Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Superabsorbing gel for actinide, lanthanide, and fission product decontamination

The present invention provides an aqueous gel composition for removing actinide ions, lanthanide ions, fission product ions, or a combination thereof from a porous surface contaminated therewith. The composition comprises a polymer mixture comprising a gel forming cross-linked polymer and a linear polymer. The linear polymer is present at a concentration that is less than the concentration of the cross-linked polymer. The polymer mixture is at least about 95% hydrated with an aqueous solution comprising about 0.1 to about 3 percent by weight (wt %) of a multi-dentate organic acid chelating agent, and about 0.02 to about 0.4 molar (M) carbonate salt, to form a gel. When applied to a porous surface contaminated with actinide ions, lanthanide ions, and/or other fission product ions, the aqueous gel absorbs contaminating ions from the surface.

Kaminski, Michael D.↗

Lithographic performance evaluation of a contaminated EUV mask after cleaning

The effect of surface contamination and subsequent mask surface cleaning on the lithographic performance of a EUV mask is investigated. SEMATECH's Berkeley micro-field exposure tool (MET) printed 40 nm and 50 nm line and space (L/S) patterns are evaluated to compare the performance of a contaminated and cleaned mask to an uncontaminated mask. Since the two EUV masks have distinct absorber architectures, optical imaging models and aerial image calculations were completed to determine any expected differences in performance. Measured and calculated Bossung curves, process windows, and exposure latitudes for the two sets of L/S patterns are compared to determine how the contamination and cleaning impacts the lithographic performance of EUV masks. The observed differences in mask performance are shown to be insignificant, indicating that the cleaning process did not appreciably affect mask performance.

36 MATERIALS SCIENCE↗

Potential dose distributions at proposed surface radioactvity clearance levels resulting from occupational scenarios.

The purpose of this report is to evaluate the potential dose distribution resulting from surface radioactivity, using occupational radiation exposure scenarios. The surface radioactivity clearance values considered in this analysis may ultimately replace those currently specified in the U.S. Department of Energy (DOE) requirements and guidance for radiological protection of workers, the public and the environment. The surface contamination values apply to radioactive contamination deposited on a surface (i.e., not incorporated into the interior of the material). For these calculations, the dose coefficients for intake of radionuclides were taken from ICRP Publication 68 (ICRP 1994), and external exposure dose coefficients were taken from the compact disc (CD) that accompanied Federal Guidance Report (FGR) 13 (Eckerman et al. 1999). The ICRP Publication 68 dose coefficients were based on ICRP Publication 60 (ICRP 1990) and were used specifically for worker dose calculations. The calculated dose in this analysis is the 'effective dose' (ED), rather than the 'effective dose equivalent' (EDE).

07 ISOTOPE AND RADIATION SOURCES↗

Scatter from optical components; Proceedings of the Meeting, San Diego, CA, Aug. 8-10, 1989

Various papers on scatter from optical components are presented. Individual topics addressed include: BRDF of SiC and Al foam compared to black paint at 3.39 microns, characterization of optical baffle materials, bidirectional transmittance distribution function of several IR materials at 3.39 microns, thermal cycling effects on the BRDF of beryllium mirrors, BTDV of ZnSe with multilayer coatings at 3.39 microns, scattering from contaminated surfaces, cleanliness correlation by BRDF and PFO instruments, contamination effects on optical surfaces, means of eliminating the effects of particulate contamination on scatter measurements of superfine optical surfaces, vacuum BRDF measurement of cryogenic optical surfaces, Monte Carlo simulation of contaminant transport to and deposition on complex spacecraft surfaces, surface particle observation and BRDF predictions, satellite material contaminant optical properties, dark field photographic techniques for documenting optical surface contamination, design of a laboratory study of contaminant film darkening in space, contamination monitoring approaches for EUV space optics.

Stover, John C.↗

Glass particle resuspension from a contaminated (dirty) glass surface

A wealth of adhesion force measurements between a variety of particle/surface pairs have been gathered via Atomic Force Microscopy (AFM) in the past years. However, these measurements deal mostly with clean surfaces and particles for reproducibility. It is therefore up for debate whether particle resuspension could be calculated using these measurements as surrogates for real outdoor particles and surfaces, which often carry both organic and inorganic contaminants (“urban grime”). Two components are necessary to investigate this question: (1) adhesion force measurements on both clean and contaminated surfaces and (2) estimation of particle resuspension from both surface types. In this work, AFM was used to measure the distribution of the adhesion force between a 5-µm clean glass particle and two glass surfaces: the first cleaned according to conventional laboratory standards and a second one left outdoors for six weeks in Albuquerque (New Mexico). The Rock ‘n' Roll model was modified to use experimental adhesion force distributions of arbitrary shape and number of modes instead of a lognormal distribution, as in the original work Reeks & Hall (2001). The results of this analysis showed that the differences in the fraction of particles resuspended were small for a friction velocity of 0.5 m/s but increased for 1 and 2 m/s. For instance, for a friction velocity of 3 m/s, 71% of the original deposit was still on the surface after a day for the clean glass, while only 33% remained on the contaminated glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Arsenic microdistribution and speciation in toenail clippings of children living in a historic gold mining area

Arsenic is naturally associated with gold mineralization and elevated in some soils and mine waste around historical gold mining activity in Victoria, Australia. To explore uptake, arsenic concentrations in children's toenail clippings and household soils were measured, and the microdistribution and speciation of arsenic in situ in toenail clipping thin sections investigated using synchrotron-based X-ray microprobe techniques. The ability to differentiate exogenous arsenic was explored by investigating surface contamination on cleaned clippings using depth profiling, and direct diffusion of arsenic into incubated clippings. Total arsenic concentrations ranged from 0.15 to 2.1 {micro}g/g (n = 29) in clipping samples and from 3.3 to 130 {micro}g/g (n = 22) in household soils, with significant correlation between transformed arsenic concentrations (Pearson's r = 0.42, P = 0.023) when household soil was treated as independent. In clipping thin sections (n = 2), X-ray fluorescence (XRF) mapping showed discrete layering of arsenic consistent with nail structure, and irregular arsenic incorporation along the nail growth axis. Arsenic concentrations were heterogeneous at 10 x 10 {micro}m microprobe spot locations investigated (< 0.1 to 13.3 {micro}g/g). X-ray absorption near-edge structure (XANES) spectra suggested the presence of two distinct arsenic species: a lower oxidation state species, possibly with mixed sulphur and methyl coordination (denoted As{sub (-S, -ch3)}{sup {approx}III}); and a higher oxidation state species (denoted As{sub (-O)}{sup {approx}V}). Depth profiling suggested that surface contamination was unlikely (n = 4), and XRF and XANES analyses of thin sections of clippings incubated in dry or wet mine waste, or untreated, suggested direct diffusion of arsenic occurred under moist conditions. These findings suggest that arsenic in soil contributes to some systemic absorption associated with periodic exposures among children resident in areas of historic gold mining activity in Victoria, Australia. Future studies are required to ascertain if adverse health effects are associated with current levels of arsenic uptake.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nano-machining, surface analysis and emittance measurements of a copper photocathode at SPARC_LAB

R&D activity on Cu photocathodes is under development at the SPARC_LAB test facility to fully characterize each stage of the photocathode “life” and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an increase of intrinsic emittance and consequently a reduction of the overall electron beam brightness. To quantify these effects, we have characterized the photocathode surface in terms of roughness measurement, and morphology and chemical composition analysis by means of Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques. The effects of n-machining on the electron beam quality have been also investigated through emittance measurements before and after the surface processing technique. Finally, we present preliminary emittance studies of yttrium thin film on Cu photocathodes.

36 MATERIALS SCIENCE↗

Effect of hydrocarbon adsorption on the wettability of rare earth oxide ceramics

Vapor condensation is routinely used as an effective means of transferring heat, with dropwise condensation exhibiting a 5 − 7x heat transfer improvement compared to filmwise condensation. However, state-of-the-art techniques to promote dropwise condensation rely on functional hydrophobic coatings, which are often not robust and therefore undesirable for industrial implementation. Natural surface contamination due to hydrocarbon adsorption, particularly on noble metals, has been explored as an alternative approach to realize stable dropwise condensing surfaces. While noble metals are prohibitively expensive, the recent discovery of robust rare earth oxide (REO) hydrophobicity has generated interest for dropwise condensation applications due to material costs approaching 1% of gold; however, the underlying mechanism of REO hydrophobicity remains under debate. In this work, we show through careful experiments and modeling that REO hydrophobicity occurs due to the same hydrocarbon adsorption mechanism seen previously on noble metals. To investigate adsorption dynamics, we studied holmia and ceria REOs, along with control samples of gold and silica, via X-Ray photoelectron spectroscopy (XPS) and dynamic time-resolved contact angle measurements. The contact angle and surface carbon percent started at ≈0 on in-situ argon-plasma-cleaned samples and increased asymptotically over time after exposure to laboratory air, with the rare earth oxides displaying hydrophobic (>90°) advancing contact angle behavior at long times (>4 days). The results indicate that REOs are in fact hydrophilic when clean and become hydrophobic due to hydrocarbon adsorption. Furthermore, this study provides insight into how REOs can be used to promote stable dropwise condensation, which is important for the development of enhanced phase change surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving the Performance of Mid-T Baked Niobium Cavities through Post-Bake Surface Treatment

he Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, Vijay [Fermilab]↗

Improving the performance of mid-T baked niobium cavities through post-bake surface treatment

The Medium temperature (mid-T) baking of niobium superconducting radio-frequency cavities at 300 350 C in a vacuum furnace is known to enhance the quality factor (Q₀). However, despite this improvement, cavities treated with this process often exhibit premature quench at relatively low accelerating fields. This limitation is suspected to arise from the formation of surface contaminants, such as niobium carbides, during the furnace bake at 350 C for 3 h. To investigate the influence of potential surface contamination, this study applied an ultralight chemical removal to 1.3 GHz and 650 MHz single-cell cavities that had undergone medium-temperature baking. The removal of the top RF surface layer led to a notable improvement in the quench field and Q₀, indicating a beneficial effect of eliminating possible surface residues introduced during the bake.

Chouhan, V. [Fermilab] (ORCID:0000000282004931)↗

Spent Fuel Storage Operational Experience With Increased Crud Activities

A significant part of the electricity production in Hungary is provided by 4 units of VVER 440 nuclear reactors at the Paks Nuclear Power Plant. Interim dry storage of the spent fuel assemblies that are generated during the operation of the reactors is provided in a Modular Vault Dry Storage (MVDS) facility that is located in the immediate vicinity of the Paks Nuclear Power Plant. The storage capacity of the MVDS is being continuously extended in accordance with spent the fuel production rate from the four reactors. An accident occurred at unit 2 of the Paks Nuclear Power Plant in 2003, when thirty irradiated fuel assemblies were damaged during a cleaning process. The fuel assemblies were not inside the reactor at the time of the accident, but in a separate tank within the adjacent fuel decay pool. As a result of this accident, contamination from the badly damaged fuel assemblies spread to the decay pool water and also became deposited onto the surface of (hermetic) spent fuel assemblies within the decay pool. Therefore, it was necessary to review the design basis of the MVDS and assess the effects of taking the surface contaminated spent fuel assemblies into dry storage. The contaminated hermetic assemblies were transferred from the unit 2 pool to the interim storage facility in the period between 2005 and 2007. Continuous inspection and measurement was carried out during the transfer of these fuel assemblies. On the basis of the design assessments and measurement of the results during the fuel transfer, it was shown that radiological activity values increased due to the consequences of the accident but that these levels did not compromise the release and radiation dose limits for the storage facility. The aim of this paper is to show the effect on the operation of the MVDS interim storage facility as a result of the increased activity values due to the accident that occurred in 2003, as well as to describe the measurements that were taken, and their results and experience gained. In summary: On the basis of the design assessments and measurement of the results during the fuel transfer operations, it was shown that radiological activity values increased due to the consequences of the 2003 accident but that these levels did not compromise the release and dose limits for the fuel storage facility. In the environment there was no measurable radioactivity as a result of the operation of the Paks ISFSI. The exposure of the surrounding population was calculated on measured releases and meteorological data. The calculations show negligible doses until 2004. Due to the increased surface contamination on the spent fuel assemblies the dose rate increased almost 5 times compared to the least annual value, but still less then 0.01 percent of the allowed dose restriction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPRI Report: Review of Geostatistical Approaches to Characterization of Subsurface Contamination - 17442

The key metric in the final release of a nuclear facility from radiological controls following plant decommissioning is the potential long-term radiation exposure to future users of the site. This is estimated from modeling of the exposure that could conceivably result from residual contamination remaining on the site in buildings, soil and groundwater after the completion of decontamination, dismantlement and remediation activities. A key input to such modelling is characterization data obtained from surveys and sampling. To date, the regulatory guidance for conducting the final status survey required to show compliance with regulator approved site release limits (i.e., radionuclide concentrations or contamination levels) has been limited to surface contamination. EPRI has completed a project that provides guidance for use of geo-statistics in the development of a site final status survey that will address the impact of dose to a future user of the site from subsurface contamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Contamination Model Predictions to LDEF Surface Measurements

Contaminant deposition measurements have been made on species content and depth profiles on three experiments trays from the Long Duration Exposure Facility (LDEF), Auger, Argon sputtering, Electron Spectroscopy for Chemical Analysis (ESCA) and Scanning Electron Microscopy (SEM) analysis. The integrated spacecraft environment model (ISEM) was used to predict the deposition levels of the contaminants measured on the three trays. The details of the modeling and assumptions used are presented along with the predictions for the deposition on select surfaces on the trays. These are compared to the measured results. The trays represent surfaces that have a high atomic oxygen flux, and intermediate oxygen flux, and no oxygen flux. All surfaces received significant solar Ultraviolet flux. It appears that the atomic oxygen was the primary agent that caused significant deposition to occur. Surfaces that saw significant contaminant flux solar UV and no atomic oxygen did not show any appreciable levels of observable deposition. The implications of the atom ic oxygen interaction with contaminant deposits containing silicon contaminant sources is discussed. The primary contaminant sources are DC61104 adhesive and Z306 paint. The results and interpretation of the findings have a potential significant impact on spacecraft surfaces that are exposed to solar UV and atomic oxygen in low Earth orbit.

Gordon, Tim↗

ASSESMENT OF IMPURITIES IN NP METAL USING DOUBLE-FOCUSING SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards [1]. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing [2], with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture [2]. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of na

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elemental Analyses of Hypervelocity Microparticle Impact Sites on Interplanetary Dust Experiment Sensor Surfaces

The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to breakdown the 0.4 or 1.0 micron thick SiO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results classification resulted from the particles' origins as 'manmade', 'natural', or 'indeterminate'. The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters, of these features. Thus far, a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF were analyzed: 36 from tray C-9 (Leading (ram), or east, side), 18 from tray C-3 (Trailing (wake), or west, side), 12 from tray B-12 (north side), 4 from tray D-6 (south side), 3 from tray H-11 (space end), and 6 from tray G-10 (earth end). Residue from manmade debris was identified in craters on all trays (aluminum oxide particle residues were not detectable on the Al/Si substrates). These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the west, space, and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the east, north, and south sides of the satellite, denoting passage through orbital debris clouds or rings.

Simon, C. G.↗

Elemental analyses of hypervelocity microparticle impact sites on Interplanetary Dust Experiment sensor surfaces

The Interplanetary Dust Experiment (IDE) had over 450 electrically active ultra-high purity metal-oxide-silicon impact detectors located on the six primary sides of the Long Duration Exposure Facility (LDEF). Hypervelocity microparticles (approximately 0.2 to approximately 100 micron diameter) that struck the active sensors with enough energy to break down the 0.4 or 1.0 micron thick SIO2 insulator layer separating the silicon base (the negative electrode), and the 1000 A thick surface layer of aluminum (the positive electrode) caused electrical discharges that were recorded for the first year of orbit. The high purity Al-SiO2-Si substrates allowed detection of trace (ppm) amounts of hypervelocity impactor residues. After sputtering through a layer of surface contamination, secondary ion mass spectrometry (SIMS) was used to create two-dimensional elemental ion intensity maps of microparticle impact sites on the IDE sensors. The element intensities in the central craters of the impacts were corrected for relative ion yields and instrumental conditions and then normalized to silicon. The results were used to classify the particles' origins as 'manmade,' 'natural,' or 'indeterminate.' The last classification resulted from the presence of too little impactor residue, analytical interference from high background contamination, the lack of information on silicon and aluminum residues, or a combination of these circumstances. Several analytical 'blank' discharges were induced on flight sensors by pressing down on the sensor surface with a pure silicon shard. Analyses of these blank discharges showed that the discharge energy blasts away the layer of surface contamination. Only Si and Al were detected inside the discharge zones, including the central craters of these features. Thus far a total of 79 randomly selected microparticle impact sites from the six primary sides of the LDEF have been analyzed: 36 from tray C-9 (Leading (ram), or East, side), 18 from tray C-3 (Trailing (wake), or West, side), 12 from tray B-12 (North side), 4 from tray D-6 (South side), 3 from tray H-11 (Space end), and 6 from tray G-10 (Earth end). Residue from manmade debris was identified in craters on all trays. (Aluminum oxide particle residues were not detectable on the Al/Si substrates.) These results were consistent with the IDE impact record which showed highly variable long term microparticle impact flux rates on the West, Space and Earth sides of the LDEF which could not be ascribed to astronomical variability of micrometeorite density. The IDE record also showed episodic bursts of microparticle impacts on the East, North, and South sides of the satellite, denoting passage through orbital debris clouds or rings.

Simon, Charles G.↗