Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Modulation of Gulf Stream Influence on the Troposphere by the Eddy-Driven Jet

This study suggests that the Gulf Stream influence on the wintertime North Atlantic troposphere is most pronounced when the eddy-driven jet (EDJ) is farthest south and better collocated with the Gulf Stream. Using the reanalysis dataset NCEP-CFSR for December–February 1979–2009, the daily EDJ latitude is separated into three regimes (northern, central, and southern). It is found that the average trajectory of atmospheric fronts covaries with EDJ latitude. In the southern EDJ regime (~19% of the time), the frequency of near-surface atmospheric fronts that pass across the Gulf Stream is maximized. Analysis suggests that this leads to significant strengthening in near-surface atmospheric frontal convergence resulting from strong air–sea sensible heat flux gradients (due to strong temperature gradients in the atmosphere and ocean). In recent studies, it was shown that the pronounced band of time-mean near-surface wind convergence across the Gulf Stream is set by atmospheric fronts. Here, it is shown that an even smaller subset of atmospheric fronts—those associated with a southern EDJ—primarily sets the time mean, due to enhanced Gulf Stream air–sea interaction. Furthermore, statistically significant anomalies in vertical velocity extending well above the boundary layer are identified in association with changes in EDJ latitude. These anomalies are particularly strong for a southern EDJ and are spatially consistent with increases in near-surface atmospheric frontal convergence over the Gulf Stream. These results imply that much of the Gulf Stream influence on the time-mean atmosphere is modulated on synoptic time scales, and enhanced when the EDJ is farthest south.

54 ENVIRONMENTAL SCIENCES↗

Decontamination of Mixed Paper and Plastic Municipal Solid Waste Increases Low and High Temperature Conversion Yields

With the implementation of China’s Green Fence Policy and the following National Sword Policy, there is a need to divert previously accepted waste materials away from the landfill. Mixed plastic and paper wastes that are too contaminated to be economically recycled can be used for conversion into fuels and products. The effect of common contaminants present in waste streams must be determined to make municipal solid waste (MSW) a viable alternative to agricultural feedstocks for conversion. In this study, MSW was sourced from a dual stream materials recovery facility (MRF) in Emmet County, Michigan and characterized via mass balance. The most common contaminants in mixed paper and plastic were quantified and targeted for decontamination when mixed paper was explored for low temperature conversion pathways and plastics for high temperature conversion pathways. Ink, stickies, and plastic contamination were sorted out of the mixed paper stream and did not have an impact on sugar yields during enzymatic hydrolysis (EH). Although no improvement in yield was found, it was noted that copy paper within the mixed paper stream had an elevated pH and higher concentration of fermentation inhibitors, suggesting that intrinsic properties of some paper types may not be ideal for EH and fermentation conversion. Dilute alkaline pretreatment and mechanical refining of mixed paper increased the EH yield of mixed paper, suggesting this previously established process could be used as a decontamination method. “Dirt” and particulates were washed from mixed plastic using either an aqueous detergent or a non-aqueous chemical washing method. Liquid oil yields were increased during microwave assisted fast pyrolysis. All decontamination techniques met the cost target of less than $30/dry ton with plastic decontamination ranging from $18.16 to $24.81/dry ton. Because dilute alkaline pre-treatment and mechanical refining is considered part of the conversion process, the decontamination cost during feedstock preprocessing was considered $0/dry ton.

09 BIOMASS FUELS↗

Tar Formation and Mitigation in Pressurized Biomass and Cofired Gasification

Biomass gasification with CO2 capture has the potential to provide carbon-negative heat, power, and feedstock for sustainable hydrocarbon fuels. In a pressurized gasifier, precombustion solvent systems can capture CO2 with less energy than needed for amine-based postcombustion CO2 capture, and pressurized syngas is generally more suitable for fuel synthesis. Although precombustion capture has been used for many decades in large-scale fossil-based plants, it has not been well-demonstrated in smaller-scale biomass gasification. Precombustion solvents and product streams could be particularly impacted by tar and other organic compounds that tend to form in high concentrations during low-temperature biomass gasification. A pressurized pilot-scale gasifier was used to examine tar formation and fate when using CO2 capture with various blends of biomass and coal. The syngas was fully conditioned to remove particulate matter; capture sulfur; adjust syngas chemistry using water-gas shift; quench out moisture and condensable organics; and capture CO2. Tar concentrations were measured in the raw syngas, the product gas, and in the liquid streams over the course of several weeks. The gasifier was operated both as a high-pressure oxygen-blown system to mimic large-scale centralized gasification and at lower pressures under air-blown conditions to mimic a more likely small-scale system. A second high-temperature stage with oxidant injection was used to crack tars. The overall results showed how gasifier and CO2 capture performance change as fuel is blended between coal to biomass and what the fate of tar is through a precombustion CO2 capture system.

Strege, Josh [University of North Dakota EERC] (OR↗

IDAES-PSE 2.3.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications.. New Features and Models • New diagnostics toolboxes and examples o Tutorial for using the DiagnosticsToolbox o Methods to identify potential evaluation errors in models o SVDToolbox for performing singular value decomposition analysis on models to identify possible degeneracies and poor scaling o DegeneracyHunter for identifying irreducible degenerate sets in models • Model for solid-liquid separation which takes two inputs (solid and liquid streams) and produces three outlets (solids, liquid entrained with solids and pure liquid) • Example of temperature swing adsorption in models_extra Deprecation Warnings • With the update to Pyomo 6.7.0, the plate heat exchanger model has begun failing tests on some CI platforms. If this is not addressed by the February release, this model may be removed due to failing tests. See #1294. Offers to help identify the cause and fix this issue are welcome. Improvements and bug fixes • Fixed oversight which precluded using Mixer and Separator models when inherent reactions were present in property package • Added reporting methods to the MSContactor model • Minor corrections in some examples where values were being fixed outside of declared variable bounds

DiagnosticsToolbox,IDAES,PSE,Process Systems Engin↗

Parametric Testing and Evaluation of a Novel Biphasic Absorption Process for Post-Combustion Carbon Capture

A novel biphasic CO2 absorption process (BiCAP) is being developed at the University of Illinois. BiCAP is enabled by using a new class of biphasic solvents developed based on multi-property criteria for postcombustion carbon capture. The process was previously demonstrated at the lab-scale, including in 10 kWe absorption and desorption column systems. In the current study, the process has been scaled up by building and testing a 40 kWe integrated capture skid at a power plant. Parametric tests for two biphasic solvents were conducted with the synthetic flue gas made of bottle CO2 gas and air to validate the performance and operational flexibility of the unit with respect to varying process or operating conditions. Operation of the phase separator, which is unique equipment to BiCAP, was verified to be stable and efficient. Two liquid phases could be separated via static settlement based on a density difference and >90% of the CO2 absorbed was concentrated in the separated CO2-rich phase. Results of parametric tests showed that the minimum heat duty appeared at the optimal stripping pressure. A higher stripping temperature was more favourable to improve overall energy performance. Introducing a secondary cold solvent feed stream to the top of the stripper via bypassing the cross heat exchanger helped reduce the heat loss carried with water vapour. Test results also revealed that the heat duty requirement was comparable when the CO2 concentration in flue gas decreased from ~11 to 4 vol.% as the phase separation decoupled the absorption and desorption steps in BiCAP. Under typical steady-state conditions, both biphasic solvents lowered the process heat duty by >40% compared with the reference 30 wt.% monoethanolamine solvent.

Absorption↗

In-situ resource utilization-derived water purification and hydrogen and oxygen production

This disclosure provides an integrated system and method for producing purified water, hydrogen, and oxygen from contaminated water. The contaminated water may be derived from regolith-based resources on the moon, Mars, near-Earth asteroids, or other destination in outer space. The integrated system and method utilize a cold trap to receive the contaminated water in a vapor phase and selectively freeze out water from one or more volatiles. A heat source increases temperature in the cold trap to vaporize the frozen contaminated water to produce a gas stream of water vapor and volatiles. A chemical scrubber may remove one or more volatiles. The integrated system and method utilize ionomer membrane technology to separate the water vapor from remaining volatiles. The water vapor is delivered for crew use or delivered to an electrolyzer to produce hydrogen and oxygen.

Finger, Barry Wynns↗

The effect on soot and its gas precursors of doping ethylene with 2,2,4,6,6-pentamethyl-heptane in the nitrogen-fuel stream of a laminar non-premixed Planar Mixing Layer Flame (PMLF)

Synthetic Aviation Turbine Fuels (SATFs) are promising for reducing soot emissions from the aviation sector and diversifying Jet Fuel (JF) sources. Accurately predicting the combustion and emissions behavior of SATFs (and other JFs) necessitates robust experimental databases to elucidate the chemistry of long-chain iso-paraffins, which can compose up to two-thirds of SATF blends and whose behavior is considered to be well-represented by that of iso-dodecane isomers. Here, this study characterizes two laminar non-premixed Planar Mixing Layer Flames (PMLFs) with mild soot loads fueled by nitrogen-diluted ethylene, pure and doped with 2,2,4,6,6-pentamethyl-heptane, respectively. The two PMLFs have the same stoichiometric mixture fraction and total hydrocarbon mole fraction in the fuel stream (X F,F =X C2H4,F +X C12H26,F = 0.260), resulting in nearly the same maximum temperature (T max ≈1800 K) and simple identification of the effects of doping. Importantly, any horizontal PMLF cross-section has a self-similar structure that can be modeled as an equivalent One-Dimensional Counterflow Flame (1D-CF) with vanishingly small strain rate (a). The cross-section at a Height Above the Burner (HAB) of 50 mm is characterized in terms of C 0 -C 18 gas species using capillary sampling followed by GC-MS analyses. Laser-Induced Emission Spectroscopy (LIES) quantifies the soot volume fraction (ƒ v ) profiles at HAB=25 and 50 mm where Elastic Laser Light Scattering (E-LLS) is performed to determine the a of the equivalent 1D-CFs and the profile of the E-LLS equivalent diameter ( d 6,3 ) of soot. The substitution of 1500 ppm of ethylene with 2,2,4,6,6-pentamethyl-heptane causes an increase of ≈1.5 in the concentrations of several polycyclic aromatic hydrocarbons and fv. Concurrently, the measured d 6,3 doubles in the oxidizer stream, yet remains the same in the fuel stream, at HAB=50 mm. Instead, at HAB= 25 mm, the iso-dodecane doping does not affect the d 6,3 profile in either stream. The experimental results partially validate the chemical reactions and soot formation kinetic model developed at Lawrence Livermore National Laboratory and provide directions to further improve its predictions.

Iso-dodecane (2,2,4,6,6-Pentamethyl-Heptane)↗

RuKY Catalyst‐Packed Permeation Membrane for Quantitative Ammonia and d3‐Ammonia Dehydrogenation to Ultrapure Hydrogen

Ammonia is a promising carbon-free hydrogen carrier, but incomplete ammonia dehydrogenation (cracking) generates atmospheric emissions of NO x , a potent greenhouse gas. Additionally, incomplete cracking of ammonia leads to regulatory challenges in nuclear and fusion power, where tritiated ammonia (NT 3 ) emissions are strictly controlled. Therefore, we report the use of low-temperature ammonia dehydrogenation catalysts (3%Ru/1%Y/12%K/Al 2 O 3 ) in a palladium alloy H 2 permeation membrane for quantitative conversion of ammonia into hydrogen and nitrogen at industry-relevant conditions. This catalytic membrane reactor system achieved an astonishing effluent concentration of <1 ppm at 450°C under a 100% NH 3 stream, which is far beyond the 99.6% conversion target required for the adoption of ammonia as a vehicle fuel. The low-temperature ammonia dehydrogenation catalyst was tested in a packed bed reactor with NH 3 and ND 3 to both elucidate the reaction mechanism and to quantify the kinetic isotope effect of the membrane reactor. The rate-limiting step at temperatures relevant to the palladium membrane are isotope independent, indicating that the isotopologue content will not modify the desired reaction kinetics. By reducing emissions to below-trace levels with no additional separation, this work provides a path to greatly simplified and miniaturized ammonia cracking processes.

ammonia decomposition↗

The effectiveness of D 2 pellet injection in reducing intra-ELM and inter-ELM tungsten divertor erosion rates in DIII-D during the Metal Rings Campaign

Abstract Edge localized modes (ELMs) in H-mode plasmas erode plasma-facing components (PFCs) and lead to impurities in the core, reducing confinement. This study analyzes D 2 pellet injection on the DIII-D fusion experiment used as an ELM mitigation technique applied during the 2016 tungsten Metal Rings Campaign to reduce W erosion during ELMs. The 400.9 nm photon wavelength line emission intensity of tungsten atoms (WI) filterscope channels and Langmuir probes were used to infer the gross erosion rate of tungsten-coated tiles installed in the divertor of DIII-D. D 2 mass injection rates ranging from 34 to 41 arbitrary units (A.U.) and no D 2 injection resulted in a similar total W erosion rate during ELMs (intra-ELM). On average, results show a 29% increase in the total gross W erosion rate with intermediate mass injection rates (∼13–23 A.U.) compared to the no pellets and the highest injection rate cases. On average, the fast D 2 mass injection rate cases had 15% less erosion in the inter-ELM phase than the case with no pellets. Generally, higher D 2 mass injection rates increased the ELM frequency, and the highest injection rates reduced the average erosion per ELM and fractional carbon impurities at the top of the pedestal by nearly 40% when compared to the no-pellet case. As expected, a higher D 2 pellet injection rate led to a higher plasma density and lower plasma temperature in the divertor. Additionally, an increasing divertor inter-ELM plasma electron density directly correlated to more frequent pellet injection and a decrease in both the average gross intra-ELM W erosion and the total gross intra-ELM W erosion rate. Simulations of intra-ELM erosion using the ‘free-streaming plus recycling model’ (FSRM) underestimate W erosion during pellet injection by about 30% on average. The discrepancies between the experimental measurements and the FSRM intra-ELM W erosion predictions are postulated to be due to C/W material mixing. A simple analytic mixed-material model is presented and results in better agreement with the experimental data. These results highlight the importance of incorporating the effects of a mixed-material layer in the analysis of PFC erosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increasing temperature and flow management alter mercury dynamics in East Fork Poplar Creek

East Fork Poplar Creek (EFPC) is a mercury (Hg) contaminated creek in east Tennessee, USA. Stream restoration activities included the initiation of a flow management programme in 1996 in which water from a nearby lake was pumped to the head of the creek. We conducted regular water sampling for 2 years along the length of EFPC during active flow management and for 5 years after flow management stopped. Total Hg and total monomethylmercury (MMHg) concentration and flux decreased in the uppermost reaches of EFPC that were closest to the point of water addition. Most water quality parameters, including DOC concentration, remained unchanged after flow management termination. Nevertheless, SUVA 254 , a measure of dissolved organic matter (DOM) composition, increased and coincided with increased dissolved Hg (Hg D ) concentration and flux and decreased Hg solid-water partitioning coefficients throughout EFPC. Higher SUVA 254 and Hg D concentration have potential implications for bioavailability and MMHg production. Total and dissolved MMHg concentrations increased in lower reaches of EFPC after the end of flow management and these increases were most pronounced during spring and early summer when biota are more susceptible to exposure and uptake. A general warming trend in the creek after active flow management ended likely acted in concert with higher Hg D concentration to promote higher MMHg concentration. Total and dissolved MMHg concentrations were positively correlated with water temperature above a threshold value of 10°C. Concentration changes for Hg and MMHg could not be accounted for by changes in creek discharge that accompanied the cessation of flow management. In addition to the changing DOM composition in-stream, other watershed-scale factors likely contributed to the observed patterns, as these changes occurred over months rather than instantaneously after flow management stopped. Nevertheless, similar changes in MMHg have not been observed in a tributary to EFPC.

54 ENVIRONMENTAL SCIENCES↗

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Kinetic Plasma Simulation Capabilities in the MOOSE Framework: Verification of Particle-Particle Collisions

High-fidelity simulations of complex plasma systems allow researchers to gain key insights into and understanding of these systems. To facilitate massively parallel high-fidelity plasma simulations, finite-element-based particle-in-cell capabilities are being developed within the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) based framework called Software for Advanced Large-scale Analysis of MAgnetic confinement for Numerical Design, Engineering & Research (SALAMANDER). While SALAMANDER’s primary objective is modeling edge plasmas and plasma-facing components in fusion devices, the particle-in-cell capabilities being developed are general and will support modeling low-temperature plasmas as well. Previously, collisionless magnetostatic simulation capabilities have been verified with the two-stream and Dorey-Guest-Harris instabilities, and single particle motion. Collisions were implemented using the direct simulation Monte Carlo method, and verification of this capability will be presented here several verification problems: relaxation of a randomly initialized gas to a Maxwellian distribution, Fourier heat flow, and comparison of reaction rates to both analytic calculations and those calculated using a multi-term Boltzmann solver.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Riverbed Temperature and 4D ERT Monitoring Reveals Heterogenous Horizontal and Vertical Groundwater-Surface Water Exchange Flows Under Dynamic Stage Conditions

Groundwater surface water exchange plays a critical role in physical, biological, and geochemical function of coastal and riverine systems. Observing exchange flow behavior in heterogeneous systems is a primary challenge, particularly when flows are governed by dynamic river stage or tidal variations. In this paper we demonstrate a novel application of time-lapse 3D electrical resistivity tomography and temperature monitoring where an array of thermistors installed beneath a riverbed double as resistivity electrodes. We use the array to monitor stage driven exchange flows over a 6-day period in a dynamic, stage-driven high order stream. We present a method for addressing the otherwise confounding effects of the moving river-surface boundary on the raw resistivity data, thereby enabling successful tomographic imaging. Temperature time-series at each thermistor location and time-lapse 3D images of changes in bulk electrical conductivity together provide a detailed description of exchange dynamics over a 10-meter by 45-meter section of the riverbed, to a depth of approximately 5 m. Results reveal highly variable flux behavior throughout the monitoring domain including both horizontal and vertical exchange flows.

54 ENVIRONMENTAL SCIENCES↗

Influence of elevated temperature and oxygen on the capture of radioactive iodine by silver functionalized silica aerogel

Reprocessing is considered a competent strategy for spent nuclear fuel management, yet radioiodine ( 129 I) is emitted in reprocessing off-gas as a hazardous byproduct. Silver functionalized silica aerogel (Ag 0 -aerogel), a promising iodine capture material, experiences a reduction in its capacity after prolonged exposure to off-gas components at elevated temperatures, a phenomenon termed as aging. To fully understand this process, we isolated the contribution of each aging factor, exposing Ag 0 -aerogel samples to N 2 and dry air gas streams, respectively, at 150 °C for different time periods. Aged samples were loaded with I 2 to examine the capacity change and comprehensively characterized to investigate the evolution of their properties. Results show that temperature alone did not alter Ag 0 -aerogel's capacity but triggered Ag 0 nanoparticles sintering and generated organic sulfur species. The presence of O 2 reduced the capacity by ~20 %, causing (i) formation of silver sulfide (Ag 2 S) crystals and (ii) oxidation of Ag-thiolate (Ag-S-r) to Ag sulfonate (Ag-SO 3 -r). Given that Ag 2 S readily adsorbs I 2 , the formation of Ag-SO 3 -r is the major inhibitor for iodine adsorption. This hypothesis was supported by density functional theory (DFT) simulations. These findings unraveled key mechanisms of Ag 0 -aerogel aging, which are useful in the development of materials that withstand realistic spent-nuclear-fuel-reprocessing off-gas conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗