Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission lines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection (Final Report)

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on time domain protection which utilizes traveling waves measured on the transmission lines to detect the fault within a tower span. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for on a new protective relay technology that has the potential to change protective relaying. For time domain protection a GPS resilient architecture was implemented and tested for time domain protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for traveling wave protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Trip Coils

A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Chapter 11: Renewable Microgrids as a Foundation of the Future Sustainable Electrical Energy System

Renewable microgrids are an integral part of the future sustainable energy system. This chapter focuses on the role of renewable energy-based microgrids in the electricity system transformation. It is seen as a foundation that complements large-scale generation plants and high-voltage transmission lines by providing additional flexibility and resilience. This flexibility and resilience are crucial for balancing the energy system and ensuring its long-term sustainability, given the changing supply and demand patterns due to rooftop solar photovoltaics (PV), battery storage, electric mobility, and heat pumps. It is also an opportunity for residential and commercial consumers to become active participants in the energy market. Innovation, new technologies and business models will act as the key enabler for this transformation. The regulatory restructuring of the energy market will be crucial for successful integration of prosumers and aggregated energy communities. The chapter presents the vision of a sustainable, decentralized, and digitized energy future including market potential, most innovative case study projects and start-up companies, and the shifts needed in the regulatory landscape.

battery storage↗

On the Low Risk of SSR in Type III Wind Turbines Operating with Grid-Forming Control

We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This paper explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. Here it is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.

17 WIND ENERGY↗

Unalakleet Microgrid Optimization for Tribal Community Resilience

The Unalakleet Microgrid Optimization Project aimed to strengthen the reliability and efficiency of the isolated electric power system that serves the Tribal community of Unalakleet, Alaska. The community relies entirely on a local wind-diesel microgrid, consisting of four 475 kW diesel generators and six 100 kW wind turbines, to provide electricity to approximately 745 residents and Tribal facilities. Because Unalakleet is not on a road system and is located nearly 400 miles from the nearest major power grid, maintaining a resilient and efficient local energy system is critical. The scope of this project included upgrading a portion of the transmission line between the wind farm and the power plant to increase voltage and reduce line losses, along with modernizing the Supervisory Control and Data Acquisition (SCADA) system to improve monitoring, control, and data management of the power system. These upgrades were designed to increase wind energy utilization, reduce diesel fuel consumption by tens of thousands of gallons annually, and improve overall grid stability. By allowing more of the community’s electricity to be supplied by local renewable wind resources, the project was designed to lower operating costs, reduce dependence on imported fuel, and strengthen the long-term resilience of the power system. These improvements represent an important step toward the community’s long-term energy vision of expanding renewable generation, incorporating energy storage, and eventually achieving “diesels-off” operation, where essential Tribal loads are powered primarily by local renewable resources.

17 WIND ENERGY↗

Life Cycle Cost Analysis of Prestressed Concrete Poles Subjected to Wind, Surges, and Waves

Prestressed concrete (PC) poles are becoming popular choices to support coastal power transmission systems. However, the existing literature does not offer a detailed analysis of the effectiveness of PC poles in terms of long-term vulnerabilities and the direct and indirect costs. This is due to (1) lack of fragility models for PC poles and (2) lack of probabilistic wind, storm surge, and wave models in coastal settings. In this study, we address these gaps through a series of Monte Carlo simulations to estimate fragility of PC poles as a function of age and hazard (wind, surges, and waves) intensity, and the development of a probabilistic hazard model based on 10,000 years of synthetic tropical cyclone data. The probabilistic hazard model is used in conjunction with high-resolution hydrodynamic models to generate realizations of coastal wind, storm surges, and waves for the Louisiana and Mississippi coasts. A comprehensive life cycle cost analysis for a service life of 70 years considering direct and indirect losses is conducted to compare the performance of a transmission line located in Pascagoula, Mississippi, when wood poles are replaced by PC poles. Results showed that aging has a minor effect on the reliability of PC poles, highlighting the advantages of replacing wood poles with PC poles, especially in coastal areas. In addition, PC poles are significantly more cost-effective compared with wood poles over their life cycle, leading to an estimated saving of $11.55 million (68.17% reduction). The results of this study provide key insight to inform decision-making processes to keep the coastal power grids resilient and cost-effective against future storm hazards.

natural disasters↗

On the Low Risk of Subsynchronous Resonance (SSR) in Type III Wind Turbines Operating in Grid-Forming Control

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems’ Extreme Weather Resilience

We present scalable stochastic optimization approaches for improving power systems’ resilience to extreme weather events. We consider both proactive redispatch and transmission line hardening as alternatives for mitigating expected load shed due to extreme weather, resulting in large-scale stochastic linear programs (LPs) and mixed-integer linear programs (MILPs). We solve these stochastic optimization problems with progressive hedging (PH), a parallel, scenario-based decomposition algorithm. Our computational experiments indicate that our proposed method for enhancing power system resilience can provide high-quality solutions efficiently. With up to 128 scenarios on a 2,000-bus network, the operations (redispatch) and investment (hardening) resilience problems can be solved in approximately 6 min and 2 h of wall-clock time, respectively. Additionally, we solve the investment problems with up to 512 scenarios, demonstrating that the approach scales very well with the number of scenarios. Moreover, the method produces high quality solutions that result in statistically significant reductions in expected load shed. Our proposed approach can be augmented to incorporate a variety of other operational and investment resilience strategies, or a combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical and architectural intricacy from nanoscale tetrahedra and their analogues

The tetrahedron, as the simplest platonic shape, is a profound building block with the potential to create intricate superstructures. Noteworthy designs utilizing tetrahedral building blocks include the Sierpiński tetrahedron (the most fundamental three-dimensional fractal), a one-dimensional helical structure known as the tetrahelix, and various crystalline and quasicrystalline packings. Historically, the practicality of tetrahedral superstructures has been evident, providing stable, well-defined frameworks for various constructions, including truss bridges, tower cranes, and electricity transmission line pylons. In the field of self-assembled nanocrystal superlattices, tetrahedral nanocrystals, as building blocks, occupy a unique place among all the possible nanoscale particles. Mathematical models, simulation work, and experimental studies using nanocrystals in the laboratory have suggested that self-assembled structures derived from nanoscale tetrahedral building blocks are notably intricate, giving rise to new horizons of high-entropy nanocrystal superlattices. An important implication from previous works is that such tetrahedral nanocrystal superlattices form through highly delicate interparticle interactions, emphasizing the importance of the fine features of these nanocrystals. In this article, we summarize the advances in superlattices assembled from tetrahedral nanocrystals. Here, we first define the tetrahedron and tetrahedron analogues based on Conway’s transformation and graph theory, underscoring their relevance to the crystallization process producing tetrahedral nanocrystals. Then, we showcase previous reports on the synthesis of tetrahedral nanocrystals and the resulting nanocrystal superstructures. Finally, we conclude by offering insights and perspective into the chemical and architectural intricacy that could emerge from tetrahedral nanocrystals.

Nanostructure↗

Long-run Marginal Emission Rates for Electricity - Workbooks for 2022 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States. A LRMER is an estimate of the rate of emissions that would be either induced or avoided by a change in electric demand, taking into account how the change could influence both the operation as well as the structure of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treat grid assets as fixed. Long-run marginal emissions rates are generally appropriate to use when trying to comprehensively estimate the impact of a long-lived (i.e., more than several years) intervention. There are two workbooks that supply the data at two different geographic resolutions: states and GEA regions (20 regions that are similar to, but not exactly the same as, the US EPA's eGRID regions). For more data underlying these emissions factors, see the Cambium 2022 project at https://scenarioviewer.nrel.gov/. For more details on input assumptions and methodology see the associated report (Cambium 2022 Scenario Descriptions and Documentation, https://www.nrel.gov/docs/fy23osti/84916.pdf). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

01 COAL, LIGNITE, AND PEAT↗

Long-run Marginal CO2 Emission Rates Workbooks for 2020 Standard Scenarios Cambium Data

This dataset has been superseded by a new set of workbooks that can be found here: https://data.nlr.gov/submissions/183 These workbooks contain modeled estimates of long-run marginal CO2 emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical demand. It incorporates both the projected changes to the electric grid, as well as the potential for an incremental change in electrical demand to influence the structural evolution of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treats grid assets as fixed. In addition to year-over-year data, the Levelized LRMER worksheet within each workbook is set up to produce a levelized long-run marginal emission rate based on user-provided inputs. These levelized LRMER values are intended for analysts to use when estimating the emissions induced (or avoided) by a long-term change in end-use electricity demand. Three future scenarios are provided in separate workbooks: A Mid-case (i.e., business-as-usual), and two scenarios with relatively higher or lower renewable energy costs. For more details on these scenarios, see the Standard Scenarios 2020 Report ( https://www.nlr.gov/docs/fy21osti/77442.pdf ). For more data underlying each scenario, see the Standard Scenarios 2020 project (Cambium data) at https://cambium.nlr.gov/ . This data was produced as part of the Cambium project. For more details about the methodology, see the Cambium Documentation: Version 2020 ( https://www.nlr.gov/docs/fy21osti/78239.pdf ). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nlr.gov/analysis/cambium.html .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-run Marginal Emission Rates for Electricity - Workbooks for 2021 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical demand. It incorporates both the projected changes to the electric grid, as well as the potential for an incremental change in electrical demand to influence the structural evolution of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treats grid assets as fixed. The Levelized LRMER worksheet within each workbook is set up to produce a levelized long-run marginal emission rate based on user-provided inputs. These levelized LRMER values are intended for analysts to use when estimating the emissions induced (or avoided) by a long-term change in end-use electricity demand. There are two workbooks that supply the data at two different geographic resolutions: states and GEA regions (20 regions that are similar to, but not exactly the same as, the US EPA's eGRID regions). For more data underlying these emissions factors, see the Cambium 2021 project at https://cambium.nrel.gov/. For more details on the inputs into the scenarios available in the workbooks, see the Standard Scenarios 2021 Report (https://www.nrel.gov/docs/fy22osti/80641.pdf). This data was produced as part of the Cambium project. For more details about the methodology, see the Cambium Documentation: Version 2021 (https://www.nrel.gov/docs/fy22osti/81611.pdf). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗