Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Pavilion 2 Feature Additions [Slides]

Pavilion 2 is a critical component of system testing for LANL HPC systems. Pavilion 2 is system independent, which allows for the creation of a large suite of generalized tests than can be applied to multiple systems. These additions to Pavilion 2 improve our ability to test systems and diagnose issues. With such a large suite, running the proper tests when diagnosing and fixing a system can be difficult, as well as locating old tests for reference. Test configurations may contain several permutations of a test, not all of which may apply to a given system. The ability to run sets of test permutations lets the tester focus on specific parts of the test without having to edit the test configurations or run extraneous tests. The addition of the filter argument improves the ability to find test results based on test attributes, including past tests. Pavilion 2's system independence is largely based on various layers of configuration files. Configuration files for the host, test, and modes exist to allow generalized testing. The operating system configuration layer can provide helpful OS defaults to a test. Survey, a collection and reporting tool, can help us gauge the performance of a system as well as diagnose issues. The addition of a Survey mode in Pavilion 2 makes running tests with Survey very straightforward. The Survey results are combined with Pavilion 2's test results to make it easy to access.

97 MATHEMATICS AND COMPUTING↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

Filter Measurement System for Nuclear Material Storage Canisters. End of Year Report FY 2013

A test system has been developed at Los Alamos National Laboratory to measure the aerosol collection efficiency of filters in the lids of storage canisters for special nuclear materials. Two FTS (filter test system) devices have been constructed; one will be used in the LANL TA-55 facility with lids from canisters that have stored nuclear material. The other FTS device will be used in TA-3 at the Radiation Protection Division’s Aerosol Engineering Facility. The TA-3 system will have an expanded analytical capability, compared to the TA-55 system that will be used for operational performance testing. The LANL FTS is intended to be automatic in operation, with independent instrument checks for each system component. The FTS has been described in a complete P&ID (piping and instrumentation diagram) sketch, included in this report. The TA-3 FTS system is currently in a proof-of-concept status, and TA-55 FTS is a production-quality prototype. The LANL specification for (Hagan and SAVY) storage canisters requires the filter shall “capture greater than 99.97% of 0.45-micron mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter”. The percent penetration (PEN%) and pressure drop (DP) of fifteen (15) Hagan canister lids were measured by NFT Inc. (Golden, CO) over a period of time, starting in the year 2002. The Los Alamos FTS measured these quantities on June 21, 2013 and on Oct. 30, 2013. The LANL(6-21-2013) results did not statistically match the NFT Inc. data, and the LANL FTS system was re-evaluated, and the aerosol generator was replaced and the air flow measurement method was corrected. The subsequent LANL(10-30-2013) tests indicate that the PEN% results are statistically identical to the NFT Inc. results. The LANL(10-30-2013) pressure drop measurements are closer to the NFT Inc. data, but future work will be investigated. An operating procedure for the FTS (filter test system) was written, and future project milestones are on track for completion

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

NREL's advanced distribution management system (ADMS) research helps utilities meet customer expectations of reliability, power quality, renewable energy use, data security, and resilience to natural disasters and other threats.

Advanced Research on Integrated Energy Systems↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

Portable self-contained pressure testing manifold and associated methods

A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.

Milholland, Roger A.↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 560: Septic Systems, Nevada Test Site, Nevada, Revision 0 with ROTC 1

Corrective Action Unit 560 comprises seven corrective action sites (CASs): •03-51-01, Leach Pit •06-04-02, Septic Tank •06-05-03, Leach Pit •06-05-04, Leach Bed •06-59-03, Building CP-400 Septic System •06-59-04, Office Trailer Complex Sewage Pond •06-59-05, Control Point Septic System The purpose of this CADD/CR is to provide justification and documentation supporting the recommendation for closure of CAU 560 with no further corrective action. To achieve this, corrective action investigation (CAI) activities were performed from October 7, 2008, through February 24, 2010, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 560: Septic Systems, Nevada Test Site, Nevada, and Record of Technical Change No. 1. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: •Determine whether contaminants of concern (COCs) are present. •If COCs are present, determine their nature and extent. •Provide sufficient information and data to complete appropriate corrective actions. The CAU 560 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. The following contaminants were determined to be present at concentrations exceeding their corresponding FALs: •No contamination exceeding the FALs was identified at CASs 03-51-01, 06-04-02, and 06-59-04. •The soil at the base of the leach pit chamber at CAS 06-05-03 contains arsenic above the FAL of 23 milligrams per kilogram (mg/kg) and polychlorinated biphenyl (PCBs) above the FAL of 0.74 mg/kg, confined vertically from a depth of approximately 5 to 20 feet (ft) below ground surface. The contamination is confined laterally to the walls of the leach pit chamber and leach rock. The contamination present at CAS 06-05-03 within the leach pit was not feasible to remove. •The surface and subsurface soils within and surrounding the septic system at CAS 06-05-04 contained PCB concentrations above the FAL of 0.74 mg/kg. The lateral and vertical extent of COCs was determined for this CAS. Contaminated soils were removed up to within 18 ft of the building. The remaining contamination is confined to subsurface soils adjacent to and beneath Building CP-162 and was not feasible to remove. •The solid materials within the septic tank and soils immediately surrounding the inlet end of the tank at CAS 06-59-03 contained benzo(a)pyrene above the FAL of 0.21 mg/kg. The soils, tank contents, and tank were removed. Materials remaining at this CAS do not contain contamination exceeding FALs. •The solids contained within the septic tank and inlet pipe at CAS 06-59-05 contained the following contaminants above their respective FALs: PCBs, arsenic, lead, benzo(a)pyrene, and pesticides. The tank and inlet pipe contents were removed. Materials remaining at this CAS do not contain contamination exceeding FALs. Therefore, the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) provides the following corrective action recommendations: •No further action for CASs 03-51-01, 06-04-02, and 06-59-04, as no contaminants of potential concern were present that exceed FALs. •Closure in place for CAS 06-05-03 under a corrective action with a use restriction (UR) for remaining PCB- and arsenic-impacted potential source material (PSM). The UR form and map have been filed in the NNSA/NSO Facility Information Management System, the FFACO database, and NNSA/NSO CAU/CAS files. •Closure in place for CAS 06-05-04 under a corrective action with a UR for remaining PCBs in soil adjacent to and beneath Building CP-162. The UR form and map have been filed in the NNSA/NSO Facility Information Management System, the FFACO database, and NNSA/NSO CAU/CAS files. •No further action for CAS 06-59-03, as the COC of benzo(a)pyrene in soil and PSM have been removed. •No further action for CAS 06-59-05, as the COCs in PSM within the septic tank and inlet piping have been removed and the tank was filled with concrete.

54 ENVIRONMENTAL SCIENCES↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

A JSON to CMake tool

As part of the conversion of the MCNP®testing system to CTest, a tool was needed to generate CMake variables from JSON formatted data structure. The system was first implemented using the JSON to CMake parser which with some slight modifications provided data useful for the MCNP CTest testing system. Upon further evaluation, we found it to be slow when setting up the 1600 tests during the CMake configuration step. Not only was it slow, it did not validate the JSON files during configuration allowing for unexpected behavior. Upon some web searching we came across a simple recursive python example that would provide the same capability needed by our testing system. This python example was effectively wrapped into a single python script that was used to convert the JSON data into CMake variables. This tool is attached as json_to_cmake.py and is listed in the appendix. In essence, the tool provides single variables for each value defined within the JSON file. The name for the variable is constructed by using the associated object names and array indicies needed to deference the variable itself. In the following sections, examples are provided to better describe how this is done.

97 MATHEMATICS AND COMPUTING↗

Evaluating Cell Temperature Models and the Effect of Wind Speed in PV System Capacity Testing: Preprint

Capacity testing is a routine procedure for assessing a photovoltaic system's performance relative to expectations. The most common test method involves fitting a regression model that predicts system output power using operating weather conditions including wind speed. Structural modifications to the regression model to incorporate wind in different ways improved the model's ability to fit measured system performance, but the observed improvements were small and unlikely to change the result of a capacity test. However, the results showed that the choice of reporting wind speed and inclusion or exclusion of wind speed in the performance model used as the test benchmark can significantly change the test result.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems

This is a final technical report for the project: Foam Fracturing Study for Stimulation Development of Enhanced Geothermal Systems (EGS). The goal is to demonstrate the feasibility of foam fracturing in EGS applications. The project, led by Oak Ridge National Laboratory (ORNL), was conducted in collaboration with Temple University. The report describes the research activities with Task 1 at ORNL: foam fracturing testing system development and experimental study on foam fracturing, and Task 2 at Temple University: foam testing and foam characterization. Main findings are: 1. A foam fracturing test system has been developed at ORNL, which can be used to perform foam fracturing under pressure up to 6,000 psi. The system monitors foam density during fracturing online and is capable of testing materials in both monotonic and cyclic (up to 50 Hz) injections. 2. Foam fracturing tests were carried out on Charcoal black granite specimens with a blind borehole to the middle length. Two diameters of blind borehole were tested; G2 series: 9.53 mm and G3 series: 4.76 mm. N2-in-water foam was used with AOS as a surfactant. 3. There was a hole-size effect on fracture initiation pressure. The effect is smaller in the case of foam, which was influenced by the high penetrability of gas in foam. Breakdown pressure showed a behavior just as that of fracture pressure; namely an increased value for small hole samples, while the effect in water fracture was more impressive than in foam fracture. 4. Water mass was reduced in foam fracturing within similar range of breakdown pressures. In G2 series, it was decreased from 10.44 g for water fracturing to 5.17 g, representing more than 50% water reduction. Therefore, there is the potential to reduce water use in EGS stimulation through foam fracturing. 5. Use of cyclic injection has the potential to reduce the breakdown pressure and seismicity in EGS application. Experiments using 4-s cycle period found that specimens can be fractured with a low number of cycles. The fatigue pressure was approximately 64 - 77% of monotonic breakdown pressure for water fracturing and 58 - 94% of the breakdown pressure for foam fracturing. 6. A foam stability testing system has been developed that can test foam at 220 Deg C to 2,000 psi. Tested components of candidate foams included two gases: N2 and CO2; 4 surfactants: AOS, SDS, NP-40 and CTAC; 5 stabilizing agents: guar, bentonite clay, borate salt, silica NPs, and GO. 7. N2 and AOS provided the most stable performance over the tested ranges. Furthermore, the AOS foam with stabilizing agents of guar and borate salt (crosslinker) offered the highest half-life of 20 minutes at 200 Deg C and 1,000 psi. 8. Arrhenius equation and modified power law have been demonstrated to fit well the half-time vs. temperature and pressure data, respectively. These relations can be useful to provide the suggestion for future foam stability study. This submission contains the supporting data developed during the project: 1) A final technical report 2) Granite fracturing data in monotonic and cyclic injections with water and N2 foam Foam performance data in various temperatures and pressures, including half-time, is submitted separately.

15 GEOTHERMAL ENERGY↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel in situ device based on a bionic piezoelectric actuator to study tensile and fatigue properties of bulk materials

In this work, a miniaturized device based on a bionic piezoelectric actuator was developed to investigate the static tensile and dynamic fatigue properties of bulk materials. The device mainly consists of a bionic stepping piezoelectric actuator based on wedge block clamping, a pair of grippers, and a set of precise signal test system. Tensile and fatigue examinations share a set of driving system and a set of signal test system. In situ tensile and fatigue examinations under scanning electron microscope or metallographic microscope could be carried out due to the miniaturized dimensions of the device. The structure and working principle of the device were discussed and the effects of output difference between two piezoelectric stacks on the device were theoretically analyzed. The tensile and fatigue examinations on ordinary copper were carried out using this device and its feasibility was verified through the comparison tests with a commercial tensile examination instrument.

36 MATERIALS SCIENCE↗