Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Measurement of rabbit eardrum vibration through stroboscopic digital holography

In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without compromising on the quality. Results of a repeatability test will be presented as well. Since the method measures the membrane motion as a function of time in small time steps, we do not only measure vibration amplitude like in time-average holography, but we can also measure non-linear elastic and transient behaviour. In conclusion, the combination of good spatial, depth and time resolution with the fast data acquisition and very wide frequency range make our technique applicable in a number of fields, including biological tissue vibrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of pan-sharpening algorithm for correlative multimodal imaging using AFM-IR

The coupling of atomic force microscopy with infrared spectroscopy (AFM-IR) offers the unique capability to characterize the local chemical and physical makeup of a broad variety of materials with nanoscale resolution. However, in order to fully utilize the measurement capability of AFM-IR, a three-dimensional dataset (2D map with a spectroscopic dimension) needs to be acquired, which is prohibitively time-consuming at the same spatial resolution of a regular AFM scan. In this paper, we provide a new approach to process spectral AFM-IR data based on a multicomponent pan-sharpening algorithm. This approach requires only a low spatial resolution spectral and a limited number of high spatial resolution single wavenumber chemical maps to generate a high spatial resolution hyperspectral image, greatly reducing data acquisition time. As a result, we are able to generate high-resolution maps of component distribution, produce chemical maps at any wavenumber available in the spectral range, and perform correlative analysis of the physical and chemical properties of the samples. We highlight our approach via imaging of plant cell walls as a model system and showcase the interplay between mechanical stiffness of the sample and its chemical composition. We believe our pan-sharpening approach can be more generally applied to different material classes to enable deeper understanding of that structure-property relationship at the nanoscale.

36 MATERIALS SCIENCE↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗

Thermal infrared research: Where are we now?

The use of infrared temperatures in agriculture and hydrology is based on the energy balance equation which is used to estimate evapotranspiration and crop stress over small areas within a field as well as large areas. For its full utilization, this measurement must be combined with other spectral data collected at a time resolution sufficient to detect changes in the agricultural or hydrological systems and at a spatial resolution with enough detail to sample within individual fields. The most stringent requirement is that the data be readily available to the user. The spatial resolution necessary for IR measurements to be incorporated into evapotranspiration models to accurately estimate field and regional transpiration or measure crop stress; methods to estimate crop stress and yield over large areas and different cultivars within a species; the temporal resolution adequate for detecting crop stress or inclusion in evapotranspiration models; and ancillary parameters for estimating thermal IR measurements must be investigated.

Hatfield, J. L.↗

Dynamics explorer guest investigator

The use of Dynamics Explorer (DE) data sets to model the auroral inputs for the time dependent ionospheric model (TDIM) is reported. The modelling requires DE-1 SAI images and simultaneous DE-2 LAPI particle data. The data sets allow the large scale relative auroral variations and local absolute energy flexes and characteristics energies to be defined. The images enabled global scale auroral modelling with 12 min. time resolution and the LAPI data presented a detailed energy flux and characteristic energy calibration of the image model. The auroral model is used as an input to the TDIM and studies ionospheric storms.

Sojka, J. J.↗

Prestack Waveform Inversion at GC 955: Trials and sensitivity of PWI to high-resolution seismic data (Data Report)

Understanding the spatial extent and variability of hydrate deposits has important implications for potential economic production, climate change, and assessing natural hazards risks. Seismic reflection techniques are capable of determining the extent of gas hydrate deposits and can shed light on hydrate concentrations and properties. Using high resolution prestack time migrated seismic data collected during a 2013 US Geological Survey expedition and prestack waveform inversion (PWI) techniques, we produce highly resolved velocity models and compare them to co-located well logs. Coupling our PWI results with velocity-porosity relationships and nearby well control, we compare hydrate properties at site 955 in the Green Canyon and site 313 at Walker Ridge.

03 NATURAL GAS↗

MO-G-17A-01: Innovative High-Performance PET Imaging System for Preclinical Imaging and Translational Researches

Purpose: To develop a practical and compact preclinical PET with innovative technologies for substantially improved imaging performance required for the advanced imaging applications. Methods: Several key components of detector, readout electronics and data acquisition have been developed and evaluated for achieving leapfrogged imaging performance over a prototype animal PET we had developed. The new detector module consists of an 8×8 array of 1.5×1.5×30 mm{sup 3} LYSO scintillators with each end coupled to a latest 4×4 array of 3×3 mm{sup 2} Silicon Photomultipliers (with ∼0.2 mm insensitive gap between pixels) through a 2.0 mm thick transparent light spreader. Scintillator surface and reflector/coupling were designed and fabricated to reserve air-gap to achieve higher depth-of-interaction (DOI) resolution and other detector performance. Front-end readout electronics with upgraded 16-ch ASIC was newly developed and tested, so as the compact and high density FPGA based data acquisition and transfer system targeting 10M/s coincidence counting rate with low power consumption. The new detector module performance of energy, timing and DOI resolutions with the data acquisition system were evaluated. Initial Na-22 point source image was acquired with 2 rotating detectors to assess the system imaging capability. Results: No insensitive gaps at the detector edge and thus it is capable for tiling to a large-scale detector panel. All 64 crystals inside the detector were clearly separated from a flood-source image. Measured energy, timing, and DOI resolutions are around 17%, 2.7 ns and 1.96 mm (mean value). Point source image is acquired successfully without detector/electronics calibration and data correction. Conclusion: Newly developed advanced detector and readout electronics will be enable achieving targeted scalable and compact PET system in stationary configuration with >15% sensitivity, ∼1.3 mm uniform imaging resolution, and fast acquisition counting rate capability for substantially improved imaging and quantification performance for small animal imaging and image-guided radiotherapy applications. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration validation for the GEOS 3 altimeter

An absolute calibration of the altitude data is needed for some applications of the large quantity of altimeter data taken by the GEOS 3 intensive mode altimeter. The considered calibration technique is based on the use of a gravimetric geoid model and satellite passes which are nearly overhead at island laser tracking sites. Near overhead passes of GEOS 3 were achieved at Bermuda. Two of these passes were tracked by the Bermuda laser. The reported investigation has the objective to obtain a best estimate of the GEOS 3 altimeter calibration bias, using the two available passes and reconciling differences between them. Assuming that orbits with accurate altitudes over Bermuda are obtained, discrepancies between the two passes could be due to incorrect time tagging of the altimeter data. To assist in the resolution of the timing question, additional GEOS 3 passes through the calibration area were selected. On the basis of the obtained results, it is recommended to add 10.24 ms to GEOS 3 altimeter time tags before using the data.

Martin, C. F.↗

Two dimensional numerical simulations of carrier dynamics during time-resolved photoluminescence decays in two-photon microscopy measurements in semiconductors

We use two-dimensional numerical simulations to analyze high spatial resolution time-resolved spectroscopy data. This analysis is applied to two-photon excitation time-resolved photoluminescence (2PE-TRPL) but is broadly applicable to all microscopic time-resolved techniques. By solving time-dependent drift-diffusion equations, we gain insight into carrier dynamics and transport characteristics. Accurate understanding of measurement results establishes the limits and potential of the measurement and enhances its value as a characterization method. Diffusion of carriers outside of the collection volume can have a significant impact on the measured decay but can also provide an estimate of carrier mobility as well as lifetime. In addition to material parameters, the experimental conditions, such as spot size and injection level, can impact the measurement results. Although small spot size provides better resolution, it also increases the impact of diffusion on the decay; if the spot size is much smaller than the diffusion length, it impacts the entire decay. By reproducing experimental 2PE-TRPL decays, the simulations determine the bulk carrier lifetime from the data. The analysis is applied to single-crystal and heteroepitaxial CdTe, material important for solar cells, but it is also applicable to other semiconductors where carrier diffusion from the excitation volume could affect experimental measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The influence of velocity variability on the determination of wind profiles

High sensitivity radars allow the determination of velocity estimates at time resolutions down to one minute or better. Because of the variability introduced to the mean wind due to turbulence and waves, the high resolution profiles may not be too useful for forecasting applications, although they yield the most realistic estimate of the instantaneous wind profile. Profiles of wind speed and direction, vertical velocity and echo power, which were deduced in real-time on 23 August 1981 with the spaced antenna drift mode of the SOUSY-VHF-Radar are shown. Whereas these profiles were measured within 1 minute, the operating routine allowed the selection of variable (longer) measuring periods, and one has to search for the optimum duration of the data averaging period. A high time resolution wind vector diagram is given which gives an idea of the temporal variability. The data were obtained with the spaced antenna technique, which allows a good estimate of the horizontal wind without having to correct for the vertical velocity component. The wind vectors specifically indicate a quasi-periodic variation in direction. This is assumed to be due to gravity waves since the vertical velocity also shows periodical variations with the same period. The consistency of these spaced-antenna VHF radar results along with the radiosonde data convinced researchers that the method is quite suitable for wind profiling applications.

Rottger, J.↗

Full-waveform inversion and least-squares reverse-time migration imaging of collimated ultrasonic-beam data for high-resolution wellbore integrity monitoring

Los Alamos National Laboratory (LANL) has recently developed an ultrasonic side-lobe suppressed Bessel collimated beam transducer for low-frequency imaging through highly attenuating materials. In this paper, we study the effectiveness of using such a collimated ultrasonic-beam transducer for imaging concrete heterogeneities outside borehole casing for high-resolution borehole imaging and wellbore integrity monitoring. We obtain detailed concrete heterogeneities including a low-velocity zone using ultrasound data acquired with a 3D imaging prototype and our recently developed full-waveform inversion and least-squares reverse-time migration methods. Full-waveform inversion fits synthetic ultrasonic waveforms with recorded waveforms to build a high-resolution velocity model. Least-squares reverse-time migration produces a high-resolution structural image showing material discontinuities. Finally, our results demonstrate that LANL's 3D imaging system with a collimated ultrasonic-beam transducer together with full-waveform inversion and least-squares reverse-time migration imaging has great potential for high-resolution single-well borehole imaging and non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Fast 3D Surface Extraction

Ocean scientists searching for isosurfaces and/or thresholds of interest in high resolution 3D datasets required a tedious and time-consuming interactive exploration experience. PISTON research and development activities are enabling ocean scientists to rapidly and interactively explore isosurfaces and thresholds in their large data sets using a simple slider with real time calculation and visualization of these features. Ocean Scientists can now visualize more features in less time, helping them gain a better understanding of the high resolution data sets they work with on a daily basis. Isosurface timings (512 3 grid): VTK 7.7 s, Parallel VTK (48-core) 1.3 s, PISTON OpenMP (48-core) 0.2 s, PISTON CUDA (Quadro 6000) 0.1 s.

97 MATHEMATICS AND COMPUTING↗

Evaluating performance of two-group interfacial area transport equation for vertical small and large diameter pipes

In the two-fluid transport model, the coupling of mass, momentum and energy transfer between phases is highly dependent on interfacial area transfer terms. Several research efforts in the past have been focused on the development of an interfacial area transport equation model (IATE), in order to eliminate the drawbacks of static flow regime maps currently used in best-estimate thermal-hydraulic system codes. The IATE attempts to model the dynamics that are involved in two phase flows by accounting for the different interaction mechanisms affecting bubble transport in the flow. The further development and validation of IATE models has been hindered by the lack of adequate experimental data in regions beyond the bubbly flow regime. At the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) experiments utilizing wire mesh sensors have been performed over all flow regimes, establishing a database of high-resolution (in space and time) data. Two sets of data from small and large diameter pipes fitted with wire mesh sensors is utilized in this work. Analysis of flow conditions in the bubbly, churn turbulent and annular flow regimes is presented. The performance of the Fu-Ishii two-group model is evaluated against small diameter database. Results indicate good performance (< 10% error) for small group 1 bubbles, and poor performance for large group 2 bubbles. The Smith two-group large diameter IATE model is evaluated for the large diameter database. In low void-fraction regimes, the Smith model performs well. In high void-fraction regimes, there is poor group-wise interfacial area prediction - however the total interfacial area is erroneously predicted well as group-wise errors compensate each other. Overall, the study suggests that further efforts and re-evaluation of closure terms are needed in order to extend the range of validity of the IATE models. (authors)

42 ENGINEERING↗

Faraday rotation data analysis with least-squares elliptical fitting

A method of analyzing Faraday rotation data from pulsed magnetic field measurements is described. The method uses direct least-squares elliptical fitting to measured data. The least-squares fit conic parameters are used to rotate, translate, and rescale the measured data. Interpretation of the transformed data provides improved accuracy and time-resolution characteristics compared with many existing methods of analyzing Faraday rotation data. The method is especially useful when linear birefringence is present at the input or output of the sensing medium, or when the relative angle of the polarizers used in analysis is not aligned with precision; under these circumstances the method is shown to return the analytically correct input signal. The method may be pertinent to other applications where analysis of Lissajous figures is required, such as the velocity interferometer system for any reflector (VISAR) diagnostics. The entire algorithm is fully automated and requires no user interaction. An example of algorithm execution is shown, using data from a fiber-based Faraday rotation sensor on a capacitive discharge experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCINTILLATION ARCS IN LOW-FREQUENCY OBSERVATIONS OF THE TIMING-ARRAY MILLISECOND PULSAR PSR J0437–4715

Low-frequency observations of pulsars provide a powerful means for probing the microstructure in the turbulent interstellar medium (ISM). Here we report on high-resolution dynamic spectral analysis of our observations of the timing-array millisecond pulsar PSR J0437–4715 with the Murchison Widefield Array (MWA), enabled by our recently commissioned tied-array beam processing pipeline for voltage data recorded from the high time resolution mode of the MWA. A secondary spectral analysis reveals faint parabolic arcs akin to those seen in high-frequency observations of pulsars with the Green Bank and Arecibo telescopes. Data from Parkes observations at a higher frequency of 732 MHz reveal a similar parabolic feature with a curvature that scales approximately as the square of the observing wavelength (λ{sup 2}) to the MWA's frequency of 192 MHz. Our analysis suggests that scattering toward PSR J0437–4715 predominantly arises from a compact region about 115 pc from the Earth, which matches well with the expected location of the edge of the Local Bubble that envelopes the local Solar neighborhood. As well as demonstrating new and improved pulsar science capabilities of the MWA, our analysis underscores the potential of low-frequency pulsar observations for gaining valuable insights into the local ISM and for characterizing the ISM toward timing-array pulsars.

79 ASTRONOMY AND ASTROPHYSICS↗

The 825-1110 angstroms EUV spectrum of Venus

On 15 August 1994 we launched the EUVS sounding rocket payload to observe the 825-1110 angstrom region of Venus's far ultraviolet airglow spectrum. The EUVS telescope/spectrograph obtained good data at five times higher spectral resolution than was previously available in the far ultraviolet. We present these data and compare our results to those obtained by the Galileo UVS and Venera 11/12 UV spectrophotometers. We identify several new spectral emission features, including both singly ionized nitrogen and molecular nitrogen in Venus's spectrum. We also see evidence for electron-impact-induced emission from CO. Finally, the EUVS data indicate that the "Ar" emissions detected in Venus's far ultraviolet spectrum by Venera 11/12 spectrophotometers are in fact not due to argon, thus eliminating the discrepancy between in situ and remote sensing measurements.

Flight Experiment↗

Multi-Sensor Integration of Vegetation Index Products for Long-Term Monitoring of Vegetation Dynamics: A Case Study from MODIS to VIIRS

Spectral vegetation index (VI) time series data from moderate resolution sensors, such as Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS), have widely been used to identify "hot spot" areas of vegetation changes and to characterize long-term trends of vegetation changes. The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor series of the Joint Polar Satellite System (JPSS) program is slated to continue the highly calibrated data stream initiated with MODIS. The first VIIRS sensor has operationally been acquiring Earth-reflected radiation since March 2012. The second VIIRS sensor (NOAA-20) was launched in November 2017, which is to continue the measurements made by the first VIIRS sensor. In this study, we examined an integrated use of MODIS and VIIRS VI time series data on capturing vegetation dynamics in the Asia-Pacific region using their overlapped period of observations (2013-2017). Three VIs, the "top-of-canopy (TOC)" normalized difference vegetation index (NDVI), TOC enhanced vegetation index (EVI), and TOC two-band enhanced vegetation index (EVI2), were investigated. For all the three VIs, VIIRS VIs were systematically higher than the MODIS counterparts due mainly to their spectral bandpass differences. However, both VIIRS and MODIS VIs showed the comparable spatial patterns in their temporal variations. Empirical spectral corrections allowed to merge the two data streams, which slightly improved the temporal resolution of the VI temporal profiles. These results suggest the suitability of VIIRS data to extend and merge into the MODIS VI record for long-term vegetation dynamics studies.

MODIS↗

Analysis and Modeling of the End-to-End I/O Performance on OLCF's Titan Supercomputer

With the increase of scale and complexity seen in a variety of leadership-class scientific computation and simulation applications, it has become more important to understand their I/O performance characteristics. The user-observed performance is a combination of properties of how the application is using the HPC facility, as well as how others' use of the facility causes variability in the static machine capabilities. Our work leverages statistical analysis of I/O performance data gathered with fine time resolution over a full week from Titan supercomputer. Based on observed properties of the distribution of I/O latencies, we build a three-state hidden Markov model (HMM) to characterize the end-to-end I/O performance on Titan. We parameterize our model using part of the field-gathered I/O performance data and validate it against the rest. The validation results demonstrate that our model can capture the dynamics of end-to-end I/O performance on Titan accurately.

Wan, Lipeng↗