Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Gallium phosphide energy converters

Betavoltaic power supplies based on gallium phosphide can supply long term low-level power with high reliability. Results are presented for GaP devices powered by Ni-63 and tritiarated phosphors. Leakage currents as low as 1.2 x 10(exp -17) A/cm(exp 2) have been measured and the temperature dependence of the reverse saturation current is found to have ideal behavior. A small demonstration system has been assembled that generates and stores enough electricity to light up an LED.

Sims, P. E.↗

Occurrence of Ice Supersaturations, Ice Clouds, and Ternary Aerosols in the Arctic Lowermost Stratosphere

Relative humidity, aerosol concentration, and ice crystals all have important impacts on chemistry and radiative transfer in the lowermost stratosphere. In this study, we have combined SOLVE measurements with meteorological analyses to investigate the statistics of humidity, aerosols, and clouds in the arctic lower stratosphere. First, we will present a statistical analysis of relative humidity with respect to ice in the lowermost stratosphere, used on the DC-8 in situ measurements. We will show examples of ice supersaturation well within the stratosphere. Generally, these cases were associated with extremely low temperatures near the tropopause. Next, we will discuss the climatological occurrence frequency of tropopause temperatures low enough for ice saturation even with typically low stratospheric water vapor mixing ratios. Really, we will examine case studies of ice clouds observed in the lowermost stratosphere during SOLVE. We will discuss the possible origin of these clouds (i.e., precipitation from higher type II PSCs, injection of tropospheric air into the lower stratosphere, etc.).

Jensen, Eric↗

Functionalization of carbon nanotubes

Method and system for functionalizing a collection of carbon nanotubes (CNTs). A selected precursor gas (e.g., H.sub.2 or F.sub.2 or C.sub.nH.sub.m) is irradiated to provide a cold plasma of selected target particles, such as atomic H or F, in a first chamber. The target particles are directed toward an array of CNTs located in a second chamber while suppressing transport of ultraviolet radiation to the second chamber. A CNT array is functionalized with the target particles, at or below room temperature, to a point of saturation, in an exposure time interval no longer than about 30 sec.

Khare, Bishun N.↗

Thermal Structure of the TTL and Its Relation to Stratospheric-Tropospheric Exchange of Water

This document describes the annual cycle of the trajectory track line (TTL) fine scale thermal structure as captured by global positioning system (GPS) radio occultation and the pressure levels of the East Meets West Foundation (EMWF) weather analysis. This annual cycle is compared to the annual cycle in water concentrations measured by the HALogen Occultation Experiment (HALOE). A comparison between saturation mixing ratios at the temperatures captured by GPS radio occultation and HALOE concentrations of water vapor shows an annual cycle that is dominated by supersaturation in the boreal winter months, when the upward mass fluxes are larger, and subsaturation in the summer. The longitudinal dependence of these cycles is discussed as well as the possible implications for the seasonality of stratospheric-troposheric exchanges of water.

climates↗

Functionalization of Carbon Nanotubes

Method and system for functionalizing a collection of carbon nanotubes (CNTs). A selected precursor gas (e.g., H2, or F2, or CnHm) is irradiated to provide a cold plasma of selected target particles, such as atomic H or F, in a first chamber. The target particles are directed toward an array of CNTs located in a second chamber while suppressing transport of ultraviolet radiation to the second chamber. A CNT array is functionalized with the target particles, at or below room temperature, to a point of saturation, in an exposure time interval no longer than about 30 sec.

Khare, Bishun N.↗

Solution Growth and Characterization of Single Crystals on Earth and in Microgravity

Crystal growth has been of interest to physicists and engineers for a long time because of their unique properties. Single crystals are utilized in such diverse applications as pharmaceuticals, computers, infrared detectors, frequency measurements, piezoelectric devices, a variety of high-technology devices, and sensors. Solution crystal growth is one of the important techniques to grow a variety of crystals when the material decomposes at the melting point and a suitable solvent is available to make a saturated solution at a desired temperature. In this Technical Memorandum (TM) an attempt is made to give the fundamentals of growing crystals from solution including improved designs of various crystallizers. Since the same solution crystal growth technique could not be used in microgravity, the authors proposed a new cooled-sting technique to grow crystals in space. The authors experience from conducting two Space Shuttle solution crystal growth experiments are also detailed in this TM and the complexity of solution growth experiments to grow crystals in space are also discussed. These happen to be some of the early experiments performed in space, and various lessons learned are described. A brief discussion of protein crystal growth that shares basic principles of the solution growth technique is given, along with some flight hardware information for growth in microgravity.

Aggarwal, M. D.↗

Functionalization of Carbon Nanotubes

Method and system for functionalizing a collection of carbon nanotubes (CNTs). A selected precursor gas (e.g., H2 or F2 or CnHm) is irradiated to provide a cold plasma of selected target species particles, such as atomic H or F, in a first chamber. The target species particles are d irected toward an array of CNTs located in a second chamber while suppressing transport of ultraviolet radiation to the second chamber. A CNT array is functionalized with the target species particles, at or below room temperature, to a point of saturation, in an exposure time interval no longer than about 30 sec. *Discrimination against non-target species is provided by (i) use of a target species having a lifetime that is much greater than a lifetime of a non-target species and/or (2) use of an applied magnetic field to discriminate between charged particle trajectories for target species and for non-target species.

Khare, Bishun N.↗

Selective functionalization of carbon nanotubes based upon distance traveled

Method and system for functionalizing a collection of carbon nanotubes (CNTs). A selected precursor gas (e.g., H.sub.2 or NH.sub.3 or NF.sub.3 or F.sub.2 or CF.sub.4 or C.sub.nH.sub.m) is irradiated to provide a cold plasma of selected target particles, such as atomic H or F, in a first chamber. The target particles are directed toward an array of CNTs located in a second chamber while suppressing transport of ultraviolet radiation to the second chamber. A CNT array is functionalized with the target particles, at or below room temperature, to a point of saturation, in an exposure time interval no longer than about 30 sec. The predominant species that are deposited on the CNT array vary with the distance d measured along a path from the precursor gas to the CNT array; two or three different predominant species can be deposited on a CNT array for distances d=d1 and d=d2>d1 and d=d3>d2.

Khare, Bishun N.↗

Growth and Characteristics of Bulk Single Crystals Grown from Solution on Earth and in Microgravity

The growth of crystals has been of interest to physicists and engineers for a long time because of their unique properties. Single crystals are utilized in such diverse applications as pharmaceuticals, computers, infrared detectors, frequency measurements, piezoelectric devices, a variety of high technology devices and sensors. Solution crystal growth is one of the important techniques to grow a variety of crystals when the material decomposes at the melting point and a suitable solvent is available to make a saturated solution at a desired temperature. In this chapter an attempt is made to give some fundamentals of growing crystals from solution including improved designs of various crystallizers. Since the same solution crystal growth technique could not be used in microgravity, authors had proposed a new cooled sting technique to grow crystals in space. Authors? experiences of conducting two space shuttle experiments relating to solution crystal growth are also detailed in this work. The complexity of these solution growth experiments to grow crystals in space are discussed. These happen to be some of the early experiments performed in space, and various lessons learned are described. A brief discussion of protein crystal growth that also shares basic principles of solution growth technique is given along with some flight hardware information for its growth in microgravity.

Aggarwal, M. D.↗

Mercury-Cadmium-Telluride Focal Plane Array Performance Under Non-Standard Operating Conditions

This paper highlights a new technique that allows the Teledyne Scientific & Imaging LLC TCM6604A Mercury-Cadmium-Telluride (MCT) Focal Plane Array (FPA) to operate at room temperature. The Teledyne MCT FPA has been a standard in Imaging Spectroscopy since its creation in the 1980's. This FPA has been used in applications ranging from space instruments such as CRISM, M3 and ARTEMIS to airborne instruments such as MaRS and the Next Generation AVIRIS Instruments1. Precise focal plane alignment is always a challenge for such instruments. The current FPA alignment process results in multiple cold cycles requiring week-long durations, thereby increasing the risk and cost of a project. These alignment cycles are necessary because optimal alignment is approached incrementally and can only be measured with the FPA and Optics at standard operating conditions, requiring a cold instrument. Instruments using this FPA are normally cooled to temperatures below 150K for the MCT FPA to properly function. When the FPA is run at higher temperatures the dark current increases saturating the output. This paper covers the prospect of warm MCT FPA operation from a theoretical and experimental perspective. We discuss the empirical models and physical laws that govern MCT material properties and predict the optimal settings that will result in the best MCT PA performance at 300K. Theoretical results are then calculated for the proposed settings. We finally present the images and data obtained using the actual system with the warm MCT FPA settings. The paper concludes by emphasizing the strong positive correlation between the measured values and the theoretical results.

Focal Plane Array (FPA)↗

Update of S-NPP VIIRS Thermal Emissive Bands Radiometric Calibration Stability Monitoring Using the Moon

The Suomi-NPP VIIRS thermal emissive bands (TEB) are radiometrically calibrated on-orbit with reference to an onboard blackbody (BB) regularly operated at approximately 292.5 K. The calibration stability at other temperature ranges can be evaluated based on the observations of remote targets with stable thermal properties, such as the Moon. VIIRS has scheduled viewings of the Moon on a nearly monthly basis at a phase angle of nearly -51 degrees. In this study, the brightness temperatures (BT) of the lunar surface retrieved using the detector gain coefficients calibrated with the BB are trended to monitor the calibration stability of VIIRS TEB. Since the Lunar surface temperatures are spatially non-uniform and vary greatly with the photometric geometry, the BT trending must be based on the same regions of the Moon under the same solar illumination condition. Also, the TEB lunar images are always partially saturated because the highest lunar surface temperatures are beyond the dynamic range of all VIIRS TEB detectors. Therefore, a temporally invariant dynamic mask is designed to clip a fraction of the lunar images corresponding to the regions of the Moon that may saturate the detector at any lunar event. The BT of the remaining hottest pixels are then trended. Results show that, since the launch of VIIRS to mid-2016, the radiometric calibration of all TEB detectors has been stable within 0.4 K at the BT range of as high as 350 K.

Wang, Zhipeng↗

Atmospheric temperatures near the tropical tropopause Temporal variations, zonal asymmetry and implications for stratospheric water vapor

Analysis of temperature measurements obtained over an eight-year period in the vicinity of the low-latitude tropopause confirms the existence of longitude regions which are consistently colder by approximately 2-3 K than elsewhere in the tropics. These temperature differences, however, are confined to a layer of thickness 3-5 km centered on the tropopause. The lowest monthly mean temperatures observed at the colder stations yield saturation mixing ratios that are consistent with the range of measured stratospheric water vapor. Examination of the daily variations in temperature at a given station reveals a more complex pattern than indicated by the monthly averages. On many days temperatures at the colder longitudes correspond to water vapor abundances that are less than observed in the stratosphere despite the favorable comparison of the monthly means. The results point to the need for a series of water vapor soundings at selected longitudes and times in order to define the extent to which the tropical tropopause controls the stratospheric water vapor abundance.

Frederick, J. E.↗

The co-adsorption of copper and oxygen on a tungsten 100 plane-type surface

The coadsorption of Cu on O2 and a W 100 plane-type surface is studied by Auger electron spectroscopy, thermal desorption, low energy electron diffraction and by work function change measurements. It is shown that the presence of Cu on the surface initially decreases the sticking coefficient of O2. For longer oxygen exposures and for higher adsorption temperatures, the coverage of preadsorbed oxygen reaches values larger than those on the clean surface for the same O2 exposure. Except at the highest values and temperatures of the coverage of preadsorbed oxygen, the sticking coefficient for copper is unity and is independent of the oxygen coverage in the range studied. Coadsorption at room temperatures does not produce any long range order while coadsorption at elevated temperature leads to ordered structures. The saturation coverage of the two dimensional coadsorbate at 800 K is given by a relation. The work function is a complicated function of the coverage of preadsorbed oxygen and the coverage of preadsorbed Cu and is determined predominantly by the temperature at which oxygen is adsorbed. At high temperatures the sequence of adsorption has no influence, in contrast to the room temperature behavior.

Bauer, E.↗

Isolation and Physiological Characterization of Psychrophilic Denitrifying Bacteria from Permanently Cold Arctic Fjord Sediments (Svalbard, Norway)

A large proportion of reactive nitrogen loss from polar sediments is mediated by denitrification, but microorganisms mediating denitrification in polar environments remain poorly characterized. A combined approach of most-probable-number (MPN) enumeration, cultivation and physiological characterization was used to describe psychrophilic denitrifying bacterial communities in sediments of three Arctic fjords in Svalbard (Norway). A MPN assay showed the presence of 10(sup 3)−10(sup 6) cells of psychrophilic nitrate-respiring bacteria g(sup −1) of sediment. Fifteen strains within the Proteobacteria were isolated using a systematic enrichment approach with organic acids as electron donors and nitrate as an electron acceptor. Isolates belonged to five genera, including Shewanella, Pseudomonas, Psychromonas (Gammaproteobacteria), Arcobacter (Epsilonproteobacteria) and Herminiimonas (Betaproteobacteria). All isolates were denitrifiers, except Shewanella, which exhibited the capacity for dissimilatory nitrate reduction to ammonium (DNRA). Growth from 0 to 40 degC demonstrated that all genera except Shewanella were psychrophiles with optimal growth below 15 degC, and adaptation to low temperature was demonstrated as a shift from primarily C16:0 saturated fatty acids to C16:1 monounsaturated fatty acids at lower temperatures. This study provides the first targeted enrichment and characterization of psychrophilic denitrifying bacteria from polar sediments, and two genera, Arcobacter and Herminiimonas, are isolated for the first time from permanently cold marine sediments.

Psychrophile↗

Electron spin resonance study of thermal instability reactions in jet fuels

Free radicals were studied by electron spin resonance (ESR) using model compounds that are representative of constituents of jet fuels. Radical formation was initiated with peroxides and hydroperoxides by using UV photolysis at and near room temperature and thermal initiation at higher temperatures. Both oxygen free and air saturated systems were studied. N-Dodecane was frequently used as a solvent, and a mixture of n-dodecyl radicals was made with a peroxide initiator in n-dodecane (free of oxygen) thermally at 212 C and photolytically at room temperature. Hydrogen abstraction from the 3,4,5 and 6-positions gives radicals that are sufficiently alike that their spectra are essentially superimposed. The radical formed by abstract of hydrogen from the 2-position gives a different spectrum. ESR parameters for these radicals were measured. The radical formed by abstraction of a primary hydrogen was not observed. Similar radicals are formed from n-decane. A variety of exploratory experiments were carried out with systems that give free radical spectra to which was added small amounts of 2,5-dimethylpyrrole.

Zeldes, H.↗

High-temperature CW and pulsed operation in constricted double-heterojunction AlGaAs diode lasers

The behavior of constricted double-heterojunction (CDH) diode lasers has been investigated up to 170 C CW and 270 C pulsed. It is found that the temperature-dependent current concentration effect responsible for low threshold-current sensitivity and temperature-invariant external differential quantum efficiency in CDH lasers saturates at about 100 C. It is also found that over a wide temperature interval (180-280 C) the threshold current density has a To value of 40-50 C and that the spontaneous emission becomes increasingly sublinear above 220 C. Both effects are believed to reflect Auger recombination.

Botez, D.↗

Wide Temperature Core Loss Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.

Niedra, Janis M.↗

Atmospheric Condensation in the Mars Phoenix TECP and MET Data

A new calibration function for the humidity sensor in the Thermal and Electrical Conductivity Probe (TECP), a component of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) on the Phoenix Mars mission has been developed. The data is now cast in terms of Frost Point (T(sub f)) and some flight data, taken when the atmosphere is independently known to be saturated, is included in the calibration data set. Combined with data from the Meteorology Mast air temperature sensors, a very sensitive detection of atmospheric saturation becomes possible (Figure 1).

Microscopy↗