Search NASA⌕ Search

SEARCH · Search NASA

Results for “selective heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9, 435, 011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

99 GENERAL AND MISCELLANEOUS↗

Fabrication and Testing of Solid-Solution Strengthened Corrosion Resistant Alloys For Service in Molten Fluoride Environments

The demand for higher system thermal efficiencies requires the operation of power generation cycles and heat conversion systems at progressively higher temperatures. As the system operating temperature increases, existing materials may not provide adequate mechanical properties or environmental compatibility or both. There is an increasing commercial interest in the development and deployment of liquid-fueled Molten Salt Reactors (MSRs). Hastelloy®N, the highest performing candidate MSR structural alloy, is not capable of operations at temperatures above 700°C, thus limiting the performance of these systems. Using an Integrated Computational Materials Engineering (ICME)-approach and small laboratory scale heats, ORNL developed a class of patented alloys covered by U.S. Patent 9,435,011 B2, “Creep-resistant, Cobalt-free alloys for high temperature, liquid-salt heat exchanger systems,” similar to Hastelloy®N in that they are primarily solid solution strengthened. In contrast to precipitation strengthened alloys, the microstructure of solid solution alloys and hence the high temperature mechanical properties are stable for extended periods of time allowing long reactor operating life. The new alloys have shown to possess good resistance to liquid fluorides at temperatures up to 850°C and have significantly improved creep properties when compared to Hastelloy®N. The purpose of the CRADA project was for ORNL to collaborate with Haynes International- a materials producer, MetalTek International- a foundry, and Kairos Power – an advanced reactor developer – to scale-up selected alloys, evaluate their properties, and identify one solid solution strengthened alloy that can meet the property requirements for the reactor being developed by Kairos Power and other similar liquid fluoride-salt cooled reactors. As part of the project, eight alloys were down-selected and fabricated in larger industrial scale heats by Haynes International. Resistance to molten salt was evaluated in flowing FLiNaK and FLiBe by Kairos Power using their Rotating Cage Loop (RCL) system. Accounting for iron deposition during these tests, the new alloys displayed very low net mass change showing excellent corrosion performance in molten salt. Creep properties evaluated at ORNL were found to be better than that of Hastelloy®N and 316 stainless steel. Long-term stabilities of the alloys evaluated by Haynes International showed that these alloys have excellent thermal stability in the temperature range 704.4-815.6°C, with the change in strength and ductility being less than 10-15% after a 4000-hour exposure at 815.6°C. Autogenously Gas Tungsten Arc Welding (GTAW) welded samples showed less than 10% change in yield strength / ultimate tensile strength / total elongation compared to the basemetal, indicating that the alloys have excellent weldability. Three parts were successfully investment-cast using one alloy with very little voiding showing feasibility of fabricating parts using the casting process. This project enabled extensive interaction between the material producer Haynes International, casting supplier MetalTek, and reactor developer Kairos Power. This facilitated testing of materials and components produced using the newly developed alloys by the end-user. This allowed the generation of critical dataset required for down-selection of a few promising alloys for further development. This data is also currently being shared with other reactor designers for them to evaluate the suitability of this alloy for their reactor design. The availability of this alloy will ultimately enable the design and development and deployment of MSRs with increased temperature of operation and thus, improved efficiencies.

36 MATERIALS SCIENCE↗

A Comparative Study of Ethanol Upgrading to Butadiene Over Rare Earth Elements Incorporated in Dealuminated Beta Zeolites

Copper and rare earth element-containing dealuminated Beta zeolites (CuREE/deAlBeta) are promising catalysts for the conversion of ethanol to C 3+ olefins en route to sustainable aviation fuel. Product selectivities over CuREE/deAlBeta depend on the identity of the REE. Here, in this study, a suite of La/deAlBeta catalysts of varied La loading are prepared, and their reactivities, selectivities, and apparent C-C coupling kinetics in the cascade reaction between ethanol and acetaldehyde are reported. Ex situ and in situ titrations to quantify Lewis acidic La sites quantify distinct numbers of sites, suggesting a distribution of site types. Across a series of REE/deAlBeta catalysts (REE = Y, La, Lu, Yb, Gd), the selectivity to secondary products correlates with the pyridine heats of adsorption at REE Lewis acid sites. The turnover frequency (per Lewis acid site) for C–C coupling was similar across the series of REE/deAlBeta catalysts. Y/deAlBeta and La/deAlBeta, which have the most disparate secondary product selectivities, had similar kinetics for C–C coupling. These findings demonstrate the complexity of quantifying active sites in REE/deAlBeta zeolites, and the sensitivity of the selectivity, but not the reactivity for C–C coupling, to the identity of the REE atom in REE/deAlBeta zeolites.

alcohol upgrading↗

Cyclic Thermal and Structural Testing of a Hot Particle Storage Bin

Thermal energy storage is a key element in concentrating solar energy systems. In 2017 a Roadmap toward a third-generation system that could meet the SunSHOT goals of 0.06 $/kWe recommended increasing temperatures to > 700° C for heat transfer media to in-crease thermal efficiencies and lower levelized costs of heat. In 2021, the U.S. Department of Energy selected the particle pathway, G3P3, to build a 1 MWt prototype solar tower with 6 MWh thermal energy storage at the NSTTF in Albuquerque, NM. Of the primary components, the falling particle receiver, and particle-to-sCO2 heat exchanger have been demonstrated at the 250 kWt capacity. The storage component is now being demonstrated as part of the G3P3-USA and G3P3-KSA pilot plants. Storage bin liner materials have been demonstrated by KSU in 2016 and 2019. A flowing particle storage container was demonstrated in 2020 by KSU. The testing presented in this work will be the first to test the particle to wall interactions with mono-lithic refractory insulation, and to validate a transient thermal transport model with the unique kinetics of bulk solids in funnel-flow where cooler particles near the walls flow inward toward a hot central flow channel. This work will also de-risk and characterize the specific design of the G3P3-USA storage bin.

Sment, Jeremy↗

CFD Simulation of Helium Flow Loop Test Section

A helium flow loop is being assembled at Oak Ridge National Laboratory to analyze heat transfer enhancement for systems such as blanket and divertor components. To efficiently identify optimum geometries for heat transfer enhancement in these applications, simulation work is performed to optimize test section designs that are built and tested in the helium flow loop that operates at 4 MPa and a mass flow rate of 100 g/s. Different ribbed geometries that examine rib shape, rib height, rib orientation, rib spacing, and three dimensional orientation are modeled and simulated in STAR-CCM+ to compare their ability to remove heat and mitigate pressure drop. Following the simulations, models are selected and manufactured for the helium flow loop tests. Simulations initially focus on a hydrodynamic study to determine the appropriate mesh and physics models and then add a heat flux to analyze the heat transfer abilities of the models. The simulations are run in steady state and use a Reynolds-averaged Navier-Stokes k-ε turbulence model. The helium is modeled as an ideal gas. The simulation explores models of geometries that enhance the heat transfer and decrease pressure drop with an overall goal of increasing fluid collision with the wall. Enhanced geometries are simulated to select appropriate designs for manufacturing, and preliminary experimental results are used to validate the simulations. Furthermore, the factors that are being analyzed in the comparison between the experimental and the simulated results include matching thermocouple temperatures, pressure drop, roughness, and fluid velocity.

42 ENGINEERING↗

Outdoor Testing of c-Si Photovoltaic Modules with Spectrally-Selective Mirrors for Operating Temperature Reduction

The efficiency of a c-Si cell drops with increasing cell temperature. A typical photovoltaic module with a c-Si cell will operate 20-30K above ambient temperature. Spectrally-selective photonic mirrors which reflect sub-bandgap light can reduce waste heat generated by parasitic absorption in the module and reduce module operating temperature. Here, a spectrally selective 4-layer and 12-layer mirror are designed and fabricated on module cover glass. When integrated into modules, these mirrors reduce the operating temperature of the module by 0.16K and 1.5K, respectively when compared to a module with bare outer glass.

14 SOLAR ENERGY↗

Oilwell Conversion (Well API 121913310501) to Geothermal Heat Storage Well for Flexible Electricity Storage

Geothermal growth is limited by a lack of geographically dispersed high-temperature thermal resources and high initial upfront investment in characterization and well construction. This project intended to address the challenges of energy supply intermittency and enhance grid resilience, reliability, and energy security by storing energy provided from currently available renewable resources in the subsurface to harvest it a later time during at-peak energy demand. This project intended to improve geothermal adoption, reduce initial project risk, and improve price competitiveness through utilizing existing oil and gas infrastructure such as non-productive wells, non-economic fields, dry holes, and orphaned wells. The project also intended to address the lack of geographically dispersed thermal resources and enhance grid resilience, reliability, and energy security by introducing an economical method for storing energy from currently available renewable resources in the subsurface for usage during at-peak energy demand. During this research, the project furthered the understanding of the feasibility of utilizing abandoned oil and gas wells as geothermal heat storage wells. The project team investigated the heat storage and hydrogeological characteristics of subsurface reservoirs in the Illinois Basin to evaluate their response to heat injection for determining the evolution of temperature profiles and heat losses over time using existing and available data sets. The project team then performed modeling and simulation to evaluate the heat losses of returning fluids during heat extraction. The outputs were used to select an optimal candidate reservoir and location in Southern Illinois. The team designed and performed a small-scale field test in an existing oil well to refine the model and to demonstrate the permitting and regulatory pathways necessary for the conversion of oil and gas assets to geothermal use. The field test also serves as a proof of concept and can guide the procedures for future research and implementation. Additionally, the project team, conducted initial market research and customer discovery to develop a go to market strategy for an Advanced Geothermal Energy Storage (AGES) system. The project team in this research also identified the parameters to be refined in future research, to improve the current go to market strategy economic model. To this end several subject matter experts were also identified to assist in future research with geothermal infrastructure setup, energy storage policy and law, energy storage market demand, potential siting based on demand etc. Future research will involve further sophistication of the site commercial modeling, implementing a larger-scale test, and further refinement of the thermodynamic modeling/simulation process. The output will be lifecycle costs and economics suitable for comparison to alternative approaches from a validated full-scale demonstration for venture capital investment into this technology. The project successfully demonstrated the ability to leverage existing oilfield infrastructure, permits, and land access and leasing agreements, to enable geothermal storage projects to come online faster and cheaper than a greenfield development could. This technology could allow for greater energy independence and security through long-term energy storage solutions. The longer duration allows for greater storage for renewables currently limited by hours-long storage durations of lithium-ion. The AGES system would support the growth of renewable energy farms, and provide greater opportunities for a cleaner energy infrastructure.

15 GEOTHERMAL ENERGY↗

The structure of sc16 GaP obtained at 17.5 GPa and 1400 K

We report using a laser-heated diamond anvil cell, a powdered sample of gallium phosphide was compressed to 17.5 GPa and heated up to 1400 K. The material obtained was characterized at room temperature using synchrotron x-ray diffraction. Experimental results were compared with first-principles calculations. The polymorph observed assumes the simple cubic structure (sc16) initially reported for GaAs at high pressures. Microdiffraction mapping showed variable grain sizes of the synthesized phase, with the largest grains located in the middle of the heated spot. Structural refinements were performed on selected grains. The structure predicted based on first-principles calculations is in close agreement with the experiments. The two Ga–P bonds show similar lengths in sc16-GaP; however, the bond angles differ, resulting in a distorted tetrahedral coordination geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A rapid assay for assessing bacterial effects on Arabidopsis thermotolerance

Abstract Background The role of beneficial microbes in mitigating plant abiotic stress has received considerable attention. However, the lack of a reproducible and relatively high-throughput screen for microbial contributions to plant thermotolerance has greatly limited progress in this area, this slows the discovery of novel beneficial isolates and the processes by which they operate. Results We designed a rapid phenotyping method to assess the effects of bacteria on plant host thermotolerance. After testing multiple growth conditions, a hydroponic system was selected and used to optimize an Arabidopsis heat shock regime and phenotypic evaluation. Arabidopsis seedlings germinated on a PTFE mesh disc were floated onto a 6-well plate containing liquid MS media, then subjected to heat shock at 45 °C for various duration. To characterize phenotype, plants were harvested after four days of recovery to measure chlorophyll content. The method was extended to include bacterial isolates and to quantify bacterial contributions to host plant thermotolerance. As an exemplar, the method was used to screen 25 strains of the plant growth promoting Variovorax spp. for enhanced plant thermotolerance. A follow-up study demonstrated the reproducibility of this assay and led to the discovery of a novel beneficial interaction. Conclusions This method enables rapid screening of individual bacterial strains for beneficial effects on host plant thermotolerance. The throughput and reproducibility of the system is ideal for testing many genetic variants of Arabidopsis and bacterial strains.

59 BASIC BIOLOGICAL SCIENCES↗

Substrate Effects When Using Photons to Make Perovskite Solar Cells

To shorten annealing time and minimize substrate heating, flash lamps that deliver short, intense light pulses, commonly called photonic curing, are used to replace thermal annealing using hot plates or ovens. This method is different from equilibrium heating in that the radiant energy is selectively absorbed by the film. The high-intensity light pulses produce a high peak temperature in the film. Because most processes follow Arrhenius behavior, reaching high temperatures allow chemical reactions/phase transformations to occur in a short time, significantly reducing the processing time. Often the results are non-intuitive. We will present fabricating flexible halide perovskite solar cells (PSCs) on indium tin oxide (ITO) coated Willow glass. The effect of ITO transmittance on the photonic curing of nickel nitrate sol-gel precursors into nickel oxide to fabricate hole transport layer and consequently the performance of PSCs. Unexpectedly, ITO samples processed by photonic curing show improved optical and electrical properties.

14 SOLAR ENERGY↗

Thermal Management for a Novel Non-Heavy Rare-Earth Interior Permanent Magnet Machine

The work presents a thermal management solution for a novel non-heavy rare-earth permanent magnet machine being developed at Oak Ridge National Laboratory. The motor has been designed to minimize losses while maximizing performance for a range of speeds and power ratings. The novel motor design reduces rare-earth magnet usage, thereby avoiding supply chain issues. The motor component heat losses are established for operating windows and desired performance. These heat losses, along with windage losses, are being used to develop cooling solutions for different components of this machine. A novel thermal management solution for stators and rotors has been developed, and progress is presented in this paper. The stator cooling is achieved with the help of water-ethylene glycol flowing over the finned aluminum stator jacket, and rotor cooling with automatic transmission fluid passing through novel channels designed in the rotor laminations. The attempt is to establish effective cooling of the stator winding, laminations, and rotor magnets. A 3D conjugate heat transfer model has been developed for overall thermal analysis to establish a down- selected thermal management solution for the machine. The model, in addition to estimated component heat losses, includes windage losses and its impact on rotor and stator cooling. Overall, the work presents a workable thermal solution for the interior permanent magnet machine with potential for further improvements. Future work will involve establishing end winding and refinement of other end parts of the machine with the aim of establishing a robust thermal management solution. The work will also focus on different shapes (e.g., round, non-round, presence of wedges) of rotor-stator gaps and investigate windage losses and their impact on thermal management for higher rotational speeds for the machine.

30 DIRECT ENERGY CONVERSION↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Optical Forces on an Oscillating Dipole Near VO2 Phase Transition

We investigate optical forces on oscillating dipoles close to a phase change vanadium dioxide (VO2) film, which exhibits a metal-insulator transition around 340 K and low thermal hysteresis. This configuration emulates the interaction between an illuminated nanosphere and an interface and we employ a classical description to capture its important aspects. We consider both electric and magnetic dipoles for two different configurations, namely with the dipole moments parallel and perpendicular to the VO2 film. By using Bruggeman theory to describe the effective optical response of the material, we show that the thermal hysteresis present in the VO2 transition clearly shows up in the behavior of optical forces. In the near-field regime, the force on both dipoles can change from attractive to repulsive just by heating (or cooling) the film for a selected frequency range. We also verified that the optical forces are comparable to the Casimir-Polder force in a similar system, revealing the possibility of modulating or even changing the sign of the resultant force on an illuminated nano-object due to the presence of a thermochromic material. We hope that this work contributes to set the grounds for alternative approaches to control light-matter interactions using phase-change materials.

36 MATERIALS SCIENCE↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

New heat flux model for non-axisymmetric divertor infrared structures

A convective heat flux model for perturbed plasmas, based on guiding center ion drift in vacuum elds (A. Wingen, et al., Phys. Plasmas 21 (2014) 012509), has been updated. The old model only considered ion heat flux, while here also electron heat flux is included. The updated model predicts divertor heat flux distributions in non-axisymmetric (3D) plasmas with applied Resonant Magnetic Perturbation (RMP) fields, and includes electric scalar potentials. It is found that a radial electric field in the near Scrape-o Layer (SOL) can considerably shift the footprints toroidally, leading to a smearing out eff ect of the incident heat flux, while a simple model for sheath potential has little impact on footprints. Various approaches to model electron heat flux are studied. A convective electron model, based on collisionless free streaming, is found to yield the best agreement with measurements, while a conductive model requires a at temperature gradient inside lobes to yield acceptable peak heat ux values. A heuristic heat flux layer approach, based on a fixed layer width also requires a limited heat flux inside the last closed flux surface (LCFS); by selecting various locations of the LCFS, the results of the conductive or convective model can be recovered respectively. The sum of ion and electron heat fluxes, both obtained by the convective model, is compared to experimental data for multiple time slices in DIII-D. Strike point splitting is observed with peak heat fluxes and layer widths that compare well to infrared camera (IR) measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗