Search NASA⌕ Search

SEARCH · Search NASA

Results for “sources molecular spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

205 records · Page 12

Impact of Arsenic- and Indium-Terminated InGaAs Stressors on Carrier Confinement, Strain, Defects, and Transport Properties of Tensile-Strained Ge

Device-quality tensile-strained Ge (ε-Ge) grown on a large bandgap semiconductor with superior electrical and optical carrier confinement is essential for group-IV-based optoelectronics. Properties of ε-Ge active layers synthesized on In 0.24 Ga 0.76 As buffers with two different surface terminations─arsenic-rich and indium-rich─were experimentally demonstrated, highlighting the factors not considered in theoretical calculations. High-resolution X-ray diffraction and Raman spectroscopy analyses of these ε-Ge/In 0.24 Ga 0.76 As heterostructures confirmed the fully strained (1.6%) and partially relaxed (0.82%) nature of the ε-Ge bonded with arsenic-terminated (Ge As-terminated ) and indium-terminated (Ge In-terminated ) In 0.24 Ga 0.76 As stressors, respectively. High-resolution cross-sectional transmission electron microscopy showed a coherent, sharp, and fully strained ε-Ge/In 0.24 Ga 0.76 As heterointerface in the Ge As-terminated heterostructure, whereas microtwin defects were present in the Ge In-terminated heterostructure. These heterostructures were further characterized by evaluating the minority carrier lifetimes, high for Ge As-terminated (525 ns) and low for Ge In-terminated (69 ns), using the photoconductive decay technique. Moreover, band alignment was constructed using X-ray photoelectron spectroscopy, where the Ge As-terminated heterostructure revealed that both holes and electrons were confined within the ε-Ge active layer as a type-I band alignment with ΔE V, As-terminated = 0.22 eV and ΔE C,As-terminated = 0.38 eV. On the other hand, the Ge In-terminated heterostructure exhibited a type-II band alignment with ΔE V,In-terminated = – 0.02 eV and ΔE C,In-terminated = 0.53 eV. Furthermore, the magnetotransport properties revealed high mobility (321 cm 2 /(V s)) with single-electron transport in Ge As-terminated heterostructure and low mobility (3.34 cm 2 /(V s)) with multihole transport in the Ge In-terminated heterostructure. Therefore, preferring the ε-Ge on the arsenic-rich surface of In 0.24 Ga 0.76 As stressor over the indium-rich surface during material synthesis offers device-quality materials with high carrier lifetime and superior carrier confinement, which can provide an opportunity to fabricate efficient group-IV-based optoelectronic devices.

36 MATERIALS SCIENCE↗

High-resolution infrared spectroscopy of supersonically cooled singlet carbenes: Bromomethylene (HCBr) in the CH stretch region

First high-resolution spectra of cold (~35 K) singlet bromomethylene HCBr in the CH stretching (v 1 ) region from 2770 to 2850 cm-1 are reported using near quantum shot-noise limited laser absorption methods in a slit jet supersonic discharge expansion source. Three rovibrational bands are identified at high S/N (20:1 - 40:1) and rotationally assigned to i) the CH stretch fundamental (v 1 ) band $\tilde{X}$(1,0,0) ← $\tilde{X}$ (0,0,0) and ii) vibrational hot bands ($\tilde{X}$(1,1,0) ← $\tilde{X}$(0,1,0) and $\tilde{X}$(1,0,1) ← $\tilde{X}$(0,0,1)) arising from vibrationally excited HCBr populated in the discharge with single quanta in either the H–C–Br bend (v 2 ) or C–Br stretch (v 3 ) modes. Precision rotational constants are reported for a total of six states, with an experimentally determined CH stretch vibrational frequency (2799.38 cm -1 ) in good agreement with previous low-resolution fluorescence studies. Detailed analysis of the fundamental v 1 band highlights the presence of perturbations in the $\tilde{X}$(1,0,0) level, which we tentatively attribute to arise from the nearby triplet state $\tilde{a}$(0,0,1) through spin-orbit interaction or the multiple quanta $\tilde{X}$(0,2,1) singlet state via c-type Coriolis coupling. Reduced-Doppler resolution (60 MHz) in the slit-jet IR spectrometer permits clear observation of nuclear spin hyperfine structure, with experimental line shapes well reproduced by nuclear quadrupole/spin-rotation coupling constants from microwave studies. Lastly, the a-type to b-type transition intensity ratio for the fundamental CH stretch band is notably larger than predicted by a bond-dipole model, which from high level ab initio quantum calculations (CCSD(T)/PVQZ) can be attributed to vibrationally induced “charge-sloshing” of electron density along the polar C–Br bond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Pressure Synthesis of Ultrasmall Nanodiamonds with Nitrogen Vacancy Centers

C–H terminated nanometer scale diamonds ( d = 1 to 15 nm) are synthesized from 1-fluoroadamantane at high pressure (6–8 GPa) and high temperature (500–1500 °C) in a multianvil press. High resolution transmission electron microscopy, X-ray diffraction, Raman, diffuse reflectance Fourier transform infrared, and X-ray absorption spectroscopies demonstrate the excellent crystallinity and atomically flat C–H terminated surfaces of nanodiamonds with (111) and (110) facets. The importance of hydrogen to the synthesis of nanodiamond and its faceting is discussed. Following vacancy generation, annealing and oxidation of the nanodiamonds, optically detected magnetic resonance and electron spin resonance coherence times ( T 2 = 0.9 and 2.1 μs) of nitrogen vacancy (NV) centers are measured. Finally, the obtained T 2 values are equivalent to the shallow NV centers (depth <10 nm) in bulk diamond crystals and larger nanocrystals prepared by mechanical milling.

36 MATERIALS SCIENCE↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Thermodynamic phase transitions of nematic order in magnetic helices

A nematic phase lacks translation order but has orientational order. Nematic phases have been discovered in a variety of systems, including liquid crystals, correlated materials, and superconductors. Here, we report on a magnetic nematic phase, where the basis components are composed of magnetic helices. We directly probed the order parameters associated with the magnetic helices using resonant soft x-ray scattering and find two distinct nematic phases with complex spatiotemporal signatures. Using x-ray correlation spectroscopy, we find that near the phase boundary between the two nematic phases, fluctuations coexist on multiple disparate timescales. Our micromagnetic simulations and density functional theory calculations show that the fluctuations occur concomitantly with a reorientation of the magnetic helices, indicating spontaneous symmetry breaking and the emergence of additional degrees of freedom. Our results provide a framework for characterizing exotic phases that can be extended to a broad class of physical systems.

36 MATERIALS SCIENCE↗