Search NASA⌕ Search

SEARCH · Search NASA

Results for “thin membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Scalable Graphene Oxide Hollow Fiber Membranes for Dye Desalination Enabled by Multi‐Purpose Polyamine Functionalization

2D nanosheets such as graphene oxide (GO) can be stacked to construct membranes with fine-tuned nanochannels to achieve molecular sieving ability. These membranes are often thin to achieve high water permeance, but their fabrication with consistent nanostructures on a large scale presents an enormous challenge. Herein, GO-based hollow fiber membranes (HFMs) are developed for dye desalination by synergistically combining chemical etching to form in-plane nanopores (10–30 nm) to increase water permeance and polyamine functionalization to improve underwater stability and enable facile large-scale production using existing membrane manufacturing processes. HFM modules with areas of 88 cm 2 and GO layer thicknesses of ≈500 nm are fabricated, and they exhibited a stable dye water permeance of 75 L m −2 h −1 bar −1 , rejection of >99.5% for Direct red and Congo red, and Na 2 SO 4 /dye separation factor of 300–500, superior to state-of-the-art commercial membranes. Furthermore, the versatility of this approach is also demonstrated using different short polyamines and porous substrates. This study reveals a scalable way of designing 2D materials into high-performance robust membranes for practical applications.

amine functionalization↗

New Hydrophilic, Composite Membranes for Air Removal from Water Coolant Systems

Liquid coolants are commonly used as thermal transport media to increase efficiency and flexibility in aerospace vehicle design. The introduction of gas bubbles into the coolant can have negative consequences, including: loss of centrifugal pump prime, irregular sensor readings, and blockage of coolant flow to remote systems. One solution to mitigate these problems is the development of a passive gas removal device, or gas trap, installed in the flight cooling system. In this study, a new hydrophilic, composite membrane has been developed for passage of the coolant fluid and retention of gas bubbles. The trapped bubbles are subsequently vented from the system by a thin, hydrophobic, microporous membrane. The original design for this work employed a homogeneous membrane that was susceptible to fouling and pore plugging. Spare gas traps of this variety have degraded during storage, and recreation of the membranes has been complicated due to problems with polymer duplication and property variations in the final membranes. In this work, replacements have been developed based on deposition of a hydrophilic polymer on the bore-side of a porous polyethylene (PE) tube. The tube provides excellent chemical and mechanical stability, and the hydrophilic layer provides retention of gas bubbles. Preliminary results have shown that intimate contact is required between the deposited layer and the substrate to overcome material differences. This has been accomplished by presoaking the membrane tube in the solvent to raise its surface energy. Polymer solutions of various concentrations have been used to promote penetration of the polymer layer into the porous substrate and to control separation layer thickness. The resulting composite membranes have shown repeatable decrease in nitrogen permeability, which is indicative of a decrease in membrane pore size. Studies with water permeation have yielded similar results. We have observed some swelling of the added polymer layer, which causes a slight decrease in membrane pore size, and should result in improved bubble retention. Preliminary studies have also been performed on gas retention in flowing systems. Initial results have been promising, with negligible gas permeation for the coated membranes compared to 100% gas permeation in the uncoated tube.

Ritchie, Stephen M. C.↗

The behavior of a liquid drop levitated and drastically flattened by an intense sound field

The deformation and break-up are studied of a liquid drop in levitation through the radiation pressure. Using high-speed photography ripples are observed on the central membrane of the drop, atomization of the membrane by emission of satellite drops from its unstable ripples, and shattering of the drop after upward buckling like an umbrella, or after horizontal expansion like a sheet. These effects are captured on video. The ripples are theorized to be capillary waves generated by the Faraday instability excited by the sound vibration. Atomization occurs whenever the membrane becomes so thin that the vibration is sufficiently intense. The vibration leads to a destabilizing Bernoulli correction in the static pressure. Buckling occurs when an existent equilibrium is unstable to a radial (i.e., tangential) motion of the membrane because of the Bernoulli effect. Besides, the radiation stress at the rim of the drop is a suction stress which can make equilibrium impossible, leading to the horizontal expansion and the subsequent break-up.

Lee, C. P.↗

Phase-Synchronized Modal Testing of Mirror Membrane

The research reports on the development of a whole-field, system-level interferometry technique having phase-synchronized data acquisition and adjustable phase triggering. The technique utilizes a Fizeau interferometer, arbitrary function generator, oscilloscope, trigger filter, and CCD camera to determine the out-of-plane modal frequencies of a thin, highly reflective membrane. The technique generates phase-adjustable CCD camera trigger signals that are synchronized to the audio frequency excitation signal. The surface figures from the resulting interferograms were evaluated with fringe-following software and compared against that of an ideal membrane vibrating at resonance.

Rogers, Ted↗

Nanofilm Composite Membranes of Bottlebrush Poly(1,3‐Dioxolane) Plasticized by Poly(Ethylene Glycol) for CO 2 /N 2 Separation

Abstract Poly(1,3‐dioxolane) has emerged as a leading membrane material for post‐combustion CO 2 capture due to its high ether oxygen content and strong affinity toward CO 2 . However, they are often cross‐linked to inhibit crystallization, which makes them impossible to fabricate into industrial thin‐film composite membranes. Herein, soluble and high molecular weight bottlebrush polymers ( b PDXLA) are synthesized using reversible addition‐fragmentation chain transfer polymerization and demonstrate the feasibility of fabricating nanofilm (≈100 nm) composite membranes (NCMs). Furthermore, b PDXLA can be plasticized using a miscible additive of poly(ethylene glycol) dimethyl ether (PEGDME) to improve CO 2 permeability while retaining good CO 2 /N 2 selectivity. For example, adding 20 mass% PEGDME improves CO 2 permeance from 930 to 1300 GPU and decreases CO 2 /N 2 selectivity from 74 to 53 at 25 °C; the membrane exhibits stable separation performance competitive with state‐of‐the‐art commercial membranes. This work unveils a practical approach to designing uncross‐linked, highly polar polymers for practical membrane gas separation and highlights a facile way to enhance performance by incorporating miscible plasticizers using industrial manufacturing processes.

Zhang, Gengyi [Department of Chemical and Biologic↗

Polymer-Derived Amorphous Aluminosilicate Nanomembranes for H 2 Purification

Aluminosilicate zeolite membranes with robust microporous crystalline structures are attractive for the molecular separation of H 2 from light gases, but their large-scale fabrication is complicated and costly, hindering their practical applications. Herein, we present polymer-derived amorphous aluminosilicate nanomembranes that combine the exceptional processability of polymers with the superior gas separation properties of aluminosilicates. Specifically, thin-film composite membranes comprising 150 nm polydimethylsiloxane were first treated with oxygen plasma to generate 10 nm polyorganosilica (POSi) on the surface, which were then subjected to few-cycle atomic layer deposition (ALD) using trimethylaluminum as a metal precursor and water vapor as a coreactant. This scalable two-step process yields few-nanometer amorphous aluminosilicates with strong size-sieving ability. For example, three-cycle ALD treatment of POSi increases H 2 /CO 2 selectivity from 39 to 200 and H 2 /CH 4 selectivity from 190 to 500, while decreasing H 2 permeance from 990 to 210 GPU at 150 °C, superior to the state-of-the-art membranes. In conclusion, rapid and scalable manufacturing of amorphous aluminosilicate nanolayers can also be of interest for catalysis and adsorption applications.

36 MATERIALS SCIENCE↗

Analytical and numerical investigation of structural response of compliant wall materials

Surface motion of compliant walls in drag reduction experiments was analyzed. The spectrum of surface motion indicates that membranes over deep cavities respond at low frequencies and large wavelengths. The membrane over a deep cavity is therefore found not to yield the desired reponse predicted by the postulated mechanism. The membrane over a thin air gap is found to act as a wavelength chopper, and analysis of the nonlinear response of the compliant surface indicates its possible suitability for compliant wall experiments. Periodic structures are found to lock in the desired wavelengths of motion. Laminated structures are found to be very ineffective as compliant models, except when there is no bonding between the membrane and the backing. Computer programs developed for these analyses are documented.

Goglia, G. L.↗

Analytical and numerical investigation of structural response of compliant wall materials, part 1

Surface motion of compliant walls in drag reduction experiments was analyzed. Critical comparison was made between the dynamic motion of the structure and the postulated mechanism of drag reduction. The spectrum of surface motion indicated that membranes over deep cavities respond at low frequencies and large wavelengths. The membrane over a deep cavity is therefore found not to yield the desired response predicted by the postulated mechanism. The membrane over a thin air gap is found to act as a wavelength chopper, and analysis of the nonlinear response of that compliant surface indicated its possible suitability for compliant wall experiments. Periodic structures are found to lock in the desired wavelengths of motion, and it was shown that at least in Kramer's initial experiments they produced high frequency surface motions. Laminated structures are found to be very ineffective as compliant models, except when there is no bonding between the membrane and the backing. Computer programs developed for these analyses are documented.

Balasubramanian, R.↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of micro-fabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. This paper will focus on description of the development of the instrument.

Wilcox, J. Z.↗

Structure and functions of simple membrane-water interfaces

The structure and functions of the earliest ancestors of contemporary cells are focal points in studies of the origin of life. Probably the first cell-like structures were vesicles - closed, spheroidal structures with aqueous medium trapped inside. The membranous walls of vesicles were most likely bilayers composed of simple amphiphilic material available on early earth. The membrane studied was composed of glycerol 1-monooleate (GMO). Glycerol forms the polar head group and the oily tail contains 18 carbon atoms. All head groups have been found to be located in two narrow regions at the interfaces with water. The membrane interior, formed by the hydrophobic tails, is quite fluid with chain disorder increasing towards the center of the bilayer. These results are in agreement with x-ray and neutron scattering data from related bilayers. The width of the membrane is not constant, but fluctuates in time and space. Occasional thinning defects in the membrane, observed during the course of the simulations, may have a significant influence on rates of passive transport of small molecules across membranes. It has been found that water penetrates the head group region but not the oily interior of the membrane. Water molecules near the interface are oriented by dipoles of the head groups. The resulting electrostatic potential across the interface, determined in our simulations, has been found to be markedly larger than across the water-oil interface. This quantity has been implicated as the source of selectivity, with respect to the sign of the charge, as an ion approaches the interface and during transport of hydrophobic ions across membranes.

Pohorille, A.↗

Atomically Fine-Tuning Organic–Inorganic Carbon Molecular Sieve Membranes for Hydrogen Production

Polymeric membranes with great processability are attractive for the H 2 /CO 2 separation required for hydrogen production from renewable biomass with carbon capture for utilization and sequestration. However, it remains elusive to engineer polymer architectures to obtain desired sub-3.3 Å ultramicropores to efficiently sieve H 2 from CO 2 . Herein, we demonstrate a scalable way of carbonizing polybenzimidazole (PBI) at low temperatures, followed by vapor phase infiltration (VPI) to atomically narrow ultramicropores throughout the films, forming hybrid organic–inorganic carbon molecular sieves (CMSs). One VPI cycle (100 s) for the PBI carbonized at 500 °C remarkably increases H 2 /CO 2 selectivity from 9.6 to 83 at 100 °C, surpassing Robeson’s upper bound. The CMS demonstrates a stable H 2 /CO 2 separation performance when challenged with simulated syngas streams and can be fabricated into thin-film composite membranes, outperforming state-of-the-art membranes. Finally, the scalable approach can be ubiquitous to molecularly fine-tune ultramicropores of leading polymeric membranes to further improve their size-sieving ability and thus separation efficiency.

36 MATERIALS SCIENCE↗

MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

Lakew, B.↗

Casting Of Multilayer Ceramic Tapes

Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

Collins, Earl R., Jr.↗

A Low-noise Micromachined Millimeter-Wave Heterodyne Mixer using Nb Superconducting Tunnel Junctions

A heterodyne mixer with a micromachined horn antenna and a superconductor-insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30 +/- 3 K (without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.

DeLange, Gert↗

Micromachined Millimeter- and Submillimeter-Wave SIS Heterodyne Receivers for Remote Sensing

A heterodyne mixer with a micromachined horn antenna and a superconductor -insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30+/-3 K without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.

Hu, Qing↗

Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

Urgiles, E.↗

Strength and Fracture Toughness of Solid Oxide Fuel Cell Electrolyte Material Improved

Solid oxide fuel cells (SOFC) are being developed for various applications in the automobile, power-generation, and aeronautics industries. Recently, the NASA Glenn Research Center has been exploring the possibility of using SOFC's for aeropropulsion under its Zero Carbon Dioxide Emission Technology (ZCET) Program. 10-mol% yttriastabilized zirconia (10YSZ) is a very good anionic conductor at high temperatures and is, therefore, used as an oxygen solid electrolyte in SOFC. However, it has a high thermal expansion coefficient, low thermal shock resistance, low fracture toughness, and poor mechanical strength. For aeronautic applications, the thin ceramic electrolyte membrane of the SOFC needs to be strong and tough. Therefore, we have been investigating the possibility of enhancing the strength and fracture toughness of the 10YSZ electrolyte without degrading its electrical conductivity to an appreciable extent. We recently demonstrated that the addition of alumina to zirconia electrolyte increases its strength as well as its fracture toughness. Zirconia-alumina composites containing 0 to 30 mol% of alumina were fabricated by hot pressing. The hot pressing procedure was developed and various hot pressing parameters were optimized, resulting in dense, crackfree panels of composite materials. Cubic zirconia and a-alumina were the only phases detected, indicating that there was no chemical reaction between the constituents during hot pressing at elevated temperatures. Flexure strength sf and fracture toughness K(sub IC) of the various zirconia-alumina composites were measured at room temperature as well as at 1000 C in air. Both properties showed systematic improvement with increased alumina addition at room temperature and at 1000 C. Use of these modified electrolytes with improved strength and fracture toughness should prolong the life and enhance the performance of SOFC in aeronautics and other applications.

Bansal, Narottam P.↗