Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanning probe microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Local conformations and heterogeneities in structures and dynamics of isotactic polypropylene adsorbed onto carbon fiber

Carbon fiber (CF) reinforced polymers (CFRPs) have experienced widespread use in various industries. One of the most important parameters that controls the macroscopic property of CFRPs is the interface between a polymer matrix and CF. There is growing evidence to suggest the formation of a bound polymer layer (BPL), i.e., polymer chains that physically adsorb on a filler surface. However, this interface is always in contact with the thicker part of a polymer matrix, rendering its understanding a difficult task. Therein, we use CF-reinforced isotactic polypropylene (iPP) as a rational CFRP. To characterize the BPL on the CF surface, we extracted it from the CFRP using solvent-rinsing with p-xylene. The physical and thermal properties of the BPL were characterized by differential scanning calorimetry and thermogravimetric analysis, while its microscopic structures and dynamics were probed by small-angle neutron scattering and quasi-elastic neutron scattering (QENS) techniques. Subsequently, we employed atomistic molecular dynamics (MD) simulations to complement the QENS results above the bulk melting temperature and reveal details that were experimentally inaccessible. In this work, we observed that the degree of crystallinity of the BPL was quite lower than the bulk, while the melting temperature of the BPL remained the same as the bulks. Within the given length and time scales probed by QENS and MD, we also observed that most of the bound chains were mobile, with the formation of a high-density region (less than 1 nm in thickness) near the CF surface. The segmental dynamics of the bound chains probed by both QENS and MD were also much faster than those of the free chains, possibly due to the presence of a free surface region at the topmost surface of the BPL. Furthermore, the MD results demonstrated that the backbone chains and side groups lie nearly flat on the CF surface, which is the driving force for the flattening process of the iPP BPL to overcome the conformational entropy loss in the total free energy.

36 MATERIALS SCIENCE↗

Advanced FIB-based Preparation of Cryogenically-prepared Specimens for APT Analysis

The utilization of the focused ion beam scanning electron microscope (FIB-SEM) has aided the application of Atom Probe Tomography (APT) to a continually-growing variety of materials, including soft biological materials. However, the regular application of APT to hydrated interfaces such as those found in biological and environmental materials is lacking in large part due to difficulties in specimen preparation under high and ultra-high vacuum conditions. Although a FIB-SEM based cryogenic specimen preparation approach offers a rational route to the preparation of such specimens for APT analysis, many practical aspects such as welding and limitations in the cryo stage manipulation makes it challenging for routine liftout of site-targeted specimens. In this work, we describe our recent efforts in the development of a site-specific liftout and attachment scheme for cryogenically cooled specimens involving a combination of redeposition and overcoating of organic and organometallic molecules, as shown in Fig. 1a-d for a cryogenically-frozen corroded glass sample containing a hydrated porous gel surface layer. Application of an annular milling pattern to the frozen specimens leads to a needle-shaped morphology necessary for APT analysis with the targeted water-ice filled porous corroded silicate glass region of interest near the apex. Using a custom shuttle device and environmental transfer hub at PNNL to facilitate environmentally-protected specimen transfer, APT analysis was applied to directly map, for the first time, a water/solid interface in 3D to reveal the complex nanoscale water-filled porous network of corroded glass. Application of this unique specimen preparation approach to biological specimens will also be discussed, as well as the application of a unique cryo nanomaniupulator with integrated gas injection system to enable controlled FIB-based welding under cryogenic temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring inside damage of individual multi-walled carbon nanotubes using scanning transmission X-ray microscopy

The electronic structure of individual multi-walled carbon nanotubes (MWCNTs) has been probed using scanning transmission X-ray microscopy (STXM). Although transmission electron microscope (TEM) images show that the exterior of the MWCNTs are clean and straight; the inside structure of some of the MWCNTs is much less well ordered, as revealed by STXM. The amorphization of the interior tubes can be introduced in the growth or modification processes. Moreover, TEM measurement with high dose may also lead to the inside damage. Our results reveal that the structure of individual MWCNTs can be complex and suggest that electronic structure measurements are an important tool for characterizing carbon nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Charge Correlations in Cuprate Superconductors

High-temperature superconductivity, with transition temperatures up to ≈134 K at ambient pressure, occurs in layered cuprate compounds. The conducting CuO 2 planes, which are universally present, are responsible for the superconductivity but also show a disposition to other competing states including spin and charge order. Charge-density-wave (CDW) order appears to be a universal property of cuprate superconductors. It has been studied via a multitude of probes including X-ray and neutron scattering, nuclear magnetic resonance, scanning probe techniques, electronic transport, and quantum oscillations. Here, we review the microscopic properties of the CDW order. We discuss the nature of the ordered state, that is, its symmetry and microscopic structure. Furthermore, we show how the CDW order is related to quenched disorder, host structure, symmetry breaking perturbations, and magnetic fields. Here, we also describe measurements of dynamic collective charge excitations that are closely related to the quasi-static CDW order. Finally, we highlight some of the debated issues in the field, including the origin of the CDW order, the relationship to spin order, and the nature of the spatial CDW correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of Probe Position-Dependent Electron Energy-Loss Fine Structure

We present a theoretical framework for calculating probe-position-dependent electron energy-loss near-edge structure for the scanning transmission electron microscope by combining density functional theory with dynamical scattering theory. We show how simpler approaches to calculating near-edge structure fail to include the fundamental physics needed to understand the evolution of near-edge structure as a function of probe position and investigate the dependence of near-edge structure on probe size. It is within this framework that density functional theory should be presented, in order to ensure that variations of near-edge structure are truly due to local electronic structure and how much from the diffraction and focusing of the electron beam.

Oxley, M. P.↗

Analytical scanning evanescent microwave microscope and control stage

A scanning evanescent microwave microscope (SEMM) that uses near-field evanescent electromagnetic waves to probe sample properties is disclosed. The SEMM is capable of high resolution imaging and quantitative measurements of the electrical properties of the sample. The SEMM has the ability to map dielectric constant, loss tangent, conductivity, electrical impedance, and other electrical parameters of materials. Such properties are then used to provide distance control over a wide range, from to microns to nanometers, over dielectric and conductive samples for a scanned evanescent microwave probe, which enable quantitative non-contact and submicron spatial resolution topographic and electrical impedance profiling of dielectric, nonlinear dielectric and conductive materials. The invention also allows quantitative estimation of microwave impedance using signals obtained by the scanned evanescent microwave probe and quasistatic approximation modeling. The SEMM can be used to measure electrical properties of both dielectric and electrically conducting materials.

47 OTHER INSTRUMENTATION↗

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

Phase stability, mechanical properties, and ion irradiation effects in face-centered cubic CrFeMnNi compositionally complex solid-solution alloys at high temperatures

We report two CrFeMnNi face-centered cubic complex concentrated solid-solution alloys (CSA) have been evaluated for phase stability, mechanical properties, and radiation damage effects from heavy ions. Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 were predicted by thermodynamic calculations to phase separate and maintain a single phase at 700 °C, respectively. Aging experiments at this temperature confirmed varying degrees of precipitation of a body-centered cubic phase in both Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 . The alloys showed promising strength in tensile deformation at room temperature, with yield strengths of 155 MPa and 151 MPa for Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe3 5 Mn 15 Ni 35 , respectively. At 500 °C, the yield strength of Cr 18 Fe 27 Mn 27 Ni 28 fell to 93 MPa, and to 100 MPa in Cr 15 Fe3 5 Mn 15 Ni 35 . Unlike Cr 18 Fe 27 Mn 27 Ni 28 , Cr 15 Fe 35 Mn 15 Ni 35 gained some ductility at 500 °C compared to room temperature. The two CSAs were irradiated to 75 dpa at 500 °C in the plateau region of the displacement curve using 3.7 MeV Ni 2+ ions, alongside model alloy 709 as a reference. Irradiation results produced similar densities and sizes of dislocations loops in the two CSAs compared to the reference. However, while large voids form in the plateau region of Cr 18 Fe 27 Mn 27 Ni 28 , small voids form just beyond the displacement peak of Cr 15 Fe 35 Mn 15 Ni 35 . Atom probe tomography and energy dispersive X-ray spectroscopy-equipped scanning transmission electron microscopes were used to characterize the alloys for changes in chemical distribution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

We report the ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. Here, we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials.

36 MATERIALS SCIENCE↗

Development of a Novel Environmental Cell for In-Situ Gas Reaction Experiments via Aberration-Corrected STEM Imaging

A novel heating technology composed of a disposable MEMS-based (microelectromechanical systems) device has recently been developed and shown to provide unique in-situ heating capabilities in electron microscopes [1]. Protochips, Inc. (Raleigh, NC) provides the AduroTM heater technology, composed of a disposable MEMS device that serves both as the heating element and the specimen support grid, a TEM holder with electrical feed-throughs, and an external current source. This system has been shown to provide near instantaneous (106 C/s) heating and cooling, and is stable to the limit of the microscope's specimen stage so full sub- ngstr m image resolution in highangle annular dark-field imaging mode can be achieved on our JEOL 2200FS scanning transmission electron microscope (STEM/TEM) instrument, fitted with a hexapole corrector on the probe-forming lenses (CEOS GmbH, Heidelberg, Ger.). This heating technology is being extended to function in a closed cell system that allows heating in a gaseous environment for in-situ elevated temperature reaction studies. The design concepts and early results of testing of the environmental cell (E-cell) performance are detailed here.

aberration-corrected↗

Atomistic Defect Makes a Phase Plate for the Generation and High-Angular Splitting of Electron Vortex Beams

Topological defects in solid-state materials by breaking the translational symmetry offer emerging properties that are not present in their parental phases. For example, edge dislocations—the 2π phase-winding topological defects—in antiferromagnetic NiO crystals can exhibit ferromagnetic behaviors. We study how these defects could give rise to topological orders when they interact with a high-energy electron beam. To probe this interaction, we formed a coherent electron nanobeam in a scanning transmission electron microscope and recorded the far-field transmitted patterns as the beam steps through the edge dislocation core in [001] NiO. Surprisingly, we found the amplitude patterns of the <020> Bragg disks evolve in a similar manner to the evolution of an annular solar eclipse. Using the ptychographic technique, we recovered the missing phase information in the diffraction plane and revealed the topological phase vortices in the diffracted beams. Through atomic topological defects, the wave function of electrons can be converted from plane wave to electron vortex. Technologically, this approach provides a feasible route for the fabrication of phase plates that can generate electron vortex beams with an angular separation that is three orders of magnitude larger than what traditional nanofabrication technology can offer. This advance will enable the collection of magnetic circular dichroism spectra with high spatial resolution and high efficiency, boosting the understanding of the relationship between symmetry breaking and magnetic property of individual topological defect at the atomic scale.

36 MATERIALS SCIENCE↗

Detection of magnetic circular dichroism in amorphous materials utilizing a single-crystalline overlayer

Physicists are fascinated with topological defects in solid-state materials, because by breaking the translational symmetry they offer emerging properties that are not present in their parental phases. For example, edge dislocations—the 2π phase-winding topological defects—in antiferromagnetic NiO crystals can exhibit ferromagnetic behaviors. Herein, we study how these defects could give rise to exotic topological orders when they interact with a high energy electron beam. To probe this interaction, we formed a coherent electron nanobeam in a scanning transmission electron microscope and recorded the far-field transmitted patterns as the beam steps through the edge dislocation core in [001] NiO. Surprisingly, we found the amplitude patterns of the <020> Bragg disks evolve in a similar manner to the evolution of an annular solar eclipse. Using the ptychographic technique, we recovered the missing phase information in the diffraction plane and revealed the topological phase vortices in the diffracted beams. Through atomic topological defects, the wave function of electrons can be converted from plane wave to electron vortex. This approach provides a new perspective for boosting the collection efficiency of magnetic circular dichroism spectra with high spatial resolution and understanding the relationship between symmetry breaking and exotic property of individual topological defect at atomic level.

36 MATERIALS SCIENCE↗

Radioactive Material Inventory Optimization Using the Plutonium-239 Equivalent Curie Methodology

ABSTRACT The purpose of this paper is to provide the technical basis for application of the Plutonium 239 equivalent curies (PEC) concept used to optimize and limit the material-at-risk (MAR) in the Irradiated Materials Characterization Laboratory (IMCL) located at the Materials and Fuels Complex (MFC). The PEC concept offers a method to normalize all radionuclides to a common radiotoxic hazard index that can be summed to a single value. This paper describes the technical approach to applying the PEC concept, documents the weighting factors and specific activities to be utilized in the calculation, and provides an example of the application of the concept to a radionuclide distribution that is representative of materials encountered in the IMCL. The IMCL is operated to provide a dynamic, re-configurable capability to analyze and characterize irradiated or non-irradiated radioactive material samples. The operations unique to the IMCL include sample storage, preparation, and analysis using experiment-specific instrumentation such as, Electron probe micro-analyzer (EPMA), Focused ion beam (FIB), Transmission electron microscope (TEM), and Scanning electron microscope (SEM). The methodology used to characterize the radioactive material inventory enables the IMCL to operate in such a way that complements their capability and program goals without compromising the safety of the worker, co-located worker, or the general public. The PEC concept offers a method in which all radionuclide inventory is normalized to a common radiotoxic hazard index that can be summed to a single value. The PEC concept is useful in the comparison of various material types for hazard categorization and for identifying worst-case and bounding inventory.

07 ISOTOPE AND RADIATION SOURCES↗

Enhancing the local conductivity of Cu films using temperature-assisted agglomerated Cu nanostructures

We investigate the structural and electrical properties of Cu film and reveal their changes as a function of post-annealing temperature. Thermal annealing of a Cu film on a dielectric substrate can improve its crystallinity; however, high-temperature annealing also leads to a morphological transformation that hinders the precise measurement of electrical properties. The enhanced crystallinity of the Cu films is verified with x-ray diffraction as the annealing temperature increases. To examine the electrical properties of the Cu film after the dewetting processes, which promotes the formation of voids and agglomerations, we utilize both conventional micro four-point probe method as well as an advanced four-point probe scanning tunneling microscopy (4P-STM) technique to measure the conductance and evolution of the microscopic structural properties. We could eliminate a deceptive effect of voids with 4P-STM technique, and disclosed a significantly reduced resistivity (1.88 ± 0.07 µΩ∙cm) of Cu nanostructure after post-annealing at 700 °C. We unveiled impact of crystallinity and imperfections of Cu nanostructure, and discussed the critical role of the twin grain boundaries of single-crystalline Cu (1 1 1) on an Al 2 O 3 substrate. We anticipate that understanding the evolution of the structures and the enhanced electrical properties of the post-annealed Cu nanostructures would be important for nanoscale devices where Cu is used as an interconnecting material and could provide a new route to control the plasmonic applications.

36 MATERIALS SCIENCE↗

Luminescence-based magnetic imaging with scanning x-ray transmission microscopy

We demonstrate the imaging of the magnetic domain configuration of cobalt structures fabricated on MgO(001) using x-ray induced optical luminescence in a scanning transmission microscope. The technique relies on the measurement of the magnetization-dependent x-ray absorption probed by the optical luminescence radiated from the MgO substrate and induced by the x-rays transmitted through the magnetic layer. This method enables the measurement of the electronic and magnetic spectroscopic properties of single crystalline layers and buried heterostructures with nanometer lateral resolution and elemental sensitivity and opens scanning transmission x-ray microscopy to materials which cannot be grown on membranes or as freestanding thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the quality of large-area monolayer graphene grown on liquid copper for size-selective ionic/molecular membrane separations

Monolayer graphene growth on liquid copper (Cu) has attracted attention due to advantages of a flat/smooth catalytic growth surface, high synthesis temperature (>1080 °C) as well as the possibility of forming graphene domains that are mobile on the liquid Cu with potential to minimize grain boundary defects and self-assemble into a continuous monolayer film. However, the quality of monolayer graphene grown on liquid copper and its suitability for size-selective ionic/molecular membrane separations has not been evaluated/studied. Here, we probe the quality of monolayer graphene grown on liquid Cu (via a metallurgical process, HSMG ® ) using Scanning Electron Microscope (SEM), High-resolution transmission electron microscope (HR-TEM), Raman spectroscopy and report on a facile approach to assess intrinsic sub-nanometer to nanometer-scale defects over centimeter-scale areas. We demonstrate high transfer yields of monolayer graphene (>93% coverage) from the growth substrate to polyimide track etched membrane (PITEM, pore diameter ~200 nm) supports to form centimeter-scale atomically thin membranes. Next, we use pressure-driven transport of ethanol to probe defects > 60 nm and diffusion-driven transport of analytes (KCl ~0.66 nm, L-Tryptophan ~0.7–0.9 nm, Vitamin B12 ~1–1.5 nm and Lysozyme ~3.8–4 nm) to probe nanoscale and sub-nanometer scale defects. Diffusive transport confirms the presence of intrinsic sub-nanometer to nanometer scale defects in monolayer graphene grown on liquid Cu are no less than that in high-quality graphene synthesized via chemical vapor deposition (CVD) on solid Cu. Our work not only benchmarks quality of graphene grown on liquid copper for membrane applications but also provides fundamental insights into the origin of intrinsic defects in large-area graphene synthesized via bottom-up processes for membrane applications.

36 MATERIALS SCIENCE↗