines the development of these rake arrays. Pre-test numerical solutions were sampled to determine placement and spacing for rake pressure and temperature probes. The effects of probe spacing and survey density on the repeatability of survey measurements was examined. These data were then used to estimate measurement uncertainty for the adiabatic efficiency.

Wolter, John D.↗

Development of a Rotating Rake Array for Boundary-Layer-Ingesting Fan-Stage Measurements

The recent Boundary-Layer-Ingesting Inlet/Distortion Tolerant Fan wind tunnel experiment at NASA Glenn Research Center's 8- by 6-foot Supersonic Wind Tunnel (SWT) examined the performance of a novel inlet and fan stage that was designed to ingest the vehicle boundary layer in order to take advantage of a predicted overall propulsive efficiency benefit. A key piece of the experiment's instrumentation was a pair of rotating rake arrays located upstream and downstream of the fan stage. This paper examines the development of these rake arrays. Pre-test numerical solutions were sampled to determine placement and spacing for rake pressure and temperature probes. The effects of probe spacing and survey density on the repeatability of survey measurements was examined. These data were then used to estimate measurement uncertainty for the adiabatic efficiency.

turbomachinery↗

Observation of Hydrogen Isotope Diffusion Through Thin Palladium-Silver Samples

Observations from several experimental scenarios by various research groups found that releasing deuterium gas from hydrided palladium (Pd) metal can result in unexplained temperature increases. This heating is possible evidence of heat generation in what is ostensibly an endothermic process. Creating a method for identifying and repeating this unusual scenario is beneficial for understanding the occurrence of such temperature increases. It is suspected that x-ray radiation and significant deuterium concentrations may contribute to such reactions. The work, described here, attempted to determine if x-ray stimulation, combined with diffusion of hydrogen or deuterium gas, can cause anomalous nuclear behavior in thin Pd-silver (Ag) and titanium (Ti)-carbide coated Pd-Ag sample disks.

hydrogen↗

Predicting Spacecraft Trajectories

Calculations include drag, nonsphericity, and other perturbations. Artificial Satellite Analysis Program (ASAP) is general orbit-prediction program that incorporates sufficient orbit-modeling accuracy for mission design, maneuver analysis, and mission planning. Suitable for studying planetary orbit missions with spacecraft trajectories of exploratory (mapping) nature. Sample data included for study of drift cycle of geosynchronous station, strategy for mapping Venus by radar, frozen orbit about Mars, and repeat-ground-trace orbit. ASAP written in FORTRAN 77.

Kwok, J.↗