Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗

The Impact of Crosstalk in the X-IFU Instrument on Athena Science Cases

In this paper we present a first assessment of the impact of various forms of instrumental crosstalk on the science performance of the X-ray Integral Field Unit (X-IFU) on the Athena X-ray mission. This assessment is made using the SIXTE end-to-end simulator in the context of one of the more technically challenging science cases for the XIFU instrument. Crosstalk considerations may influence or drive various aspects of the design of the array of high-count-rate Transition Edge Sensor (TES) detectors and its Frequency Domain Multiplexed (FDM) readout architecture. The Athena X-ray mission was selected as the second L-class mission in ESA's Cosmic Vision 2015–25 plan, with alaunch foreseen in 2028, to address the theme ''Hot and Energetic Universe"1. One of the two instruments on boardAthena is the X-ray Integral Field Unit2 (X-IFU) which is based on an array of ~3800 Transition Edge Sensors (TES's)operated at a temperature of ~90 mK. The science cases pose an interesting challenge for this instrument, as they requirea combination of high energy resolution (2.5 eV FWHM or better), high spatial resolution (5 arcsec or better) and highcount rate capability (several tens of counts per second per detector for point sources as bright as 10 mCrab).The performance at the single sensor level has been demonstrated3, but the operation of such detectors in an array, usingmultiplexed readout, brings additional challenges, both for the design of the array in which the sensors are placed and forthe readout of the sensors. The readout of the detector array will be based on Frequency Domain Multiplexing (FDM)4.In this system of detectors and readout, crosstalk can arise through various mechanisms: on the TES array, neighboringsensors can couple through thermal crosstalk. Detectors adjacent in carrier frequency may suffer from electrical crosstalkdue to the finite width of the bandpass filters, and shared sources of impedance in their signal lines. The signals from theindividual detectors are summed and then amplified by a pair of SQUID amplifiers before being sent to warm front-endelectronics. The transfer function of the SQUID amplifiers is non-linear, which will give rise to higher harmonics ofcarriers and intermodulation products when multiple signal pulses are simultaneously present in the SQUID. Under highcount rate conditions this is another source of crosstalk. The effect of all these crosstalk sources is that parasitic pulseswill appear in the record of a signal pulse which will create a stochastic offset of the measured energy and thus adegradation of the energy resolution.

SIXTE↗

Portable MRI developed at Los Alamos

Scientists at Los Alamos National Laboratory are developing an ultra-low-field Magnetic Resonance Imaging (MRI) system that could be low-power and lightweight enough for forward deployment on the battlefield and to field hospitals in the World's poorest regions. "MRI technology is a powerful medical diagnostic tool," said Michelle Espy, the Battlefield MRI (bMRI) project leader, "ideally suited for imaging soft-tissue injury, particularly to the brain." But hospital-based MRI devices are big and expensive, and require considerable infrastructure, such as large quantities of cryogens like liquid nitrogen and helium, and they typically use a large amount of energy. "Standard MRI machines just can't go everywhere," said Espy. "Soldiers wounded in battle usually have to be flown to a large hospital and people in emerging nations just don't have access to MRI at all. We've been in contact with doctors who routinely work in the Third World and report that MRI would be extremely valuable in treating pediatric encephalopathy, and other serious diseases in children." So the Los Alamos team started thinking about a way to make an MRI device that could be relatively easy to transport, set up, and use in an unconventional setting. Conventional MRI machines use very large magnetic fields that align the protons in water molecules to then create magnetic resonance signals, which are detected by the machine and turned into images. The large magnetic fields create exceptionally detailed images, but they are difficult and expensive to make. Espy and her team wanted to see if images of sufficient quality could be made with ultra-low-magnetic fields, similar in strength to the Earth's magnetic field. To achieve images at such low fields they use exquisitely sensitive detectors called Superconducting Quantum Interference Devices, or SQUIDs. SQUIDs are among the most sensitive magnetic field detectors available, so interference with the signal is the primary stumbling block. "SQUIDs are so sensitive they'll respond to a truck driving by outside or a radio signal 50 miles away," said Al Urbaitis, a bMRI engineer. The team's first generation bMRI had to be built in a large metal housing in order to shield it from interference. Now the Los Alamos team is working in the open environment without the large metal housing using a lightweight series of wire coils that surround the bMRI system to compensate the Earth’s magnetic field. In the future, the field compensation system will also function similar to noise-cancelling headphones to eradicate invading magnetic field signals on-the-fly.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Greatly improved cache update times for conditions data with Frontier/Squid

The CMS detector project loads copies of conditions data to over 100,000 computer cores worldwide by using a software subsystem called Frontier. This subsystem translates database queries into HTTP, looks up the results in a central database at CERN, and caches the results in an industry-standard HTTP proxy/caching server called Squid. One of the most challenging aspects of any cache system is coherency, that is, ensuring that changes made to the underlying data get propagated out to all clients in a timely manner. Recently, the Frontier system was enhanced to drastically reduce the time for changes to be propagated everywhere without heavily loading servers. The propagation time is now as low as 15 minutes for some kinds of data and no more than 60 minutes for the rest of the data. This was accomplished by taking advantage of an HTTP and Squid feature called If-Modified-Since. In order to use this feature, the Frontier server sends a Last-Modified timestamp, but since modification times are not normally tracked by Oracle databases, a PL/SQL program was developed to track the modification times of database tables. We discuss the details of this caching scheme and the obstacles overcome including database and Squid bugs.

99 GENERAL AND MISCELLANEOUS↗

Atomic layer deposition of amorphous niobium carbide-based thin film superconductors.

Niobium carbide thin films were synthesized by atomic layer deposition (ALD) using trimethylaluminum (TMA), NbF{sub 5}, and NbCl{sub 5} precursors. In situ quartz crystal microbalance (QCM) measurements performed at 200 and 290 C revealed controlled, linear deposition with a high growth rate of 5.7 and 4.5 {angstrom}/cycle, respectively. The chemical composition, growth rate, structure, and electronic properties of the films were studied over the deposition temperature range 125-350 C. Varying amounts of impurities, including amorphous carbon (a-C), AlF{sub 3}, NbF{sub x}, and NbCl{sub x}, were found in all samples. A strong growth temperature dependence of film composition, growth rate, and room temperature DC resistivity was observed. Increasing film density, decreasing total impurity concentration, and decreasing resistivity were observed as a function of increasing deposition temperature for films grown with either NbF{sub 5} or NbCl{sub 5}. Superconducting quantum interference device (SQUID) magnetometry measurements down to 1.2 K revealed a superconducting transition at T{sub c} = 1.8 K in a 75 nm thick film grown at 350 C with TMA and NbF{sub 5}. The superconducting critical temperature could be increased up to 3.8 K with additional use of NH{sub 3} during ALD film growth.

42 ENGINEERING↗

Development of Magnetic Microcalorimeters for Gamma-Ray Spectroscopy

We present that integrating the SQUIDs and sensing coils of magnetic microcalorimeters onto the same die is a promising approach for maximizing flux coupling and signal/noise. However, new challenges in microfabrication must be overcome, because the underlying SQUID devices are sensitive to chemical attack and elevated processing temperatures. In this paper, we describe development and details of a microfabrication process for integrated SQUID/sensor gamma-ray magnetic microcalorimeters with electroformed gold absorbers, starting from a modified version of the STAR Cryoelectronics “Delta 1000” Josephson Junction process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, cosmic microwave background, mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to transition-edge sensors or microwave kinetic inductance detectors. In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator’s excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at ~ 6 MHz with center frequencies ~ 5–6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.

47 OTHER INSTRUMENTATION↗

Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy

Metallic magnetic microcalorimeters (MMCs) achieve energy resolution comparable to transition-edge sensors (TESs) but rely on different measurement physics that may allow MMCs to surpass TESs in some future applications. We have recently completed fabrication of new MMC γ-ray detector arrays using several exploratory sensor designs. All designs integrate the SQUID and sensor on the same chip and use a superconducting cap layer on the paramagnet, but explore different combinations of combined/separate sensing and magnetization coils and direct/flux transformer coupling to the input SQUIDs. This report describes the design and initial testing of one of these devices, which has so far demonstrated an energy resolution of 38 eV at 60 keV near 10 mK using natural-abundance silver–erbium paramagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication and Magnetic Characterization of CFO/NiO and CFO/NiS Heterostructures

Magnetic analysis of different magnetic bilayers and multilayers is an important step for designing next-generation multiferroic heterostructures. In this study, we have investigated the magnetic interaction at the interface in CFO/NiO hetero-structures grown by pulsed laser deposition on sapphire substrates. The thin film heterostructure samples were characterized by means of X-ray diffraction, scanning electron microscopy (SEM), energy disruptive X-ray spectroscopy (EDS), and superconducting quantum interference device (SQUID) for magnetic measurements. The XRD analysis on different samples shows the crystalline growth of the thin films. The SEM-EDS analysis provides information about structural and elemental compositions of the heterostructure films. A SQUID magnetometer was used to investigate the temperature and field-dependent magnetic properties. To better understand the magnetic properties of the thin film heterostructure samples, zero field cool (ZFC) and field cool (FC) magnetization data were analyzed. At low temperature, ferromagnetic hysteresis loop was observed. A shift in the M-H hysteresis curve was observed for the FC data from the ZFC data, which indicates the presence of exchange bias effect. In addition, we have examined the effect of antiferromagnetic NiS thin films on ferromagnetism of CFO. This study on the magnetic interaction between a ferromagnetic layer and an antiferromagnetic layer can advance the frontier for applications in spin valves, magnetic sensors, and magnetic random access memory.

36 MATERIALS SCIENCE↗

High temperature structural and magnetic properties of cobalt nanorods

We present in this paper the structural and magnetic properties of high aspect ratio Co nanoparticles ({approx}10) at high temperatures (up to 623 K) using in-situ X ray diffraction (XRD) and SQUID characterizations. We show that the anisotropic shapes, the structural and texture properties are preserved up to 500 K. The coercivity can be modelled by {mu}{sub 0}H{sub C}=2(K{sub MC}+K{sub shape})/M{sub S} with K{sub MC} the magnetocrystalline anisotropy constant, K{sub shape} the shape anisotropy constant and M{sub S} the saturation magnetization. H{sub C} decreases linearly when the temperature is increased due to the loss of the Co magnetocrystalline anisotropy contribution. At 500 K, 50% of the room temperature coercivity is preserved corresponding to the shape anisotropy contribution only. We show that the coercivity drop is reversible in the range 300-500 K in good agreement with the absence of particle alteration. Above 525 K, the magnetic properties are irreversibly altered either by sintering or by oxidation. - Graphical abstract: We present in this paper the structural and magnetic properties of high aspect ratio Co nanorods ({approx}10) at high temperatures (up to 623 K) using in-situ X-ray diffraction and SQUID characterizations. We show that the anisotropic shapes, the structural and texture properties are preserved up to 500 K. Above 525 K, the magnetic properties are irreversibly altered either by sintering or by oxidation. Highlights: Black-Right-Pointing-Pointer Ferromagnetic Co nanorods are prepared using the polyol process. Black-Right-Pointing-Pointer The structural and texture properties of the Co nanorods are preserved up to 500 K. Black-Right-Pointing-Pointer The magnetic properties of the Co nanorods are irreversibly altered above 525 K.

36 MATERIALS SCIENCE↗

A terraced scanning superconducting quantum interference device susceptometer with submicron pickup loops

Superconducting quantum interference devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pickup loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with terraced tips that position the pickup loops 300 nm from the sample. The 600 nm-2 {mu}m pickup loops, defined by focused ion beam, are integrated into a 12-layer optical lithography process allowing flux-locked feedback, in situ background subtraction and optimized flux noise. These features enable a sensitivity of {approx}70 electron spins per root hertz at 4 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting quantum interference devices based set-up for probing current noise and correlations in three-terminal devices

We have implemented a new experimental set-up for precise measurements of current fluctuations in three-terminal devices. The system operates at very low temperatures (30 mK) and is equipped with three superconducting quantum interference devices (SQUIDs) as low noise current amplifiers. A SQUID input coil is connected to each terminal of a sample allowing the acquisition of time-dependent current everywhere in the circuit. From these traces, we can measure the current mean value, the noise, and cross-correlations between different branches of a device. In this paper, we present calibration results of noise and cross-correlations obtained using low impedance macroscopic resistors. From these results, we can extract the noise level of the set-up and show that there are no intrinsic correlations due to the measurement scheme. We also studied noise and correlations as a function of a dc current and estimated the electronic temperature of various macroscopic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proximity effect bilayer nano superconducting quantum interference devices for millikelvin magnetometry

Superconducting quantum interference devices (SQUIDs) incorporating thin film nanobridges as weak links have sensitivities approaching that required for single spin detection at 4.2 K. However, due to thermal hysteresis they are difficult to operate at much lower temperatures which hinder their application to many quantum measurements. To overcome this, we have developed nanoscale SQUIDs made from titanium-gold proximity bilayers. We show that their electrical properties are consistent with a theoretical model developed for heat flow in bilayers and demonstrate that they enable magnetic measurements to be made on a sample at system temperatures down to 60 mK.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A study of spin canting in Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} with Mössbauer spectroscopy under 5 T

Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} has been actively studied as a Lithium ion battery cathode material for the next-generation energy storage application. Here, we have investigated the changes of magnetic coupling between two different magnetic sub-lattices in Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} with x-ray diffraction (XRD), superconducting quantum interference device (SQUID), and Mössbauer spectroscopy measurements. The experimental XRD pattern was analyzed using Rietveld refinement, confirming single phase. In order to investigate the magnetic property, the SQUID measurement under applied field of 5 T was performed between 4.2 and 295 K. From the temperature-dependent zero-field-cooled and field-cooled magnetization curves, we observed the magnetization decreasing with increasing temperature up to T{sub min} = 13 K, at which the magnetization showed a minimum value. With continuing increase in temperature, the magnetization starts increasing with a maximum value at T{sub max} = 28 K and beyond T{sub max}, the magnetization decreases with the further increase in temperature. Based on the experimentally measured Mössbauer spectra, we identified that the ratios of first and sixth to second and fifth absorption lines were identical around T{sub min}, while with increasing temperature the area of second and fifth absorption line rapidly decreased up to T{sub max}. Our study suggests that the spin canting angle between the applied field and hyperfine field of Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} is constant up to T{sub min}. However, the spin canting angle starts decreasing with increasing temperature, reaching a minimum value at T{sub max}, and beyond T{sub max} it is increasing. We expect that around T{sub max}, the ferrimagnetically coupled spin arrangement is appeared to be collinear along the applied field direction under applied field of 5 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro-coil detection of nuclear magnetic resonance for nanofluidic samples

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair. A high degree of coupling between the coil and the region of interest of similar dimensions (up to ∼ 100 microns) can be achieved. We report nuclear magnetic resonance (NMR) measurements to characterise the sensitivity of these coils to {sup 3}He in the gas phase at 4.2 K in a 30 mT magnetic field.

36 MATERIALS SCIENCE↗

Superconducting inductive displacement detection of a microcantilever

We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗