Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cartridge getter for vacuum jacketing

Inexpensively-manufactured getter cartridge save users time in vacuum system maintenance and allows almost anyone to carry out replacement procedure that formerly required skilled welder. Cartridge screws into port in outer wall of vacuum jacket. Getter is replaced by simply unscrewing cartridge rather than cutting and rewelding.

Luebbers, C. J.↗

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler↗

Commissioning of the Liquid Nitrogen Thermo-Siphon System for NASA-JSC Chamber-A

NASA's Space Environment Simulation Laboratory's (SESL) Chamber A, located at the Johnson Space Center in Houston Texas has recently implemented major enhancements of its cryogenic and vacuum systems. The new liquid nitrogen (LN2) thermo-siphon system was successfully commissioned in August of 2012. Chamber A, which has 20 K helium cryo-panels (or shrouds ) which are shielded by 80 K nitrogen shrouds, is capable of simulating a deep space environment necessary to perform ground testing of NASA s James Webb Space Telescope (JWST). Chamber A s previous system used forced flow LN2 cooling with centrifugal pumps, requiring 200,000 liters of LN2 to cool-down and consuming 180,000 liters per day of LN2 in steady operation. The LN2 system did not have the reliability required to meet the long duration test of the JWST, and the cost estimate provided in the initial approach to NASA-JSC by the sub-contractor for refurbishment of the system to meet the reliability goals was prohibitive. At NASA-JSC's request, the JLab Cryogenics Group provided alternative options in 2007, including a thermo-siphon, or natural flow system. This system, eliminated the need for pumps and used one tenth of the original control valves, relief valves, and burst disks. After the thermo-siphon approach was selected, JLab provided technical assistance in the process design, mechanical design, component specification development and commissioning oversight, while the installation and commissioning operations of the system was overseen by the Jacobs Technology/ESC group at JSC. The preliminary commissioning data indicate lower shroud temperatures, 70,000 liters to cool-down and less than 90,000 liters per day consumed in steady operation. All of the performance capabilities have exceeded the design goals. This paper will outline the comparison between the original system and the predicted results of the selected design option, and the commissioning results of thermo-siphon system.

Homan, J.↗

Adsorption of Water on JSC-1A Lunar Simulant Samples

Remote sensing probes sent to the moon in the 1990s indicated that water may exist in areas such as the bottoms of deep, permanently shadowed craters at the lunar poles, buried under regolith. Water is of paramount importance for any lunar exploration and colonization project which would require self-sustainable systems. Therefore, investigating the interaction of water with lunar regolith is pertinent to future exploration. The lunar environment can be approximated in ultra-high vacuum systems such as those used in thermal desorption spectroscopy (TDS). Questions about water dissociation, surface wetting, degree of crystallization, details of water-ice transitions, and cluster formation kinetics can be addressed by TDS. Lunar regolith specimens collected during the Apollo missions are still available though precious, so testing with simulant is required before applying to use lunar regolith samples. Hence, we used for these studies JSC-1a, mostly an aluminosilicate glass and basaltic material containing substantial amounts of plagioclase, some olivine and traces of other minerals. Objectives of this project include: 1) Manufacturing samples using as little raw material as possible, allowing the use of surface chemistry and kinetics tools to determine the feasibility of parallel studies on regolith, and 2) Characterizing the adsorption kinetics of water on the regolith simulant. This has implications for the probability of finding water on the moon and, if present, for recovery techniques. For condensed water films, complex TDS data were obtained containing multiple features, which are related to subtle rearrangements of the water adlayer. Results from JSC-1a TDS studies indicate: 1) Water dissociation on JSC-1a at low exposures, with features detected at temperatures as high as 450 K and 2) The formation of 3D water clusters and a rather porous condensed water film. It appears plausible that the sub- m sized particles act as nucleation centers.

Goering, John↗

Leak testing

Leak-testing methods for gas and liquid systems are described. The physical principles of molecular, liquid, and gas flow; relations of leak-testing methods and instrumentation; and tracer gases used in testing vacuum systems are discussed.

Engelhardt, R. E.↗

Cleaning of contaminated channel electron multiplier arrays.

Polymerized organic materials found in vacuum systems frequently contaminate the individual channels (which can be as small as 15 microns) of an oil-pumped channel electron multiplier array used as a vacuum UV- to visible-radiation conversion device. It is shown that exposure to an oxygen plasma is an effective means of decontaminating the channels, thereby restoring the sensitivity of the device.

Harlow, F. E.↗

Photolysis of spacecraft contaminants

A molecular beam facility, which was designed to measure photochemical cross-sections, has been constructed at the Athens College science facility. The integration of this vacuum system into an operational photochemical instrument was performed with signal processing consisting of both dc and ac techniques. Of the experiments performed to date on the vacuum ultraviolet photolysis of water vapor, it is apparent that a larger pumping capacity (preferably with differential pumping) is required to improve upon the background signal. Both phase-sensitive detection and ion-counting techniques are recommended for future studies.

Workman, G. L.↗

Space simulators for laser optics

Different approaches that are being utilized to test laser optical systems are described. One of the most crucial areas in the testing phase is the stability of the laser optics mounted inside the space simulator. The thermal vacuum system, the refrigeration system, and the space simulator are discussed.

Gardner, Frank H.↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

The molecular branching ratio method for calibration of optical systems in the vacuum ultraviolet

The intensity distribution of bands belonging to six molecular band systems is discussed with special emphasis on their usefulness for intensity calibration of optical systems in the vacuum ultraviolet (1000A Lambda 3000A). The theory of molecular band intensities is outlined and the technique of measuring the spectral response curve is described. Several methods for establishing an absolute intensity calibration are discussed.

Mumma, M. J.↗

Apollo telescope mount thermal systems unit thermal vacuum test

The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

Trucks, H. F.↗

Effects of Surface Treatments on the Outgassing of 3D-Printed 316L Stainless Steel.

Fermi National Accelerator Laboratory (Fermilab) is a world leader in designing and operating particle accelerators for nuclear and particle physics research. These accelerators rely on electric fields to propel particle beams, which are then directed and focused using magnetic fields. To ensure these beams travel without interference, they must move through an ultra-high vacuum environment, typically around 10⁻⁹ torr. Maintaining such a vacuum requires materials with exceptionally low outgassing rates. 316L stainless steel is a common material choice for vacuum systems due to its low outgassing rates, excellent corrosion resistance, non-magnetic properties, and high mechanical strength. When manufactured using traditional methods like machining, extrusion, and casting, the vacuum properties of 316L stainless steel are well understood. However, the behavior of 316L stainless steel produced through additive manufacturing, such as Direct Metal Laser Sintering (DMLS), is not as well documented. This study aims to determine the outgassing rate of 316L stainless steel fabricated using DMLS. The investigation focuses on measuring the outgassing rates of 1.5 2 vacuum reducers and evaluating the effects of surface preparation techniques, such as mechanical polishing and electropolishing, on the outgassing performance. Understanding the outgassing performance of 3D-printed 316L stainless steel could enable Fermilab engineers to adopt this fabrication method for producing complex parts designed for ultra-high vacuum environments. These advancements have the potential to benefit projects, such as the Long-Baseline Neutrino Facility (LBNF) and the Proton Improvement Plan-II (PIP-II), by improving design flexibility and fostering innovation in accelerator development.

Cloud, Jaiden [Central State University]↗

NASA Tech Briefs, April 2012

Topics include: Computational Ghost Imaging for Remote Sensing; Digital Architecture for a Trace Gas Sensor Platform; Dispersed Fringe Sensing Analysis - DFSA; Indium Tin Oxide Resistor-Based Nitric Oxide Microsensors; Gas Composition Sensing Using Carbon Nanotube Arrays; Sensor for Boundary Shear Stress in Fluid Flow; Model-Based Method for Sensor Validation; Qualification of Engineering Camera for Long-Duration Deep Space Missions; Remotely Powered Reconfigurable Receiver for Extreme Environment Sensing Platforms; Bump Bonding Using Metal-Coated Carbon Nanotubes; In Situ Mosaic Brightness Correction; Simplex GPS and InSAR Inversion Software; Virtual Machine Language 2.1; Multi-Scale Three-Dimensional Variational Data Assimilation System for Coastal Ocean Prediction; Pandora Operation and Analysis Software; Fabrication of a Cryogenic Bias Filter for Ultrasensitive Focal Plane; Processing of Nanosensors Using a Sacrificial Template Approach; High-Temperature Shape Memory Polymers; Modular Flooring System; Non-Toxic, Low-Freezing, Drop-In Replacement Heat Transfer Fluids; Materials That Enhance Efficiency and Radiation Resistance of Solar Cells; Low-Cost, Rugged High-Vacuum System; Static Gas-Charging Plug; Floating Oil-Spill Containment Device; Stemless Ball Valve; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Oxygen-Methane Thruster; Lunar Navigation Determination System - LaNDS; Launch Method for Kites in Low-Wind or No-Wind Conditions; Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications; Design and Performance of a Wideband Radio Telescope; Finite Element Models for Electron Beam Freeform Fabrication Process Autonomous Information Unit for Fine-Grain Data Access Control and Information Protection in a Net-Centric System; Vehicle Detection for RCTA/ANS (Autonomous Navigation System); Image Mapping and Visual Attention on the Sensory Ego-Sphere; HyDE Framework for Stochastic and Hybrid Model-Based Diagnosis; and IMAGESEER - IMAGEs for Education and Research.

Source record↗

Specifications of FIPD Fission Gas Release Data

All fission gas release data stored in the Fuels Irradiation & Physics Database (FIPD) was originally measured using the Gas Assay, Sample and Recharge (GASR) System in the Hot Fuel Examination Facility (HFEF). It is therefore called GASR data in FIPD. During the measurement of a sample, such as an irradiated EBR-II fuel element/capsule, a pinhole-sized region near the top of the element plenum was melted by a laser. Plenum gas then expanded into a calibrated volume (note: in this document, “sample” and “capsule/element” are used interchangeably consistent with GASR documents in FIPD). The pressure rise in the volume was recorded. Helium backfilling and expansion was then performed to determine the sample (e.g., fuel element plenum) volume using Boyle’s Law and assuming ideal gas behavior at constant temperature. With the plenum volume and the recorded pressure rise, the sample (e.g., fuel element plenum) pressure was derived with assumption of ideal gas law behavior. The plenum volume and pressure as well as the cladding temperature during the measurement were collected (GASR data in FIPD). Other records associated with the fission gas release data include: raw GASR data records including volumes and post-puncture pressures of seal head/sealing head and manifold, calibration data, backfilling gas pressure data, and the data analysis records. A sample(s) of the fission gas released from the plenum was collected by the GASR system into sample bottles. The chemical and isotopic composition of the gas sample was analyzed separately from GASR data, and will be discussed in a separate specification. The plenum volume, pressure, and cladding temperature during the measurement are typically utilized to determine the number of moles of gas in the plenum. This quantity is often compared to the number of moles of gas generated by fission events. However, calculating these values and their associated uncertainty is beyond the scope of this document, as it necessitates additional assumptions. The most important document to understand the FIPD fission gas data is the GASR operational manual (title: Gas Assay, Sample and Recharge System (GASR) operation and maintenance manual, HFEF/N OMM 4381, DOC. NO. W0018-0032-ES-00). This manual provides: (1) description of the GASR and the functions of each component (laser drilling, welding, seal head/sealing head, manifold, vacuum system, sample system, purge and gas tag system, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details relating to the structure and operation of the GASR. Note that the original GASR operated until 2020. A new GASR with the same design and measurement methodology was installed in 2021. The specifications of the GASR presented on the HFEF website at this time are consistent with the ones given in the operational manual. The methods to calculate the plenum volume and pressures were not included in the operational manual, but were recorded in the legacy data analysis files. Details of the methods are given in Chapter 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms

Documentation of the installation and use of venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms is presented. Information on the types of venturis that are useful for meeting the pumping requirements of atmospheric-sampling experiments is also presented. A description of the configuration and installation of the venturi system vacuum line is included with details on the modifications that were made to adapt a venturi to the NASA Electra aircraft at GSFC, Wallops Flight Facility. Flight test results are given for several venturis with emphasis on applications to the Differential Absorption Carbon Monoxide Measurement (DACOM) system at LaRC. This is a source document for atmospheric scientists interested in using the venturi systems installed on the NASA Electra or adapting the technology to other aircraft.

Hill, Gerald F.↗

Physical vapor deposition simulator by graphical processor unit ray casting

This paper presents fast, accurate software for modeling physical vapor deposition systems over irregular surfaces. The model is implemented using graphics processing unit (GPU) ray casting. Applied models are viewed as a cross section of the area of interest. Given evaporation rate, time, and angular profiles in a vacuum system, an iterative time-step approach for calculating deposition profiles is calculated in the GPU architecture following a ballistic modeling approach. Thin-film technologies for the electronics industry will require evaporations on complex surfaces. Depending on the nature of the surface, a uniform thin film across the topology is wanted for various device parameters. The ray casting method is tested against various profiles. The code is freely distributed on GitHub (see https://github.com/adam-r-thomas/PVDS).

Engineering↗

Interactions of amorphous Ta(x)Cu(1-x) (x = 0.93 and 0.80) alloy films with Au overlayers and GaAs substrates

Amorphous Ta(93)Cu(7) and Ta(80)Cu(20) alloy films are prepared by cosputtering of pure Ta and pure Cu targets with a rotating sample holder table. To investigate the possible application of these materials as diffusion barriers for the Au-GaAs system, vacuum annealings are made in the temperature range from 200 to 800 C. Resistivity change, X-ray diffraction, and Auger electron spectroscopy measurements are performed to find the chemical and metallurgical stabilities of these materials in this system. The reaction temperature for Ta(x)Cu(1-x) in contact with GaAs lies between 500 and 700 C. For Au in contact with Ta(x)Cu(1-x) the reaction occurs at about 600 C. Amorphous Ta(93)Cu(7) shows different interdiffusion characteristics with surrounding elements than does Ta(80)Cu(20).

Oh, Jae E.↗

Thruster Plume Plasma Diagnostics: A Ground Chamber Experiment for a 2-Kilowatt Arcjet

Although detailed near field (0 to 3 cm) information regarding the exhaust plume of a two kilowatt arc jet is available (refs. 1 to 6), there is virtually little or no information (outside of theoretical extrapolations) available concerning the far field (2.6 to 6.1 m). Furthermore real information about the plasma at distances between (3 to 6 m) is of critical importance to high technology satellite companies in understanding the effect of arc jet plume exhausts on space based power systems. It is therefore of utmost importance that one understands the exact nature of the interaction between the arc jet plume, the spacecraft power system and the surrounding electrical plasma environment. A good first step in understanding the nature of the interactions lies in making the needed plume parameter measurements in the far field. All diagnostic measurements are performed inside a large vacuum system (12 m diameter by 18 m high) with a full scale arc jet and solar array panel in the required flight configuration geometry. Thus, necessary information regarding the plume plasma parameters in the far field is obtained. Measurements of the floating potential, the plasma potential, the electron temperature, number density, density distribution, debye length, and plasma frequency are obtained at various locations about the array (at vertical distances from the arc jet nozzle: 2.6, 2.7, 2.8, 3.2, 3.6, 4.0, 4.9, 5.0, 5.4, 5.75, and 6.14 m). Plasma diagnostic parameters are measured for both the floating and grounded configurations of the arc jet anode and array. Spectroscopic optical measurements are then acquired in close proximity to the nozzle, and contamination measurements are made in the vicinity of the array utilizing a mass spectrometer and two Quartz Crystal Microbalances (QCM's).

Galofaro, Joel T.↗