Search NASA⌕ Search

SEARCH · Search NASA

Results for “test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Infrastructure improvements in the National Reactor Innovation Center Virtual Test Bed

The National Reactor Innovation Center’s (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. The VTB is being developed in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished via three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: • A documentation website detailing the models: https://mooseframework.inl.gov/virtual_test_bed • A GitHub repository that hosts the corresponding files: https://github.com/idaholab/virtual_test_bed. This paper presents the infrastructure added to the VTB in the last two fiscal years. Additional information about the VTB can be found in various publications [1, 2, 3, 4, 5, 6, 7, 8].

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of New Models Hosted on the Virtual Test Bed (VTB) in 2024

The National Reactor Innovation Center (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. It is in development in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished by three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: 1. A documentation website detailing the models (https://mooseframework.inl.gov/virtual_test_bed). 2. A GitHub repository that hosts the corresponding files (https://github.com/idaholab/virtual_test_bed). Previous documentation on the models hosted in the VTB can be found in [1,2,3,4]. These references also include additional background information on the various NEAMS codes showcased in the VTB (which is omitted here for brevity). This paper primarily provides a status update of the most recent additions to the repository.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary report on the mechanical testing performed at INL for creep rupture, fatigue, creep-fatigue, and aging of A709 base material

The report provides the status of the creep, fatigue, and creep-fatigue testing to conducted at Idaho National Laboratory to generate a data package to support Alloy 709 qualification in American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Division 5. These tests were performed on three commercial heats of plate material. The first procured heat was manufactured by G.O. Carlson with heat number 58776. Second and third heats were fabricated by ATI Specialty Rolled Products, with heat numbers 529900 and 530843, respectively. A series of creep and cyclic specimens were fabricated from these three heats, and tests were performed. This report presents a master list of all completed and ongoing creep, fatigue, and creep fatigue tests. Cyclic properties of three commercial heats are compared. Thermal aging of three commercial heats for 3000 hours were completed in FY 2025. The thermal aging campaign to age plate material from three commercial heats up to 100,000 hours is ongoing.

36 - MATERIALS SCIENCE↗

Design of Mini-Plate-1 Irradiation Test for Qualification of High-Density, Low-Enriched U-10Mo Monolithic Fuel

The United States High Performance Research Reactor project is tasked with fuel development and qualification leading to conversion of higher power research and test reactors in the US from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuels. Here, this manuscript identifies the functional and operational design requirements of the first miniature test plate (mini-plate [MP]) irradiation campaign (MP-1) of commercially fabricated LEU U-10Mo monolithic plate-type fuel and is the precursor to a large parametric mini-plate test (MP-2) aimed at producing the data to support regulatory qualification of the LEU U-10Mo monolithic fuel. The manuscript (1) provides a general description of the selected U-10Mo LEU fuel and (2) defines the overall experiment design and functional requirements to accomplish the specific test objective of MP-1, which is to confirm that the commercially manufactured LEU U-10Mo monolithic fuel meets the established requirements of geometric stability, mechanical integrity and stable and predictable behavior. The fuel testing parameters are established by the need to bound performance behavior within the operational envelope of the reactors being converted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UR 2 : Ultra-rapid reactivity test for real-time, low-cost quality control of calcined clays

To reduce cement's carbon footprint, there is growing interest in commercial adoption of sustainable SCMs such as calcined clays. However, the existing ASTM standard (R 3 test, C1897) to test the reactivity of such clays takes up to 7 days and cannot be used for real-time quality control in an industrial setting. We address this issue by introducing a 5-min Ultra-Rapid Reactivity (UR 2 ) test. By dissolving 47 clay specimens in 4 M NaOH solutions at 90°C, we report that a dissolution index of 1.54Al + Si correlates strongly to the 7-day R 3 heat (R 2 = 0.92, RMSE = 94.1 J/g). This dissolution index also correlates to the 28-day compressive strength for 14 clay mixtures (R 2 = 0.94, RMSE = 1.7 MPa). This UR 2 test relies on colorimetry and can be conducted via off-the-shelf, low-cost cameras. Overall, our new UR 2 test opens a pathway for real-time, low-cost quality control of calcined clays.

36 MATERIALS SCIENCE↗

Application of pH-dependent environmental protection agency test method 1313 to low-activity nuclear waste glass

Here, in this study, we present results of a room temperature, pH-dependent leach test established by United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework (LEAF) (EPA Method 1313 and further abbreviated EPA 1313) to study the alteration behavior of low-activity nuclear waste (LAW) glasses. Implementation of EPA 1313, which is closer to LAW disposal temperatures, could allow for more flexibility in the formulation of Hanford LAW glasses, specifically in terms of increased waste loading. A set of 48 LAW glasses were selected to test with EPA 1313. Briefly, the test method consists of adding glass to a number of solutions at different initial pH values and at a fixed mass-to-solution-volume ratio. The glass is then allowed to corrode for two days and the final solution pH and concentration of different glass elements in solution is measured. The test was modified from the published procedure to constrain particle size to provide more reproducible results, reduce the studied pH range to a more applicable range, and to reduce solution volume to reduce costs associated with material preparation. Compositional modeling was used to predict the measured elemental releases at various pH. The model predictions improved in tests where there was a relatively small difference between initial and final solution pH indicating that pH controls would result in better predictive models.

Accelerated aging↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Discrepant wear behavior of carbon nanotubes (CNTs) and dispersant in four-ball unidirectional and ball-on-flat reciprocating sliding tests

Carbon nanotubes (CNTs), basically rolled graphene sheets, have been studied lately as oil additives in the literature. However, we observed discrepant impact of CNTs on wear protection from two common tribological tests, four-ball unidirectional sliding and high frequency reciprocating rig (HFRR) ball-on-flat reciprocating sliding. To gain a stable suspension and dispersion of the CNTs in the oil, the CNT surface was functionalized with a phenyl ligand and a dispersant, polyisobutylene succinimide (PIBSI), was added. In the four-ball test, PIBSI alone failed to protect the surface but the CNTs effectively reduced the wear loss. The observations in the HFRR test however were the opposite: the PIBSI alone provided strong wear reduction but the CNTs had no positive impact. Here, such a discrepancy was hypothetically attributed to the different wear protection mechanisms by the PIBSI and CNTs which responded distinctively under different testing conditions. Additional unidirectional and reciprocating sliding tests with matching Hertzian contact pressures were able to validate the hypothesis. Worn surface morphological examination and tribofilm chemical analysis further supported the proposed wear mechanisms. Fundamental understanding gained in this study provides insights into the potential benefits and limitations of using CNTs in lubrication.

36 MATERIALS SCIENCE↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

FTTN: Feature-Targeted Testing for Numerical Properties of NVIDIA & AMD Matrix Accelerators

While NVIDIA has been the dominant provider of GPUs for HPC and ML, now AMD has several offerings of GPUs. This encourages programmers to try out AMD GPUs for new codes and also port existing codes over. Unfortunately, without understanding the floating-point differences between these GPU types, software development or porting can introduce bugs—and currently such an understanding is lacking. The magnitude of this open question becomes clear if one imagines the the number of floating-point precision choices (FP16, FP32, etc.), floating-point formats (standard floats, brain-float, etc.), and execution units available (elementary units, matrix/tensor cores, etc.) Questions such as rounding modes and subnormal support are also important. Most of these answers are unknown today or are hard to access. We provide the first testing-guided approach that answers a significant number of these questions. We also devise tests to reveal internal information (e.g., extra bits kept) to make sure that our findings are reliable. Many of our tests employ systematically generated random-programs, others apply fast-math flags and some involve fused multiplyadd. Especially for tensor/matrix cores, the tests have nontrivial logic that we present Our testing approach is reusable for the plethora of GPUs yet to be introduced. Our findings include up to 7 ulps of difference between NVIDIA and AMD for sin and cos at FP32 precision and 3 ulp at FP64. In our study of matrix cores (NVIDIA) and tensor cores (AMD), we have extensively characterized rounding modes (truncation versus round-to-nearest), the number of extra internal bits kept (whether 3 bits are kept or not), subnormal support for inputs and outputs across four different floating-point formats and across NVIDIA A100 and AMD MI250X GPUs. We believe that this wealth of data becoming available for the first time may help avoid significant porting bugs when migrating code across these platforms.

Li, Xinyi↗

OLCF Test Harness

Acceptance and regression testing of a High Performance Computing (HPC) system requires an automated and reproducible framework and tool for running and logging results. Manually running tests across a system is labor intensive and prone to reproducibility errors. The OLCF Test Harness (OTH) provides a framework in which to document required tests for a HPC system. The OTH then provides tools to execute and log results of these tests in an automated fashion.

Dietz, Dan [Oak Ridge National Laboratory (ORNL), ↗

Guideline 36 Conformance Test v2.0

ASHRAE Guideline 36 provides guidance for how typical commercial building HVAC systems should be controlled to reduce energy costs and improve the indoor environmental quality for occupants. An industry-led effort is developing test scripts for how control manufacturers can test that the control logic in their control products follows Guideline 36. This software intends to support that effort in two ways. First, by providing a testbed for control manufacturers to run the test scripts against their own control products and compare their generated results to the expected results provided by the test scripts. Second, by providing a testbed that can be used during the development of test scripts to rapidly and repeatably verify they exercise Guideline 36 logic as desired and generate accurate expected results that control products can be compared to. An initial version of the software has already been developed and released open-source by a previous CEC-funded project that implemented the first use case (https://github.com/LBNL-ETA/guideline36_conformance_test/blob/master/LICENSE.txt), while this software disclosure will add the functionality of the second use case, as well as update the software where needed, all open-source. We intend to extend and contribute to the existing open-source software repository.

Blum, David [Lawrence Berkeley National Laboratory↗

Downloadable Dynamometer Database (D3): Public Test Data on Advanced-Technology Vehicles

Access to high-quality, independent vehicle test data is critical to advancing energy-efficient transportation research. The Downloadable Dynamometer Database (D3) is a public repository of dynamometer test data on advanced-technology vehicles, generated at the Advanced Mobility Technology Laboratory (AMTL) at Argonne National Laboratory and hosted by the Transportation and Power Systems Division. The database has been made available to support researchers, students, and professionals engaged in energy-efficient vehicle research, development, and education. A wide range of vehicle categories has been tested (i.e., alternative fuel vehicles, conventional gasoline and diesel vehicles, all-electric vehicles, hybrid electric vehicles, and plug-in hybrid electric vehicles), as well as various drive cycles and test conditions documented in the accompanying D3 user presentation. Stakeholders can select a vehicle type, identify a vehicle of interest, and download the associated test data for use in their own analyses. Data downloaded from D3 must be accompanied by the required attribution: "This data is from the Downloadable Dynamometer Database and was generated at the Advanced Mobility Technology Laboratory (AMTL) at Argonne National Laboratory." These data are critical to vehicle modeling, validation, technology assessment, and educational use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica↗

Operational Experience of a Cryomodule Test Stand for LCLS-II Cryomodules

CMTS1 (cryomodule test stand 1) at Fermilab was built to test cryomodules built for the LCLS-II beamline at SLAC and is currently testing cryomodules for LCLS-II-HE, the high energy upgrade to LCLS-II. The first cryomodule test was in 2016 and to date over 30 cryomodules have been tested here. This talk will highlight operational experience of the vacuum systems including insulating, coupler, and a low particulate beamline vacuum system. It will focus on the problems that have come up over the years, their solutions, and mitigations put in place to prevent further issues.

43 PARTICLE ACCELERATORS↗

Data Based Shock Test Specification

It is vital that avionic packages used for testing and certifying the reliability and safety of U.S. nuclear weapons with platform aircraft survive exposure to shock environments during transportation and delivery. The objective of this research was to characterize the response to these transportation shock environments delivering accurate shock test specifications in order to set laboratory programming material and device certification rigor. Responses to shock events were analyzed in the frequency domain via the Shock Response Spectrum (SRS). Shocks were then grouped based on respective behavior of maximum response accelerations which were pseudorandomly resampled and compared to test data to form test specifications based on the MinerPalmgren hypothesis. In addition to discovering significant over testing in current shock specifications, a new systematic, data-driven approach to designing shock specifications was formulated.

42 ENGINEERING↗