Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Thermal-Hydraulic Performance of the TREAT Multi-SERTTA for Reactivity Initiated Accident Experiments

Experimental testing in the Multi-Static Environment Rodlet Transient Test Apparatus (SERTTA) will lead the rebirth of transient fuel testing in the United States as part of the Accident Tolerant Fuels (ATF) progam. The Multi-SERTTA is comprised of four isolated pressurized environments capable of a wide variety of working fluids and thermal conditions. Ultimately, the TREAT reactor as well as the Multi-SERTTA test vehicle serve the purpose of providing desired thermal-hydraulic boundary conditions to the test specimen. The initial ATF testing in TREAT will focus on reactivity insertion accident (RIA) events using both gas and water environments including typical PWR operating pressures and temperatures. For the water test environment, a test configuration is envisioned using the expansion tank as part of the gas-filled expansion volume seen by the test to provide additional pressure relief. The heat transfer conditions during the high energy power pulses of RIA events remains a subject of large uncertainty and great importance for fuel performance predictions. To support transient experiments, the Multi-SERTTA vehicle has been modeled using RELAP5 with a baseline test specimen composed of UO2 fuel in zircaloy cladding. The modeling results show the influence of the designs of the specimen, vehicle, and transient power pulses. The primary purpose of this work is to provide input and boundary conditions to fuel performance code BISON. Therefore, studies of parameters having influence on specimen performance during RIA transients are presented including cladding oxidation, power pulse magnitude and width, cladding-to-coolant heat fluxes, fuel-to-cladding gap, transient boiling effects (modified CHF values), etc. The results show the great flexibility and capacity of the TREAT Multi-SERTTA test vehicle to provide testing under a wide range of prototypic thermal-hydraulic conditions as never done before.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal-hydraulic performance of the TREAT Multi-SERTTA for reactivity initiated accident experiments

Experimental testing in the Multi-Static Environment Rodlet Transient Test Apparatus (SERTTA) will lead the rebirth of transient fuel testing in the United States as part of the Accident Tolerant Fuels (ATF) program. The Multi-SERTTA is comprised of 4 isolated pressurized environments capable of a wide variety of working fluids and thermal conditions. Ultimately, the TREAT reactor as well as the Multi-SERTTA test vehicle serve the purpose of providing desired thermal-hydraulic boundary conditions to the test specimen. The initial ATF testing in TREAT will focus on reactivity insertion accident (RIA) events using both gas and water environments including typical PWR operating pressures and temperatures. The heat transfer conditions during the high energy power pulses of RIA events remains a subject of large uncertainty and great importance for fuel performance predictions. To support transient experiments, the Multi-SERTTA vehicle has been modeled using RELAP5 with a baseline test specimen composed of fresh UO{sub 2} fuel in zircaloy cladding. The results show that for energy depositions less than 1380 J/g-UO{sub 2}, the vessel environment remains sub-supercritical. Two extremes of gap conductance show significant effect on event timing and peak cladding temperature but little effect on end state conditions. Inclusion of oxidation has increasing impact for increasing energy depositions. The effect of oxidation is non-negligible for planned TREAT experiments in the range of explored energy depositions. Pulse width has little impact on thermal hydraulic conditions under the assumptions used in this analysis. The model used in this work has been coupled to the fuel performance code, BISON, to accomplish best estimate predictive capability for Multi-SERTTA experiments. The results show the great flexibility and capacity of the TREAT Multi-SERTTA test vehicle to provide testing under a wide range of prototypic thermal-hydraulic conditions as never done before.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of material models for puncture of 7075-T651 aluminum plate

Plate puncture simulations are challenging computational tasks that require advanced material models including high strain rate and thermal-mechanical effects on both deformation and failure, plus finite element techniques capable of representing large deformations and material failure. The focus of this work is on the material issues, which require large sets of experiments, flexible material models and challenging calibration procedures. In this study, we consider the puncture of 12.7 mm thick, 7075-T651 aluminum alloy plates by a cylindrical punch with a hemispherical nose and diameter of 12.7 mm. The plasticity and ductile failure models were isotropic with calibration data obtained from uniaxial tension tests at different temperatures and strain rates plus quasi-static notched tension tests and shear-dominated tests described here. Sixteen puncture experiments were conducted to identify the threshold penetration energy, mode of puncture and punch acceleration during impact, The punch was mounted on a 139 kg mass and dropped on the plates with different impact speeds. Since the mass was the same in all tests, the quantity of interest was the impact speed. The axis and velocity of the punch were perpendicular to the plate surface. The mean threshold punch speed was 3.05 m/s, and the mode of failure was plugging by thermal-mechanical shear banding accompanied by scabbing fragments. Application of the material models in simulations of the tests yielded accurate estimates of the threshold puncture speed and of the mode of failure. Time histories of the punch acceleration compared well between simulation and test. Remarkably, the success of the simulations occurred in spite of even the smallest element used being larger than the width of the shear bands.

36 MATERIALS SCIENCE↗

Study on Fracture of Fiber-Reinforced Polymeric Composites Using Spiral Notch Torsion Test

Fiber-reinforced polymer-matrix composites have been widely applied in various areas due to their excellent mechanical properties. In this study, carbon fiber-reinforced polymer-matrix composites and glass fiber-reinforced polymer-matrix composites failure tests under quasi static torsion have been demonstrated by using spiral notch torsion test methodology. Three types of cylindrical specimens with different fiber orientations were prepared and tested. For both composites, after increase stage, A type exhibited limited stress variations before the sudden failure, whereas B type showed gradual failure with torque drops. Displacement contours, stress contours and energy release rates were acquired using the anisotropic elastic finite element models. Microscopic characterization exhibited that the failure of A type occurred along interfaces between fibers and matrices, whereas circular cracks in B type propagated alternatively between polymeric matrices and interfaces. Type C failure is similar to type A whereas with a curvature observed on the fracture surface.

Du, Fen↗

Blade Testing Equipment Development and Commercialization: Cooperative Research and Development (Final Report)

Blade testing is required to meet wind turbine design standards, reduce machine cost, and reduce the technical and financial risk of deploying mass-produced wind turbine models. NREL's National Wind Technology Center (NWTC) in Colorado is the only blade test facility in the U.S. capable of performing full-scale static and fatigue testing of multi-megawatt-scale wind turbine blades. Rapid growth in wind turbine size over the past two decades has outstripped the size capacity of the NWTC blade test facility leaving the U.S. wind industry without a suitable means of testing blades for large land-based and offshore turbines. This CRADA will develop and commercialize testing technologies and test equipment, including scaling up, value engineering, and testing of equipment to be used at blade testing facilities in the U.S. and around the world.

17 WIND ENERGY↗

Status Report on Development of TREAT Water Loop

The Transient Reactor Test (TREAT) facility is a graphite based transient test reactor at the Idaho National Laboratory (INL). TREAT started operation in 1959 and performed thousands of transient irradiations for the primary purpose of nuclear fuel safety research. TREAT operations were suspended in 1994, and then, several years later, resumed reactor operations in 2017 to support development of advanced nuclear fuels. TREAT’s more recent historic focus had been for transients with relevance to sodium cooled fast spectrum reactors. TREAT’s first year of modern experiment work performed in 2018, however, saw the demonstration of new kinds of transients focused on light water reactor (LWR) needs including reactivity initiated accidents (RIA) and loss of coolant accidents (LOCA). The successful outcome of these efforts confirmed TREAT’s viability as a transient neutron source for LWR safety research. Since TREAT’s core is air cooled and provides no “built-in” thermal hydraulic boundary conditions for tests specimens, efforts have been underway to establish water-environment capabilities for testing specimens. Small static water capsules have been established to support single rod RIA testing where transient heating is brief. Similarly, deployment of enhanced water capsules with blowdown capability is nearing completion to support single rod LOCA testing. With careful experiment design these capsules can provide representative temperature response histories and water phase transitions for some experiment parameters. The capsule approach is appropriate for cost-effective early phase phenomena identification studies on novel fuels, or when the important test variables are thought to be fairly well understood so that they can be precisely targeted (such as they are for current fleet fuels with moderate burnup UO2 in uncoated zirconium alloy cladding). Due to lack of forced convection, however, the capsule approach cannot achieve representative temperature histories in all regions of the test fuel simultaneously (e.g. cladding and fuel centerline temperatures) while providing representative timing in water phase transitions. Nor can the capsule approach provide appropriate hydraulic conditions for multi-rod bundle testing. For these reasons, design and development has been undertaken for the TREAT Water-Environment Recirculating Loop (TWERL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Failure Strain and Related Triaxiality of Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 Metals, Part I: Experimental Investigation

The objective of this study is to develop failure-limit material models for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals, based on parameters of plastic equivalent strain (failure strain) and stress triaxiality. The research is conducted in two parts. This paper presents Part One of the study. In Part One, custom-designed test specimens undergo controlled uniaxial tension and compression testing at ambient temperature. These tests are performed at quasi-static speeds using Universal Testing Machines (UTMs) in accordance with ASTM E8 and ASTM E9 standards. Experimental data, specifically engineering stress–strain and force–displacement curves, are recorded from the onset of loading until specimen fracture, or in the case of compression tests, until the capacity of the testing machine is reached. In Part Two, the emphasis shifts to the calibration of Finite Element Analysis (FEA) models of the custom-designed test specimens. Plastic equivalent strain and the corresponding stress triaxiality values at failure are extracted from each test specimen for the given metal. These values are then systematically plotted onto a single graph to construct the failure-limit curve, which delineates the boundary conditions for material failure. This approach will facilitate the development of a comprehensive material property definition that correlates plastic equivalent strain with stress triaxiality at failure for Aluminum 6061-T6, A36 Carbon Steel, 304 Stainless Steel, and Nitronic 60 metals.

Harwell, Ron↗

Enabling the Electrification of Offshore Activities – Co-Demonstration of Next-Generation Autonomous Offshore Power System and Resident, Uncrewed Mobile and Static Assets at PacWave Wave Energy Test Site

Oceans cover two-thirds of the earth's surface and form the world's biggest and best – yet largely untapped – battery. Ocean waves have more energy density than other renewables, including wind, solar, and biomass, and have the potential to supply 4x the world's annual energy consumption (Masterson, 2022; Zic, 2020). In addition to the impact wave energy can have on decarbonizing and diversifying the electric grid, it offers a significant value proposition in the emerging blue economy sector (LiVecchi et al, 2019). The blue economy consists of industries operating offshore, including shipping, oil and gas, defense and security, aquaculture, and research. These industries require bringing people and energy on site to perform daily work, but current energy costs in the blue economy are extremely high. Here, the prevailing processes are complex, including shore dependencies and fuel transportation logistics. Few alternatives for reliable power generation exist, with the most prominent being high cost and high carbon emissions diesel generation. Because of this lack of affordable, reliable power, the trends of electrification, digitization, and automation that have led to substantial innovation and improvements in the terrestrial economy over the last two decades are slow to come to the blue economy.

16 TIDAL AND WAVE POWER↗

Thermal-hydraulic and Fuel Performance Scoping Studies of a Flowing Water Capsule in TREAT

The restart of the Transient Reactor Test (TREAT) facility has provided a much needed capability for integral transient testing of nuclear fuel. This testing is necessary to qualify new fuel concepts such as those developed under the Accident Tolerant Fuel (ATF) program, increasing the burnup limit of light water reactor (LWR) fuels, or a variety of other programs under the Advanced Fuels Campaign (AFC). The ATF campaign has been the main driver behind the development and implementation of a variety of capsules for TREAT experiments. The Separate-Effect Test Holder (SETH) was a dry capsule that enabled testing of ATF concepts under reactivity-initiated accident (RIA) heating conditions. Following SETH, the Static Environment Rodlet Transient Test Apparatus (SERTTA) was developed to enable RIA testing in a static water environment. In efforts to support the need for future Loss-of-Coolant Accident (LOCA) tests, the Transient Water Irradiation System for TREAT (TWIST) capsule has been developed that allows for water to drain from around the fuel rod and lower the pressure to simulate LOCA conditions. All these capsules that have been developed for LWR fuel testing all lack the capability for forced convective cooling which in some applications may limit their ability to test under prototypic conditions. A design and modeling effort has been started to modify the TWIST capsule by adding a flow tube and impeller that can create flowing coolant conditions for the fuel rod. RELAP5-3D and BISON models are being used to study the differences between RIA, LOCA, Anticipated Operational Occurrences (AOO), LWR power cycling, and other transient scenarios under flowing conditions capable in the flowing capsule and the current stagnant water capsules (SERTTA and TWIST). The scoping study will provide guidance on the needed capabilities for the flowing capsule and the limitations of the currently developed capsule for LWR testing in TREAT.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Strain Rate on the Plastic Deformation and Fracture of 90W-7Ni-3Fe Alloy Prepared by Liquid-Phase Sintering

In this study, the effect of the strain rates on the plastic deformation behavior and fracture mechanism of 90W-7Ni-3Fe heavy alloy prepared by liquid-phase sintering was investigated. Stress–strain tests were carried out in tensile and compression under quasi-static condition with the strain rate ranging from 10{sup −3} to 1 s{sup −1}. Dynamic test was examined using a compression split Hopkinson bar at strain rates ranging from 1000 to 1700 s{sup −1} in order to evaluate the effects of high strain rate on dynamic plastic deformation behavior. Quasi-static tests results show that the strength and hardness of this alloy increase with increasing strain rate. Results indicate that the as-sintered 90W-7Ni-3Fe heavy alloy has obvious strain-hardening characteristic under tensile or compression deformation under quasi-static condition. At this time, strain hardening is the main factor. Nevertheless, strain-hardening and strain-softening behaviors of the specimens occur simultaneously under dynamic compression condition. The effect of compressive stress on the work hardening is more obvious. A strong relevance of work-hardening effect on strain rate is also found. And the fracture mode of quasi-static and dynamic compression samples is also different.

36 MATERIALS SCIENCE↗

Computational and Experimental Simulation of Static Memory Cells of Submicron Microcircuits under the Effect of Neutron Fluxes

The simulation of reversible single events in test samples of static memory microcircuits with design norms of 0.5, 0.35, 0.25, and 0.1 μm under the effect of neutron fluxes with various energies is performed. It is shown theoretically and experimentally that reversible single events can occur in modern microelectronics and nanoelectronics products under the effect of a fission-spectrum neutron flux caused by the passage of primary recoil atoms and nuclear reaction products along the microcircuit surface perpendicularly to the electric current lines in the near-drain transistor area. A series of irradiation experiments of static memory circuits with design norms of 0.35 μm is interpreted based on the proposed model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RIA Testing in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s. The reactors flexible design and multi-mission nature provided thousands of transient irradiations for numerous reactor fuels and transient types before being placed in standby in 1994. The reactor resumed operations in 2017 to reclaim its crucial role in nuclear-heated safety research. A principal goal of restarting the reactor was to perform transient testing of Accident Tolerant Fuels (ATF), supporting their safe adoption by the commercial Light Water Reactor (LWR) fleet. In support of the Accident Tolerant Fuels mission, multiple capsules have been designed and are currently being designed to test fuel specimens under varying conditions. The Minimal Activation Retrievable Capsule Holder (MARCH) system was designed to support high throughput testing by using a modular approach where an outer containment structure will act as the primary safety containment. The MARCH system is designed to house various modules for testing different fuel systems in different environments. The near-term tests for the ATF concepts will use the Static Environment Rodlet Transient Test Apparatus (SERTTA), aka MARCH-SERTTA. MARCH-SERTTA is capable of testing a single ATF rodlet 10 cm in length in a static pool of water with initial conditions up to 200°C and 500 psi. The purpose of the MARCH-SERTTA device is to perform integral tests evaluating the Pellet Clad Mechanical Interaction (PCMI) performance of LWR fuel concepts in design basis Reactivity Initiated Accidents (RIA). This will be accomplished by testing a variety of ATF fuel concepts under varying initial thermal-hydraulic conditions and varying prompt energy pulses. The flexibility of TREAT and the MARCH-SERTTA capsule enables testing of a unique, non-fueled, rod specimen under similar conditions as the fueled specimens to perform separate-effect tests. This non-fueled rod will be used to study the thermal-hydraulic behavior (specifically determine the critical heat flux) during these fast prompt transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Influence of water flow on heterotrophic respiration of natural soils

New evidence highlights the importance of hydrology to microbial decomposition of organic matter in soils. The objective of this study was to build a reproducible and controlled capability for measuring soil respiration in the laboratory and to test the hypothesis: Soil respiration rate in a flowing system will stay higher compared to in static water. We tested replicates for flowing versus non-flowing soil water for two different soils. The water content was maintained at a consistent saturation in the flowing system but significantly desaturated in the no-flow soils over the course of a 10-day and 28-day experiment. The measured respiration had a significantly higher rate of change in the first day for one soil but after the first day and for the entire reaction for the second soil there was no measurable difference in respiration.

58 GEOSCIENCES↗

Moisture Effects on Compaction of Fiberboard in a 9975 Shipping Package (Final Report)

Compaction of lower layers in the fiberboard assembly has been observed in 9975 packages that contain elevated moisture. Lab testing has resulted in a better understanding of the relationship between the fiberboard moisture level and compaction of the lower fiberboard assembly, and the behavior of the fiberboard during transport. In laboratory tests of cane fiberboard, higher moisture content has been shown to correspond to higher total compaction, greater rate of compaction, and continued compaction over a longer period of time. In addition, laboratory tests have shown that the application of a dynamic load results in higher fiberboard compaction compared to a static load. The test conditions and sample geometric/loading configurations were chosen to simulate the regulatory requirements for 9975 package input dynamic loading. Dynamic testing was conducted to acquire immediate and cumulative changes in geometric data for various moisture levels. Two sample sets have undergone a complete dynamic test regimen, one set for 27 weeks, and the second set for 47 weeks. The dynamic input, data acquisition, test effects on sample dynamic parameters, and results from this test program are summarized and compared to regulatory specifications for dynamic loading. Compaction of the bottom fiberboard layers due to the accumulation of moisture is one possible cause of an increase in the axial gap at the top of the package. The net compaction of the bottom layers will directly add to the axial gap. The moisture which caused this compaction migrated from the middle region of the fiberboard assembly (which is typically the hottest). This will cause the middle region to shrink axially, which will also contribute directly to the axial gap. Measurement of the axial gap provides a screening tool for identifying significant change in the fiberboard condition. The data in this report provide a basis to evaluate the impact of moisture and fiberboard compaction on 9975 package performance during storage at the Savannah River Site (SRS).

36 MATERIALS SCIENCE↗