Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Matrix-free subcell residual distribution for Bernstein finite elements: Monolithic limiting

This paper is focused on the aspects of limiting in residual distribution (RD) schemes for high-order finite element approximations to advection problems. Both continuous and discontinuous Galerkin methods are considered in this work. Discrete maximum principles are enforced using algebraic manipulations of element contributions to the global nonlinear system. The required modifications can be carried out without calculating the element matrices and assembling their global counterparts. The components of element vectors associated with the standard Galerkin discretization are manipulated directly using localized subcell weights to achieve optimal accuracy. Low-order nonlinear RD schemes of this kind were originally developed to calculate local extremum diminishing predictors for flux-corrected transport (FCT) algorithms. In the present paper, we incorporate limiters directly into the residual distribution procedure, which makes it applicable to stationary problems and leads to well-posed nonlinear discrete problems. To circumvent the second-order accuracy barrier, the correction factors of monolithic limiting approaches and FCT schemes are adjusted using smoothness sensors based on second derivatives. Finally, the convergence behavior of presented methods is illustrated by numerical studies for two-dimensional test problems.

97 MATHEMATICS AND COMPUTING↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

Sublimation temperature sensor for temperature locale

The sublimation temperature sensor (or “sublime sensor”) provides a continuum of measurement locations in which certain maximum temperatures are achieved during a heat up/cool down cycle. A predetermined material is encapsulated within a vacuum-sealed, non-volatile long tube (i.e., both ends capped and L$\gg$ D). This assembly is then inserted and centered into a heated zone, such as a furnace, exhaust pipe, or reactor. As the temperature increases, the material will sublimate (i.e., a process of having both the solid and gaseous states of matter simultaneously present) and will begin to fill the void - moving outward in both directions toward the ends of the tube. Once beyond the elevated temperatures, the gas will de-sublimate (i.e., deposition) onto the inner wall of the tube. The desired result of the sensor is the ring of material that develops over a relatively short period of time. This material deposit can be equated with temperature at an exact location. There is no need to interpolate and/or extrapolate for the desired measurement. Accuracy has been recorded for temperature locations on the range of ±2 mm over a 1 m span. Likewise, the precision of the measurement is ±0.2% the overall sensor domain. Furthermore, individual tubes with unique materials and pressures can be bundled together to provide a complete temperature profile of the heated zone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling the Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

An important need for coal fired power plants is the ability to monitor multiple systems with ease and accuracy. Common implementations of these monitoring systems come with drawbacks due to the nature of coal fired power plants. Harsh environments, High Temperatures, and lots of RF (Radio Frequency) noise can create issues for accurately recording and transmitting data across wireless signals. In addition, as renewable energy sources come online, existing fossil fueled plants will need to operate more flexibly with their maintenance schedules outside of standard conditions. Therefore, additional sensing and control mechanisms need placed in existing plants to provide operators with more information such that maintenance decisions can be made well in advance of failures. A solution to this problem is the Next Generation of Smart Sensors, which leverages the power of 5G cellular signals and machine learning to overcome the myriad of problems with current implementations

20 FOSSIL-FUELED POWER PLANTS↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model calibration of the liquid mercury spallation target using evolutionary neural networks and sparse polynomial expansions

The mercury constitutive model predicting the strain and stress in the target vessel plays a central role in improving the lifetime prediction and future target designs of the mercury targets at the Spallation Neutron Source. We leverage the experiment strain data collected over multiple years to improve the mercury constitutive model through a combination of large scale simulations of the target behavior and the use of machine learning tools for parameter estimation. We present two interdisciplinary approaches for surrogate-based model calibration of expensive simulations using evolutionary neural networks and sparse polynomial expansions. The newly calibrated simulations achieve 7% average improvement on the prediction accuracy and 8% reduction in mean absolute error compared to previously reported reference parameters, with some individual sensors experiencing up to 30% improvement. The calibrated simulations can aid in fatigue analysis to estimate the mercury target lifetime, which reduces abrupt failure and saves tremendous amount of costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

A review of machine learning in building load prediction

The surge of machine learning in recent years has been empowering engineer modeling in various fields. The decreasing hardware cost, increasing data accessibility, and advances of building automation system (BAS) allow the collection and storage of a significant amount of building operation data. The two facts provide great opportunities of applying machine learning to building energy systems modeling and analysis. There are a great number of research papers on this topic but there lacks a comprehensive and general review to summarize the current development, limitations, gaps and future trend. In this review paper series, machine learning techniques in building energy system modeling and analysis are reviewed under the organization and logic of the machine learning definition by Tom M. Mitchell: a computer program is said to learn from experience E with respect to some class of tasks T and performance measure P if its performance at tasks in T, as measured by P, improves with experience E. This paper is the first part of the review paper series, which focuses on building load prediction. First, the applications of building load prediction model (task T) are reviewed. Then, the modeling algorithms improving machine learning performance and accuracy (performance P) are reviewed. At the same time, the literature on the data perspective for modeling (experience E), including data engineering from sensors level to data level, pre-processing, feature extraction and selection, is reviewed. Finally, what is well-studied and what is lacking but with great potential are concluded; the gaps between present and future utilization of machine learning techniques are identified; the future trend and development are also predicted. The target readers of this paper are not only researchers from the building side who can get exposed to cutting edge machine learning tools, but also those from machine learning side who can understand the potential and challenge to apply machine learning in buildings.

Liang, Zhang↗

Real-time Object Bounding in LiDAR Data With Computer Vision

The Multimodal Measurement System is a roadside radiation measurement testbed used to detect radiation sources in passing vehicles. It works by combining sensor signals from various modalities to produce a thorough scan of the source. A LiDAR sensor is used to measure the dimensions of the vehicle and provide a velocity estimate. However, the current LiDAR setup uses propriety software for which the source code is unavailable and cannot be updated to improve performance. Therefore, it is imperative to the accuracy of the analysis to create a custom vehicle detection that can return the dimensions and velocity of passing vehicles in real time. This new custom detection is written in C++ using the PointCloud Library, which keeps it lightweight. It also utilizes Docker and the Robot Operating System, which allows the versatility of running both on a small computer or the Lawrence Livermore National Laboratory cluster while utilizing different models of LiDAR sensors. The custom detection outperforms the current detection model, which increases the accuracy of radiation source detection.

97 MATHEMATICS AND COMPUTING↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Embedded Sensing in Additive Manufacturing Metal and Polymer Parts: A Comparative Study of Integration Techniques and Structural Health Monitoring Performance

This study presents a comparative evaluation of post-process sensor integration in additively manufactured (AM) metal and the in-situ process for polymer structures for structural health monitoring (SHM), with an emphasis on embedded sensors. Geometrically identical specimens were fabricated using copper via metal fused filament fabrication (FFF) and PLA via polymer FFF, with piezoelectric transducers (PZTs) inserted into internal cavities to assess the influence of material and placement on sensing fidelity. Mechanical testing under compressive and point loads generated signals that were transformed into time–frequency spectrograms using a Short-Time Fourier Transform (STFT) framework. An engineered RGB representation was developed, combining global amplitude scaling with an amplitude-envelope encoding to enhance contrast and highlight subtle wave features. These spectrograms served as inputs to convolutional neural networks (CNNs) for classification of load conditions and detection of damage-related features. Results showed reliable recognition in both copper and PLA specimens, with CNN classification accuracies exceeding 95%. Embedded PZTs were especially effective in PLA, where signal damping and environmental sensitivity often hinder surface-mounted sensors. This work demonstrates the advantages of embedded sensing in AM structures, particularly when paired with spectrogram-based feature engineering and CNN modeling, advancing real-time SHM for aerospace, energy, and defense applications.

additive manufacturing↗

Adamantine 1.0: A Thermomechanical Simulator for Additive Manufacturing

Adamantine is a thermomechanical simulation code that is written in C++ and built on top of deal.II (Arndt et al., 2023), p4est (Burstedde et al., 2011), ArborX (Lebrun-Grandié et al., 2020), Trilinos (The Trilinos Project Team, 2020), and Kokkos (Trott et al., 2022). Adamantine was developed with additive manufacturing in mind and it is particularly well adapted to simulate fused filament fabrication, directed energy deposition, and powder bed fusion. Adamantine employs the finite element method with adaptive mesh refinement to solve a nonlinear anisotropic heat equation, enabling support for various additive manufacturing processes. It can also perform elastoplastic and thermoelastoplastic simulations. It can handle materials in three distinct phases (solid, liquid, and powder) to accurately reflect the physical state during different stages of the manufacturing process. To enhance simulation accuracy, adamantine incorporates data assimilation techniques (Asch et al., 2016). This allows it to integrate experimental data from sensors like thermocouples and infrared (IR) cameras. This combined approach helps account for errors arising from input parameters, material properties, models, and numerical calculations, leading to more realistic simulations that reflect what occurs in a particular print.

36 MATERIALS SCIENCE↗

Lidar - HilFlowS - LLNL ZephIR300 - MOP - Processed Data

The ZephIR300 is a continuous wave LIDAR with a range of 10 m to 300 m. During HilFlowS the ZephIR300 was programmed to measure from 10 m to 150 m. In addition, the ZephIR300 provided a measurement at 1 m height using an onboard meteorological sensor. The ZephIR300 has a 30° scanning cone angle, data sampling rate of approximately 15 s, wind speed accuracy of 0.5 percent, and direction accuracy of 0.5°.

17 WIND ENERGY↗

Lidar - HilFlowS - LLNL ZephIR300 - WOP - Processed Data

The ZephIR300 is a continuous wave LIDAR with a range of 10 m to 300 m. During HilFlowS the ZephIR300 was programmed to measure from 10 m to 150 m. In addition, the ZephIR300 provided a measurement at 1 m height using an onboard meteorological sensor. The ZephIR300 has a 30° scanning cone angle, data sampling rate of approximately 15 s, wind speed accuracy of 0.5 percent, and direction accuracy of 0.5°.

17 WIND ENERGY↗