Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Snow survey and vegetation growth in high mountains (Swiss Alps) and additional ERTS investigations in Switzerland

The author has identified the following significant results. Two different methods, an analog and a digital one, have been developed for rapid and accurate mapping of the areal extent and changes in snow cover in high mountains. The quick-look method is based on individual visual control of each image using a photo quantizer which provides exact references for density slicing with high resolution lith-film. The digital snow classification system is based on discriminant analysis with the data of the four multispectral bands as variables and contains all preprocessing, feature extraction, and mapping steps for an operational application. Two different sets of sampling groups were established which apply to different conditions of snow cover. The first one serves for the normal situation with a uniform dry and new cover. The second one serves for situations with partly thawing and/or frozen snow.

Haefner, H.↗

Polycrystal Plasticity: Comparison Between Grain - Scale Observations of Deformation and Simulations

Here, the response of polycrystals to plastic deformation is studied at the level of variations within individual grains, and comparisons are made to theoretical calculations using crystal plasticity (CP). We provide a brief overview of CP and a review of the literature, which is dominated by surface observations. The motivating question asks how well does CP represent the mesoscale behavior of large populations of dislocations (as carriers of plastic strain). The literature shows consistently that only moderate agreement is found between experiment and calculation. We supplement this with a current example of microstructure evolution in the interior of a copper sample subjected to tensile deformation. Nondestructive measurements of orientation fields were performed using the near-field high-energy X-ray diffraction microscopy (nf-HEDM) technique at the Advanced Photon Source (APS). Starting at highly ordered grains, a single two-dimensional slice of microstructure containing ~150 grains was followed through multiple strain states, where it tracked lattice rotations and defect accumulation of up to 14% elongation. In accord with the literature, at the scale of individual grains, comparison of observations with CP models indicates reasonable qualitative agreement but significant variations between simulation and experiment are apparent. The conclusion is that in order to be able to quantify the effects of microstructure on the distributions of slip, orientation change, and damage accumulation, the empirically derived constitutive relations used in continuum-scale simulations need to be improved. Equally important will be the development of large-scale simulations of polycrystals that directly model dislocations.

36 MATERIALS SCIENCE↗

Spatial Pattern of Cell Damage in Tissue from Heavy Ions

A new Monte Carlo algorithm was developed that can model passage of heavy ions in a tissue, and their action on the cellular matrix for 2- or 3-dimensional cases. The build-up of secondaries such as projectile fragments, target fragments, other light fragments, and delta-rays was simulated. Cells were modeled as a cell culture monolayer in one example, where the data were taken directly from microscopy (2-d cell matrix). A simple model of tissue was given as abstract spheres with close approximation to real cell geometries (3-d cell matrix), as well as a realistic model of tissue was proposed based on microscopy images. Image segmentation was used to identify cells in an irradiated cell culture monolayer, or slices of tissue. The cells were then inserted into the model box pixel by pixel. In the case of cell monolayers (2-d), the image size may exceed the modeled box size. Such image was is moved with respect to the box in order to sample as many cells as possible. In the case of the simple tissue (3-d), the tissue box is modeled with periodic boundary conditions, which extrapolate the technique to macroscopic volumes of tissue. For real tissue, specific spatial patterns for cell apoptosis and necrosis are expected. The cell patterns were modeled based on action cross sections for apoptosis and necrosis estimated based on BNL data, and other experimental data.

Ponomarev, Artem L.↗

SPS Ecloud Instabilities - Analysis of Machine Studies and Implications for Ecloud Feedback

The SPS at high intensities exhibits transverse single bunch instabilities with signatures consistent with an Ecloud driven instability. We present recent MD data from the SPS, details of the instrument technique and spectral analysis methods which help reveal complex vertical motion that develops within a subset of the injected bunch trains. The beam motion is detected via wideband exponential taper striplines and delta-sigma hybrids. The raw sum and difference data is sampled at 50 GHz with 1.8 GHz bandwidth. Sliding window FFT techniques and RMS motion techniques show the development of large vertical tune shifts on portions of the bunch of nearly 0.025 from the base tune of 0.185. Results are presented via spectrograms and bunch slice trajectories to illustrate development of the unstable beam and time scale of development along the injected bunch train. The study shows that the growing unstable motion occupies a very broad frequency band of 1.2 GHz. These measurements are compared to numerical simulation results, and the system parameter implications for an Ecloud feedback system are outlined.

43 PARTICLE ACCELERATORS↗

SPS ECLOUD INSTABILITIES - ANALYSIS OF MACHINE STUDIES AND IMPLICATIONS FOR ECLOUD FEEDBACK

The SPS at high intensities exhibits transverse single-bunch instabilities with signatures consistent with an Ecloud driven instability. They present recent MD data from the SPS, details of the instrument technique and spectral analysis methods which help reveal complex vertical motion that develops within a subset of the injected bunch trains. The beam motion is detected via wideband exponential taper striplines and delta-sigma hybrids. The raw sum and difference data is sampled at 50 GHz with 1.8 GHz bandwidth. sliding window FFT techniques and RMS motion techniques show the development of large vertical tune shifts on portions of the bunch of nearly 0.025 from the base tune of 0.185. Results are presented via spectrograms and bunch slice trajectories to illustrate development of the unstable beam and time scale of development along the injected bunch train. The study shows that the growing unstable motion occupies a very broad frequency band of 1.2 GHz. These measurements are compared to numerical simulation results, and the system parameter implications for an Ecloud feedback system are outlined.

60 APPLIED LIFE SCIENCES↗

El-CID: a filter for gravitational-wave electromagnetic counterpart identification

ABSTRACT As gravitational-wave (GW) interferometers become more sensitive and probe ever more distant reaches, the number of detected binary neutron star mergers will increase. However, detecting more events farther away with GWs does not guarantee corresponding increase in the number of electromagnetic counterparts of these events. Current and upcoming wide-field surveys that participate in GW follow-up operations will have to contend with distinguishing the kilonova (KN) from the ever increasing number of transients they detect, many of which will be consistent with the GW sky-localization. We have developed a novel tool based on a temporal convolutional neural network architecture, trained on sparse early-time photometry and contextual information for Electromagnetic Counterpart Identification (El-CID). The overarching goal for El-CID is to slice through list of new transient candidates that are consistent with the GW sky localization, and determine which sources are consistent with KNe, allowing limited target-of-opportunity resources to be used judiciously. In addition to verifying the performance of our algorithm on an extensive testing sample, we validate it on AT2017gfo – the only EM counterpart of a binary neutron star merger discovered to date – and AT2019npv – a supernova that was initially suspected as a counterpart of the GW event, GW190814, but was later ruled out after further analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Geographic applications of ERTS-1 imagery to rural landscape change in eastern Tennessee

There are no author-identified significant results in this report. A multistage sampling experiment was conducted using low (10,000') and high (60,000') altitude aircraft imagery in comparison with orbital (560 miles) ERTS imagery. Although the aircraft data provide detailed landscape observations similar to ground truth data, they cover relatively small areas per image frame for irregular static slices of time. By comparison, ERTS provides repetitive observations in a regional perspective for broad areal coverage. Microdensitometric and computer techniques are being used to analyze the ERTS imagery for gray tone signatures, comparisons, and ultimately for landscape change detection.

Rehder, J. B.↗

Sensitivity and uncertainty analysis for a combined depletion and criticality calculation chain of a BWR FA

This paper examines the prerequisites and boundary conditions for extending burnup credit from pressurized water reactors to boiling water reactors with validated depletion codes by performing uncertainty and sensitivity analyses on a modern boiling water reactor fuel assembly design. We developed a computational chain consisting of an axial boiling water reactor axial irradiation model, followed by a series of depletion calculations and a three-dimensional criticality calculation. The irradiation model puts into relation the profiles of power, burnup and moderator density of the fuel assembly at 24 axial locations. In a simplified fashion it also includes the insertion of control blades. The depletion calculations of the fuel assembly were performed in axial slices with the 2D-depletion code HELIOS 1.12. The criticality calculations were done in 3D-geometry with KENO-Va from the SCALE 6.2.1 package, in which several fuel assemblies are placed into a generic transport cask. For the uncertainty and sensitivity analyses a Monte Carlo sampling based approach is used applying the GRS tool SUnCISTT. We performed several generic investigations testing the capabilities and the limitations of the whole computational chain. The impact of variations of the irradiation model on the resulting reactivity of the fuel assemblies inside a transport cask or storage pool was investigated using an uncertainty and sensitivity analysis on the whole computational chain. Geometrical uncertainties were also included in the evaluation and a parameter study on the use of control blades during irradiation was performed. The goal was to develop the procedures and tools to be able to obtain quantitative uncertainty data which can be used in the future to derive conservative irradiation profiles without unnecessary excess reactivity margins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A silicon sheet casting experiment

The casting of silicon blanks for solar cells directly without slicing is an exciting concept. An experiment was performed to investigate the feasibility of developing a machine that casts wafers directly. A Czochralski furnace was modified to accept a graphite ingot-simulating fixture. Silicon was melted in the middle of the ingot simulator in a boron nitride mold. Sample castings showed reasonable crystal size. Solar cells were made from the cast blanks. The performance is reported.

Bickler, D. B.↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-01: A Data-Driven 4D-MRI Motion Model to Estimate Full Field-Of-View Abdominal Motion From 2D Image Navigators During MR-Linac Treatment

Purpose: To estimate full field-of-view abdominal respiratory motion from fast 2D image navigators using a 4D-MRI based motion model. This will allow for radiation dose accumulation mapping during MR-Linac treatment. Methods: Experiments were conducted on a Philips Ingenia 1.5T MRI. First, a retrospectively ordered 4D-MRI was constructed using 3D transient-bSSFP with radial in-plane sampling. Motion fields were calculated through 3D non-rigid registration. From these motion fields a PCA-based abdominal motion model was constructed and used to warp a 3D reference volume to fast 2D cine-MR image navigators that can be used for real-time tracking. To test this procedure, a time-series consisting of two interleaved orthogonal slices (sagittal and coronal), positioned on the pancreas or kidneys, were acquired for 1m38s (dynamic scan-time=0.196ms), during normal, shallow, or deep breathing. The coronal slices were used to update the optimal weights for the first two PCA components, in order to warp the 3D reference image and construct a dynamic 4D-MRI time-series. The interleaved sagittal slices served as an independent measure to test the model’s accuracy and fit. Spatial maps of the root-mean-squared error (RMSE) and histograms of the motion differences within the pancreas and kidneys were used to evaluate the method. Results: Cranio-caudal motion was accurately calculated within the pancreas using the model for normal and shallow breathing with an RMSE of 1.6mm and 1.5mm and a histogram median and standard deviation below 0.2 and 1.7mm, respectively. For deep-breathing an underestimation of the inhale amplitude was observed (RMSE=4.1mm). Respiratory-induced antero-posterior and lateral motion were correctly mapped (RMSE=0.6/0.5mm). Kidney motion demonstrated good motion estimation with RMSE-values of 0.95 and 2.4mm for the right and left kidney, respectively. Conclusion: We have demonstrated a method that can calculate dynamic 3D abdominal motion in a large volume, while acquiring real-time cine-MR images for MR-guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors

Purpose: To provide methods for quantification of uncertainties in 4-dimensional (4D) treatment during treatment planning. Methods and Materials: Uncertainty information was generated by multiple 4D treatment simulations with varying parameters. Sampled data were analyzed using uncertainty visualization methods that have been added to common treatment plan evaluation methods (eg, dose-volume histogram and dose distribution analysis). To illustrate the potential of the introduced methods, uncertainty analysis was completed for a single lung cancer case using 3 motion mitigation techniques: gating, slice-by-slice rescanning, and breath-controlled rescanning. Results: By repeating 4D dose calculations with varying parameters, we were able to show local uncertainties in dose distributions and to evaluate the stability of treatment setups. The new methods were found suitable for uncertainty evaluation in 4D treatment planning of moving tumors. Calculation time of the uncertainty base data was time consuming but contrivable overnight. Conclusions: Uncertainty analysis and visualization for 4D treatment planning provide an important tool in the decision process for an optimal treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beyond Fisher forecasting for cosmology

The planning and design of future experiments rely heavily on forecasting to assess the potential scientific value provided by a hypothetical set of measurements. The Fisher information matrix, due to its convenient properties and low computational cost, provides an especially useful forecasting tool. However, the Fisher matrix only provides a reasonable approximation to the true likelihood when data are nearly Gaussian distributed and observables have nearly linear dependence on the parameters of interest. Also, Fisher forecasting techniques alone cannot be used to assess their own validity. Thorough sampling of the exact or mock likelihood can definitively determine whether a Fisher forecast is valid, though such sampling is often prohibitively expensive. Here we propose a simple test, based on the Derivative Approximation for likelihoods (DALI) technique, to determine whether the Fisher matrix provides a good approximation to the exact likelihood. We show that the Fisher matrix becomes a poor approximation to the true likelihood in regions where two-dimensional slices of level surfaces of the DALI approximation to the likelihood differ from two-dimensional slices of level surfaces of the Fisher approximation to the likelihood. We demonstrate that our method accurately predicts situations in which the Fisher approximation deviates from the true likelihood for various cosmological models and several data combinations, with only a modest increase in computational cost compared to standard Fisher forecasts.

79 ASTRONOMY AND ASTROPHYSICS↗

Flight Software Dictionary Development for the Mars2020 Rover

The Mars2020 project, developed and operated by the Jet Propulsion Laboratory (JPL), successfully landed the Perseverance rover and its flying companion Ingenuity on the surface of Mars on February 18th 2021. Perseverance combines heritage and cutting-edge flight software and hardware to accomplish crucial mission requirements related to Martian surface sampling. The design, development, and operation of NASA’s large strategic science missions require the ability to communicate spacecraft capabilities to hundreds of engineers across multiple disciplines. The interaction between flight and ground software development, Verification and Validation (V&V), Assembly, Test, and Launch Operations (ATLO), and management each demand quick understanding of unique slices of information for each discipline. This information includes the current capabilities of the flight system as well as future capabilities and their status as they are developed and tested. Despite the fundamental and critical nature of this information, the flight software dictionaries used to track it are a stumbling block for many projects. These dictionaries provide the cornerstone for the interpretation of data sent from the spacecraft, allowing for quick comprehension by engineers on the ground. During both spacecraft development and operations, flight software dictionary management includes significant challenges due to the large number of interfacing systems and the subtle yet distinct needs of each.The engineering of flight software dictionaries for Mars2020 had numerous challenges, most-notably: parallel dictionary development to support simultaneous separate flight software build campaigns for each mission phase (cruise and surface), managing requests for operations-enabling information without perturbing the heritage interface with the rover, and the introduction of new tools by the dictionary stakeholders that forced the dictionary team to innovate and redesign the heritage tool chain. These challenges generated guiding principles for the dictionary development effort: emphasize coding best practices and unit testing in the dictionary code development tool chain, use institutionally provided COTS (commercial-off-the-shelf) tools whenever possible, and maintain the heritage flight-ground interface all while advancing operations-enabling information via a loosely coupled interface.Throughout development and operations, the Mars2020 dictionary toolchain included IBM DOORS Next Generation, GitHub, Microsoft Excel, Docker, Jenkins, and a significant custom-built Python codebase. Significant interfaces included JPL’s command and control software, heritage flight software team tools and processes, and the many cloud-based ground tools developed for the mission.This paper will discuss the requirements for the Mars2020 dictionary development, the development team’s response to those requirements, lessons learned throughout the process, steps taken towards automated deliveries and continuous integration of stakeholder inputs, potential toolchain improvements for Mars2020, and key takeaways that could be applied to future missions.

Pyrzak, Guy↗

A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues.Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface processing for bulk niobium superconducting radio frequency cavities

The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single-or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies on real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and 'nitrogen doping' of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

THE DEPENDENCE OF STAR FORMATION RATES ON STELLAR MASS AND ENVIRONMENT AT z approx 0.8

We examine the star formation rates (SFRs) of galaxies in a redshift slice encompassing the z = 0.834 cluster RX J0152.7 - 1357. We used a low-dispersion prism in the Inamori Magellan Areal Camera and Spectrograph to identify galaxies with z {sub AB} < 23.3 mag in diverse environments around the cluster out to projected distances of approx8 Mpc from the cluster center. We utilize a mass-limited sample (M > 2 x 10{sup 10} M{sub sun}) of 330 galaxies that were imaged by Spitzer MIPS at 24 mum to derive SFRs and study the dependence of specific SFR (SSFR) on stellar mass and environment. We find that the SFR and SSFR show a strong decrease with increasing local density, similar to the relation at z approx 0. Our result contrasts with other work at z approx 1 that finds the SFR-density trend to reverse for luminosity-limited samples. These other results appear to be driven by star formation (SF) in lower mass systems (M approx 10{sup 10} M{sub sun}). Our results imply that the processes that shut down SF are present in groups and other dense regions in the field. Our data also suggest that the lower SFRs of galaxies in higher density environments may reflect a change in the ratio of star-forming to non-star-forming galaxies, rather than a change in SFRs. As a consequence, the SFRs of star-forming galaxies, in environments ranging from small groups to clusters, appear to be similar and largely unaffected by the local processes that truncate SF at z approx 0.8.

79 ASTRONOMY AND ASTROPHYSICS↗