Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Crystal structure of domain of unknown function 507 (DUF507) reveals a new protein fold

The crystal structure of the domain of unknown function family 507 protein from Aquifex aeolicus is reported (AaDUF507, UniProt O67633, 183 residues). The structure was determined in two space groups (C222 1 and P3 2 21) at 1.9 Å resolution. The phase problem was solved by molecular replacement using an AlphaFold model as the search model. AaDUF507 is a Y-shaped α-helical protein consisting of an anti-parallel 4-helix bundle base and two helical arms that extend 30-Å from the base. The two crystal structures differ by a 25° rigid body rotation of the C-terminal arm. The tertiary structure exhibits pseudo-twofold symmetry. The structural symmetry mirrors internal sequence similarity: residues 11–57 and 102–148 are 30% identical and 53% similar with an E-value of 0.002. In one of the structures, electron density for an unknown ligand, consistent with nicotinamide or similar molecule, may indicate a functional site. Docking calculations suggest potential ligand binding hot spots in the region between the helical arms. Structure-based query of the Protein Data Bank revealed no other protein with a similar tertiary structure, leading us to propose that AaDUF507 represents a new protein fold.

36 MATERIALS SCIENCE↗

Mechanical component screening for scanner

The critical mechanical components of the scan mirror mechanism are described and their evaluation and screening procedures are discussed. A bumper/damper unit is used in the design to reverse motion of the mirror and effect scan and retrace cycles. A wear evaluation was conducted on the bumper impact surfaces that established nylon 6-10 as an acceptable material. The elastomeric dampers were subjected to thermal vacuum tests for condensables and outgassing as well as parametric life tests. The flexure pivots that support the mirror were tested to establish a curve of stress plotted as a function of cycles to failure for rotational operation. The pivots met the life requirement of 150,000,000 cycles at a + or - 2.9 deg amplitude during fatigue testing. Screening procedures were established for dampers and flexure pivots to obtain flight quality components.

Olson, J. L.↗

Upper Atmosphere Research Satellite Jitter Study

The study objectives are to analyze in-flight jitter; evaluate different models of the Upper Atmosphere Research Satellite (UARS); and determine jitter prediction accuracy such that adequate (but not excessive) design margins will assume future mission success. The topics are presented in viewgraph form and include the following: UARS chronology; UARS disturbance experiment; microwave limb sounder antenna and mirror time profiles; solar array drive disturbance; roll and yaw jitter correlation with solar array position; solar array rotation; UARS disturbance summary; concept for reduction of jitter effect; jitter reduction using window scheduling; and highlights/lessons learned.

Woodard, Stanley↗

Reduction of the one-dimensional X-ray scattering data on mirror flats at NASA/Marshall Space Flight Center

Data on the scattering of X-rays from various mirror flats obtained from different vendors. The scattering data discussed in this section is obtained by a one dimensional proportional counter at X-ray energies of 8.06, 6.4 and 2.99 keV. X-rays are generated at one end of a 312.4m long tube which is under vacuum. This long tube provides a parallel beam of X-rays which is then collimated by a slit and allowed to scatter from a pair of mirror flats at small grazing angles of incidence. The slit and mirrors assembly is placed 182.4 meters from the other end of the tube where the proportional counter detector is located. The detector is sitting on an optical table which is pivoted so that it can rotate to intercept X-rays at a range of spatial locations. The optical table pivot is located 2.78 meters in front of the detector, and has an operational angular range of 350 arc minutes. Measured from the position of the mirror, this total angular range of the data is (350) (2.78/182.4) = 5.33 arcminutes.

Williams, A. C.↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗

Performance of redundant disk array organizations in transaction processing environments

A performance evaluation is conducted for two redundant disk-array organizations in a transaction-processing environment, relative to the performance of both mirrored disk organizations and organizations using neither striping nor redundancy. The proposed parity-striping alternative to striping with rotated parity is shown to furnish rapid recovery from failure at the same low storage cost without interleaving the data over multiple disks. Both noncached systems and systems using a nonvolatile cache as the controller are considered.

Mourad, Antoine N.↗

Cryogenic System for Interferometric Measurement of Dimensional Changes at 40 K: Design and Performance

This report describes the facility, experimental methods, characterizations, and uncertainty analysis of the Cryo Distortion Measurement Facility (CDMF) at the Goddard Space Flight Center (GSFC). This facility is designed to measure thermal distortions of structural elements as the temperature is lowered from 320K to below 40 K over multiple cycles, and is capable of unattended running and data logging. The first measurement is to be the change in length and any bending of composite tubes with Invar end-fittings. The CDMF includes a chamber that is efficiently cooled with two cryo-coolers (one single-stage and one two-stage) rather than with liquid cryogens. Five optical ports incorporate sapphire radiation shields - transparent to the interferometer - on each of two shrouds and a fused silica vacuum-port window. The change in length of composite tubes is monitored continuously with displacement-measuring interferometers; and the rotations, bending, and twisting are measured intermittently with theodolites and a surface-figure interferometer. Nickel-coated invar mirrors and attachment mechanisms were developed and qualified by test in the CDMF. The uncertainty in measurement of length change of 0.4 m tubes is currently estimated at 0.9 micrometers.

Blake, Peter↗

Applying the SOFIA Coordinate System to the HIRMES Instrument

The High-resolution Mid-infrared Spectrometer (HIRMES) will be in-flight aboard the Stratospheric Observatory for Infrared Astronomy (SOFIA) in late 2019, which will allow for observations of the structure and evolution of protoplanetary disks. SOFIA has a different coordinate system from the system being used to build HIRMES and needs to be defined and applied to HIRMES. This is necessary because the first mirror, which is aiming the incoming light onto the slit wheel by allowing for tip and tilt adjustments, cannot rotate. Thus, the SOFIA coordinate system allows for this additional degree of freedom and allows for the slit wheel to be in line with the telescope. Using a laser radar, multiple measurements around the instrument were taken of tooling balls, which quantified an uncertainty with the measurements. Also, a laser radar was used to scan the entirety of the instrument. The center of the front flange was determined using the measurements and scans of the instrument, which was used to determine the origin of the SOFIA coordinate system and its uncertainty. By knowing the center of the front flange, an off-center, rotated coordinate system was created, matching the mechanics' schematics for the system. Going forward, this coordinate system will allow for continued alignment of the instrument in preparation for flight and for accurate measurements when aboard SOFIA.

Wraback, Elizabeth↗

A Dual Linear/Circular Polarized Wideband Flat Panel Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Circular polarized (CP) electromagnetic waves are preferred for space-to-space and space-to-ground satellite communications (SATCOM). CubeSats with 6U sizes (1U represents a 10 cm x 10 cm x 10 cm), that will rotate together with the Moon as it orbits Earth require high gain CP antenna systems to maintain reliable communication links. Here, we have designed an 8x8 dual linear and dual circularly polarized phased array antenna (PAA) aperture that offers 22-28 GHz bandwidth, with maximum gain of 23 dBic, and beam scanning capability of ±50o with acceptable axial ratio over all scan angles. A stacked patch topology is selected to achieve wide impedance bandwidth. Each driven patch has two via feed point locations that are connected to grounded coplanar waveguide (CPW) feed structures. By utilizing phase shifters from the Anokiwave RFICs (AWMF-0165) employed for the beamforming network (BFN), we have generated both dual linear polarization and dual circular polarization in each patch. Each driven and parasitic patch is innovatively shaped to achieve excellent isolation between two feed points which, in turn, leads to low cross polarization, high efficiency and good axial ratio over the entire bandwidth. Each chip has eight outputs which feed one 2x2 sub-array consisting of four dual linear or dual circularly polarized driven patches, simultaneously. Each 2x2 sub-array of the 8x8 array are sequentially rotated which improves axial ratio performance when the antenna operates in the dual circularly polarized mode. By utilizing a mirror effect, cross-polarized fields are also improved when operated in a dual linear polarized mode. The 8x8 array aperture is simulated taking into account the effect of the multilayer printed circuit board (PCB) stack-up of the BFN and co-simulated with the power splitter outputs and chip outputs and results are compared with only passive array performance. The performance of the antenna is still excellent when non-ideal chip performances are included in the simulation analysis. The fabricated array will be tested for radiation patterns in the Antenna and Microwave Laboratory (AML) of the San Diego State University and the NASA Glenn Research Center (GRC) spherical near field chambers. The design of the 8x8 antenna array with BFN layout is shown in Fig. 1.

5G↗

The Orbitron: A crossed-field device for co-confinement of high energy ions and electrons

To explore the confinement of high-energy ions above the space charge limit, we have developed a hybrid magnetic and electrostatic confinement device called an Orbitron. The Orbitron is a crossed-field device combining aspects of magnetic mirrors, magnetrons, and orbital ion traps. Ions are confined in orbits around a high-voltage cathode with co-rotating electrons confined by a relatively weak magnetic field. Experimental and computational investigations focus on reaching ion densities above the space charge limit through the co-confinement of electrons. The experimental apparatus and suite of diagnostics are being developed to measure the critical parameters, such as plasma density, particle energy, and fusion rate for high-energy, non-thermal plasma conditions in the Orbitron. Initial results from experimental and computational efforts have revealed the need for cathode voltages on the order of 100–300 kV, leading to the development of a custom high voltage, ultra-high vacuum bushing rated for 300 kV.

Materials Science↗

Ion-Deposited Polished Coatings

Polished, dense, adherent coatings relatively free of imperfections. New process consists of using broad-beam ion source in evacuated chamber to ion-clean rotating surface that allows grazing incidence of ion beam. This sputter cleans off absorbed gases, organic contaminants, and oxides of mirror surface. In addition to cleaning, surface protrusions sputter-etched away. Process particularly adaptable to polishing of various substrates for optical or esthetic purposes.

Banks, B. A.↗

Data Analysis And Polarization Measurements With GEMS

The Gravity and Extreme Magnetism SMEX (GEMS) mission was selected by NASA for flight in 2014. GEMS will make the first sensitive survey of X-ray polarization across a wide range of source classes including black hole and neutron star binaries, AGN of different types, rotation and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect. The GEMS detectors image the charge tracks of photoelectrons produced by 2 - 10 keV X-rays. The initial direction of the photoelectron is determined by the linear polarization of the photon. We present an overview of the data analysis challenges and methods for GEMS, including procedures for producing optimally filtered images of the charge tracks and estimating their initial directions. We illustrate our methods using laboratory measurements of polarized and unpolarized X-rays with flight-like detectors as well as from simulated tracks. We also present detailed simulations exploring the statistics of polarization measurements appropriate for GEMS, and make comparisons with previous work.

Stohmayer, Tod↗

Ferrorotational domain walls revealed by electric quadrupole second harmonic generation microscopy

Domain walls are ubiquitous in materials that undergo phase transitions driven by spontaneous symmetry breaking. Domain walls in ferroics and multiferroics have received tremendous attention recently due to their emergent properties distinct from their domain counterparts—for example, their high mobility and controllability, as well as their potential applications in nanoelectronics. However, it is extremely challenging to detect, visualize, and study the ferrorotational (FR) domain walls because the FR order, in contrast to ferromagnetism and ferroelectricity, is invariant under both the spatial-inversion and the time-reversal operations and, thus, hardly couple with conventional experimental probes. Here, a FR candidate NiTi⁢O 3 is investigated by ultrasensitive electric quadrupole (EQ) second-harmonic generation rotational anisotropy (SHG RA) to probe the point symmetries of the two degenerate FR domain states, showing their relation by the vertical mirror operations that are broken below the FR critical temperature. We then visualize the real-space FR domains by scanning EQ SHG microscopy, and further, resolve the FR domain walls by revealing a suppressed SHG intensity at the domain walls. By taking local EQ SHG RA measurements, we show the restoration of the mirror symmetry at FR domain walls and prove their unconventional nonpolar nature. In conclusion, our findings not only provide a comprehensive insight into FR domain walls, but also demonstrate a unique and powerful tool for future studies on domain walls of unconventional ferroics both of which pave the way towards future manipulations and applications of FR domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic structure and exchange interactions in altermagnetic MnGeP 2 in the quasiparticle self-consistent G W approach

The quasiparticle self-consistent 𝐺⁡𝑊 method is used to study the electronic band structure, optical dielectric function, and exchange interactions in chalcopyrite, 𝐼⁢ ‾ 4 ⁢2⁢𝑑, structure MnGeP 2 . The material is found to be an antiferromagnetic semiconductor with a lowest direct gap of 2.44 eV at the Γ point and a lower indirect gap of 1.87 eV from Γ to 𝑀. The material is an altermagnet because the two magnetic atoms of opposite spin are related by a twofold rotation operation perpendicular to the main fourfold rotation inversion axis. The spin splittings along a low symmetry line like 𝑃⁢𝑁 is sizable while at k points on the diagonal mirror planes or on the twofold symmetry axes the spin splitting is zero. The exchange interactions are calculated using a linear response approach. The antiferromagnetic exchange interaction between nearest neighbors in the primitive unit cell is dominating and found to be slightly decreasing upon carrier doping but not sufficiently to change the interaction to become ferromagnetic. The bare (noninteracting) and interacting transverse spin susceptibilities, which provide interatomic site exchange interactions after averaging over the muffin-tin spheres, are calculated from the 𝐺⁡𝑊 band structure and wave functions. From these exchange interactions, the spin wave spectra are obtained along the high symmetry lines and the Néel temperature is calculated using the mean-field and Tyablikov estimations. The dielectric function and the optical absorption spectra are calculated including excitonic effects using the Bethe Salpeter equation. The exchange interactions around Mn Ge defect sites is also studied. While we find it can generate ferromagnetic interactions with neighboring spins, we did not find direct evidence of producing an overall ferromagnetic phase. First, if Mn antisites are introduced by exchanging Mn with a nearby Ge, the interactions stay largely antiferromagnetic. Second, when we add additional Mn, in other words in Mn-rich stoichiometry, the Mn Ge antisites produce a strong ferromagnetic interaction primarily with the Mn in the same basal plane but weaker ferromagnetic interaction with adjacent plane Mn. The interactions between regular lattice Mn stay antiferromagnetic as before and thus favor keeping the antiferromagnetic order along the [001] direction. Adding Mn antisites, however, does lead to a metallic band structure.

36 MATERIALS SCIENCE↗

X-Ray Polarization Capabilities of a Small Explorer Mission

X-ray polarization measurements hold great promise for studying the geometry and emission mechanisms in the strong gravitational and magnetic fields that surround black holes and neutron stars. In spite of this, the observational situation remains very limited; the last instrument dedicated to X-ray polarimetry flew decades ago on OSO-8, and the few recent measurements have been made by instruments optimized for other purposes. However, the technical capabilities to greatly advance the observational situation are in hand. Recent developments in micro-pattern gas detectors allow use of the polarization sensitivity of the photo-electric effect, which is the dominant interaction in the band above 2 keV. We present the scientific and technical requirements for an X-ray polarization observatory consistent with the scope of a NASA Small Explorer (SMEX) mission, along with a representative catalog of what the observational capabilities and expected sensitivities for the first year of operation could be. The mission is based on the technically robust design of the Gravity and Extreme Magnetism SMEX (GEMS) which completed a Phase B study and Preliminary Design Review in 2012. The GEMS mission is enabled by time projection detectors sensitive to the photo-electric effect. Prototype detectors have been designed, and provide engineering and performance data which support the mission design. The detectors are further characterized by low background, modest spectral resolution, and sub-millisecond timing resolution. The mission also incorporates high efficiency grazing incidence X-ray mirrors, design features that reduce systematic errors (identical telescopes at different azimuthal angles with respect to the look axis, and mounted on a rotating spacecraft platform), and a moderate capability to perform Target of Opportunity observations. The mission operates autonomously in a low earth, low inclination orbit with one to ten downlinks per day and one or more uplinks per week. Data and calibration products will be made available through the High Energy Astrophysics Science and Archival Research Center (HEASARC).

GEMS↗

Overview of the Digitization Workflow Post Image Acquisition of Apollo Lunar and Antarctic Meteorite Samples Using Agisoft Photoscan for the NASA 3D Astromaterials Virtual Samples Collection

The 3D Virtual Astromaterials Samples (3DVAS) collection is a multi-year funded project to create a digital database of sixty Apollo Lunar and Antarctic Meteorite samples following non-destructive documentation conservation protocols. After initial image processing, the photos are evaluated and processed using unique structure-from-motion photogrammetric techniques in a high performance modelling software designed to create a 3D model from 2D images: Agisoft Photoscan Pro. Agisoft Photoscan Pro uses image processing algorithms and techniques originating in computer vision to resolve 3D models for accurate and detailed visualization of a subject. The software provides a stepwise process that is tailored per model based on spatial and specular reflectance properties, for example. The process includes: photo alignment, creation of a dense point cloud, mesh, and finally texture. Photo alignment is dependent on model properties. The 3DVAS process requires a special rotation platform with calibrated photogrammetric targets, specific distance rotation protocols, and a contrasting background for alignment and scale accuracy. As a result of the photographic process, alignment will complete with two mirrored hemispheres that, in a sense, represent the 2D images overlapping to create a 3D model. Each dense point cloud is analyzed with provided statistical measures in a gradual selection process to eliminate outliers. The point cloud is reduced to include only data valuable to the final model. When a precise dense point cloud is achieved, a mesh and texture are applied. Each model is scaled with scale bar accuracies within 100 microns. Each sample has its own intimate process for modelling; there is no standard for the parameters required in the final creation of a high resolution model. By processing multiple samples, a skill is gained in practice to allow a close definition of the original sample and will result in the most detailed version of the sample shell. This process completes one-fifth of the 3DVAS protocol for providing accurate digital documentation. Each model shell is merged with X-ray Computed Tomography data to create a full volumetric sample. All 3DVAS data will be served on NASA's Astromaterials Acquisition and Curation website with an early subset of data available in 2019 and the 3D Virtual Astromaterials Samples Collection launch in 2020.

Thomas, Andi B.↗

Mechanical planetary compensating drive system

Drive enables two concentric output shafts to be controlled independently or rotated as a unit. Possible uses are pointing and tracking devices, rotary camera shutters with variable light control, gimbal systems with yaw and pitch movement, spectrometer mirror scanning devices, etc.

Zeiger, R. J.↗

An optical motion measuring system for laterally oscillated fatigue tests

This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.

Tripp, John S.↗