Search NASA⌕ Search

SEARCH · Search NASA

Results for “slicing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Shift-and-invert parallel spectral transformation eigensolver: Massively parallel performance for density-functional based tight-binding

The Shift-and-invert parallel spectral transformations (SIPs), a computational approach to solve sparse eigenvalue problems, is developed for massively parallel architectures with exceptional parallel scalability and robustness. The capabilities of SIPs are demonstrated by diagonalization of density-functional based tight-binding (DFTB) Hamiltonian and overlap matrices for single-wall metallic carbon nanotubes, diamond nanowires, and bulk diamond crystals. The largest (smallest) example studied is a 128,000 (2000) atom nanotube for which ~330,000 (~5600) eigenvalues and eigenfunctions are obtained in ~190 (~5) seconds when parallelized over 266,144 (16,384) Blue Gene/Q cores. Weak scaling and strong scaling of SIPs are analyzed and the performance of SIPs is compared with other novel methods. Different matrix ordering methods are investigated to reduce the cost of the factorization step, which dominates the time-to-solution at the strong scaling limit. As a result, a parallel implementation of assembling the density matrix from the distributed eigenvectors is demonstrated.

36 MATERIALS SCIENCE↗

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medium grain niobium SRF cavity production technology for science frontiers and accelerator applications

Herein we present the cost-effective production of superconducting radio frequency (SRF) cavities made of medium grain (MG) niobium (Nb) discs directly sliced from forged and annealed billet. This production method provides clean surface conditions and reliable mechanical characteristics with sub-millimeter average grain size resulting in stable SRF cavity production. We propose to apply this material to particle accelerator in the science and industrial applications. The science applications require high field gradients(≥ 30 MV/m) particularly in pulsed mode. The industrial applications require high $Q_0$ values with moderate gradients (~ 20 MV/m) in CW mode operation. This paper describes the MG Nb disc production recently demonstrated and discusses future prospects for application in advanced particle accelerators in the science and industrial applications.

47 OTHER INSTRUMENTATION↗

SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

60 APPLIED LIFE SCIENCES↗

LSA Large Area Silicon Sheet Task Enhanced I.D. Slicing Technology for Silicon Ingots

Development of inside diameter slicing technology to significantly increase the number of useable slices per inch of crystal over industry practice is discussed. The required reduction of both blade and slice thickness is to be accomplished by a combination of three key elements of slicing technology: (1) ingot rotation with minimum exposed blade area; (2) dynamic cutting edge control; and (3) the use of prefabricated insert blades. Design modifications on a slicing saw with microprocessor controls and hardware fabrication to complete this conversion were initiated. Several runs were conducted on the engineering saw incorporating the method of ingot rotation. Ingots with diameters up to six inches were sliced successfully on a production saw.

Walters, D.↗

Low-cost conversion of polycrystalline silicon into sheet by HEM and FAST

The conversion of polycrystalline silicon to sheet form (the wafers produced are 10 cm x 10 cm cross section with minimum surface damage) by the Heat Exchanger Method (HEM) and multi-wire Fixed Abrasive Slicing Technique (FAST), as a means of reducing the cost of solar arrays for adaptation of photovoltaic technology for terrestrial applications, is given. A schematic of a HEM furnace, which includes a silica crucible, and developments in the HEM process are presented. A new machine for slicing with wire was designed and fabricated. The high-speed slicer has been used to slice 19 wafers per cm from 10 cm diameter crystals. Both HEM and FAST are low-cost processes and they have the potential of giving one of the lowest add-on costs ($6.24 and $6.48 per square meter of sheet respectively, with the combination add-on cost of $14.87 per square meter) of this conversion.

Khattak, C. P.↗

Meteoroid and debris special investigation group; status of 3-D crater analysis from binocular imagery

During the 3 month deintegration of the LDEF, the M&D SIG generated approximately 5000 digital color stereo image pairs of impact related features from all space exposed surfaces. Currently, these images are being processed at JSC to yield more accurate feature information. Work is currently underway to determine the minimum number of data points necessary to parametrically define impact crater morphologies in order to minimize the man-hour intensive task of tie point selection. Initial attempts at deriving accurate crater depth and diameter measurements from binocular imagery were based on the assumption that the crater geometries were best defined by paraboloid. We made no assumptions regarding the crater depth/diameter ratios but instead allowed each crater to define its own coefficients by performing a least-squares fit based on user-selected tiepoints. Initial test cases resulted in larger errors than desired, so it was decided to test our basic assumptions that the crater geometries could be parametrically defined as paraboloids. The method for testing this assumption was to carefully slice test craters (experimentally produced in an appropriate aluminum alloy) vertically through the center resulting in a readily visible cross-section of the crater geometry. Initially, five separate craters were cross-sectioned in this fashion. A digital image of each cross-section was then created, and the 2-D crater geometry was then hand-digitized to create a table of XY position for each crater. A 2nd order polynomial (parabolic) was fitted to the data using a least-squares approach. The differences between the fit equation and the actual data were fairly significant, and easily large enough to account for the errors found in the 3-D fits. The differences between the curve fit and the actual data were consistent between the caters. This consistency suggested that the differences were due to the fact that a parabola did not sufficiently define the generic crater geometry. Fourth and 6th order equations were then fitted to each crater cross-section, and significantly better estimates of the crater geometry were obtained with each fit. Work is presently underway to determine the best way to make use of this new parametric crater definition.

Sapp, Clyde A.↗

Moving target irradiation with fast rescanning and gating in particle therapy

Purpose: In moving target irradiation with pencil beam scanning, the interplay effect between the target motion and the scanned beam is a problem because this effect causes over or under dosage in the target volume. To overcome this, we have studied rescanning using a gating technique. Methods: A simulation and experimental study was carried out. In the experiment, we used the fast scanning system developed at the HIMAC to verify the validity of phase controlled rescanning method, in which the time for rescanning irradiation of each slice is matched to the gating duration. Results: Simulation and experimental results showed that controlling the scan speed to match the respiration cycle with rescans can deliver the blurred dose distribution. In the comparison between the static measurements and the moving measurements with the phase controlled rescanning method, the dose difference was less than 2% for pinpoint chambers in the target volume. Conclusions: The simulation and experimental results demonstrated that the phase controlled rescanning method makes it possible to deliver the dose distribution close to the expected one. As an experimental result for 3D irradiation, it was estimated that blurring by the probability density function was not only for a lateral distribution, but also for a distal distribution, even in the lateral rescanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-E-18A-11: Fluoro-Tomographic Images From Projections of On-Board Imager (OBI) While Gantry Is Moving

Purpose: A method to generate a series of fluoro-tomographic images (FTI) of the slice of interest (SOI) from the projection images of the On-board imager (OBI) while gantry is moving is developed and tested. Methods: Tomographic image via background subtraction, TIBS has been published by our group. TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). We extended the idea to 4D TIBS, which enables to generate from the projection of different gantry angles. A set of background images for different angles are prepared. A background image at a given gantry angle is subtracted from the projection image at the same angle to generate a TIBS image. Then the TIBS image is converted to a reference angle. The 4D TIBS is the set of TIBS that originated from gantry angles other than the reference angle. Projection images of lung patients for CBCT acquisition are used to test the 4D TIBS. Results: Fluoroscopic images of a coronal plane of lung patients are acquired from the CBCT projections at different gantry angles and times. Change of morphology of hilar vessels due to breathing and heart beating are visible in the coronal plane, which are generated from the set of the projection images at gantry angles other than antero-posterior. Breathing surrogate or sorting process is not needed. Unlike tomosynthesis, FTI from 4D TIBS maintains the independence of each of the projections thereby reveals temporal variations within the SOI. Conclusion: FTI, fluoroscopic imaging of a SOI with x-ray projections, directly generated from the x-ray projection images at different gantry angles is tested with a lung case and proven feasible. This technique can be used for on-line imaging of moving targets. NIH Grant R01CA133539.

60 APPLIED LIFE SCIENCES↗

MULTILEVEL MONTE CARLO (MLMC) SIMULATIONS: PERFORMANCE RESULTS FOR SPE10 (XY SLICES)

In this report we first describe a generic multilevel Monte Carlo method and then illustrate its superior performance over a traditional single-level Monte Carlo method for second order elliptic PDEs corresponding to two-dimensional layers in (x, y)-direction of the Tenth SPE Comparative Solution project (SPE 10) which gives high-contrast permeability coefficients. The SPE10 data set is used as a coarse level in the Monte Carlo method and the respective permeability coefficient k (provided in the SPE10 dataset) is used as a mean in the simulation. The actual coefficients are drawn based on a KL-expansion assuming that the log-mean is perturbed by a log-normal distributed samples.

97 MATHEMATICS AND COMPUTING↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compression Analytics for Classification and Anomaly Detection within Network Communication

Here, the flexibility of network communication within Internet protocols is fundamental to network function, yet this same flexibility permits the possibility of malicious use. In particular, malicious behavior can masquerade as benign traffic, thus evading systems designed to catch misuse of network resources. However, perfect imitation of benign traffic is difficult, meaning that small unintentional deviations from normal can occur. Identifying these deviations requires that the defenders know what features reveal malicious behavior. Herein we present an application of compression-based analytics to network communication that can reduce the need for defenders to know a priori what features they need to examine. Motivating the approach is the idea that compression relies on the ability to discover and make use of predictable elements in information, thereby highlighting any deviations between expected and received content. We introduce a so-called “slice compression” score to identify malicious or anomalous communication in two ways. First, we apply normalized compression distances (NCDs) to classification problems and discuss methods for reducing the noise by excising application content (as opposed to protocol features) using slice compression. Second, we present a new technique for anomaly detection, referred to as slice compression for anomaly detection (SCADe). A diverse collection of datasets are analyzed to illustrate the efficacy of the proposed approaches. While our focus is network communication, other types of data are also considered to illustrate the generality of the method.

97 MATHEMATICS AND COMPUTING↗

SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

60 APPLIED LIFE SCIENCES↗

SU-F-I-36: In-Utero Dose Measurements Within Postmortem Subjects for Estimating Fetal Doses in Pregnant Patients Examined with Pulmonary Embolism, Trauma, and Appendicitis CT

Purpose: The imaging of pregnant patients is medically necessary in certain clinical situations. The purpose of this work was to directly measure uterine doses in a cadaver scanned with CT protocols commonly performed on pregnant patients in order to estimate fetal dose and assess potential risk. Method: One postmortem subject was scanned on a 320-slice CT scanner with standard pulmonary embolism, trauma, and appendicitis protocols. All protocols were performed with the scan parameters and ranges currently used in clinical practice. Exams were performed both with and without iterative reconstruction to highlight the dose savings potential. Optically stimulated luminescent dosimeters (OSLDs) were inserted into the uterus in order to approximate fetal doses. Results: In the pulmonary embolism CT protocol, the uterus is outside of the primary beam, and the dose to the uterus was under 1 mGy. In the trauma and appendicitis protocols, the uterus is in the primary beam, the fetal dose estimates were 30.5 mGy for the trauma protocol, and 20.6 mGy for the appendicitis protocol. Iterative reconstruction reduced fetal doses by 30%, with uterine doses at 21.3 for the trauma and 14.3 mGy for the appendicitis protocol. Conclusion: Fetal doses were under 1 mGy when exposed to scatter radiation, and under 50 mGy when exposed to primary radiation with the trauma and appendicitis protocols. Consistent with the National Council on Radiation Protection & Measurements (NCRP) and the International Commission on Radiological Protection (ICRP), these doses exhibit a negligible risk to the fetus, with only a small increased risk of cancer. Still, CT scans are not recommended during pregnancy unless the benefits of the exam clearly outweigh the potential risk. Furthermore, when possible, pregnant patients should be examined on CT scanners equipped with iterative reconstruction in order to keep patient doses as low as reasonable achievable.

60 APPLIED LIFE SCIENCES↗

Proceedings of the Second NASA Formal Methods Symposium

This publication contains the proceedings of the Second NASA Formal Methods Symposium sponsored by the National Aeronautics and Space Administration and held in Washington D.C. April 13-15, 2010. Topics covered include: Decision Engines for Software Analysis using Satisfiability Modulo Theories Solvers; Verification and Validation of Flight-Critical Systems; Formal Methods at Intel -- An Overview; Automatic Review of Abstract State Machines by Meta Property Verification; Hardware-independent Proofs of Numerical Programs; Slice-based Formal Specification Measures -- Mapping Coupling and Cohesion Measures to Formal Z; How Formal Methods Impels Discovery: A Short History of an Air Traffic Management Project; A Machine-Checked Proof of A State-Space Construction Algorithm; Automated Assume-Guarantee Reasoning for Omega-Regular Systems and Specifications; Modeling Regular Replacement for String Constraint Solving; Using Integer Clocks to Verify the Timing-Sync Sensor Network Protocol; Can Regulatory Bodies Expect Efficient Help from Formal Methods?; Synthesis of Greedy Algorithms Using Dominance Relations; A New Method for Incremental Testing of Finite State Machines; Verification of Faulty Message Passing Systems with Continuous State Space in PVS; Phase Two Feasibility Study for Software Safety Requirements Analysis Using Model Checking; A Prototype Embedding of Bluespec System Verilog in the PVS Theorem Prover; SimCheck: An Expressive Type System for Simulink; Coverage Metrics for Requirements-Based Testing: Evaluation of Effectiveness; Software Model Checking of ARINC-653 Flight Code with MCP; Evaluation of a Guideline by Formal Modelling of Cruise Control System in Event-B; Formal Verification of Large Software Systems; Symbolic Computation of Strongly Connected Components Using Saturation; Towards the Formal Verification of a Distributed Real-Time Automotive System; Slicing AADL Specifications for Model Checking; Model Checking with Edge-valued Decision Diagrams; and Data-flow based Model Analysis.

Munoz, Cesar↗

Analysis and evaluation in the production process and equipment area of the low-cost solar array project

Analyses of slicing processes and junction formation processes are presented. A simple method for evaluation of the relative economic merits of competing process options with respect to the cost of energy produced by the system is described. An energy consumption analysis was developed and applied to determine the energy consumption in the solar module fabrication process sequence, from the mining of the SiO2 to shipping. The analysis shows that, in current technology practice, inordinate energy use in the purification step, and large wastage of the invested energy through losses, particularly poor conversion in slicing, as well as inadequate yields throughout. The cell process energy expenditures already show a downward trend based on increased throughput rates. The large improvement, however, depends on the introduction of a more efficient purification process and of acceptable ribbon growing techniques.

Goldman, H.↗