Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-IeP4-03: Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field

Purpose: Cone beam X-ray luminescence computed tomography (CB-XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. However, the inverse problem of CB-XLCT is seriously ill-conditioned, hindering us to achieve good image quality. In this work, a novel reconstruction method based on Bayesian theory is proposed to tackle this problem Methods: Bayesian theory provides a natural framework for utilizing various kinds of available prior information to improve the reconstruction image quality. A generalized Gaussian Markov random field (GGMRF) model is proposed here to construct the prior model of the Bayesian theory. The most important feature of GGMRF model is the adjustable shape parameter p, which can be continuously adjusted from 1 to 2. The reconstruction image tends to have more edge-preserving property when p is slide to 1, while having more noise tolerance property when p is slide to 2, just like the behavior of L1 and L2 regularization methods, respectively. The proposed method provides a flexible regularization framework to adapt to a wide range of applications. Results: Numerical simulations were implemented to test the performance of the proposed method. The Digimouse atlas were employed to construct a three-dimensional mouse model, and two small cylinders were placed inside to serve as the targets. Reconstruction results show that the proposed method tends to obtain better spatial resolution with a smaller shape parameter, while better signal-to-noise image with a larger shape parameter. Quantitative indexes, contrast-to-noise ratio (CNR) and full-width at half-maximum (FWHM), were used to assess the performance of the proposed method, and confirmed its effectiveness in CB-XLCT reconstruction. Conclusion: A novel reconstruction method for CB-XLCT is proposed based on GGMRF model, which enables an adjustable performance tradeoff between L1 and L2 regularization methods. Numerical simulations were conducted to demonstrate its performance.

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-02: Material Reconstruction for Spectral Computed Tomography with Detector Response Function

Purpose: Different from the conventional computed tomography (CT), spectral CT based on energy-resolved photon-counting detectors is able to provide the unprecedented material composition. However, an important missing piece for accurate spectral CT is to incorporate the detector response function (DRF), which is distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. Methods: The polyenergetic X-ray forward model takes the DRF into account for accurate material reconstruction. Two image reconstruction methods are proposed: a direct method based on the nonlinear data fidelity from DRF-based forward model; a linear-data-fidelity based method that relies on the spectral rebinning so that the corresponding DRF matrix is invertible. Then the image reconstruction problem is regularized with the isotropic TV term and solved by alternating direction method of multipliers. Results: The simulation results suggest that the proposed methods provided more accurate material compositions than the standard method without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Conclusion: We have proposed material reconstruction methods for spectral CT with DRF, whichprovided more accurate material compositions than the standard methods without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Jiulong Liu and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

Polarization Tomography of Residual Stresses in Cylindrical Gradient-Index Lenses

In most cases, cylindrical structures with a gradient refractive index (GRIN) are formed on the basis of diffusion technology. The refractive index and the residual stresses in them are axially symmetrical. The distortion determined by diffusion and the thermal internal stresses in them are simulated by the fictive temperature of residual stresses. The use of the integral photoelasticity for the reconstruction of residual stresses in GRIN lenses is usually limited to the case of a planar deformed state. In this study, this algorithm is extended to the case of the axial change of residual stresses. It is assumed that the illumination procedure is carried out in the sample cross section. The optical problem is solved within the quasi-isotropic approximation. The reconstruction is based on measuring the characteristic parameters of polarized light passed through the sample and on the combined solution of the thermoelasticity problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

A pencil beam approach to proton computed tomography

Purpose: A new approach to proton computed tomography (pCT) is presented. In this approach, protons are not tracked one-by-one but a beam of particles is considered instead. The elements of the pCT reconstruction problem (residual energy and path) are redefined on the basis of this new approach. An analytical image reconstruction algorithm applicable to this scenario is also proposed. Methods: The pencil beam (PB) and its propagation in matter were modeled by making use of the generalization of the Fermi–Eyges theory to account for multiple Coulomb scattering (MCS). This model was integrated into the pCT reconstruction problem, allowing the definition of the mean beam path concept similar to the most likely path (MLP) used in the single-particle approach. A numerical validation of the model was performed. The algorithm of filtered backprojection along MLPs was adapted to the beam-by-beam approach. The acquisition of a perfect proton scan was simulated and the data were used to reconstruct images of the relative stopping power of the phantom with the single-proton and beam-by-beam approaches. The resulting images were compared in a qualitative way. Results: The parameters of the modeled PB (mean and spread) were compared to Monte Carlo results in order to validate the model. For a water target, good agreement was found for the mean value of the distributions. As far as the spread is concerned, depth-dependent discrepancies as large as 2%–3% were found. For a heterogeneous phantom, discrepancies in the distribution spread ranged from 6% to 8%. The image reconstructed with the beam-by-beam approach showed a high level of noise compared to the one reconstructed with the classical approach. Conclusions: The PB approach to proton imaging may allow technical challenges imposed by the current proton-by-proton method to be overcome. In this framework, an analytical algorithm is proposed. Further work will involve a detailed study of the performances and limitations of this approach in terms of image quality. The paper shows how to account for the MCS in the reconstruction step with this new approach when an analytical reconstruction algorithm is used.

60 APPLIED LIFE SCIENCES↗

Three-dimensional tomographic imaging for dynamic radiation behavior study using infrared imaging video bolometers in large helical device plasma

A three-dimensional (3D) tomography system using four InfraRed imaging Video Bolometers (IRVBs) has been designed with a helical periodicity assumption for the purpose of plasma radiation measurement in the large helical device. For the spatial inversion of large sized arrays, the system has been numerically and experimentally examined using the Tikhonov regularization with the criterion of minimum generalized cross validation, which is the standard solver of inverse problems. The 3D transport code EMC3-EIRENE for impurity behavior and related radiation has been used to produce phantoms for numerical tests, and the relative calibration of the IRVB images has been carried out with a simple function model of the decaying plasma in a radiation collapse. The tomography system can respond to temporal changes in the plasma profile and identify the 3D dynamic behavior of radiation, such as the radiation enhancement that starts from the inboard side of the torus, during the radiation collapse. The reconstruction results are also consistent with the output signals of a resistive bolometer. These results indicate that the designed 3D tomography system is available for the 3D imaging of radiation. The first 3D direct tomographic measurement of a magnetically confined plasma has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Missing Wedge Completion via Unsupervised Learning with Coordinate Networks

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3–20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.

42 ENGINEERING↗

Application of deep neural networks to improve diagnostic accuracy of rheumatoid arthritis using diffuse optical tomography

A set of deep neural network models for rheumatoid arthritis (RA) classification using a highway network, a convolutional neural network and a residual network is proposed based on the data of diffuse optical tomography (DOT) utilising near-infrared light, which ensures early diagnosis of pathophysiological changes resulting from inflammation. A numerical model of the finger is used to generate images to overcome the inherent problem of insufficient clinical DOT images available. The proposed deep neural network models are applied to automatically classify simulated DOT images of inflamed and non-inflamed joints and transfer learning is also used to improve the performance of the classification. The results demonstrate that all three deep neural network methods improve the diagnostic accuracy as compared to the widely applied support vector machine (SVM), especially for high inter-subject variability databases. In cases of distinct modelled severity of disease, residual network achieved the highest accuracy (> 99 %), and both of highway and convolutional neural networks reached 99 %, respectively. However, as the severity of the modelled disease is reduced, this accuracy is reduced to 75.2 % for residual networks. The results indicate that transfer learning can improve the performance of deep neural network methods on RA classification from DOT data and highlight their potential as a computer aided tool in DOT diagnostic systems. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-assisted generative adversarial network for X-ray tomography

X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory results. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori , deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Compared with methods with less physics assisting in training, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. The advantages of using a physics-assisted learned prior in X-ray tomography may further enable low-photon nanoscale imaging.

47 OTHER INSTRUMENTATION↗

Electrical Capacitance Volume Tomography: A Comparison between 12- and 24-Channels Sensor Systems

Spatial resolution represents akey performance aspect in electrical capacitance volume tomography (ECVT). Factors affecting the resolution include the ``soft-field'' nature of ECVT, the number of capacitance channels used, the ill-conditioned nature of the imaging reconstruction problem, and the signal-to-noise ratio of the measurement apparatus. In this study, the effect of choosing different numbers of capacitance plates on the performance of ECVT is investigated. Specifically, two ECVT sensors with 12 and 24 capacitance channels but covering equal volumes of a cylinder are used to examine the resulting impact on the image resolution.

20 FOSSIL-FUELED POWER PLANTS↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

K Elliott Cramer↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

NDE↗

An iterative particle filter approach for coupled hydro-geophysical inversion of a controlled infiltration experiment

The modeling of unsaturated groundwater flow is affected by a high degree of uncertainty related to both measurement and model errors. Geophysical methods such as Electrical Resistivity Tomography (ERT) can provide useful indirect information on the hydrological processes occurring in the vadose zone. In this paper, we propose and test an iterated particle filter method to solve the coupled hydrogeophysical inverse problem. We focus on an infiltration test monitored by time-lapse ERT and modeled using Richards equation. The goal is to identify hydrological model parameters from ERT electrical potential measurements. Traditional uncoupled inversion relies on the solution of two sequential inverse problems, the first one applied to the ERT measurements, the second one to Richards equation. This approach does not ensure an accurate quantitative description of the physical state, typically violating mass balance. To avoid one of these two inversions and incorporate in the process more physical simulation constraints, we cast the problem within the framework of a SIR (Sequential Importance Resampling) data assimilation approach that uses a Richards equation solver to model the hydrological dynamics and a forward ERT simulator combined with Archie's law to serve as measurement model. ERT observations are then used to update the state of the system as well as to estimate the model parameters and their posterior distribution. The limitations of the traditional sequential Bayesian approach are investigated and an innovative iterative approach is proposed to estimate the model parameters with high accuracy. The numerical properties of the developed algorithm are verified on both homogeneous and heterogeneous synthetic test cases based on a real-world field experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser refractive tomography of phase objects

The principles are outlined of laser refractive tomography - a method for reconstructing the values of the refractive index in the cross sections of phase objects, which involves the use of three-dimensional refractive images (3D refractograms) of structured laser radiation. A simulation algorithm is realised and examples are provided of characteristic 3D refractograms obtained by solving the direct problem of refraction of structured radiation. A method was developed for reconstructing the values of refractive index under conditions of strong refraction, which is based on the visualisation of ray trajectories inside an optically inhomogeneous medium. A classification is made of possible approaches to the solution of the inverse problem of refraction based on the visualisation of ray trajectories. Examples are given of cross section reconstruction and quantitative diagnostics of phase objects. (laser imaging)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limited-angle computed tomography with deep image and physics priors

Computed tomography is a well-established x-ray imaging technique to reconstruct the three-dimensional structure of objects. It has been used extensively in a variety of fields, from diagnostic imaging to materials and biological sciences. One major challenge in some applications, such as in electron or x-ray tomography systems, is that the projections cannot be gathered over all the angles due to the sample holder setup or shape of the sample. This results in an ill-posed problem called the limited angle reconstruction problem. Typical image reconstruction in this setup leads to distortion and artifacts, thereby hindering a quantitative evaluation of the results. To address this challenge, we use a generative model to effectively constrain the solution of a physics-based approach. Our approach is self-training that can iteratively learn the nonlinear mapping from partial projections to the scanned object. Because our approach combines the data likelihood and image prior terms into a single deep network, it is computationally tractable and improves performance through an end-to-end training. We also complement our approach with total-variation regularization to handle high-frequency noise in reconstructions and implement a solver based on alternating direction method of multipliers. We present numerical results for various degrees of missing angle range and noise levels, which demonstrate the effectiveness of the proposed approach.

47 OTHER INSTRUMENTATION↗

Beyond Darcy's law: The role of phase topology and ganglion dynamics for two-fluid flow

Relative permeability quantifies the ease at which immiscible phases flow through porous rock and is one of the most well known constitutive relationships for petroleum engineers. It however exhibits troubling dependencies on experimental conditions and is not a unique function of phase saturation as commonly accepted in industry practices. The problem lies in the multi-scale nature of the problem where underlying disequilibrium processes create anomalous macroscopic behavior. Here we show that relative permeability rate dependencies are explained by ganglion dynamic flow. We utilize fast X-ray micro-tomography and pore-scale simulations to identify unique flow regimes during the fractional flow of immiscible phases and quantify the contribution of ganglion flux to the overall flux of non-wetting phase. We anticipate our approach to be the starting point for the development of sophisticated multi-scale flow models that directly link pore-scale parameters to macro-scale behavior. Such models will have a major impact on how we recover hydrocarbons from the subsurface, store sequestered CO 2 in geological formations, and remove non-aqueous environmental hazards from the vadose zone.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Texture analysis improves level set segmentation of the anterior abdominal wall

Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore, to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and texture analysis can improve the level set segmentation around the abdominal region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗