Search NASA⌕ Search

SEARCH · Search NASA

Results for “total dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The damage equivalence of electrons, protons, alphas and gamma rays in rad-hard MOS devices

This paper reports on a study of damage equivalence in rad-hard MOS devices with 100,000 rads (SiO2) capability. Damage sensitivities for electrons of 1, 2, 3, 5, and 7 MeV, protons of 1, 3, 7, 22, and 40 MeV, 3.4-MeV alphas, and Co-60 gammas were measured and compared. Results indicated that qualitatively the same charge recombination effects occurred in hard oxide devices for doses of 100,000 rads (SiO2) as in soft oxide parts for doses of 1 to 4 krads (SiO2). Consequently, damage equivalency or non-equivalency depended on radiation type and energy. However, recovery effects, both during and after irradiation, controlled relative damage sensitivity and its dependency on total dose, dose rate, supply bias, gate bias, radiation type, and energy. Correction factors can be derived from these data or from similar tests of other hard oxide type, so as to properly evaluate the combined effects of the total space environment.

Stassinopoulos, E. G.↗

Dosimetric results from the Mir orbital station

The Mir Orbital Station provided a unique platform on which to carry out a variety of space radiation dosimetry measurements. A number of experiments were conducted using a combination of passive detectors on the interior of the Mir during 1996-97. Thermoluminescent detectors were used to measure absorbed dose. CR-39 plastic nuclear track detectors were used to measure the LET spectra > or =5 keV.microm(-1). Results from TLDs and CR-39 PNTDs were combined to determine total dose and dose equivalent. Mean dose rate was found to decrease while mean dose equivalent rate and average quality factor increased with increasing shielding. Secondary particles from proton-induced target fragmentation interactions, not primary HZE particles, were found to be the largest contributor to the LET spectrum above 100 keV.microm(-1). During the 1997 measurements, mean quality factor was found to vary from 1.7 to 2.1 as a function of location within the Mir.

long duration↗

Evaluation of the hazard from exposure to electron irradiation simulating that in the synchronous orbit

The electron spectrum predicted for the synchronous orbit was simulated to determine the effects that might occur to astroscientists exposed to such irradiation while on a prolonged space station mission in that region. Miniature pigs were exposed to monoenergetic and spectral-fractionated irradiations with 0.5 to 2.1 MeV electrons. Clinical and pathological alterations observed in biopsies were correlated with depth-dose pattern and length of post irradiation period up to one year. With monoenergetic electrons, the lowest dose causing a recognizable lesion was 1450 rad and with increasing dose lesions appeared earlier and were more severe. At the highest dose given, 2650 rad, ulceration extending into the dermis was present by twenty one days and required about four months for complete healing. Spectral-fractionated irradiations, in which the total dose range was essentially comparable to that of the monoenergetic series, resulted in very minimal outer dermis edema at 1790 rad and at no dose employed did necrosis of epidermis or ulceration into dermis occur.

Lippincott, S. W.↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors factor that will impact health of astronauts on extended missions outside the protective effects of the Earth's magnetic field. Currently there are gaps in our knowledge of the health risks associated with chronic low dose, low dose rate ionizing radiation, specifically ions associated with high (H) atomic number (Z) and energy (E). The NASA GeneLab project (genelab.nasa.gov) aims to provide a detailed library of Omics datasets associated with biological samples exposed to HZE. The GeneLab Data System (GLDS) includes datasets from both spaceflight and ground-based studies, a majority of which involved exposure to ionizing radiation. Recently GeneLab has also assessed radiation dosimetry data with omics datasets associated with samples flown to the International Space Station (ISS). The combination of the detailed information on radiation exposure for ground-based studies and curated dosimetry information for spaceflight experiments allows GeneLab to be the first comprehensive Omics database for space related research from which an investigator can generate hypotheses to direct future experiments utilizing both ground and space biological radiation data. We demonstrate the usefulness of these datasets by analyzing multiple GeneLab datasets associated with both radiation ground-based studies and spaceflight studies. The radiation ground based studies we analyzed includes both in vivo and in vitro work with a range ions from protons to iron particles with doses from 0.1Gy to 2Gy. These datasets were compared to both in vivo and in vitro datasets from samples flown to the ISS and on shorter shuttle missions with total doses of 0.1 mGy to 30 mGys. From this analysis we were able to associate distinct biological signatures associating specific ions to specific biological response to radiation exposure in space. For example, we discovered radiation biological response related to cardiovascular effects from proton ground studies are the dominating response for samples related to cardiovascular effects on the ISS. With this work we will provide a summary of how different ions will impact different biological response in space and how this can be used in future studies to assess optimal ground experiments to simulate space radiation.

Beheshti, Afshin↗

Space radiation effects on the dimensional stability of a toughened epoxy graphite composite

The effects of a simulated space radiation environment on the dimensional stability of an elastomer-toughened epoxy-graphite composite were determined. The response of the material was characterized following exposure to radiation doses equivalent to geosynchronous orbit lifetimes ranging from 6 months to 30 years. The results show that radiation interacts with the epoxy matrix to embrittle the composite, beginning at relatively low total doses (10 to the 7th power rads). The embrittlement results in thermal expansion changes and significant laminate microcracking during thermal cycling. These property changes could limit the service life of this material in some spacecraft applications.

Sykes, G. F.↗

Risk analysis: divergent models and convergent interpretations

Material presented at a NASA-sponsored workshop on risk models for exposure conditions relevant to prolonged space flight are described in this paper. Analyses used mortality data from experiments conducted at Argonne National Laboratory on the long-term effects of external whole-body irradiation on B6CF1 mice by 60Co gamma rays and fission neutrons delivered as a single exposure or protracted over either 24 or 60 once-weekly exposures. The maximum dose considered was restricted to 1 Gy for neutrons and 10 Gy for gamma rays. Proportional hazard models were used to investigate the shape of the dose response at these lower doses for deaths caused by solid-tissue tumors and tumors of either connective or epithelial tissue origin. For protracted exposures, a significant mortality effect was detected at a neutron dose of 14 cGy and a gamma-ray dose of 3 Gy. For single exposures, radiation-induced mortality for neutrons also occurred within the range of 10-20 cGy, but dropped to 86 cGy for gamma rays. Plots of risk relative to control estimated for each observed dose gave a visual impression of nonlinearity for both neutrons and gamma rays. At least for solid-tissue tumors, male and female mortality was nearly identical for gamma-ray exposures, but mortality risks for females were higher than for males for neutron exposures. As expected, protracting the gamma-ray dose reduced mortality risks. Although curvature consistent with that observed visually could be detected by a model parameterized to detect curvature, a relative risk term containing only a simple term for total dose was usually sufficient to describe the dose response. Although detectable mortality for the three pathology end points considered typically occurred at the same level of dose, the highest risks were almost always associated with deaths caused by tumors of epithelial tissue origin.

Non-NASA Center↗

Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

Chen, Dakai↗

Prediction of error rates in dose-imprinted memories on board CRRES by two different methods

An analysis of the expected space radiation effects on the single event upset (SEU) properties of CMOS/bulk memories onboard the Combined Release and Radiation Effects Satellite (CRRES) is presented. Dose-imprint data from ground test irradiations of identical devices are applied to the predictions of cosmic-ray-induced space upset rates in the memories onboard the spacecraft. The calculations take into account the effect of total dose on the SEU sensitivity of the devices as the dose accumulates in orbit. Estimates of error rates, which involved an arbitrary selection of a single pair of threshold linear energy transfer (LET) and asymptotic cross-section values, were compared to the results of an integration over the cross-section curves versus LET. The integration gave lower upset rates than the use of the selected values of the SEU parameters. Since the integration approach is more accurate and eliminates the need for an arbitrary definition of threshold LET and asymptotic cross section, it is recommended for all error rate predictions where experimental sigma-versus-LET curves are available.

Brucker, G. J.↗

The influence of dose, dose-rate and particle fragmentation on cataract induction by energetic iron ions

Because activities in space necessarily involve chronic exposure to a heterogeneous charged particle radiation field it is important to assess the influence of dose-rate and the possible modulating role of heavy particle fragmentation on biological systems. Using the well-studied cataract model, mice were exposed to plateau 600 MeV/amu Fe-56 ions either as acute or fractionated exposures at total doses of 5-504 cGy. Additional groups of mice received 20, 360 and 504 cGy behind 50 mm of polyethylene, which simulates body shielding. The reference radiation consisted of Co-60 gamma radiation. The animals were examined by slit lamp biomicroscopy over their three year life spans. In accordance with our previous observations with heavy particles, the cataractogenic potential of the 600 MeV/amu Fe-56 ions was greater than for low-Linear Energy Transfer (LET) radiation and increased with decreasing dose relative to gamma rays. Fractionation of a given dose of Fe-56 ions did not reduce the cataractogenicity of the radiation compared to the acute regimen. Fragmentation of the beam in the polyethylene did not alter the cataractotoxicity of the ions, either when administered singly or in fractions.

Medvedovsky, C.↗

The risk of solar proton events to space missions

The total dose in rads-tissue from solar protons was tabulated for weekly time intervals, and the number of weeks which gave a dose above 25 rads behind 10 g/sq cm of aluminum for the active 6 years of the 19th cycle were called dangerous or large event weeks. The number of such event weeks was found to be only 3 weeks for the past 20 years. Even though the chance for smaller events is examined, it was found that for any reasonable, high confidence level (95%), the smaller events could be ignored. Consequently, the total particle flux for the 19th cycle was divided by a factor of 3 and determined a single large event week. Using this spectrum, the tissue dose in rads is calculated at the center of an aluminum spherical shell.

Burrell, M. O.↗

Passive dosimetry aboard the Mir Orbital Station: external measurements

This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope. c2002 Elsevier Science Ltd. All rights reserved.

manned↗

Space radiation dosimetry in low-Earth orbit and beyond

Space radiation dosimetry presents one of the greatest challenges in the discipline of radiation protection. This is a result of both the highly complex nature of the radiation fields encountered in low-Earth orbit (LEO) and interplanetary space and of the constraints imposed by spaceflight on instrument design. This paper reviews the sources and composition of the space radiation environment in LEO as well as beyond the Earth's magnetosphere. A review of much of the dosimetric data that have been gathered over the last four decades of human space flight is presented. The different factors affecting the radiation exposures of astronauts and cosmonauts aboard the International Space Station (ISS) are emphasized. Measurements made aboard the Mir Orbital Station have highlighted the importance of both secondary particle production within the structure of spacecraft and the effect of shielding on both crew dose and dose equivalent. Roughly half the dose on ISS is expected to come from trapped protons and half from galactic cosmic rays (GCRs). The dearth of neutron measurements aboard LEO spacecraft and the difficulty inherent in making such measurements have led to large uncertainties in estimates of the neutron contribution to total dose equivalent. Except for a limited number of measurements made aboard the Apollo lunar missions, no crew dosimetry has been conducted beyond the Earth's magnetosphere. At the present time we are forced to rely on model-based estimates of crew dose and dose equivalent when planning for interplanetary missions, such as a mission to Mars. While space crews in LEO are unlikely to exceed the exposure limits recommended by such groups as the NCRP, dose equivalents of the same order as the recommended limits are likely over the course of a human mission to Mars. c2001 Elsevier Science B.V. All rights reserved.

short duration↗

Radiation-Tolerant DC-DC Converters

A document discusses power converters suitable for space use that meet the DSCC MIL-PRF-38534 Appendix G radiation hardness level P classification. A method for qualifying commercially produced electronic parts for DC-DC converters per the Defense Supply Center Columbus (DSCC) radiation hardened assurance requirements was developed. Development and compliance testing of standard hybrid converters suitable for space use were completed for missions with total dose radiation requirements of up to 30 kRad. This innovation provides the same overall performance as standard hybrid converters, but includes assurance of radiation- tolerant design through components and design compliance testing. This availability of design-certified radiation-tolerant converters can significantly reduce total cost and delivery time for power converters for space applications that fit the appropriate DSCC classification (30 kRad).

Skutt, Glenn↗

Active dosimetric measurements on Shuttle flights

A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of LET and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 deg x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.

Badhwar, Gautam D.↗

Characterization of the Radiation Shielding Properties of U.S. and Russian Extravehicular Activity Suits

Reported herein are results from the Eril Research, Inc. (ERI) participation in the JSC-sponsored study characterizing the radiation shielding properties of the two types of space suit that astronauts are wearing during the EVA on-orbit assembly of ISS. Measurements using passive detectors were carried out to assess the shielding properties of the U.S. EMU Suit and the Russian Orlan-M suit during irradiations of the suits and a tissue-equivalent phantom to monoenergetic proton and electron beams at LLUMC. During irradiations of 6 MeV electrons and 60 MeV protons, absorbed dose as a function of depth was measured using TLDs exposed behind swatches of the two suit materials and inside the two EVA helmets. Considerable reduction in electron dose was measured behind all suit materials in exposures to 6 MeV electrons. Slowing of the proton beam in the suit materials led to an increase in dose measured in exposures to 60 MeV protons. During 232 MeV proton irradiations, measurements were made with TLDs and CR-39 PNTDs at five organ locations inside a tissue-equivalent phantom, exposed both with and without the two EVA suits. The EVA helmets produce a 13% to 27% reduction in total dose and a 0% to 25% reduction in dose equivalent when compared to measurements made in the phantom head alone. Differences in dose and dose equivalent between the suit and non-suit irradiations for the lower portions of the two EVA suits tended to be smaller. Proton-induced target fragmentation was found to be a significant source of increased dose equivalent, especially within the two EVA helmets, and average quality factor inside the EMU and Orlan-M helmets was 2% to 14% greater than that measured in the bare phantom head.

Benton, E. R.↗

Dried Plum Diet Prevents Bone Loss Caused by Ionizating Radiation: Reduces Pro-Resorption Cytokine Expression, and Protects Marrow-Derived Osteoprogenitors

Future long duration missions outside the protection of the Earth's magnetosphere, or unshielded exposures to solar particle events, achieves total doses capable of causing cancellous bone loss. Cancellous bone loss caused by ionizing radiation occurs quite rapidly in rodents: Initially, radiation increases the number and activity of bone-resorbing osteoclasts, followed by decrease in bone forming osteoblast cells. Here we report that Dried Plum (DP) diet completely prevented cancellous bone loss caused by ionizing radiation (Figure 1). DP attenuated marrow expression of genes related to bone resorption (Figure 2), and protected the bone marrow-derived pre-osteoblasts ex vivo from total body irradiation (Figure 3). DP is known to inhibit resorption in models of aging and ovariectomy-induced osteopenia; this is the first report that dietary DP is radioprotective.

Radioprotective↗

Comparison of the NAIRAS Trajectory Dose Model With ISS Measurements: Effects of Trapped Particles and Solar Energetic Particle Events.

The NAIRAS(Nowcast of Aerospace Ionizing RAdiation system) model was initially developed for fast computation of GCR and SEP events in the Earth's atmosphere. It was recently improved for computing the effects of trapped particles and its domain of validity was extended to the near space environments, which notably includes the international space station (ISS). To validate the new capabilities of the model, we compared its outputs with some measurements made in the ISS. Historical data contained several SEP events while newer measurements made with the ARMAS instrument flying in the experience bay of KIBO show the influence of trapped particles and GCR over the total dose received.

Guillaume Gronoff↗

Low Energy Ionizing Radiation and Plasma Contributions to Radiation Dose in Materials at Sun-Earth Lagrange Points

- High energy radiation environments responsible for radiation damage to thick materials are well characterized and modeled: - Galactic cosmic rays — Badhwar-O’Neil 2020, CREME96, Nymmik - Solar particle events — Emission of Solar Protons, SAPPHIRE, JPL, King 1972 - Trapped radiation belts — AE8/AP8, AE9/AP9/IRENE - Low energy radiation environments responsible for radiation damage to thin materials relevant to Lagrange points and interplanetary missions have not been treated as comprehensively to date: - Solar wind - Magnetosheath - Magnetotail - Concern to spacecraft design and operations is radiation damage to surfaces and thin materials with mission critical applications on exterior of spacecraft - Applications: thermal control coatings, sunshields, multilayer insulation, optical thin film coatings, solar sails, thermo-optical properties of space exposed materials - Damage processes: radiation degradation (total dose), light ion sputtering, proton blistering of soft metals, modification of optical properties (α/ε), modification of charging properties (SEY, surface conductivity)

Joseph I. Minow↗