Search NASA⌕ Search

SEARCH · Search NASA

Results for “science traceability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Status Report on Transfer of Physical and Hydraulic Properties Databases to the Hanford Environmental Information System - PNNL Remediation Decision Support Project, Task 1, Activity 6

This document provides a status report on efforts to transfer physical and hydraulic property data from PNNL to CHPRC for incorporation into HEIS. The Remediation Decision Support (RDS) Project is managed by Pacific Northwest National Laboratory (PNNL) to support Hanford Site waste management and remedial action decisions by the U.S. Department of Energy and their contractors. The objective of Task 1, Activity 6 of the RDS project is to compile all available physical and hydraulic property data for sediments from the Hanford Site, to port these data into the Hanford Environmental Information System (HEIS), and to make the data web-accessible to anyone on the Hanford Local Area Network via the so-called Virtual Library. These physical and hydraulic property data are used to estimate parameters for analytical and numerical flow and transport models that are used for site risk assessments and evaluation of remedial action alternatives. In past years efforts were made by RDS project staff to compile all available physical and hydraulic property data for Hanford sediments and to transfer these data into SoilVision®, a commercial geotechnical software package designed for storing, analyzing, and manipulating soils data. Although SoilVision® has proven to be useful, its access and use restrictions have been recognized as a limitation to the effective use of the physical and hydraulic property databases by the broader group of potential users involved in Hanford waste site issues. In order to make these data more widely available and useable, a decision was made to port them to HEIS and to make them web-accessible via a Virtual Library module. In FY08 the original objectives of this activity on the RDS project were to: (1) ensure traceability and defensibility of all physical and hydraulic property data currently residing in the SoilVision® database maintained by PNNL, (2) transfer the physical and hydraulic property data from the Microsoft Access database files used by SoilVision® into HEIS, which is currently being maintained by CH2M-Hill Plateau Remediation Company (CHRPC), (3) develop a Virtual Library module for accessing these data from HEIS, and (4) write a User's Manual for the Virtual Library module. The intent of these activities is to make the available physical and hydraulic property data more readily accessible and useable by technical staff and operable unit managers involved in waste site assessments and remedial action decisions for Hanford. In FY08 communications were established between PNNL and staff from Fluor-Hanford Co. (who formerly managed HEIS) to outline the design of a Virtual Library module that could be used to access the physical and hydraulic property data that are to be transferred into HEIS. Data dictionaries used by SoilVision® were also provided to Fluor-Hanford personnel who are now with CHPRC. During ongoing work to ensure traceability and defensibility of all physical and hydraulic property data that currently reside in the SoilVision® database, it was recognized that further work would be required in this effort before the data were actually ported into HEIS. Therefore work on the Virtual Library module development and an accompanying User's Guide was deferred until an unspecified later date. In FY09 efforts have continued to verify the traceability and defensibility of the physical and hydraulic property datasets that are currently being maintained by PNNL. Although this is a work in progress, several of these datasets are now ready for transfer to CHRPC for inclusion in HEIS. The actual loading of data into HEIS is performed by CHPRC staff, so after the data are transferred from PNNL to CHPRC, it will be the responsibility of CHPRC to ensure that these data are loaded and made accessible. This document provides a status report on efforts to transfer physical and hydraulic property data from PNNL to CHPRC for incorporation into HEIS.

54 ENVIRONMENTAL SCIENCES↗

Superlinearity, saturation, and the PMT—Tailoring and calibration methodology for prompt radiation detectors

This work illustrates predominant measureable nonlinearities in photomultiplier tubes (PMTs) and introduces a controllable one called “Superlinearity,” signifying both a positive nonlinear response and the ability to extend linear operation by counteracting gain saturation mechanisms — charge depletion, space-charge field limitation, and secondary emission surface effects. Recognizing superlinearity and its effect on the temporal step response leads to a true definition of linearity, free of a small-signal linear assumption. Furthermore, given the prevalent use of glass microchannel-plate (MCP) PMTs in favor of a faster impulse response in spite of a small charge limit, we are motivated to examine their nonlinear amplitude response and deploy tailored gain bias string methods to fully harness the maximum linear gain as is usually done for transmissive metal mesh and reflective metal dynode PMTs. Our characterization methodology applies standard NIST-traceable calibrated laboratory equipment with absolute input-referenced techniques, examining step responses over many orders of magnitude in controlled illumination. By doing so, we quantitatively reveal the superlinearity strength independent of charge depletion, yielding true linear responsivity and effectively doubling the small-signal linear limit; this is very relevant to PMT modeling and charge deconvolution efforts. In conclusion, with further development, the tailoring strategies we introduce could be applied to MCP detectors, extracting all useful capillary charge with a significant improvement in large linear signal quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA s Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial and moderate resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists are also using the SSC V&V site to characterize thermal infrared systems and active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

SU-F-BRA-07: Dosimetric Verification of the Valencia Skin Applicator Using Gafchromic EBT3 Film

Purpose: The Valencia applicators have recently been introduced for HDR treatment of small and shallow superficial skin lesions (< 20 mm diameter and 3-mm depth). Per AAPM TG 56, any HDR applicator internal dimensions must be verified prior to clinical use. However radiographic and tomographic imaging to validate the Valencia applicators is impractical due to the Tungsten alloy housing and flattening filter. In this study, we propose to use EBT3 film to indirectly confirm the physical integrity of the Valencia applicators. Methods: Treatment plans were created using the Oncentra MasterPlan TPS v4.5 for the H2 (20-mm dia.) and H3 (30-mm dia.) Valencia Applicators. A virtual CT phantom (2-mm slice thickness) was created with one source position in water. The published effective depth method was used for each applicator to delivery 500 cGy to a 3-mm depth using the TG-43 formalism. Film measurements (n=3) at 3-mm depth and vertical plane in solid water were performed for each applicator to verify the prescribed dose calculated by the TPS. Percent depth dose curves and off-axis profiles (phantom surface and 3-mm depth) were measured and compared to published data. Films were analyzed using an in-house written program and RIT113 v6 software. Film calibration was performed per TG-55 protocol using the Ir-192 source with NIST-traceable calibration. Results: The prescription absolute dose difference was 1% for the Valencia H2 applicator and 4% for the Valencia H3 applicator. The measured percent depth dose curves and off-axis dose profiles measured for the H2 and H2 Valencia applicators are in excellent agreement with the Granero et al. Monte Carlo results{sup 1}. Conclusion: Gafchromic EBT3 film can be used to indirectly verify the internal components of special HDR skin applicators constructed from high Z materials.{sup 1}Granero et al. “Design and evaluation of a HDR skin applicator with flattening filter”, Med. Phys. 35(2), 495–503, 2008.

60 APPLIED LIFE SCIENCES↗

NPP Clouds and the Earth's Radiant Energy System (CERES) Predicted Sensor Performance Calibration and Preliminary Data Product Performance

Continuation of the Earth Radiation Budget (ERB) Climate Data Record (CDR) has been identified as critical in the 2007 NRC Decadal Survey, the Global Climate Observing System WCRP report, and in an assessment titled Impacts of NPOESS Nunn-McCurdy Certification on Joint NASA-NOAA Climate Goals. In response, NASA, NOAA and NPOESS agreed in early 2008 to fly the final existing CERES Flight Model (FM-5) on the NPP spacecraft for launch in 2010. Future opportunities for ERB CDR continuity consist of procuring an additional CERES Sensor with modest performance upgrades for flight on the NPOESS C1 spacecraft in 2013, followed by a new CERES follow-on sensor for flight in 2018 on the NPOESS C3 spacecraft. While science goals remain unchanged for the long-term ERB Climate Data Record, it is now understood that the task of achieving these goals is more difficult for two reasons. The first is an increased understanding of the dynamics of the Earth/atmosphere system which demonstrates that rigorous separation of natural variability from anthropogenic change on decadal time scales requires higher accuracy and stability than originally envisioned. Secondly, future implementation scenarios involve less redundancy in flight hardware (1 vs. 2 orbits and operational sensors) resulting in higher risk of loss of continuity and reduced number of independent observations to characterize performance of individual sensors. Although EOS CERES CDR's realize a factor of 2 to 4 improvement in accuracy and stability over previous ERBE CDR's, future sensors will require an additional factor of 2 improvement to answer rigorously the science questions moving forward. Modest investments, defined through the CERES Science Team s 30-year operational history of the EOS CERES sensors, in onboard calibration hardware and pre-flight calibration and test program will ensure meeting these goals while reducing costs in re-processing scientific datasets. The CERES FM-5 pre-flight radiometric characterization program benefited from the 30-year operational experience of the CERES EOS sensors, as well as a stronger emphasis of radiometric characterization in the Statement of Work with the sensor provider. Improvements to the pre-flight program included increased spectral, spatial, and temporal sampling under vacuum conditions as well as additional tests to characterize the primary and transfer standards in the calibration facility. Future work will include collaboration with NIST to further enhance the understanding of the radiometric performance of this equipment prior to flight. The current effort summarizes these improvements to the CERES FM-5 pre-flight sensor characterization program, as well as modifications to inflight calibration procedures and operational tasking. In addition, an estimate of the impacts to the system level accuracy and traceability is presented.

Priestly, Kory↗

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Animal movement estimation and network-based epidemic modeling: Illustration for the swine industry in Iowa (US)

Animal movement plays a critical role in disease transmission between farms. However, in the United States, the lack of available animal shipment data, sometimes coupled with a lack of detailed information about farm demographics and characteristics, presents great challenges for epidemic modeling and prediction. In this study, we proposed a new method based on the maximum entropy to generate “synthetic” animal movement networks, considering available statistics about the premises operation type, operation size, and the distance between premises. We illustrated our method for the swine movement networks in Iowa and performed network analyses to gain insights into the swine industry. We then applied the generated networks to a network-based epidemic model to identify potential system vulnerabilities in terms of disease transmission. The model was parameterized for African Swine Fever (ASF) as the US swine industry is quite concerned about this disease. Results show that premises with a central role in the network are more vulnerable to disease outbreaks and play an important role in disease spread. Simulations with outbreaks starting from random farms reveal no significant large outbreaks, indicating the system’s relative robustness against arbitrary disease introductions. However, outbreaks originating from high out-degree farms can lead to large epidemic sizes. This underscores the importance for stakeholders and policymakers to continue improving animal movement records and traceability programs in the US and the value of making that data available to epidemiologists and modelers to better understand risk and inform strategies aimed to cost-effectively prevent and control disease transmission. Our approach could be easily adapted to estimate movement networks in other animal production systems and to inform disease spread models for various infectious diseases.

60 APPLIED LIFE SCIENCES↗

Highly Integrated Quality Assurance – An Empirical Case

Highly Integrated Quality Assurance – An Empirical Case Drake Kirkham1, Amy Powell2, Lucas Rich3 1Quality Manager, Radioisotope Power Systems (RPS) Program, Idaho National Laboratory, P.O. Box 1625 M/S 6122, Idaho Falls, ID 83415-6122 2Quality Engineer, RPS Program, Idaho National Laboratory 3Quality Engineer, RPS Program, Idaho National Laboratory Contact: Voice: (208) 533-7550 Email: Drake.Kirkham@inl.gov Abstract. The Radioisotope Power Systems Program of the Idaho National Laboratory makes an empirical case for a highly integrated Quality Assurance function pertaining to the preparation, assembly, testing, storage and transportation of 238Pu fueled radioisotope thermoelectric generators. Case data represents multiple campaigns including the Pluto/New Horizons mission, the Mars Science Laboratory mission in progress, and other related projects. Traditional Quality Assurance models would attempt to reduce cost by minimizing the role of dedicated Quality Assurance personnel in favor of either functional tasking or peer-based implementations. Highly integrated Quality Assurance adds value by placing trained quality inspectors on the production floor side-by-side with nuclear facility operators to enhance team dynamics, reduce inspection wait time, and provide for immediate, independent feedback. Value is also added by maintaining dedicated Quality Engineers to provide for rapid identification and resolution of corrective action, enhanced and expedited supply chain interfaces, improved bonded storage capabilities, and technical resources for requirements management including data package development and Certificates of Inspection. A broad examination of cost-benefit indicates highly integrated Quality Assurance can reduce cost through the mitigation of risk and reducing administrative burden thereby allowing engineers to be engineers, nuclear operators to be nuclear operators, and the cross-functional team to operate more efficiently. Applicability of this case extends to any high-value, long-term project where traceability and accountability are determining factors.

99 GENERAL AND MISCELLANEOUS↗

A Prototype Software to Demonstrate a Data Catalog for Hanford Environmental Datasets

Ensuring that data on long-term environmental remediation at the Hanford Site is high-quality, traceable, and easily accessible is an ongoing challenge, complicated by decades of data collection, multiple contractors maintaining data sources, and the wide range of data types. A centralized data catalog, known as the Hanford Environmental Information and Data Index (HEIDI), has been under development as part of the Hanford Environmental Data Management (HEDM) program to address these challenges. HEIDI fulfills a critical need to bring together a wide range of data types and sizes from multiple authoritative data sources, while documenting the data pedigree and quality information (i.e., traceable to the data source/originator). This document describes additional development and maturation of the HEIDI prototype. Key accomplishments included deploying the catalog software, Esri Geoportal Server, on a server accessible to Hanford Local Area Network users, conducting cybersecurity evaluations, investigating integrated authentication solutions, and conducting functional testing of the catalog prototype. The server-based deployment enabled targeted feedback, leading to enhancements including improved accessibility features and an expanded metadata schema. Specifications for the server-based deployment of the prototype catalog and the HEIDI metadata schema are provided in this document to support subsequent HEIDI deployment by the U.S. Department of Energy Richland Operations Office.

54 ENVIRONMENTAL SCIENCES↗

Effective Materials Property Information Management for the 21st Century

This paper discusses key principles for the development of materials property information management software systems. There are growing needs for automated materials information management in industry, research organizations and government agencies. In part these are fuelled by the demands for higher efficiency in material testing, product design and development and engineering analysis. But equally important, organizations are being driven to employ sophisticated methods and software tools for managing their mission-critical materials information by the needs for consistency, quality and traceability of data, as well as control of access to proprietary or sensitive information. Furthermore the use of increasingly sophisticated nonlinear, anisotropic and multi-scale engineering analysis approaches, particularly for composite materials, requires both processing of much larger volumes of test data for development of constitutive models and much more complex materials data input requirements for Computer-Aided Engineering (CAE) software. And finally, the globalization of engineering processes and outsourcing of design and development activities generates much greater needs for sharing a single gold source of materials information between members of global engineering teams in extended supply-chains. Fortunately material property management systems have kept pace with the growing user demands. They have evolved from hard copy archives, through simple electronic databases, to versatile data management systems that can be customized to specific user needs. The more sophisticated of these provide facilities for: (i) data management functions such as access control, version control, and quality control; (ii) a wide range of data import, export and analysis capabilities; (iii) mechanisms for ensuring that all data is traceable to its pedigree sources: details of testing programs, published sources, etc; (iv) tools for searching, reporting and viewing the data; and (v) access to the information via a wide range of interfaces, including web browsers, rich clients, programmatic access and clients embedded in third-party applications, such as CAE systems. This paper discusses the important requirements for advanced material data management systems as well as the future challenges and opportunities such as automated error checking, automated data quality assessment and characterization, identification of gaps in data, as well as functionalities and business models to keep users returning to the source: to generate user demand to fuel database growth and maintenance.

36 MATERIALS SCIENCE↗

Quasi-zero lattice mismatch and band alignment of BaTiO{sub 3} on epitaxial (110)Ge

Growth, structural, and band alignment properties of pulsed laser deposited amorphous BaTiO{sub 3} on epitaxial molecular beam epitaxy grown (110)Ge layer, as well as their utilization in low power transistor are reported. High-resolution x-ray diffraction demonstrated quasi-zero lattice mismatch of BaTiO{sub 3} on (110)Ge. Cross-sectional transmission electron microscopy micrograph confirms the amorphous nature of BaTiO{sub 3} layer as well as shows a sharp heterointerface between BaTiO{sub 3} and Ge with no traceable interfacial layer. The valence band offset, {Delta}E{sub v}, of 1.99 {+-} 0.05 eV at the BaTiO{sub 3}/(110)Ge heterointerface is measured using x-ray photoelectron spectroscopy. The conduction band offset, {Delta}E{sub c}, of 1.14 {+-} 0.1 eV is calculated using the bandgap energies of BaTiO{sub 3} of 3.8 eV and Ge of 0.67 eV. These band offset parameters for carrier confinement and the interface chemical properties of the BaTiO{sub 3}/(110)Ge system are significant advancement towards designing Ge-based p-and n-channel metal-oxide semiconductor field-effect transistors for low-power application.

36 MATERIALS SCIENCE↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluations of University of Wisconsin Silicon Carbide Temperature Monitors 300 LO and 400 LO B

Silicon carbide (SiC) temperature monitors 05R4-02-A KG1403 (300 LO) and 05R4-01-A KG1415 (400 LO B) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak irradiation temperatures. HTTL measurements indicate that the peak irradiation temperature for the 300 LO monitor was 295 {+-} 20 °C and the peak irradiation temperature for the 400 LO B monitor was 294 {+-} 25 °C. Two silicon carbide (SiC) temperature monitors irradiated in the Advanced Test Reactor (ATR) were evaluated at the High Temperature Test Lab (HTTL) to determine their peak temperature during irradiation. These monitors were irradiated as part of the University of Wisconsin Pilot Project with a target dose of 3 dpa. Temperature monitors were fabricated from high density (3.203 g/cm 3 ) SiC manufactured by Rohm Haas with a nominal size of 12.5 mm x 1.0 mm x 0.75 mm (see Attachment A). Table 1 provides identification for each monitor with an expected peak irradiation temperature range based on preliminary thermal analysis (see Attachment B). Post irradiation calculations are planned to reduce uncertainties in these calculated temperatures. Since the early 1960s, SiC has been used as a post-irradiation temperature monitor. As noted in Reference 2, several researchers have observed that neutron irradiation induced lattice expansion of SiC annealed out when the post-irradiation annealing temperature exceeds the peak irradiation temperature. As noted in Reference 3, INL uses resistivity measurements to infer peak irradiation temperature from SiC monitors. Figure 1 depicts the equipment at the HTTL used to evaluate the SiC monitors. The SiC monitors are heated in the annealing furnace using isochronal temperature steps that, depending on customer needs, can range from 50 to 800 °C. This furnace is located under a ventilation hood within the stainless steel enclosure. The ventilation system is activated during heating so that any released vapors are vented through this system. Annealing temperatures are recorded using a National Institute of Standards and Technology (NIST) traceable thermocouple inserted into an alumina tube in the furnace. After each isochronal annealing, the specimens are placed in a specialized fixture located in the constant temperature chamber (maintained at 30 °C) for a minimum of 30 minutes. After the 30 minute wait time, each specimen's resistance is measured using the specialized fixture and a calibrated DC power analyzer. This report discusses the evaluation of the SiC monitors and presents the results. Testing was conducted in accordance with Reference 3. Sections 2 and 3 present the data collected for each monitor and provide interpretation of the data. Section 4 presents the evaluated temperature results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Materials Scorecards, Phase 2: Advanced Materials and Manufacturing Technology

This report presents updated material score cards with detailed justification of the proposed rating provided and quantifies the readiness of the advanced manufacturing of materials for nuclear applications. Based on an expanded literature review of available data, the scores in this report (Phase 2) have either been modified or remained constant as compared with Phase 1 scoring. The rating justification are provided for each scoring criteria whereas the maturity quantification of additively manufactured alloys and the knowledge gaps are discussed with reference traceability. This report focuses on the detailed justification and traceability for the adoption of additively manufactured 316SS, SS304, Alloy 800H, Graphite C/C, Alloy N, Silicon Carbide, HT9, Alloy 617, and Alloy 718. Significant variability in data and knowledge gaps exist among the identified materials. The scorecards are therefore based on published literature data, industry response to a survey, stakeholder input collected at workshops, and expert opinion. The interpretation and assessment were somewhat challenged as experimental process parameters and methodology varied and best judgment was exercised for score quantification. This assessment reflects the overall level of technical maturity for AM materials and their deployment in Gen-VI nuclear systems. These Phase 2 scorecards are likely to be revised based on additional input from stakeholders and as new research results become available.

36 MATERIALS SCIENCE↗