Crude Oil Characterization Research Study Task 2: Sampling & Analysis Methods Evaluation.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.
A simple and automated spot sampling operation mode for a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry (LMJ-SSP/ESI-MS) system is reported. Prior manual and automated spot sampling methods with this probe relied on a careful, relatively slow alignment of the probe and surface distance (< 20 m spacing) to form the probe - to - surface liquid microjunction critical to successful surface sampling. Moreover, sampling multiple spots required retraction of the surface from the probe and a repeat of this careful probe - to - surface distance alignment at the next sampling position. With the method described here, the probe was not positioned as close to the surface, the exact probe - to - surface positioning was found to be less critical (spanning distances from about 100 300 m), and this distance was not altered during the sampling of an entire array of sample spots. With the probe positioned within the appropriate distance from the surface, the liquid microjunction was formed by letting the liquid from the sampling end of the probe extend out from the probe to the surface. This was accomplished by reducing the self-aspiration liquid flow rate of the probe to a value less than the volume flow rate pumped into the probe. When the self-aspiration rate of the probe was subsequently increased, analytes on the surface that dissolved at the liquid microjunction were aspirated back into the probe with the liquid that created the liquid microjunction and electrosprayed. Presented here are the basics of this new sampling mode, as well as data that illustrate the potential analytical capabilities of the device to conduct high-throughput quantitative analysis.
Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.
Magnetoelectric materials couple both magnetic and electronic properties, making them attractive for use in multifunctional devices. The magnetoelectric AFeO 3 compounds (Pna2 1 ; A = Al, Ga) have received attention as the properties of the system depend on composition as well as the synthetic method used. Al 1–x Ga x FeO 3 (0 ≤ x ≤ 1) was synthesized by the sol–gel and coprecipitation methods and studied by X-ray absorption near-edge spectroscopy (XANES). Al L 2,3⁻ , Ga K-, and Fe K-edge XANES spectra were collected to examine how the average metal coordination number (CN) changes with the synthetic method. Al and Fe were found to prefer octahedral sites, while Ga prefers the tetrahedral site. It was found that composition played a larger role in determining site occupancies than synthetic method. Samples made by the sol–gel or ceramic methods (reported previously; Walker, J. D. S.; Grosvenor, A. P. J. Solid State Chem. 2013, 197, 147–153) showed smaller spectral changes than samples made via the coprecipitation method. This is attributed to greater ion mobility in samples synthesized via coprecipitation as the reactants do not have a long-range polymeric or oxide network during synthesis like samples synthesized via the sol–gel or ceramic method. Increasing annealing temperature increases the average coordination number of Al, and to a lesser extent Ga, while the average coordination number of Fe decreases. This study indicates that greater disorder is observed when the Al 1–x Ga x FeO 3 compounds have high Al content, and when annealed at higher temperatures.
Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)
ABSTRACT We introduce a novel approach to boost the efficiency of the importance nested sampling (INS) technique for Bayesian posterior and evidence estimation using deep learning. Unlike rejection-based sampling methods such as vanilla nested sampling (NS) or Markov chain Monte Carlo (MCMC) algorithms, importance sampling techniques can use all likelihood evaluations for posterior and evidence estimation. However, for efficient importance sampling, one needs proposal distributions that closely mimic the posterior distributions. We show how to combine INS with deep learning via neural network regression to accomplish this task. We also introduce nautilus, a reference open-source python implementation of this technique for Bayesian posterior and evidence estimation. We compare nautilus against popular NS and MCMC packages, including emcee, dynesty, ultranest, and pocomc, on a variety of challenging synthetic problems and real-world applications in exoplanet detection, galaxy SED fitting and cosmology. In all applications, the sampling efficiency of nautilus is substantially higher than that of all other samplers, often by more than an order of magnitude. Simultaneously, nautilus delivers highly accurate results and needs fewer likelihood evaluations than all other samplers tested. We also show that nautilus has good scaling with the dimensionality of the likelihood and is easily parallelizable to many CPUs.
For the multiple sources of error introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily to quantify the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the “two-step” method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the two-step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution was examined in the framework of phase I-3 of the OECD Uncertainty Analysis in Modeling benchmark. With the Three Mile Island Unit 1 core as a base model for analysis, the XSUSA and two-step methods were applied with certain limitations, and the results were compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions were drawn as to the method that is currently more viable for computing uncertainties in burnup and transient calculations.
A series of numerical test cases reflecting broad and realistic ranges of geological formation and preexisting fault properties was developed to systematically evaluate the impacts of preexisting faults on pressure buildup and ground surface uplift during CO₂ injection. Numerical test cases were conducted using a coupled hydro-geomechanical simulator, eSTOMP (extreme-scale Subsurface Transport over Multiple Phases). For efficient sensitivity analysis and reliable construction of a reduced-order model, a quasi-Monte Carlo sampling method was applied to effectively sample a high-dimensional input parameter space to explore uncertainties associated with hydrologic, geologic, and geomechanical properties. The uncertainty quantification results show that the impacts on geomechanical response from the pre-existing faults mainly depend on reservoir and fault permeability. When the fault permeability is two to three orders of magnitude smaller than the reservoir permeability, the fault can be considered as an impermeable block that resists fluid transport in the reservoir, which causes pressure increase near the fault. When the fault permeability is close to the reservoir permeability, or higher than 10⁻¹⁵ m² in this study, the fault can be considered as a conduit that penetrates the caprock, connecting the fluid flow between the reservoir and the upper rock.
The electric field of coherent synchrotron radiation (CSR) generated by laser bunch slicing in a storage ring has been detected by an electro-optic sampling method. The gate pulses for sampling are sent through a large-mode-area photonic-crystal fiber. The observed electric field profile of the CSR is in good agreement with the spectrum of the CSR observed using Fourier transform far-infrared spectrometry, indicating good phase stability in the CSR. The longitudinal density profiles of electrons modulated by laser pulses were evaluated from the electric field profile.
Quantifying changes in soil organic carbon (SOC) stocks and other soil properties is essential for understanding how soils will respond to land management practices and global change. Although they are widely used, comparisons of SOC stocks at fixed depth (FD) intervals are subject to errors when changes in bulk density or soil organic matter occur. The equivalent soil mass (ESM) method has been recommended in lieu of FD for assessing changes in SOC stocks in mineral soils, but ESM remains underutilized for SOC stocks and has rarely been used for other soil properties. In this paper, we draw attention to the limitations of the FD method and demonstrate the advantages of the ESM approach. We provide illustrations to show that the FD approach is susceptible to errors not only for quantifying SOC stocks but also for soil mass-based properties such as SOC mass percent, C:N mass ratio, and δ 13 C. Here we describe the ESM approach and show how it mitigates the FD method limitations. Using bulk density change simulations applied to an empirical dataset from bioenergy cropping systems, we show that the ESM method provides consistently lower errors than FD when quantifying changes in SOC stocks and other soil properties. To simplify the use of ESM, we detail how the method can be integrated into sampling schemes, and we provide an example R computer script that can perform ESM calculations on large datasets. We encourage future studies, whether temporal or comparative, to utilize sampling methods that are amenable to the ESM approach. Overall, we agree with previous recommendations that ESM should be the standard method for evaluating SOC stock changes in mineral soils, but we further suggest that ESM may also be preferred for comparisons of other soil properties including mass percentages, elemental mass ratios, and stable isotope composition.
We present the first event-horizon-scale images and spatiotemporal analysis of Sgr A* taken with the Event Horizon Telescope in 2017 April at a wavelength of 1.3 mm. Imaging of Sgr A* has been conducted through surveys over a wide range of imaging assumptions using the classical CLEAN algorithm, regularized maximum likelihood methods, and a Bayesian posterior sampling method. Different prescriptions have been used to account for scattering effects by the interstellar medium toward the Galactic center. Mitigation of the rapid intraday variability that characterizes Sgr A* has been carried out through the addition of a “variability noise budget” in the observed visibilities, facilitating the reconstruction of static full-track images. Our static reconstructions of Sgr A* can be clustered into four representative morphologies that correspond to ring images with three different azimuthal brightness distributions and a small cluster that contains diverse nonring morphologies. Based on our extensive analysis of the effects of sparse (u,v)-coverage, source variability, and interstellar scattering, as well as studies of simulated visibility data, we conclude that the Event Horizon Telescope Sgr A* data show compelling evidence for an image that is dominated by a bright ring of emission with a ring diameter of ∼50 μas, consistent with the expected “shadow” of a 4 × 10$^{6}$ M $_{⊙}$ black hole in the Galactic center located at a distance of 8 kpc.
Recently, Fokker–Planck based particle Monte Carlo schemes have been proposed and evaluated for simulations of rarefied gas flows [1–3]. In this paper, the variance reduction for particle Monte Carlo simulations based on the Fokker–Planck model is considered. First, deviational based schemes were derived and reviewed, and it is shown that these deviational methods are not appropriate for practical Fokker–Planck based rarefied gas flow simulations. This is due to the fact that the deviational schemes considered in this study lead either to instabilities in the case of two-weight methods or to large statistical errors if the direct sampling method is applied. Motivated by this conclusion, we developed a novel scheme based on correlated stochastic processes. The main idea here is to synthesize an additional stochastic process with a known solution, which is simultaneously solved together with the main one. By correlating the two processes, the statistical errors can dramatically be reduced; especially for low Mach numbers. To assess the methods, homogeneous relaxation, planar Couette and lid-driven cavity flows were considered. For these test cases, it could be demonstrated that variance reduction based on parallel processes is very robust and effective.
In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.
We present new methods for solving a broad class of bound-constrained nonsmooth composite minimization problems. These methods are specially designed for objectives that are some known mapping of outputs from a computationally expensive function. We provide accompanying implementations of these methods: in particular, a novel manifold sampling algorithm (MS-P) with subproblems that are in a sense primal versions of the dual problems solved by previous manifold sampling methods and a method (GOOMBAH) that employs more difficult optimization subproblems. For these two methods, we provide rigorous convergence analysis and guarantees. We demonstrate extensive testing of these methods. Open-source implementations of the methods developed in this manuscript can be found at https://github.com/POptUS/ IBCDFO/.
This is the final scientific and technical report for this award. Molecular dynamics (MD) is a powerful tool to study biomolecules at the nanoscale. One of its main limitations however is that such simulations typically require a timestep of 1 femtosecond while reactions and conformational changes typically happen on the time scale of 1 microsecond or more. This discrepancy severely restricts the impact of this method. We have developed a series of algorithms to mitigate this problem and allow predicting long-time scale events using much shorter simulations. The method is based on the concurrent adaptive sampling method. It consists in using probabilistic weights for trajectories and biasing the sampling such that rare but important trajectories, e.g., those that go over energy barriers and lead to relevant conformational changes in the molecule, are observed with much higher frequency that in a standard MD simulation. We will demonstrate below that this approach has been very successful. In collaboration with Jay Grate at PNNL we have applied this novel method to the study the triazine polymers, which can be con gured using different types of side chains in order to adopt different 3-dimensional structures. We have found novel stable con- formations and have analyzed the impact of side chain modifcations on the native folded shape of the polymer. Direct MD simulations would have been untractable for this problem. The method of replica exchange was also used successfully to calculate free energy profiles, in particular for cis-trans torsional angle changes with high energy barriers. Studying molecules at the atomistic scale is essential to design new molecules in chemical engineering, such as the triazine polymers developed by Grate, in material science to study the strength of metals for examples (e.g., dislocation dynamics), or in biochemistry to understand how proteins fold and how they interact with ligands (a key step in designing drugs). Although new hardware makes these simulations increasingly faster (e.g., GPU, Anton from DE Shaw Research), new algorithms are key to making these methods more tractable and increase their impact. At this point, because of limitations in modeling, one of the main techniques for advancing science remains to a large extent numerous and costly experiments. For exam- ple, when designing drug, where multiple variants must be screened, the ability to run tests on a computer rather than experimentally testing with high throughput methods thousands of compounds would represent a signi cant advance with broad benefits for the public at large.