Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample identifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Deep Convective Cloud Calibration Sensitivity Studies in Support of Radiometrically Scaling GEO Imagers With VIIRS

The NASA CERES SYN1deg product provides the scientific community regional hourly TOA and surface broadband fluxes and clouds. For consistent geostationary (GEO) derived fluxes and clouds the GEO imagers are radiometrically scaled to the Aqua-MODIS calibration reference. The CERES project utilizes GEO and MODIS analogous channel coincident, collocated, and co-angled radiance pairs as the primary method to inter-calibrate the GEO imagers. Deep convective clouds (DCC) are bright tropical, near Lambertian, top of atmosphere pseudo invariant Earth targets that do not rely on coincident radiance pairs to radiometrically scale sensors to a common calibration reference. DCC pixels are identified by cold IR window channel brightness temperatures (BT). Successful DCC inter-calibration relies on sufficient sampling of comparable identified DCC pixels between sensors. The DCC identification thresholds, pixel resolution, local time, and geographical sampling should be consistent between sensors. Over 20 GEO imagers during the span of the CERES record have various visible and IR pixel resolutions. Unlike the MODIS and VIIRS imagers, where the visible and IR pixel resolutions are similar, the GEO visible pixel resolution is much finer than the IR pixel resolution. The study will examine the pixel resolution impact on the DCC calibration methodology. The resulting DCC calibration coefficients can be validated against the sensor pair calibration methodology. Accounting for the DCC calibration imager resolution differences will allow the CERES project to utilize the future CLARREO observations as the calibration reference for all GEO, MODIS, and VIIRS imagers across the CERES record.

Conor Haney↗

Assessing the Ability of Instantaneous Aircraft and Sonde Measurements to Characterize Climatological Means and Long-Term Trends in Tropospheric Composition

Over four decades of measurements exist that sample the 3-D composition of reactive trace gases in the troposphere from approximately weekly ozone sondes, instrumentation on civil aircraft, and individual comprehensive aircraft field campaigns. An obstacle to using these data to evaluate coupled chemistry-climate models (CCMs)the models used to project future changes in atmospheric composition and climateis that exact space-time matching between model fields and observations cannot be done, as CCMs generate their own meteorology. Evaluation typically involves averaging over large spatiotemporal regions, which may not reflect a true average due to limited or biased sampling. This averaging approach generally loses information regarding specific processes. Here we aim to identify where discrete sampling may be indicative of long-term mean conditions, using the GEOS-Chem global chemical-transport model (CTM) driven by the MERRA reanalysis to reflect historical meteorology from 2003 to 2012 at 2o by 2.5o resolution. The model has been sampled at the time and location of every ozone sonde profile available from the Would Ozone and Ultraviolet Radiation Data Centre (WOUDC), along the flight tracks of the IAGOSMOZAICCARABIC civil aircraft campaigns, as well as those from over 20 individual field campaigns performed by NASA, NOAA, DOE, NSF, NERC (UK), and DLR (Germany) during the simulation period. Focusing on ozone, carbon monoxide and reactive nitrogen species, we assess where aggregates of the in situ data are representative of the decadal mean vertical, spatial and temporal distributions that would be appropriate for evaluating CCMs. Next, we identically sample a series of parallel sensitivity simulations in which individual emission sources (e.g., lightning, biogenic VOCs, wildfires, US anthropogenic) have been removed one by one, to assess where and when the aggregated observations may offer constraints on these processes within CCMs. Lastly, we show results of an additional 31-year simulation from 1980-2010 of GEOS-Chem driven by the MACCity emissions inventory and MERRA reanalysis at 4o by 5o. We sample the model at every WOUDC sonde and flight track from MOZAIC and NASA field campaigns to evaluate which aggregate observations are statistically reflective of long-term trends over the period.

Atmospheric composition↗

Volatile products in the corrosion of Cr, Mo, Ti and four superalloys exposed to O2 containing H2O and gaseous NaCl

Cooled target collection techniques were used to study the formation of volatile products when samples of Cr, Ti, IN-738, 713C, NASA-TRW VIA and B-1900 were exposed, at elevated temperatures, to oxidizing environments containing H2O(g) and NaCl(g). Samples were heated to 1050 C in one atmosphere of slowly flowing oxygen, saturated with water at 21 C, and containing about 50 ppm NaCl(g). Volatile products were detected for all materials except B-1900 and Ti. High pressure mass spectrometric sampling was used to directly identify volatile products emanating from samples of Cr and IN-738 subject to the above environments.

Fryburg, G. C.↗

Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

Pachlhofer, Peter↗

Longitudinal Plasma Proteomic Profiling Reveals Divergent Immune Responses in Durably Cured and Relapsed Pulmonary Tuberculosis

Background: Predicting the risk of tuberculosis (TB) relapse is vital to improving treatment outcomes. Although clinical risk factors of relapse are well characterized, the biological mechanisms driving relapse, particularly host immune responses, remain poorly understood. Elucidating these mechanisms is necessary to better predict relapse risk. Methods: We conducted a longitudinal, global proteomic study on 60 participants with active pulmonary TB, half who were durably cured and half who relapsed. Plasma was collected at seven time-points: at treatment initiation (baseline), during therapy, and 52 weeks post-baseline. Samples were analyzed by high-resolution LC-MS/MS. Results: 2,418 proteins were identified across all samples, with 1,756 being differentially expressed relative to baseline (unadjusted p < 0.05). 956 proteins were differentially abundant between cured and relapsed participants. Relapsed participants showed heightened humoral immunity throughout treatment, as well as upregulated complement activation and HDL particles. Cured participants exhibited elevated recovery-related pathways by week 4, including downregulated epithelial invasion and upregulated oxygen transport. Conclusions: Heightened humoral and innate immune responses were associated with relapse, whereas recovery signatures were associated with durable cure. These findings advance our understanding of host responses to treatment and provide a basis for developing blood-based biomarkers to identify patients at increased risk of relapse.

LC-MS/MS↗

Advanced Curation: Solving Current and Future Sample Return Problems

Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon. The chemical kinetics of this reaction are poorly understood at present under the conditions of cached or curated martian samples. Among other parameters, what is the maximum temperature allowed during storage in order to preserve native martian organic compounds for analysis? What is the best means to collect headspace gases from cached martian (and other) samples? This gas will contain not only martian atmosphere but also off-gassed volatiles from the cached solids.

Fries, M.↗

Sample Handling and Processing on Mars for Future Astrobiology Missions

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

Beegle, Luther↗

Understanding the Heating Kinetics of Asteroid Ryugu By Comparison to Naturally and Experimentally Heated Meteorites

The Hayabusa2 mission visited the near-Earth Cb-type asteroid (162173) Ryugu and has returned to Earth surface material of Ryugu. Ryugu is an airless rubble pile asteroid exposed to space weathering [1]. Visible and near infrared remote observations recorded an absorption feature at 2.72 μm indicating the presence of OH– bearing hydrous components. The weak 2.72 μm feature suggested that Ryugu was once organic- and water-rich and subsequently dehydrated by a brief period of surficial heating with resemblance to “thermally metamorphosed carbonaceous chondrites”, “CI-/CM-like”, or “CY” chondrites [2, 3]. However, initial examination of the returned samples did not identify any significant heating of >150 °C [4, 5], and contrastingly, amino acid analysis of Ryugu samples suggested similarities to thermally-altered meteorites on the grounds of the predominant straight-chain n-ω-amino acid abundances [6]. In this study, we aim at addressing the nonconformal interpretations to the thermal history of Ryugu by comparing the organic composition of fresh Ryugu samples to that of chondritic meteorites that have been naturally (long-term radiogenic thermal metamorphism and short-term heating) and experimentally heated.

Q. H. S. Chan↗

Using X-Ray Computed Tomography as a Tool for Preliminary Examination Tool of Current and Future Extraterrestrial Sample Return Missions

The Astromaterials Acquisition and Curation Office at the Johnson Space Center is the past, present, and future home of all of NASA’s astromaterials sample collections. The primary goals of the curation office are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future. To this end, we perform fundamental research in advanced curation initiatives to better prepared for future sample return missions. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new sample collections, or getting new results from existing sample collections. As part of these advanced curation efforts, we have installed and are operating a Nikon XTH 320 X-ray Computed Tomography(XCT) system in the JSC curation office with four interchangeable X-ray sources, a large-area detector, and a heavy-duty stage. These instrument characteristics allow us exceptional flexibility to analyze a wide range of sample sizes, from sub-mm soil particles to rocks >10 cm in diameter. The penetrative nature of the XCT scans allows for astromaterials samples to be analyzed within sealed low-density containers (e.g., Teflon bags), preserving the pristinity of the samples. We have begun scanning of the Apollo and Antarctic Meteorite sample suites in order to non-destructively map out lithic clasts (and other features) within the samples. The data from these scans will be made available to scientists via the JSC curation website and the Astromaterials Curation Newsletter. We anticipate sample requests from these “new” lithic clasts identified in these “old” samples. We also anticipate that XCT analyses like these would be useful for future sample return missions, like the OSIRIS REx mission, as well as future sample return missions.

Zeigler, Ryan↗

Space Flown Rodent Liver RNA Sequencing Data for Machine Learning in Space Biology Research

High-throughput nucleic acid sequencing (DNA-seq, RNA-seq) has become widespread in biomedical research due to the growing availability and affordability of these assays. Data analysis has been accelerated in recent years by the adoption of artificial intelligence (AI) and machine learning (ML) techniques by biomedical researchers. In space biology research, RNAseq datasets from space-flown experimental samples are critical for characterizing the gene expression aberrations associated with exposure to spaceflight stressors. However, space biological experiments tend to be very low sample size, so identifying proper AI/ML algorithms for sequencing data analysis is an ongoing challenge since these algorithms typically require large sample size. The NASA Science Mission Directorate (SMD) has started the “Benchmark Initiative for AI/ML”, focused on creating datasets meant for three main applications: 1) scientific benchmarking, which finds the best algorithm for a specific problem; 2) application benchmarking, which measures algorithm performance against a set of parameters; and 3) system benchmarking, which evaluates performance of hardware and software architecture. These scientific benchmarks consist of an AI-ready dataset and a reference implementation on a specific scientific question. In this work, we focused on generating standardized datasets to allow the scientific community to benchmark AI/ML algorithms in the domain of space biology. We present here a standardized, AI-ready, publicly available benchmark dataset for space biology RNA-seq data as a collaboration between the NASA AI4LS (Artificial Intelligence for Life Sciences) working group. and NASA’s SMD. This dataset consists of space-flown and ground control mouse liver found in the NASA GeneLab omics database. However, to amplify the small sample number (n=112 samples) for ML purposes, we employ Gaussian noise and a generative adversarial network to extend this dataset to 6,000 synthetic samples, matching the original gene expression characteristics.

James Casaletto↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

Accumulation of microplastics in soil after long-term application of biosolids and atmospheric deposition

Land-applied biosolids can be a considerable source of microplastics in soils. Previous studies reported microplastics accumulation in soils from biosolid application, however, little is known about the contribution of atmospherically deposited microplastics to agricultural soils. In this study, we quantified and characterized microplastics in soils that have been amended with biosolids over the past 23 years. We also collected atmospheric deposition samples to determine the amount and type of plastics added to soils through atmospheric input over a period of about 2 years. Soil samples were taken from a replicated field trial where biosolids have been applied at rates of 0, 4.8, 6.9, and 9.0 t/ha every second crop. The biosolids were anaerobically digested and dewatered, and were applied by spreading onto the soil surface. Soil and atmospheric samples were extracted for microplastics by Fenton's reaction to remove organic matter followed by flotation in a zinc chloride solution to separate plastic from soil particles. Samples were analyzed for microplastics by optical microscopy and Laser Direct Infrared Imaging Analysis (LDIR). The mean number of microplastics identified from biosolids samples was 12,000 particles/kg dry biosolids. The long-term applications of biosolids to the soil led to mean plastics concentrations of 383, 500, and 361 particles/kg dry soil in the 0–10 cm depth for low, medium, and high biosolids application rates, respectively. These plastic concentrations were not significantly different from each other, but significantly higher than those found in non biosolids-amended soil (117 particles/kg dry soil). The dominant plastic types by number found in biosolids were polyurethane, followed by polyethylene, and polyamide. The most abundant plastics in soil samples were polyurethane, polyethylene terephthalate, polyamide, and polyethylene. Atmospheric deposition contributed to 15 particles/kg dry soil per year and was mainly composed of polyamide fibers. In conclusion, this study shows that long-term application of biosolids led to an accumulation of microplastics in soil, but that atmospheric deposition also contributes a considerable input of microplastics.

54 ENVIRONMENTAL SCIENCES↗

Microbiomes of frozen blood plasma samples reveal potential pathogens in wild birds and rodents

The lack of genomic data on pathogens from wildlife severely limits our ability to track transmission patterns and trace the origins of an outbreak. There are currently millions of wildlife samples in biobanks around the world, including blood samples. Blood has traditionally been viewed as a sterile environment in healthy individuals, but recent evidence suggests that this is not the case, especially for wild animals. Our goal was to determine whether frozen plasma samples can be surveyed using 16S sequencing to provide information about potential hosts for pathogens for a more complete understanding of disease systems. We sequenced blood plasma from wild North American deer mice ( Peromyscus maniculatus ) and American kestrels ( Falco sparverius ) that were cryogenically stored for 7 and 13 years, respectively, and compared two DNA extraction kits. The kestrel samples contained a very high number of reads that could not be identified to phylum compared to the mouse samples. The two kits differed in the phyla and genera that were detected, and the Zymo kit, which is optimized for plasma and serum, produced more high-quality reads for both kestrel and mouse samples. We identified several pathogenic genera, including Mycoplasma, Escherichia-Shigella , and Bartonella . Sequencing blood samples for pathogens could potentially have broad applications for identifying important reservoir hosts for pathogen transmission and provide a reduced set of species on which to follow up.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement report: Molecular composition, optical properties, and radiative effects of water-soluble organic carbon in snowpack samples from northern Xinjiang, China

Abstract. Water-soluble organic carbon (WSOC) in the cryosphere has an important impact on the biogeochemistry cycling and snow–ice surface energy balance through changes in the surface albedo. This work reports on the chemical characterization of WSOC in 28 representative snowpack samples collected across a regional area of northern Xinjiang, northwestern China. We employed multimodal analytical chemistry techniques to investigate both bulk and molecular-level composition of WSOC and its optical properties, informing the follow-up radiative forcing (RF) modeling estimates. Based on the geographic differences and proximity of emission sources, the snowpack collection sites were grouped as urban/industrial (U), rural/remote (R), and soil-influenced (S) sites, for which average WSOC total mass loadings were measured as 1968 ± 953 ng g−1 (U), 885 ± 328 ng g−1 (R), and 2082 ± 1438 ng g−1 (S), respectively. The S sites showed the higher mass absorption coefficients at 365 nm (MAC365) of 0.94 ± 0.31 m2 g−1 compared to those of U and R sites (0.39 ± 0.11 m2 g−1 and 0.38 ± 0.12 m2 g−1, respectively). Bulk composition of WSOC in the snowpack samples and its basic source apportionment was inferred from the excitation–emission matrices and the parallel factor analysis featuring relative contributions of one protein-like (PRLIS) and two humic-like (HULIS-1 and HULIS-2) components with ratios specific to each of the S, U, and R sites. Additionally, a sample from site 120 showed unique pollutant concentrations and spectroscopic features remarkably different from all other U, R, and S samples. Molecular-level characterization of WSOC using high-resolution mass spectrometry (HRMS) provided further insights into chemical differences among four types of samples (U, R, S, and 120). Specifically, many reduced-sulfur-containing species with high degrees of unsaturation and aromaticity were uniquely identified in U samples, suggesting an anthropogenic source. Aliphatic/protein-like species showed the highest contribution in R samples, indicating their biogenic origin. The WSOC components from S samples showed high oxygenation and saturation levels. A few unique CHON and CHONS compounds with high unsaturation degree and molecular weight were detected in the 120 sample, which might be anthraquinone derivatives from plant debris. Modeling of the WSOC-induced RF values showed warming effects of 0.04 to 0.59 W m−2 among different groups of sites, which contribute up to 16 % of that caused by black carbon (BC), demonstrating the important influences of WSOC on the snow energy budget.

54 ENVIRONMENTAL SCIENCES↗

Vesta in the Light of Dawn, But Without HEDS?

The derivation of HEDs from Vesta is strongly supported by Dawn data [1], and these meterorites have made interpretations of Dawn spectra much more rigorous. Compared to the Moon, where samples became available after geologic mapping, the exploration of Vesta has been backwards. But what if HEDs had not been available or identified as vestan samples? What petrologic and geochemical predictions would have been possible using Dawn data, without the benefit of HEDs?

McSween, H. Y.↗

DAHe white dwarfs from the DESI Survey

A new class of white dwarfs, dubbed DAHe, that present Zeeman-split Balmer lines in emission has recently emerged. However, the physical origin of these emission lines remains unclear. Here, we present here a sample of 21 newly identified DAHe systems and determine magnetic field strengths and (for a subset) periods that span the ranges of ≃6.5–147 MG and ≃0.4–36 h, respectively. All but four of these systems were identified from the Dark Energy Spectroscopic Instrument survey sample of more than 47 000 white dwarf candidates observed during its first year of observations. We present detailed analysis of the new DAHe WD J161634.36+541011.51 with a spin period of 95.3 min, which exhibits an anticorrelation between broad-band flux and Balmer line strength that is typically observed for this class of systems. All DAHe systems cluster closely on the Gaia Hertzsprung–Russell diagram where they represent ≃1 per cent of white dwarfs within that region. This grouping further solidifies their unexplained emergence at relatively late cooling times and we discuss this in context of current formation theories. Nine of the new DAHe systems are identifiable from Sloan Digital Sky Survey spectra of white dwarfs that had been previously classified as featureless DC-type systems. We suggest high-S/N (signal-to-noise ratios), unbiased observations of DCs as a possible route for discovering additional DAHe systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing an Optimal Ensemble Strategy for GMAO S2S Forecast System

The NASA Global Modeling and Assimilation Office (GMAO) Sub-seasonal to Seasonal (S2S) prediction system is being readied for a major upgrade. An important factor in successful extended range forecasting is the definition of the ensemble. Our overall strategy is to run a relatively large ensemble of about 40 members up to 3 months (focusing on the sub-seasonal forecast problem), after which we sub-sample the ensemble, and continue the forecast with about 10 members (up to 12 months). Here we present the results of our testing of various ways to generate the initial perturbations and the validation of a stratified sampling approach for choosing the members of the smaller ensemble. For the initialization of the ensemble we propose a combination of lagged and burst initial conditions. To generate perturbations for the burst ensemble members we used scaled differences of pairs of analysis states (chosen randomly from the corresponding season) separated by 1-10 days. We consider perturbing separately the atmosphere and the ocean, or both. By varying the separation times between the analysis states, we are able to produce perturbations that resemble well-known modes of variability. Focusing on the ENSO SST indices, we found that all types of perturbations are important for the ensemble spread with, however, considerable differences in the timing of the impacts on spread for the atmospheric and oceanic perturbations.Our initial (larger) ensemble size was determined so as to maximize the skill of predicting some of the leading modes of boreal winter atmospheric modes (namely the NAO, PNA and AO). Since it is not feasible for us to run with the larger ensemble beyond about 3 months, we employ a stratified sampling procedure that identifies the emerging directions of error growth to subset the ensemble. By comparing the results from the stratified ensemble with that of the randomly sampled ensemble of the same size, we find that the former provides substantially better estimates the mean of the original large ensemble.

Borovikov, Anna↗