Search NASA⌕ Search

SEARCH · Search NASA

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Test techniques for evaluation of indirect effects

Test techniques for evaluation of how well electrical and electronic equipment withstands the indirect effects of lightning were studied. The existing test techniques, and the philosophy behind some of the existing or evolving standards are discussed. Possible avenues of improvement in test techniques are suggested.

Franklin A Fisher↗

Some effects of experimental error in fracture testing

Effects of experimental imprecision on the stress intensity factors calculated for various practical specimen types are shown. A general form equation for the stress intensity factor is presented and a general error equation is derived. The expected error in the stress intensity factor is given in terms of the precision levels of the basic experimental measurements and derivatives of the stress intensity calibration factor. Nine common fracture specimen types are considered, and the sensitivity of the various types to experimental error is illustrated. Some implications for fracture toughness testing and crack growth rate testing are discussed and methods of analysis are proposed to compensate for the effects of experimental error.

Orange, T. W.↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Investigation of the Aerodynamic Characteristics of an 0.08-Scale Model of the Chance Vought XF7U-1 Airplane in the Langley High-Speed 7- by 10-Foot Tunnel. Part V - Wing-Alone Tests and Effect of Modifications to the Vertical Fins, Speed Brakes, and Fuselage TED No. NACA DE308: Wing-Alone Tests and Effect of Modifications to the Vertical Fins, Speed Brakes, and Fuselage, TED No. NACA DE308 - Part V

Tests have been conducted in the Langley high-speed 7- by 10-foot tunnel over a Mach number range from 0.40 to 0.91 to determine the stability and control characteristics of an 0.08-scale model of the Chance Vought XF7U-1 airplane. The wing-alone tests and the effect of the various vertical-fin modifications, speed-brake modifications, and fuselage modifications on the aerodynamic characteristics in pitch and yaw are presented in the present paper with a limited analysis of the results. Also included are tuft studies of the flow for some of the modifications tested.

Kuhri, Richard E.↗

RELAP5-3D Capabilities for High-Temperature Gas-Cooled Reactor Analysis

RELAP5-3D is the premier systems thermal-hydraulic code in the world. The code has been used significantly for high-temperature gas-cooled reactor (HTGR) analyses over the last 10 years, but there has not been a comprehensive summary of RELAP5-3D capabilities and methods for HTGR modeling. In this paper, we provide a guide for how novice users can build models for prismatic HTGRs. This guide includes best practices for developing heat structures and setting up radiation and conduction heat transfer. We also provide a summary of relevant validation studies. These studies are divided into three categories: separate effects tests, integral effects tests, and nuclear reactor studies. We present a comprehensive review of RELAP5-3D HTGR applications for reactor modeling over the last 10 years. These applications include work for the Modular High-Temperature Gas-Cooled Reactor benchmark, design activities for a prismatic HTGR as part of the U.S. Department of Energy’s Advanced Demonstration and Test Reactor Options Study, and studies performed to design gas-cooled microreactors. Following the comprehensive literature review, we present a gap analysis highlighting capabilities of RELAP5-3D that are available and missing for a complete analysis of HTGR thermal hydraulics. We also discuss the limitations of existing code capabilities and potential improvements that could improve analyses. Current research efforts have yet to fully validate RELAP5-3D for a prismatic HTGR analysis; however, some of this is attributable to confounding factors in the available experimental data as opposed to code capabilities. In conclusion, this paper presents the most comprehensive review to date on RELAP5-3D capabilities, limitations, and applications for HTGR analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Scaling for Nuclear Reactor System: Overview

A scaling analysis is essential for predicting the behavior of a reactor system under various operating conditions, as well as for ensuring safe and reliable experimentation and adequate dataset generation for supporting the system code model development and assessment in accordance with USNRC guidelines 1.203. Testing and modeling can be carried out at various scales, from small test units to full-scale reactors, to validate the predictions produced by the analysis. However, due to the cost and challenges associated with full-scale testing, the nuclear industry uses scaled test facilities—integral effect test (IET) and separate effect test (SET)—to identify potential design issues and optimize the design to ensure regulatory compliance for safer operation and anticipated accident management. In general, IET facilities are non-nuclear thermal hydraulics test facilities. In contrast, SET facilities can be non-nuclear testing (e.g., steam generator, containment, pump system SETs) and nuclear testing (mostly fuel-material irradiation testing). IETs are used to study the system-level thermal-hydraulic behavior of the reactor coolant system (RCS) under different anticipated operational occurrences (AOOs) and design basis accidents (DBAs) such as loss-of-coolant-accident (LOCA) and loss-of-power (i.e., station blackout) and loss-of-flow (i.e., failure of RCS pump). Several LOCA scenarios could happen in reactor DBAs, such as main steam line break (MSLB), SG tube rapture (SGTR), break in direct vessel injection (DVI), and other small breaks LOCA. Scaling analysis determines the appropriate size and operating conditions for the test facility. This involves analyzing the system's thermal-hydraulic behavior at different scales and identifying the key parameters that affect the thermal-hydraulic behavior of the reactor. These key parameters can be identified so that the scaled facility can replicate the expected conditions in a prototypical setting. The scaled facility can simulate the same flow rates, pressure gradients, heat transfer coefficients, and fluid properties as the prototype. Scaling analysis is used to ensure that the results from these tests can be scaled up to predict the behavior of a full-scale prototype with an acceptable range of scaling distortions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Test and Analysis Capabilities of the Space Environment Effects Team at Marshall Space Flight Center

Marshall Space Flight Center has developed world-class space environmental effects testing facilities to simulate the space environment. The combined environmental effects test system exposes temperature-controlled samples to simultaneous protons, high- and low-energy electrons, vacuum ultraviolet (VUV) radiation, and near-ultraviolet (NUV) radiation. Separate chambers for studying the effects of NUV and VUV at elevated temperatures are also available. The Atomic Oxygen Beam Facility exposes samples to atomic oxygen of 5 eV energy to simulate low-Earth orbit (LEO). The LEO space plasma simulators are used to study current collection to biased spacecraft surfaces, arcing from insulators and electrical conductivity of materials. Plasma propulsion techniques are analyzed using the Marshall magnetic mirror system. The micro light gas gun simulates micrometeoroid and space debris impacts. Candidate materials and hardware for spacecraft can be evaluated for durability in the space environment with a variety of analytical techniques. Mass, solar absorptance, infrared emittance, transmission, reflectance, bidirectional reflectance distribution function, and surface morphology characterization can be performed. The data from the space environmental effects testing facilities, combined with analytical results from flight experiments, enable the Environmental Effects Group to determine optimum materials for use on spacecraft.

Finckenor, M. M.↗

Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.

Airborne particles↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Propulsion Induced Effects (PIE) Test Program

The Propulsion Induced Effects (PIE) test program is being lead by NASA Ames for Configuration Aerodynamics (CA). Representatives from CA, Technology Integration (TI), Inlet, and the Nozzle ITD's are working with Ames in defining and executing this test program. The objective of the CA 4-14 milestone is to assess the propulsion/airframe integration characteristics of the Technology Concept Airplane (TCA) and design variations using computational and experimental methods. The experimental aspect includes static calibrations, transonic and supersonic wind tunnel testing. The test program will generate a comprehensive database that will include all appropriate wind tunnel corrections, with emphasis placed on establishing the propulsion induced effects on the flight performance of the TCA.

Cappuccio, Gelsomina↗

Proton Effects and Test Issues for Satellite Designers: Ionization Effects - Section 4

This portion of the Short Course is divided into two segments to separately address the two major proton-related effects confronting satellite designers: ionization effects and displacement damage effects. While both of these topics are deeply rooted in "traditional" descriptions of space radiation effects, there are several factors at play to cause renewed concern for satellite systems being designed today. For example, emphasis on Commercial Off-The-Shelf (COTS) technologies in both commercial and government systems increases both Total Ionizing Dose (TID) and Single Event Effect (SEE) concerns. Scaling trends exacerbate the problems, especially with regard to SEEs where protons can dominate soft error rates and even cause destructive failure. In addition, proton-induced displacement damage at fluences encountered in natural space environments can cause degradation in modern bipolar circuitry as well as in many emerging electronic and opto-electronic technologies. A crude, but nevertheless telling, indication of the level of concern for proton effects follows from surveying the themes treated in papers presented at this conference. The table lists themes found in the IEEE Transaction on Nuclear Science (TNS) December issue from the past year and compares them with the December issue's content a decade earlier. Ten years ago there were nine papers, or about 10% of the total, dealing with the four indicated topics. At that time, single event effects from protons were the primary concern, and these were thought to be possible only when a nuclear reaction initiated energetic recoil atoms. This is shown in the table as the 'traditional" SEE subject. A decade later, submissions addressing this topic had doubled, while papers devoted to displacement damage studies had increased from one to nine! More importantly, displacement damage effects in the natural space environments have become a concern for degradation in modern devices (other than solar cells), and this was not so ten years earlier.

Marshall, Paul W.↗

Proton Effects and Test Issues for Satellite Designers: Displacement Effects - Section 4

Microelectronic and photonic systems in the natural space environment are bombarded by a variety of charged particles including electrons, trapped protons, cosmic rays, and solar particles (protons and other heavy ions). These incident particles cause both ionizing and non-ionizing effects when traversing a device, and the effects can be either transient or permanent. The vast majority of the kinetic energy of an incident proton is lost to ionization, creating the single event effects (SEES) and total ionizing dose (TID) effects described in section IVA. However, the small portion of energy lost in non-ionizing processes causes atoms to be removed from their lattice sites and form permanent electrically active defects in semiconductor materials. These defects, i.e., "displacement damage," can significantly degrade device performance. In general, most of the displacement damage effects in the natural space environment can be attributed to protons since they are plentiful and extremely energetic (and therefore not readily shielded against). For this reason, we consider only proton induced displacement damage in this course. (Nevertheless, we identify solar cells as an important example of a case where both electron and proton damage can be important since only very light shielding is feasible.) The interested reader is encouraged to explore the three previous NSREC and RADECS short courses [Srou88a, Summ92, Hopk97] which also treat displacement damage issues for satellite applications. Part A of this segment of the short course introduces the space environment, proton shielding issues, and requirements specifications for proton-rich environments. In order to exercise the displacement damage analysis tools for on-orbit performance predictions, the requirements document must provide the relevant proton spectra in addition to the usual total ionizing dose-depth curves.

Marshall, Cheryl J.↗

1999 NSREC Short Course: Proton Effects and Test Issues for Satellite Designers: Displacement Effects

This portion of the Short Course is divided into two segments to separately address the two major proton-related effects confronting satellite designers: ionization effects and displacement damage effects. While both of these topics are deeply rooted in "traditional" descriptions of space radiation effects, there are several factors at play to cause renewed concern for satellite systems being designed today. For example, emphasis on Commercial Off-The-Shelf (COTS) technologies in both commercial and government systems increases both Total Ionizing Dose (TID) and Single Event Effect (SEE) concerns. Scaling trends exacerbate the problems, especially with regard to SEEs where protons can dominate soft error rates and even cause destructive failure. In addition, proton-induced displacement damage at fluences encountered in natural space environments can cause degradation in modern bipolar circuitry as well as in many emerging electronic and opto-electronic technologies.

Marshall, Cheryl J.↗

Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separate effects irradiation testing of miniature fuel specimens

We report that qualification of new nuclear fuels is necessary for their deployment and requires a thorough understanding of fuel behavior under irradiation. Traditionally, nuclear fuels have been qualified by performing exhaustive integral tests under a limited range of prototypic conditions designed for their specific reactor application. While some integral fuel testing is essential, basic data on behavior and property evolution under irradiation can be obtained from separate effects tests. These irradiations could offer reduced cost, reduced complexity, and in the case of accelerated testing, reduced time to achieve a given burnup. Furthermore, it may be desirable to design test irradiations capable of deconvoluting the myriad effects of burnup, temperature gradients, and other factors inherent to integral irradiation tests. Oak Ridge National Laboratory has developed an experimental capability to perform separate effects irradiation testing of miniature fuel specimens in the High Flux Isotope Reactor (HFIR): the “MiniFuel” irradiation vehicle. The small size (<4 mm 3 ) of the fuel specimens simplifies the design, analysis, and post-irradiation examination. By reducing the fuel mass, the total heat generated inside the experiment vehicle can be dominated by gamma heating in the structural materials instead of fission heating in the fuel. This essentially decouples the fuel temperature from the fission rate, allowing for highly accelerated testing (3X-18X the burnup rate of a typical light water reactor for 235 U enrichments varying from 0.22 wt% to 8 wt%) and an extremely flexible experiment design that can accommodate a wide range of fuel temperatures (~100 °C to >1200 °C), compositions, enrichments, and even geometries without requiring detailed analyses for each fuel variant. In conclusion, this paper summarizes the experiment design concept, evaluates potential applications for specific fuel forms, and briefly describes the first set of experiments on uranium nitride kernels that have been assembled and are currently being irradiated in the HFIR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

V/STOL and STOL ground effects and testing techniques

The ground effects associated with V/STOL operation were examined and an effort was made to develop the equipment and testing techniques needed for that understanding. Primary emphasis was on future experimental programs in the 40 x 80 and the 80 x 120 foot test sections and in the outdoor static test stand associated with these facilities. The commonly used experimental techniques are reviewed and data obtained by various techniques are compared with each other and with available estimating methods. These reviews and comparisons provide insight into the limitations of past studies and the testing techniques used and identify areas where additional work is needed. The understanding of the flow mechanics involved in hovering and in transition in and out of ground effect is discussed. The basic flow fields associated with hovering, transition and STOL operation of jet powered V/STOL aircraft are depicted.

Kuhn, R. E.↗