NREL - FY09 Lab Call: Supporting Research and Testing for MHK [Slides]
Presentation from the 2011 Water Peer Review in which the principal investigator discusses NREL's MHK portfolio.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presentation from the 2011 Water Peer Review in which the principal investigator discusses NREL's MHK portfolio.
The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) planned to demolish two buildings at the Area 1 Subdock at the Nevada National Security Site (NNSS) in Nye County, Nevada, to meet environmental management mission requirements. A review was conducted under Title 54 United States Code (USC) § 306101 (commonly known as Section 106 of the National Historic Preservation Act) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. As a result, a Memorandum of Agreement (MOA) was developed to mitigate the effects of the building demolitions. Stipulation III.B of the MOA requires an architectural survey of the Area 1 Subdock. Prior to this survey, the Subdock had not been systematically recorded. Therefore, an area of approximately 33 hectares (81 acres) was surveyed for historic properties by Desert Research Institute personnel. This effort resulted in the identification, recording, and evaluation of the potential Area 1 Subdock Historic District (SHPO Resource No. D377), including the identification of its contributing components. This district is recommended as eligible for the National Register of Historic Places (NRHP) under Criteria A and C. It contains 14 primary resources which include individual buildings, structures, storage yards, and infrastructure. Of these resources, all except one are recommended as elements that contribute to the district during its period of significance corresponding to nuclear testing from 1985 through 1992. Four of the resources (B18847, B18848, S2772, S2773) are recommended as individually eligible for the NRHP.
In this task, we focused on developing corrosion-resistant claddings for wave energy applications. Wave energy systems are exposed to saline conditions, which are corrosive to many metallic structural materials (e.g., carbon steel). Corrosion-resistant (stainless) steels are typically alloyed with >18% chromium (Cr) and >8% nickel (Ni), which dramatically raises material costs and can hinder the development of wave energy systems; thus, coatings are a necessary corrosion protection method for most. Non-metallic coatings (paint, epoxy) have shorter service lives, limited resistance to mechanical stress and wear, plus additional costs of inspection and eventual replacement. Therefore, overlay stainless steel (SS) claddings have a cost-effective use case for protecting components from corrosion, particularly for those that may be subject to mechanical stress / wear and with long service lives.
N/A
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
The Global Efficiency Medal competition, a cornerstone activity of the Super-efficient Equipment and Appliance Deployment (SEAD) Initiative, is an awards program that encourages the production and sale of super-efficient products. SEAD is a voluntary multinational government collaboration of the Clean Energy Ministerial (CEM). This winner-takes-all competition recognizes products with the best energy efficiency, guides early adopter purchasers towards the most efficient product choices and demonstrates the levels of energy efficiency achievable by commercially available and emerging technologies. The first Global Efficiency Medals were awarded to the most energy-efficient flat panel televisions; an iconic consumer purchase. SEAD Global Efficiency Medals were awarded to televisions that have proven to be substantially more energy efficient than comparable models available at the time of the competition (applications closed in the end of May 2012). The award-winning TVs consume between 33 to 44 percent less energy per 2 unit of screen area than comparable LED-backlit LCD televisions sold in each regional market and 50 to 60 percent less energy than CCFL-backlit LCD TVs. Prior to the launch of this competition, SEAD conducted an unprecedented international round-robin test (RRT) to qualify TV test laboratories to support verification testing for SEAD awards. The RRT resulted in increased test laboratory capacity and expertise around the world and ensured that the test results from participating regional test laboratories could be compared in a fair and transparent fashion. This paper highlights a range of benefits resulting from this first SEAD awards competition and encourages further investigation of the awards concept as a means to promote energy efficiency in other equipment types.
The development of Accident Tolerant Fuels (ATF) has expanded into a considerable research program in the wake of the events at the Japanese Fukushima Daiichi nuclear power plant in 2011. The ATF goal is to insert a test assembly into a commercial reactor by 2022. To support this, testing of the ATF design under off-normal conditions is needed to assess the 'enhanced accident tolerance' capability of the fuel rod design over standard UO{sub 2}-Zircaloy concepts. Transient testing capabilities are necessary for off-normal testing of events such as loss of coolant accidents (LOCA) and reactivity insertion accidents (RIA). A transient testing program has been developed to support the testing of ATF designs. The Transient Reactor Test (TREAT) facility has been chosen as the site to perform the transient testing of the ATF designs. TREAT is a versatile test facility capable of subjecting fuel specimens to various off-normal conditions. Historic TREAT experiments were performed in a variety of experimental test vehicles including static environment capsules, once-through flowing systems, and also recirculating flowing systems. The planned TREAT experiments will be operated under PWR conditions. Therefore, a static capsule vehicle is under development to handle required temperatures and pressures. The static capsule, termed the Static Environment Rodlet Transient Test Apparatus (SERTTA), will be used for irradiation tests in TREAT to subject ATF fuel rodlets to a range of power pulse conditions and environments. To aid in the design and analysis of future tests in TREAT, the fuel performance code BISON is being used. Fuel performance codes capable of accident modeling have been developed for some time and they have shown an ability to reproduce experimental results with some degree of adequacy, but they still require extensive verification and validation. Future experiments in TREAT will add to a limited database of past transient tests performed in transient reactors to support LWR systems. These tests can be used for future verification and validation of fuel performance codes. Understanding the impact of the uncertainty of influential parameters is critical for not only analyzing the results of the experiment but also for modeling and validation of codes. For example, uncertainties associated with the initial manufactured state of the sample, instrument measurements, material property models, and planned experiment conditions can provide important insight into model performance, experimental data, and play an important role in experimental design. The objective of this work is to perform an uncertainty and sensitivity analysis on a simplified RIA case of a standard UO{sub 2}-Zircaloy sample using expected nominal conditions in the SERTTA capsule in TREAT. The BISON fuel performance code is used in conjunction with DAKOTA (Design Analysis Kit for Optimization and Tera-scale Applications) to perform the uncertainty and sensitivity analysis. (authors)
This report documents results from a variety of activities requested by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The activities related to caustic leaching, oxidative leaching, permeate precipitation behavior of waste as well as chromium (Cr) leaching are: • Model Input Boehmite Leaching Tests • Pretreatment Engineering Platform (PEP) Support Leaching Tests • PEP Parallel Leaching Tests • Precipitation Study Results • Cr Caustic and Oxidative Leaching Tests. Leaching test activities using the PEP simulant provided input to a boehmite dissolution model and determined the effect of temperature on mass loss during caustic leaching, the reaction rate constant for the boehmite dissolution, and the effect of aeration in enhancing the chromium dissolution during caustic leaching. Other tests were performed in parallel with the PEP tests to support the development of scaling factors for caustic and oxidative leaching. Another study determined if precipitate formed in the wash solution after the caustic leach in the PEP. Finally, the leaching characteristics of different chromium compounds under different conditions were examined to determine the best one to use in further testing.
This report documents the operations, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) and its supporting infrastructure during FY2024. The METL facility had a very successful seventh year of operations while supporting the testing of multiple test article experiments in the facility. The METL facility continued supporting the Gear Test Assembly (GTA) testing and the Thermal Hydraulic Experimental Test Article (THETA) with the full testing with both the primary and secondary systems. Work to accommodate two additional experiments, a flow sensor test article (F-STAr) gripper test and a fuel handling gripper test article (GrTA) continued as they are expected to undergo testing in METL in FY2025. In addition, a new 18” test article, the Sample Testing Basket (STB) was used a few times to provide screening tests for sodium service materials. A fifth test vessel was installed in the location of Test Vessel 6, and a wet vapor nitrogen sodium processing system was developed and initially tested.
This testing will support NEAMS SafeSep Modeling efforts related to droplet simulation in liquid-liquid extraction equipment. Physical characteristic determinations will be completed for the fluids being used in the experiment including viscosity, density, surface tension, distribution coefficients, and diffusion coefficients. Then, experiments will be carried out to provide data for comparison to the simulation’s calculation of mass transfer coefficients. Experiments will be conducted with solutions used in the TRansUranic EXtraction (TRUEX) process extraction section. The TRUEX process was chosen since it is one solvent extraction system currently proposed for the separation of actinides and lanthanides from used nuclear fuel, it is diffusion limited, testing can be performed using non radioactive lanthanides to evaluate mass transfer. The extraction section involves transfer of one or more lanthanide species from an aqueous solution to an organic solvent. Single droplets rising by buoyancy will be studied first. Droplet size and number of species transferred will be varied independently to provide mass transfer coefficients as a function of each variable. An apparatus has been designed specifically for these experiments. In order to get more accurate measurements of droplet size, contact time, time of droplet formation, and possibly droplet breakup and coalescence, a high speed camera will be utilized for these experiments. Other potential experiments include examining the effects of jetted droplets and shear flow on the mass transfer coefficients.
Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.
Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems of advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinney pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.
This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.
This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. Creep tests were performed in air on the lever-arm load frames in the Mechanical and Environmental Testing Laboratory at Argonne National Laboratory (ANL). In FY21, the focus was on the age-hardened ESR-1150°C material. Twenty two tests were initiated, among which ten were completed. This report presents the data from the completed tests. Metallographic characterization of the fractured specimens were performed and the results are included. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed the effect of test temperature and stress on the deformation microstructure.