Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Local aging effects in PuB 4 : Growing inhomogeneity and slow dynamics of local field fluctuations probed by 239 Pu NMR

Plutonium-based correlated electron materials host exotic physical phenomena ranging from unconventional heavy-fermion superconductivity to topological Kondo insulating states. Self-irradiation damage can influence many properties of such radioactive materials. Structural disorder effects due to α radiation have been frequently studied using techniques such as transport, thermodynamics, and x-ray diffraction. Here, in this study, we use 239 Pu nuclear magnetic resonance (NMR) to study the long-term influence of self-damage on the lattice and local electronic structures in a single crystal of the candidate topological insulator plutonium tetraboride (PuB 4 ). We first characterize the anisotropy of the 239 Pu resonance and confirm the local axial-site symmetry inferred from previous polycrystalline measurements. Aging effects are then evaluated over the time frame of six years. We find that, though the static 239 Pu NMR spectra show a slight modulation in their shape, their field-rotation pattern reveals no change in 239 Pu local site symmetry over time, suggesting that aging has a surprisingly small impact on the spatial distribution of the static hyperfine field. Further, ligand-site 11 B NMR finds little time-dependent change in the size of electric field gradient around 11 B sites. By contrast, aging has a prominent impact on the 239 Pu NMR relaxation processes and signal intensity. Specifically, aging-induced damage manifests itself as an increase in the spin-lattice relaxation time 𝑇 1 , an increased distribution of 𝑇 1 , and a signal intensity that decreases linearly by 20% per year. An effective spin-spin relaxation time 𝑇 2,eff in the aged sample shortens drastically towards lower temperature, suggesting growth of slow fluctuations of the hyperfine field that are linked to radiation-damage-induced inhomogeneity. Our NMR study sheds light on the interplay of radiation damage and local magnetic interactions in correlated insulators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metatranscriptomic dynamics after Verticillium dahliae infection and root damage in Olea europaea

Background: The olive tree is of particular economic interest in the Mediterranean basin. Researchers have conducted several studies on one of the most devastating disorders affecting this tree, the Verticillium wilt, which causes substantial economic losses in numerous areas. We analyzed metatranscriptomic samples taken from a previous study conducted on leaves and roots of Olea europaea that were infected with Verticillium dahliae. In addition, we also analyzed mechanically damaged roots. The aim of our approach is to describe the dynamics of the root microbiome after severe perturbations. Results: Our results not only describe the dynamics of the microbial community associated with the disturbance, but also show the high complexity of these systems and explain how this can lead to a conflicting assignment of the various types of parasitism observed in a specific organism. Conclusions: Our findings indicate that this infection, although led by Verticillium, is driven not by a single species, but by a polymicrobial consortium that also includes natural endophytes of the olive tree. This community contains both biotrophic and necrotrophic organisms that alternate and live together during the infection. In addition, opportunistic organisms appear that take profit not from plant tissues, but from new emerging populations of microorganisms. Therefore, this system can be described as a complex biological system composed of different interacting communities. Notably, our work has important considerations when it comes to classifying the type of parasitism of a given species.

Verticillium dahliae↗

Associating damage nucleation and distribution with grain boundary characteristics in Ta

Here, the effect of grain boundary (GB) characteristics (as represented by misorientation angle) on its dynamic response is investigated by sampling a large set of 185 GBs in Ta bi-crystals. These GBs encompass both ordered and disordered structures – typically referred to as metastable structures, in order to reflect the diversity in the local atomic structure observed in realistic GBs. The results reveal four distinct regimes in damage distribution and failure modes as a function of misorientation angle. The above trends also correlate with the variation in the corresponding void nucleation stress.

36 MATERIALS SCIENCE↗

Characterization of radiation damage effects in high-energy neutrino target graphite using low-energy ions

Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.

43 PARTICLE ACCELERATORS↗

Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation

Structure-determination methods are needed to resolve the atomic details that underlie protein function. X-ray crystallography has provided most of our knowledge of protein structure, but is constrained by the need for large, well ordered crystals and the loss of phase information. The rapidly developing methods of serial femtosecond crystallography, micro-electron diffraction and single-particle reconstruction circumvent the first of these limitations by enabling data collection from nanocrystals or purified proteins. However, the first two methods also suffer from the phase problem, while many proteins fall below the molecular-weight threshold required for single-particle reconstruction. Cryo-electron tomography of protein nanocrystals has the potential to overcome these obstacles of mainstream structure-determination methods. Here, a data-processing scheme is presented that combines routines from X-ray crystallography and new algorithms that have been developed to solve structures from tomograms of nanocrystals. This pipeline handles image-processing challenges specific to tomographic sampling of periodic specimens and is validated using simulated crystals. The tolerance of this workflow to the effects of radiation damage is also assessed. The simulations indicate a trade-off between a wider tilt range to facilitate merging data from multiple tomograms and a smaller tilt increment to improve phase accuracy. Since phase errors, but not merging errors, can be overcome with additional data sets, these results recommend distributing the dose over a wide angular range rather than using a finer sampling interval to solve the protein structure.

59 BASIC BIOLOGICAL SCIENCES↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of preheating on tungsten damage under pulsed hydrogen plasma exposure

Preheated tungsten plate behavior under multiple pulsed hydrogen plasma irradiations in the PW-7 plasma accelerator was investigated. The preheating temperature was 973 K, which is above the ductile to brittle transition temperature (DBTT ≈ 673 K). The plate was exposed to three consecutive series of 13 plasma pulses each. Preheating sufficiently suppressed surface cracking at the early irradiation stage: after 13 pulses, cracks were rare, localized, and did not form extensive fractures. During subsequent irradiation series, the area fraction of fine cracks increased by ∼ 2% due to accumulation of dislocations around the pre-existing defects. However, their width remained nearly constant, averaging 0.2–0.3 μm, with rare cracks up to 1 μm in size. Repeated plasma exposure resulted in pronounced surface roughening associated with multiple melting cycles, crater formation and blister rupture, with roughness reaching ∼ 204 nm and a recorded sample mass loss of ∼ 2.8 mg. These results indicate that controlling tungsten preheating well above DBTT effectively reduces damage. However, the surface condition during initial irradiation significantly influences its subsequent morphological evolution. Preheating to 773 K, selected regarding the minimum DBTT value, has previously been demonstrated to be an effective approach for limiting crack growth. A further increase in temperature of approximately ∼ 1000 K did not qualitatively improve results: crack still formed and widths did not decrease. At the same time, the absence of further crack coarsening indicates that the limiting effect of preheating has been reached. Considering the increased energy costs, further increasing the preheating temperature seems unjustified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specimen sizing and remaining life sample calculations for high temperature reactor material surveillance

Advanced high-temperature nuclear reactors rely on structural components that will operate for decades under combined mechanical, thermal, and environmental loading. Materials surveillance programs are a promising strategy for managing the resulting uncertainty in long-term structural integrity by monitoring degradation in service using passively actuated mechanical test articles. Previous reports have developed a simplified, spreadsheetimplementable framework for sizing these test articles and for inferring accumulated creep damage and remaining life from ex-situ test data. This report advances that work toward practical deployment by providing a sample-problem book: a collection of worked, end-toend examples in which the ASME Section III, Division 5 design analysis of a representative high-temperature reactor component is carried through to a sized surveillance article, verified with detailed finite-element analysis, and concluded with a remaining-life assessment based on an assumed ex-situ creep-rate measurement on the retrieved specimen. The report also summarizes ongoing ANL engagement with ASTM Committee E10 on Nuclear Technology and Applications toward drafting a standard covering surveillance procedures for advanced reactors.

Barua, Bipul (ORCID:0000000247184113)↗

Nanoscale lattice strains in self-ion implanted tungsten

Developing a comprehensive understanding of the modification of material properties by neutron irradiation is important for the design of future fission and fusion power reactors. Self-ion implantation is commonly used to mimic neutron irradiation damage, however an interesting question concerns the effect of ion energy on the resulting damage structures. The reduction in the thickness of the implanted layer as the implantation energy is reduced results in the significant quandary: Does one attempt to match the primary knock-on atom energy produced during neutron irradiation or implant at a much higher energy, such that a thicker damage layer is produced? In this work, we address this question by measuring the full strain tensor for two ion implantation energies, 2 MeV and 20 MeV in self-ion implanted tungsten, a critical material for the first wall and divertor of fusion reactors. A comparison of 2 MeV and 20 MeV implanted samples is shown to result in similar lattice swelling. Multi-reflection Bragg coherent diffractive imaging (MBCDI) shows that implantation induced strain is in fact heterogeneous at the nanoscale, suggesting that there is a non-uniform distribution of defects, an observation that is not fully captured by micro-beam Laue diffraction. At the surface, MBCDI and high-resolution electron back-scattered diffraction (HR-EBSD) strain measurements agree quite well in terms of this clustering/non-uniformity of the strain distribution. However, MBCDI reveals that the heterogeneity at greater depths in the sample is much larger than at the surface. This combination of techniques provides a powerful method for detailed investigation of the microstructural damage caused by ion bombardment, and more generally of strain related phenomena in micro-volumes that are inaccessible via any other technique.

36 MATERIALS SCIENCE↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation

Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

HIDRA-MAT liquid metal droplet injector for liquid metal applications in HIDRA

A liquid metal droplet injector was explicitly designed for the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT) at the University of Illinois Urbana-Champaign to prepare liquid metal plasma-facing components (PFCs) for plasma exposure. The design goals were to create a compact, reliable, and robust design that could apply liquid metal droplets in-vacuo to a variety of samples. The injector was designed for liquid metal use, and results discussed pertain to lithium. The injector can produce lithium droplets of consistent size by utilizing programmable piston movement. Here, droplet formation data is presented for four different piston step sizes (0.125 mm, 0.25 mm, 0.5 mm, and 1 mm) at three different nozzle temperatures (185 °C, 230 °C, and 270 °C). Droplets are formed on the injector nozzle tip and a linear shift mechanism vertically translates the droplet to the substrate for application. This design prevents the droplet from inadvertently detaching off the nozzle and falling to the sample. Application of the liquid metal droplet ensures placement consistency on the substrate and helps avoid damage to components in HIDRA-MAT that should not interact with liquid metals. A description of the liquid lithium droplet creation and application results is given and provides additional insight into the cooling and oxidation of lithium droplets under vacuum conditions. A second nozzle was fabricated and demonstrated repeatability in droplet diameter creation having a variance of ±0.14 mm for droplets created from the same number of piston steps. The end-use for the injector on HIDRA-MAT is to apply liquid metals to PFCs and expose them to HIDRA's plasma with subsequent intershot in-vacuo surface analysis in HIDRA-MAT for plasma-material interaction studies.

42 ENGINEERING↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multi-physics constitutive model to predict hydrolytic aging in quasi-static behaviour of thin cross-linked polymers

The effect of hydrolytic aging on mechanical quasi-static responses of rubber-like materials, in particular, the idealized Mullins effect and permanent set have been modeled. The effect of hydrolytic damage on the mechanical integrity of the polymer matrix is modeled as the direct competition of two micro-structural phenomena (i) chain scission and (ii) reduction of cross-links. Both phenomena and their correlation were modeled and thus, the strain energy of the polymer matrix is written with respect to three independent mechanisms; i) the shrinking original matrix that has not been attacked by water, ii) conversion of the first network to a new network due to the reduction of the cross-links, and iii) energy loss from network degradation due to water attacks to polymer active agents. The proposed model satisfies the Clausius-Duhem inequality and is thus physically feasible. The model is validated with respect to sets of our experimental data and other sets available in the literature. The proposed model is based on the assumption of homogeneous diffusion and mainly relevant for thin samples. In view of its accuracy, interpret-ability, and deep insight it provides into the nature of damage accumulation, the model is a good choice for further implementation in FE applications.

42 ENGINEERING↗

Shock Damage Analysis in Serial Femtosecond Crystallography Data Collected at MHz X-ray Free-Electron Lasers

Serial femtosecond crystallography (SFX) data were recorded at the European X-ray free-electron laser facility (EuXFEL) with protein microcrystals delivered via a microscopic liquid jet. An XFEL beam striking such a jet may launch supersonic shock waves up the jet, compromising the oncoming sample. To investigate this efficiently, we employed a novel XFEL pulse pattern to nominally expose the sample to between zero and four shock waves before being probed. Analyzing hit rate, indexing rate, and resolution for diffraction data recorded at MHz pulse rates, we found no evidence of damage. Notably, however, this conclusion could only be drawn after careful identification and assimilation of numerous interrelated experimental factors, which we describe in detail. Failure to do so would have led to an erroneous conclusion. Femtosecond photography of the sample-carrying jet revealed critically different jet behavior from that of all homogeneous liquid jets studied to date in this manner.

36 MATERIALS SCIENCE↗