Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature control applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

NO x adsorption with CO and C 2 H 4 on Pd/SSZ-13: Experiments and modeling

A transient monolith model containing microkinetic schemes for NO uptake and release over Pd/SSZ-13 without and with reductants CO or C2H4 is presented. The scheme involves three cationic Pd species (Z – [PdOH] + , Z – Pd 2+ Z – , Z – Pd + ) as the active sites during uptake of NO, CO and C 2 H 4 , and their desorption and conversion at higher temperature. Kinetic parameters are estimated through a combination of density functional theory (DFT) estimates and a fit of uptake, desorption and conversion data. The tuned model is validated at different uptake temperatures, ramp rates, and flowrates. A “degree of uptake control” parameter is defined that helps to identify the step(s) that are uptake controlling. The model helps to interpret the data features and is used to identify operating conditions to meet application-relevant performance metrics, including NO trapping efficiency and NO release temperature. Furthermore, the model demonstrates higher NO uptake on Pd/SSZ-13 compared to Pd/ZSM-5.

42 ENGINEERING↗

Stress-Controlled Creep–Fatigue of an Advanced Austenitic Stainless Steel at Elevated Temperatures

Creep–fatigue interaction occurs in many structural components of high-temperature systems operating under cyclic and steady-state service conditions, such as in nuclear power plants, aerospace, naval, and other industrial applications. Thus, understanding micromechanisms governing high-temperature creep–fatigue behavior is essential for safety and design considerations. In this work, stress-controlled creep–fatigue tests of advanced austenitic stainless steel (Alloy 709) were performed at a 400 MPa stress range and 750 °C with tensile hold times of 0, 60, 600, 1800, and 3600 s, followed by microstructural examinations. The creep–fatigue lifetime of the Alloy 709 was found to decrease with increasing hold time until reaching a saturation level where the number of cycles to failure did not exhibit a significant decrease. Softening behavior was observed at the beginning of the test, possibly due to the recovery of entangled dislocations and de-twining. In addition, hysteresis loops showed ratcheting behavior, although the mean stress was zero during creep–fatigue cycling, which was attributed to activity of partial dislocations. Microstructural examination of the fracture surfaces showed that fatigue failure dominated at small hold times where the cracks initiated at the surface of the sample. Larger creep cracks were found for longer hold times with a lower probability of dimpled cavities, indicating the dominance of creep deformation. The results were compared with other commonly used stainless steels, and plausible reasons for the observed responses were described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas Flow Detection System

This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at thermal equilibrium with the test flow of GN2. The temperature drop of each branch from its "no flow" stable temperature peak to its stable "with flow" temperature will allow the operator to determine whether a minimum level of flow exists. An alternative operation has the operator turning on the software only long enough to record the ambient temperature of the tubing before turning on the heaters and initiating GN2 flow. The stable temperature of the heated tubing with GN2 flow is then compared with the ambient tubing temperature to determine if flow is present in each branch. To help quantify the level of flow in the manifolds, each branch will be bench calibrated to establish its thermal properties using the flow detection system and different flow rates. These calibration values can then be incorporated into the software application to provide more detailed flow rate information.

Moss, Thomas↗

Development of an Emulation-simulation Thermal Control Model for Space Station Application

Analysis techniques to evaluate the effects of changing thermal loads and the methods utilized to control temperature distributions in the orbital space station are essential. Analysis techniques including a user-friendly computer program, were developed which should prove useful in thermal design and system analysis of the the space station. The program uses a data base and user input to compute costs, sizes, and power requirements for individual components and complete systems. User input consists of selecting mission parameters, selecting thermal acquisition configurations, transport systems and distances, and thermal rejection configurations.

Colwell, G. T.↗

Prediction of The TREAT Facility Power and Temperature of Sirius-2c Nuclear Propulsion Fuel Experiment

This paper presents simulation results of the Sirius-2c full power experiment that was performed at the TREAT facility to support experiment modeling and transient analysis of the NASA-sponsored Sirius series of experiments for nuclear thermal propulsion applications. We presents a novel approach to predict the control rod motion and power of the reactor and the temperature of the specimen during transient experiments using the Griffin and Bison packages of the Multiphysics Object Oriented Simulation Environment (MOOSE). First, the model predicts the transient rod motion that results in the desired reactor power shape. Then, the temperature of the specimen is predicted based on the power deposited in the specimen. The prediction results are in good agreement with the measured reactor power and control rod position and over-predicted the specimen temperature which is mainly related to specimen surface emissivities. The reactor reaches a peak power of 80 MW and a specimen temperature of 2500 K and considering the right specimen emissivities the predicted temperature is in an excellent agreement with the measured values. This model can be utilized in helping and supporting the design and optimization a new experiments that are going to be irradiated in the TREAT facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-consistent equilibrium and transport simulations for NSTX-U plasmas enhanced via machine learning surrogate models

The Control-Oriented Transport SIMulator (COTSIM) is an advanced equilibrium and transport code designed for simulating tokamak discharges at computational speeds suitable for control applications. COTSIM’s modular framework enables users to select models that balance accuracy with speed according to specific needs, allowing the code to operate from fast to faster-than-real-time performance levels. This work presents recent enhancements to COTSIM’s predictive accuracy for NSTX-U scenarios, achieved by integrating neural-network-based surrogate models and self-consistent equilibrium calculations. To improve source deposition predictions, a surrogate model for NUBEAM has been incorporated. Additionally, a surrogate model for the Multi-Mode Module (MMM) now supports predictions of anomalous thermal, momentum, and particle diffusivities—key factors for modeling the evolution of temperature and rotation. Each surrogate model was specifically trained for the NSTX-U operational regime to enhance COTSIM’s accuracy while maintaining computational efficiency. Moreover, COTSIM now couples fixed-boundary equilibrium solvers with its transport solvers, enabling self-consistent predictions of plasma profiles and equilibrium evolution over the discharge. Simulation results demonstrate strong agreement between COTSIM and TRANSP predictions for NSTX-U discharges. These substantial advancements expand COTSIM’s utility in model-based control applications for NSTX-U. Potential applications include simultaneous optimization of equilibrium and transport scenarios, integration into digital twins, real-time profile estimation (e.g., temperature and rotation) from limited or noisy measurements, and advanced feedback-based scenario control.

Equilibrium and transport modeling↗

Chemical Tuning Meets 2D Molecular Magnets

Two-dimensional (2D) magnets provoke a surge of interest in large anisotropy in reduced dimensions and are promising for next-generation information technology where dynamic magnetic tuning is essential. Until recently, the crucial metal-organic magnet Cr(pyz) 2 ∙xLiCl∙yTHF with considerable high coercivity and high-temperature magnetic order opens up a new platform to control magnetism in metal-organic materials at room temperature. Here we report an in-situ chemical tuning route to realize the controllable transformation of low-temperature magnetic order into room-temperature hard magnetism in Cr(pyz) 2 ∙xLiCl∙yTHF. The chemical tuning via electrochemical lithiation and solvation/desolvation exhibits continuously variable magnetic features from cryogenic magnetism to the room-temperature optimum performance of coercivity (H c ) of 8500 Oe and energy product of 0.6 MGOe. Such chemically flexible tunability of room-temperature magnetism is ascribed to the different degrees of lithiation and solvation that modify the stoichiometry and Cr-pyrazine coordination framework. Furthermore, the additively manufactured hybrid magnets show air stability and electromagnetic induction, providing potential applications. Our findings here suggest chemical tuning as a universal approach to control the anisotropy and magnetism of 2D hybrid magnets at room temperature, promising for data storage, magnetic refrigeration, and spintronics.

36 MATERIALS SCIENCE↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Microelectrophoretic apparatus and process

New gel tray and lid assemblies designed for use in conjunction with slotted electrophoretic membranes were developed to take advantage of recently improved microelectrophoretic accessories which include a multisample applicator capable of applying up to 10 samples consecutively or simultaneously, and a temperature control plate for dissipating the heat produced by electrophoresis in a gel. The trays and membranes can be marketed ready for use as electrophoretic media or impregnated with various specific substrates and dyes

Grunbaum, B. W.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Those aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described with emphasis on the instrumentation and data acquisition system used in the Langley 0.3 m transonic cryogenic tunnel. Typical calibration results obtained in a 20 by 60 cm two dimensional test section are included.

Ladson, C. L.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described. The instrumentation and data acquisition system used in the 0.3-m transonic cryogenic tunnel along with typical calibration data obtained in a 20 by 60 cm two dimensional test section are described.

Ladson, C. L.↗

Miniaturized Cassegrainian concentrator concept demonstration

High concentration ratio photovoltaic systems for space applications have generally been considered impractical because of perceived difficulties in controlling solar cell temperatures to reasonably low values. A miniaturized concentrator system is now under development which surmounts this objection by providing acceptable solar cell temperatures using purely passive cell cooling methods. An array of identical miniaturized, rigid Cassegrainian optical systems having a low f-number with resulting short dimensions along their optical axes are rigidly mounted into a frame to form a relatively thin concentrator solar array panel. A number of such panels, approximately 1.5 centimeters thick, are wired as an array and are folded against one another for launch in a stowed configuration. Deployment on orbit is similar to the deployment of conventional planar honeycomb panel arrays or flexible blanket arrays. The miniaturized concept was conceived and studied in the 1978-80 time frame. Progress in the feasibility demonstration to date is reported.

Patterson, R. E.↗

The Lewis Strain Gauge Laboratory: Status and plans

An in-house lab was established for developing, testing, and evaluating high-temperature strain gauges and to aid in in-house applications of high-temperature strain instrumentation. The lab is automated to provide computer control of oven temperatures, imposed strain, and data sampling.

Hobart, Howard F.↗

Cryogenic Behavior of the High Temperature Crystal Oscillator PX-570

Microprocessors, data-acquisition systems, and electronic controllers usually require timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that utilize crystal oscillators due to availability, cost, ease of operation, and accuracy. Stability of these oscillators, i.e. crystal characteristics, is usually governed, amongst other things, by the ambient temperature. Operation of these devices under extreme temperatures requires, therefore, the implementation of some temperature-compensation mechanism either through the manufacturing process of the oscillator part or in the design of the circuit to maintain stability as well as accuracy. NASA future missions into deep space and planetary exploration necessitate operation of electronic instruments and systems in environments where extreme temperatures along with wide-range thermal swings are countered. Most of the commercial devices are very limited in terms of their specified operational temperature while very few custom-made and military-grade parts have the ability to operate in a slightly wider range of temperature. Thus, it is becomes mandatory to design and develop circuits that are capable of operation efficiently and reliably under the space harsh conditions. This report presents the results obtained on the evaluation of a new (COTS) commercial-off-the-shelf crystal oscillator under extreme temperatures. The device selected for evaluation comprised of a 10 MHz, PX-570-series crystal oscillator. This type of device was recently introduced by Vectron International and is designed as high temperature oscillator [1]. These parts are fabricated using proprietary manufacturing processes designed specifically for high temperature and harsh environment applications [1]. The oscillators have a wide continuous operating temperature range; making them ideal for use in military and aerospace industry, industrial process control, geophysical fields, avionics, and engine control. They exhibit low jitter and phase noise, consume little power, and are suited for high shock and vibration applications. The unique package design of these crystal oscillators offers a small ceramic package footprint, as well as providing both through-hole mounting and surface mount options.

Patterson, Richard↗

Land Surface Temperature from GOES-East and GOES-West

Land surface temperature (LST) is an important climate parameter that controls the surface energy budget. For climate applications, information is needed at the global scale with representation of the diurnal cycle. To achieve global coverage there is a need to merge about five independent geostationary (GEO) satellites that have different observing capabilities. An issue of practical importance is the merging of independent satellite observations in areas of overlap. An optimal approach in such areas could eliminate the need for redundant computations by differently viewing satellites. We use a previously developed approach to derive information on LST from GOES-East (GOES-E), modify it for application to GOES-West (GOES-W) and implement it simultaneously across areas of overlap at 5-km spatial resolution. We evaluate the GOES-based LST against in situ observations and an independent MODIS product for the period of 2004–09. The methodology proposed minimizes differences between satellites in areas of overlap. The mean and median values of the differences in monthly mean LST retrieved from GOES-E and GOES-W at 0600 UTC for July are 0.01 and 0.11 K, respectively. Similarly, at 1800 UTC the respective mean and median value of the differences were 0.15 and 1.33 K. These findings can provide guidelines for potential users to decide whether the reported accuracy based on one satellite alone, meets their needs in area of overlap. Since the 6 yr record of LST was produced at hourly time scale, the data are well suited to address scientific issues that require the representation of LST diurnal cycle or the diurnal temperature range (DTR).

54 ENVIRONMENTAL SCIENCES↗

Packaging Technology Developed for High-Temperature SiC Sensors and Electronics

A ceramic- and thick-film-materials-based prototype electronic package designed for silicon carbide (SiC) high-temperature sensors and electronics has been successfully tested at 500 C in an oxygen-containing air environment for 500 hours. This package was designed, fabricated, assembled, and electronically evaluated at the NASA Glenn Research Center at Lewis Field with an in-house-fabricated SiC semiconductor test chip. High-temperature electronics and sensors are necessary for harsh-environment space and aeronautical applications, such as space missions to the inner solar system or the emission control electronics and sensors in aeronautical engines. Single-crystal SiC has such excellent physical and chemical material properties that SiC-based semiconductor electronics can operate at temperatures over 600 C, which is significantly higher than the limit for Si-based semiconductor devices. SiC semiconductor chips were recently demonstrated to be operable at temperatures as high as 600 C, but only in the probe station environment because suitable packaging technology for sensors and electronics at temperatures of 500 C and beyond did not exist. Thus, packaging technology for SiC-based sensors and electronics is immediately needed for both application and commercialization of high-temperature SiC sensors and electronics. In response to this need, researchers at Glenn designed, fabricated, and assembled a prototype electronic package for high-temperature electronics, sensors, and microelectromechanical systems (MEMS) using aluminum nitride (AlN) substrate and gold (Au) thick-film materials. This prototype package successfully survived a soak test at 500 C in air for 500 hours. Packaging components tested included thick-film high-temperature metallization, internal wire bonds, external lead bonds, and a SiC diode chip die-attachment. Each test loop, which was composed of thick-film printed wire, wire bond, and lead bond was subjected to a 50-mA direct current for 250 hours at 500 C.

Chen, Liang-Yu↗

Thermal Switch for Satellite Temperature Control

An active radiator tile (ART) thermal valve has been fabricated using silicon micromachining. Intended for orbital satellite heat control applications, the operational principal of the ART is to control heat flow between two thermally isolated surfaces by bring the surfaces into intimate mechanical contact using electrostatic actuation. Prototype devices have been tested in a vacuum and demonstrate thermal actuation voltages as low as 40 volts, very good thermal insulation in the OFF state, and a large increase in radiative heat flow in the ON state. Thin, anodized aluminum was developed as a coating for high infrared emissivity and high solar reflectance.

Ziad, H.↗

Dynamic tunability of phase-change material transition temperatures using ions for thermal energy storage

Thermal energy storage (TES) based on phase-change materials (PCMs) has many current and potential applications, such as climate control in buildings, thermal management for batteries and electronics, thermal textiles, and transportation of pharmaceuticals. Despite its promise, the adoption of TES has been limited, in part due to limited tunability of the transition temperature, which hinders TES performance for varying use temperatures. Transition temperature tuning of a material using an external stimulus, such as pressure or an electric field, typically requires very large stimuli. To circumvent this problem, here, we report on the dynamic transition temperature tunability of a PCM using ions. We achieve a transition temperature tunability up to 6°C in polyethylene glycol (PEG) by using the salt lithium oxalatodifluoroborate at a low voltage of 2.5 V, which may enable simpler and safer devices/system designs. We also explain the thermal properties of the salt/PCM solution using the Flory-Huggins theory.

25 ENERGY STORAGE↗