Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron X-ray fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Chemical Potential Driven Reorganization of Anions between Stern and Diffuse Layers at the Air/Water Interface

We report ion adsorption and transfer at charged interfaces play key roles in various industrial and environmental processes. Molecular scale details of ion-ion, ion-water, and ion-surface interactions are still debated. Complex ions, such as SCN - and SeCN - , are particularly interesting due to their unexpected adsorption trends. Here, we combine vibrational sum frequency generation (VSFG) spectroscopy and surface-sensitive synchrotron X-ray studies to provide a detailed description of SeCN - adsorption at a floating charged monolayer. Polarimetry studies show that the average orientation of SeCN - anions with respect to the surface normal decreases from 45° to 22° with the increasing KSeCN concentration. Interfacial SeCN - coverage saturates at very low bulk concentrations, but their orientational organization, distribution between Stern and diffuse layers, and effects on the hydrogen-bonding network of the interfacial water continue to change with increasing bulk KSeCN concentration. These results show that the increasing chemical potential may lead to further reorganization of the adsorbed ions, even though the total interfacial ion population does not change. The reorganization of the interfacial ions and the water may be very important in chemical separations of heavy metals, where metal-anion complexes drive the selective ion transfer at aqueous interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescent Applications to Crystallization

By covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and tests with model proteins have shown that labeling u to 5 percent of the protein molecules does not affect the X-ray data quality obtained . The presence of the trace fluorescent label gives a number of advantages. Since the label is covalently attached to the protein molecules, it "tracks" the protein s response to the crystallization conditions. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a darker background. Non-protein structures, such as salt crystals, do not show up under fluorescent illumination. Crystals have the highest protein concentration and are readily observed against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. Preliminary tests, using model proteins, indicates that we can use high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that more rapid amorphous precipitation kinetics may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Experiments are now being carried out to test this approach using a wider range, of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Thermal cycling-driven microstructural changes of eutectic Al–Si phase change materials in SS304 containers revealed by multi-modal imaging

Aluminum-based Al–Si alloys are widely used as phase change materials (PCMs) in thermal energy storage (TES) systems owing to their high volumetric latent heat and superior thermal conductivity. However, their long-term reliability is limited by degradation processes that remain insufficiently understood. In this work, we employ a multimodal, correlative characterization framework to systematically resolve the degradation behavior of eutectic Al–Si PCMs in contact with SS304 containers under repeated thermal cycling. By integrating high-resolution electron microscopy, three-dimensional X-ray fluorescence (3D XRF) imaging, and differential scanning calorimetry (DSC), we directly link spatially resolved compositional and microstructural evolution to changes in thermophysical properties. The correlative analysis reveals that elemental leaching of Fe, Cr, and Ni from the stainless-steel container into the PCM drives the formation of intermetallic compounds (IMCs) both at the interface and within the bulk PCM, leading to pronounced compositional heterogeneity. These interfacial reactions and diffusion-induced transformations progressively destabilize the Al–Si eutectic, reducing the effective phase-transforming fraction. Consistent with these observations, DSC measurements show a decrease in melting temperature and latent heat of fusion with thermal cycling. These results underscore the critical influence of interfacial reactions and material compatibility on the stability, durability, and overall performance of Al–Si-based TES systems.

25 ENERGY STORAGE↗

Fluorescent Approaches to High Throughput Crystallography

We have shown that by covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and the presence of the probe at low concentrations does not affect the X-ray data quality or the crystallization behavior. The presence of the trace fluorescent label gives a number of advantages when used with high throughput crystallizations. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a dark background. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Brightly fluorescent crystals are readily found against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. We are now testing the use of high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that kinetics leading to non-structured phases may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Preliminary experiments with test proteins have resulted in the extraction of a number of crystallization conditions from screening outcomes based solely on the presence of bright fluorescent regions. Subsequent experiments will test this approach using a wider range of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Satellites, core hole excitations, and spin-resolved electronic structure in the spectroscopy of half-metallic CrO 2

Photoelectron satellites—the structures appearing on the low kinetic or high binding-energy side of the “main” or “elastic” photopeak—betray the complex many-body interactions set in motion by the sudden creation of the core hole. In this work, we demonstrate, using the technologically important ferromagnetic half-metal CrO 2 , how such satellites can manifest themselves in other core-level spectroscopies of the material and how they can reveal important details pertinent to its electronic structure. Specifically, we identify a fluorescence satellite in the Cr 𝐿 3 resonant x-ray-emission spectra that radiates at a constant emission energy across the Cr 𝐿 3 x-ray edge with energy ≈1.3 eV above the ordinary valence fluorescence. Here, we provide evidence that this feature arises from the valence recombination of the Cr 2⁢𝑝 core hole “dressed” by the same shakeup charge-transfer process present in both the Cr x-ray photoelectron and the Cr x-ray absorption spectra with its energy uniquely measuring the exchange splitting of the Cr 3⁢𝑑 level. Further analysis of the x-ray emission data reveals three additional features that radiate at constant loss energy that are attributed to combinations of Cr 3⁢𝑑⁢(𝑡 2⁢𝑔 ) → Cr 3⁢𝑑⁢(𝑡 2⁢𝑔 ), charge-transfer O 2⁢𝑝→Cr 3⁢𝑑, and crystal-field Cr⁢ 3⁢𝑑⁡(𝑡 2⁢𝑔 )→Cr⁢ 3⁢𝑑⁡(𝑒 𝑔 ) excitations. These assignments and their energies are supported by density-functional theory calculations, the accuracy of which we demonstrate by hard x-ray valence-photoemission measurements. Atomic multiplet calculations, which include crystal-field effects, help interpret x-ray photoelectron and x-ray absorption spectra of the covalently mixed Cr ion. Resonant Cr K-𝐿 2,3 ⁢𝐿 2,3 Auger-electron emission spectra support a ligand-to-metal nature of the charge-transfer process while highlighting the charge sensitivity differences between photon-in/electron-out and photon-in/photon-out spectroscopies.

36 MATERIALS SCIENCE↗

Assessing Metal Ion Assignment Accuracy in Protein Data Bank Models via Elemental Spectroscopy

Accurate representation of metal ions in macromolecular structures is critical for chemical interpretation, computational modeling, and machine-learning methods that rely on Protein Data Bank (PDB) entries. However, the elemental identity of metals modeled in crystallographic structures is often inferred indirectly and rarely validated experimentally. Here, we combine Particle Induced X-ray Emission (PIXE) and X-ray Fluorescence Spectroscopy (XRFS) to determine the elemental composition of protein samples used to generate 70 deposited metalloprotein crystal structures. By analyzing the original protein material employed for crystallization, but before the addition of crystallization buffer solutions, we assess whether the modeled metal ions in deposited structures are consistent with experimentally detectable elemental content. We find that in a majority of cases, the metals modeled in the corresponding PDB entries are inconsistent with the metals present in the protein samples before crystallization, or that additional metals are present but not represented in the structural models. Spectroscopic results were integrated with automated crystallographic validation metrics, including real-space Z-difference (RSZD) analysis and systematic rerefinement, to evaluate atomic-number mismatch at metal sites. PIXE and XRFS show strong agreement for dominant elemental signals and provide complementary, scalable approaches for identifying suspect metal assignments. This work does not address physiological or functional metalation but instead highlights a widespread data integrity issue in deposited macromolecular structures, PDB-wide. These results establish an experimentally corroborated link between elemental identity and crystallographic validation metrics, enabling the large-scale detection of chemically inconsistent annotations in structural databases used for computational modeling and machine learning.

Crystallization↗

Spatiotemporal and Statistical Mapping of Transition Metal Equilibria in Alkaline Media

Transition metal dissolution and redeposition (D/R) kinetics in alkaline media play a critical role in various chemical and electrochemical processes. Competitive reaction kinetics between different transition metals can modulate individual metal behavior in these processes. To date, these phenomena have remained largely unmeasured, and even when captured, they are difficult to statistically characterize due to their dynamic nature, simultaneous occurrence, and spatially heterogeneous nature. Here, in this study, we develop a statistical analysis framework based on in situ and operando X-ray fluorescence microscopy (XFM) to investigate the relative D/R kinetics of multiple transition metals in alkaline media. By employing statistical analysis, we quantify the spatial distribution of D/R species and assess the rate at which the system reaches equilibrium under varying reaction conditions. We show that pH does not simply change the rate of dissolution and redeposition, but reorganizes the cross-element kinetic correlations among Ni, Fe, and Mn and accelerates the spatial equilibration of D/R events, as quantified through correlation analysis, reaction-rate estimation, probability function distributions, and texture-based monitoring statistics. Additionally, we demonstrate how modifying the solvent environment can influence D/R kinetics, providing a pathway for tuning materials synthesis and process optimization. Our study offers valuable insights into the complex interplay between different transition metals and provides a reliable statistical framework for spatial analysis of diverse imaging data sets, enabling deeper extraction of latent information across multiple modalities.

36 MATERIALS SCIENCE↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, 51%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear hits. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically can not reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of a macromolecules purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals will show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "bits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Minamitani, Elizabeth Forsythe↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disentangling the evolution of electrons and holes in photoexcited ZnO nanoparticles

The evolution of charge carriers in photoexcited room temperature ZnO nanoparticles in solution is investigated using ultrafast ultraviolet photoluminescence spectroscopy, ultrafast Zn K-edge absorption spectroscopy, and ab initio molecular dynamics (MD) simulations. The photoluminescence is excited at 4.66 eV, well above the band edge, and shows that electron cooling in the conduction band and exciton formation occur in <500 fs, in excellent agreement with theoretical predictions. The x-ray absorption measurements, obtained upon excitation close to the band edge at 3.49 eV, are sensitive to the migration and trapping of holes. They reveal that the 2 ps transient largely reproduces the previously reported transient obtained at 100 ps time delay in synchrotron studies. In addition, the x-ray absorption signal is found to rise in ∼1.4 ps, which we attribute to the diffusion of holes through the lattice prior to their trapping at singly charged oxygen vacancies. Indeed, the MD simulations show that impulsive trapping of holes induces an ultrafast expansion of the cage of Zn atoms in <200 fs, followed by an oscillatory response at a frequency of ∼100 cm−1, which corresponds to a phonon mode of the system involving the Zn sub-lattice.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Arsenic hyperaccumulator Pteris vittata shows reduced biomass in soils with high arsenic and low nutrient availability, leading to increased arsenic leaching from soil

Plant-soil interactions affect arsenic and nutrient availability in arsenic-contaminated soils, with implications for arsenic uptake and tolerance in plants, and leaching from soil. In 22-week column experiments, we grew the arsenic hyperaccumulating fern Pteris vittata in a coarse- and a medium-textured soil to determine the effects of phosphorus fertilization and mycorrhizal fungi inoculation on P. vittata arsenic uptake and arsenic leaching. We investigated soil arsenic speciation using synchrotron-based spectromicroscopy. Greater soil arsenic availability and lower nutrient content in the coarse-textured soil were associated with greater fern arsenic uptake, lower biomass (apparently a metabolic cost of tolerance), and arsenic leaching from soil, due to lower transpiration. P. vittata hyperaccumulated arsenic from coarse- but not medium-textured soil. Mass of plant-accumulated arsenic was 1.2 to 2.4 times greater, but aboveground biomass was 74% smaller, in ferns growing in coarse-textured soil. In the presence of ferns, mean arsenic loss by leaching was 195% greater from coarse- compared to the medium-textured soil, and lower across both soils compared to the absence of ferns. In the medium-textured soil arsenic concentrations in leachate were higher in the presence of ferns. Fern arsenic uptake was always greater than loss by leaching. Most arsenic (>66%) accumulated in P. vittata appeared of rhizosphere origin. In the medium-textured soil with more clay and higher nutrient content, successful iron scavenging increased arsenic release from soil for leaching, but transpiration curtailed leaching.

59 BASIC BIOLOGICAL SCIENCES↗

Tonian Carbonates Record Phosphate-Rich Shallow Seas

The early-middle Neoproterozoic is thought to have witnessed significant perturbations to marine P cycling, in turn facilitating the rise of eukaryote-dominated primary production. However, with few robust constraints on aqueous P concentrations, current understanding of Neoproterozoic P cycling is generally model-dependent. To provide new geochemical constraints, we combined microanalytical data sets with solid-state Nuclear Magnetic Resonance, synchrotron-based X-ray Absorption Near Edge Structure spectroscopy, and micro-X-ray Fluorescence imaging to characterize the speciation and distribution of P in Tonian shallow-water carbonate rocks. These data reflect shallow water phosphate concentrations 10–100× higher than modern systems, supporting the hypothesis that tectonically-driven influxes in P periodically initiated kinetically-controlled CaCO 3 deposition, in turn destabilizing marine carbonate chemistry, climate, and nutrient inventories. Alongside these observations, a new compilation and statistical analysis of mudstone geochemistry data indicates that, in parallel, C org and P burial increased across later Tonian continental margins until becoming decoupled at the close of the Tonian, implicating widespread N-limitation triggered by increasing atmospheric O 2 .

58 GEOSCIENCES↗

Local halide heterogeneity drives surface wrinkling in mixed-halide wide-bandgap perovskites

Compositional heterogeneity in wide-bandgap (1.8 - 2.1 eV) mixed-halide perovskites is a key bottleneck in the processing of high-quality solution-processed thin films and prevents their application in efficient multijunction solar cells. Notably, mixed-cation (formamidinium-methylammonium) wide-bandgap perovskite films are prone to form micrometer-scale wrinkles which can interfere with the smooth surfaces ideal for multijunction devices. Here, we study the formation dynamics of wrinkled mixed-halide perovskite films and its impact on the local composition and optoelectronic properties. We use in situ X-ray scattering during perovskite film formation to show that crystallization of bromide-rich perovskites precedes that of mixed-halide phases in wrinkled films cast using an antisolvent-based process. Using nanoscopic X­-ray fluorescence and hyperspectral photoluminescence imaging, we also demonstrate the formation of iodide- and bromide-rich phases in the wrinkled domains. This intrinsic spatial halide segregation results in an increased local bandgap variation and Urbach energy. Morphological disorder and compositional heterogeneity also aggravate the formation of sub-bandgap electronic defects, reducing photostability and accelerating light-induced segregation of iodide and bromide ions in thin films and solar cells.

36 MATERIALS SCIENCE↗

Systematic characterization of selenium speciation in coal fly ash

Millions of tons of coal fly ashes (CFAs) are produced annually during coal combustion in the U.S., which are commonly beneficially used in the concrete industry or disposed of in ash ponds. CFAs contain trace amounts of a range of toxic heavy metals including selenium (Se). Because the toxicity of Se is dependent on its speciation, investigating Se speciation in CFAs as affected by coal source and combustion conditions can help understand the related environmental and human health impacts during disposal or beneficial reuse. In this study, a set of representative CFA samples were characterized for Se speciation using synchrotron X-ray absorption spectroscopy (XAS) and micro-X-ray fluorescence spectromicroscopy (μ-XRF/XAS). Se-containing particles were highly heterogeneous, and individual particles might contain multiple oxidation states including Se(0), Se(IV), and Se(VI). Principal component analysis was performed for sample characteristics including Al 2 O 3 , SiO 2 , CaO, FeO, loss on ignition, average particle size, Se concentration, and Se oxidation state. Selective catalytic reduction (SCR), which is used to limit nitrogen oxide (NO x ) emissions during coal combustion, was found to be associated with the presence of reduced Se oxidation states, with up to 90% Se(0) observed in samples with SCR. Alongside SCR, FeO content may also influence Se speciation.

01 COAL, LIGNITE, AND PEAT↗