Search NASA⌕ Search

SEARCH · Search NASA

Results for “smart building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Collaborative Decision Approach for Electricity Pricing-demand Response Stackelberg Game

Demand response programs are considered as a valuable resource in smart grids that provide several advantages of load shifting, peak load reduction, mediating intermittency of renewable energy integration, etc. Flexible price-based incentives have been recognized as a critical strategy in motivating and compensating consumers' load adjustment actions for successful implementation of demand response. Game theoretical approaches, especially Stackelberg games are popularly adopted to model the relationship between electricity price and customers' demand response and solved by the classical centralized backward induction (BI) method. However, the BI method generally requires convexity of the follower's model for necessary optimality conditions, and the computational time of any centralized approach increases sharply with larger problem instances. In this paper, the Stackelberg game of electricity pricing-demand response between a distribution system operator (DSO) and load aggregators (LAs) is decomposed based on a collaborative optimization (CO) framework, where each LA is treated as a discipline with its own domain constraints (e.g. building temperature control), while the DSO at the system level tries to reduce the solution discrepancy and guide the searching towards optimality. Several groups of comparison experiments have demonstrated the effectiveness of the proposed collaborative decision approach in solving the demand response game.

Chen, Yang↗

Inertia Emulation Control using Demand Response via 5G Communications

Building energy equipment is moving rapidly towards Internet of Things (IoT)-driven devices to provide consumer connectivity and device management. These device-level interfaces along with 5G communications will be leveraged to develop control architectures to engage a large number of monitoring and control devices and provide real-time and reliable energy services. Emerging 5G networks have high potential to provide the communication technology for demand response, with fast transfer speed, high reliability, and high number of connections. Guaranteed inertial response to limit frequency fluctuations is one of the main challenges in modern power systems due to the increased penetration of renewable generation, and it is largely affected by communication delays and packet losses. This paper analyzes inertial response and rate of change of frequency in a power system model with inverter-interfaced air conditioners. The control loop considers time delays and packet losses to show the need to switch to 5G networks in future smart grids.

Morovati, Samaneh↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned in Building the Ares Projects

Since being established in 2005, the Ares Projects at Marshall Space Flight Center have been making steady progress designing, building, testing, and flying the next generation of exploration launch vehicles. Ares is committed to rebuilding crucial capabilities from the Apollo era that made the first human flights to the Moon possible, as well as incorporating the latest in computer technology and changes in management philosophy. One example of an Apollo-era practice has been giving NASA overall authority over vehicle integration activities, giving civil service engineers hands-on experience in developing rocket hardware. This knowledge and experience help make the agency a "smart buyer" of products and services. More modern practices have been added to the management tool belt to improve efficiency, cost effectiveness, and institutional knowledge, including knowledge management/capture to gain better insight into design and decision making; earned value management, where Ares won a NASA award for its practice and implementation; designing for operability; and Lean Six Sigma applications to identify and eliminate wasted time and effort. While it is important to learn technical lessons like how to fly and control unique rockets like the Ares I-X flight test vehicle, the Ares management team also has been learning important lessons about how to manage large, long-term projects.

Sumrall, John Phil↗

Lighting Automation - Flying an Earthlike Habitat

Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.

Clark, Tori A.↗

Lighting Automation Flying an Earthlike Habitat

Currently, spacecraft lighting systems are not demonstrating innovations in automation due to perceived costs in designing circuitry for the communication and automation of lights. The majority of spacecraft lighting systems employ lamps or zone specific manual switches and dimmers. This type of 'hardwired' solution does not easily convert to automation. With advances in solid state lighting, the potential to enhance a spacecraft habitat is lost if the communication and automation problem is not tackled. If we are to build long duration environments, which provide earth-like habitats, minimize crew time, and optimize spacecraft power reserves, innovation in lighting automation is a must. This project researched the use of the DMX512 communication protocol originally developed for high channel count lighting systems. DMX512 is an internationally governed, industry-accepted, lighting communication protocol with wide industry support. The lighting industry markets a wealth of hardware and software that utilizes DMX512, and there may be incentive to space certify the system. Our goal in this research is to enable the development of automated spacecraft habitats for long duration missions. To transform how spacecraft lighting environments are automated, our project conducted a variety of tests to determine a potential scope of capability. We investigated utilization and application of an industry accepted lighting control protocol, DMX512 by showcasing how the lighting system could help conserve power, assist with lighting countermeasures, and utilize spatial body tracking. We hope evaluation and the demonstrations we built will inspire other NASA engineers, architects and researchers to consider employing DMX512 "smart lighting" capabilities into their system architecture. By using DMX512 we will prove the 'wheel' does not need to be reinvented in terms of smart lighting and future spacecraft can use a standard lighting protocol to produce an effective, optimized and potentially earthlike habitat.

Clark, Toni A.↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Integrated Architecture Study for Autonomous Lunar Construction

Lunar construction is an expanding field within NASA’s Moon to Mars objectives that presents many challenges and requires innovative and reliable forms of autonomous operations on the surface of the Moon to further the technologies needed for human space exploration. Marshal Space Flight Center’s (MSFC) Advanced Concepts Office (ACO) addressed Lunar Infrastructure Objective LI-4 l by developing a Pre-Phase A, integrated architecture to inform a demonstration for lunar construction operations. The ACO study traded three architectures that would survey and prepare a construction area to build a landing pad out of lunar regolith using MMPACT (Moon-to-Mars Planetary Autonomous Construction Technology) platforms, rovers, and navigation outposts. The main trades examined navigation for the system/architecture, options for rover navigation, battery vs continuous tether power for the MMPACT robotic arm, and assigning site prep functionality to the rovers vs the platforms. Results of the study determined that the best options for the scenario provided would be local navigation (more accurate and continuous), a combination of Light Detection and Ranging (LiDAR) for initial site mapping with subsequent Smart Video Guidance Sensors (SVGS) to save power for construction, and using tethered power to decrease mission duration. The team also concluded that assigning site prep functionality to either the rovers or the platforms has benefits and challenges; future studies could explore having that functionality on both the rovers and platforms. Lastly, the team provided a Concept of Operations (ConOps) timeline that can be used in real-time ground demonstrations to explore the mission timeline, construction processes, autonomous operations, and communication systems that can be tested using MSFC’s lunar regolith field and Lunar Utilization Control Area (LUCA).

Sarah Triana↗

Increasing Flight Software Reuse with OpenSatKit

In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospace's command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for users to extend the FSW functionality to meet their mission-specific requirements. The platform abstraction layer and the cFE layers go a step further than smart phones by providing a platform-agnostic Application Programmer Interface (API) that allows applications to run unchanged on different platforms. OpenSatKit can serve two significant architectural roles that will further help the adoption of the cFS and help create a community of users that can share assets. First, the kit is being enhanced to automate the integration of applications with the goal of creating a virtual cFS "App Store".. Second, a platform certification test suite can be developed that would allow users to verify the port of the cFS to a new platform. This paper will describe the current state of these efforts and future plans.

Computer Programming and Software↗

Increasing Flight Software Reuse with OpenSatKit

In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospaceâ€"TM"s command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for userâ€"TM"s to extend the FSW functionality to meet their mission-specific requirements. The platform abstraction layer and the cFE layers go a step further than smart phones by providing a platform-agnostic Application Programmer Interface (API) that allows applications to run unchanged on different platforms. OpenSatKit can serve two significant architectural roles that will further help the adoption of the cFS and help create a community of users that can share assets. First, the kit is being enhanced to automate the integration of applications with the goal of creating a virtual cFS 'App Store'. Second, a platform certification test suite can be developed that would allow users to verify the port of the cFS to a new platform. This paper will describe the current state of these efforts and future plans.

McComas, David↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Natural Gas Community of the Future (Final Report)

Nicor Gas, a subsidiary of Southern Company Gas and its parent company Southern Company, is developing the concept of the Carbon-neutral, Affordable, Resilient, and Equitable Community ("CARE Community") to address the challenges of accessibility and affordability of grid-interactive efficient buildings in historically disadvantaged communities. The CARE Community is a new construction net-zero energy and carbon neutral residential neighborhood consisting of 50 homes with electricity and natural gas services in South Suburban Chicago, built as low-income affordable housing. The National Renewable Energy Laboratory (NREL) is assisting Southern Company to explore how energy efficiency, renewable technologies, and the reliability and resilience of natural gas can be combined and optimized in an islandable energy system as part of a broader effort to understand the role natural gas plays in future communities integrated with renewable energy and improved energy efficiency. The CARE Community will demonstrate how energy efficiency, distributed energy resources (DERs), and advanced controls can be combined with existing natural gas infrastructure to serve historically disadvantaged communities in a cold climate with low energy cost for affordable housing programs and enhanced resilience to withstand extreme weather. Homes will be a part of an islandable energy system, integrating multiple DER technologies such as solar panels, natural gas fuel cells, reciprocating natural gas engines, and battery storage. The CARE Community will provide a replicable template that affordable housing developers and energy companies can adopt throughout the United States. In this report, we present the design and modeling of the community and potential approaches for integrating DERs. We analyze and discuss annual simulations under normal operating conditions and week-long simulations under electric power grid outage conditions.

03 NATURAL GAS↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Rapid Response Radiation Survey (R3S) Mission Using the HiSat Conformal Satellite Architecture

The Rapid Response Radiation Survey (R3S) experiment, designed as a quick turnaround mission to make radiation measurements in Low Earth Orbit (LEO), will fly as a hosted payload in partnership with NovaWurks using their Hyper-integrated Satlet (HISat) architecture. The need for the mission arises as the Nowcast of Atmospheric Ionization Radiation for Aviation Safety (NAIRAS) model moves from a research effort into an operational radiation assessment tool. Currently, airline professionals are the second largest demographic of radiation workers and to date their radiation exposure is undocumented in the USA. The NAIRAS model seeks to fill this information gap. The data collected by R3S, in addition to the complementary data from a NASA Langley Research Center (LaRC) atmospheric balloon mission entitled Radiation Dosimetry Experiment (RaD-X), will validate exposure prediction capabilities of NAIRAS. The R3S mission collects total dose and radiation spectrum measurements using a Teledyne μDosimeter and a Liulin-6SA2 LED spectrometer. These two radiation sensors provide a cross correlated radiometric measurement in combination with the Honeywell HMR2300 Smart Digital Magnetometer. The magnetometer assesses the Earth's magnetic field in the LEO environment and allows radiation dose to be mapped as a function of the Earth's magnetic shielding. R3S is also unique in that the radiation sensors will be exposed on the outer surface of the spacecraft, possibly making this the first measurements of the LEO radiation environment with bare sensors. Viability of R3S as an extremely fast turnaround mission is due, in part, to the nature of the robust, well-defined interfaces of the conformal satellite HiSat Architecture. The HiSat architecture, which was developed with the support of the Defense Advanced Research Projects Agency's (DARPA's) Phoenix Program, enabled the R3S system to advance from the first concept to delivery of preliminary design review (PDR) level documents in 29 calendar days. The architecture allows for interface complexities between the specific devices and the satellite bus to be resolved in a standardized interface control document (ICD). The ICD provided a readymade framework to interface to the modular satellite bus. This modularity allowed for approximately 90% of the R3S system to be designed and fabricated in two months without constraint of the hosting satellite's development cycle. This paper discusses the development of the R3S experiment as made possible by use of the HiSat architecture. The system design and operational modes of the experiment are described, as well as the experiment interfaces to the HiSat satellite via the user defined adapter (UDA) provided by NovaWurks. This paper outlines the steps taken by the project to execute the R3S mission in the 4 months of design, build, and test. Additionally portrayed is the ground work done at LaRC to posture the organization for a fast response and the process by which the opportunity was identified as aligning with key strategic goals. Finally, a description of the engineering process is provided, including the use of facilitated rapid/concurrent engineering sessions, the associated documentation, and the review process employed.

Miller, Nathanael A.↗