Search NASA⌕ Search

SEARCH · Search NASA

Results for “variance reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Monte Carlo computed machine-specific correction factors for reference dosimetry of TomoTherapy static beam for several ion chambers

Purpose: To determine k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} correction factors for machine-specific reference (msr) conditions by Monte Carlo (MC) simulations for reference dosimetry of TomoTherapy static beams for ion chambers Exradin A1SL, A12; PTW 30006, 31010 Semiflex, 31014 PinPoint, 31018 microLion; NE 2571. Methods: For the calibration of TomoTherapy units, reference conditions specified in current codes of practice like IAEA/TRS-398 and AAPM/TG-51 cannot be realized. To cope with this issue, Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] described a new formalism introducing msr factors k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} for reference dosimetry, applicable to static TomoTherapy beams. In this study, those factors were computed directly using MC simulations for Q{sub 0} corresponding to a simplified {sup 60}Co beam in TRS-398 reference conditions (at 10 cm depth). The msr conditions were a 10 Multiplication-Sign 5 cm{sup 2} TomoTherapy beam, source-surface distance of 85 cm and 10 cm depth. The chambers were modeled according to technical drawings using the egs++ package and the MC simulations were run with the egs{sub c}hamber user code. Phase-space files used as the source input were produced using PENELOPE after simulation of a simplified {sup 60}Co beam and the TomoTherapy treatment head modeled according to technical drawings. Correlated sampling, intermediate phase-space storage, and photon cross-section enhancement variance reduction techniques were used. The simulations were stopped when the combined standard uncertainty was below 0.2%. Results: Computed k{sub Q{sub m{sub s{sub r,Q{sub o}{sup f{sub m}{sub s}{sub r},f{sub o}}}}}} values were all close to one, in a range from 0.991 for the PinPoint chamber to 1.000 for the Exradin A12 with a statistical uncertainty below 0.2%. Considering a beam quality Q defined as the TPR{sub 20,10} for a 6 MV Elekta photon beam (0.661), the additional correction k{sub Q{sub m{sub s{sub r{sub ,Q}{sup f{sub m}{sub s}{sub r}{sub ,}f{sub r}{sub e}{sub f}}}}}} to k{sub Q,Q{sub o}} defined in Alfonso et al. [Med. Phys. 35, 5179-5186 (2008)] formalism was in a range from 0.997 to 1.004.Conclusion: The MC computed factors in this study are in agreement with measured factors for chamber types already studied in literature. This work provides msr correction factors for additional chambers used in reference dosimetry. All of them were close to one (within 1%).

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficacy of fixed filtration for rapid kVp-switching dual energy x-ray systems

Purpose: Dose efficiency of dual kVp imaging can be improved if the two beams are filtered to remove photons in the common part of their spectra, thereby increasing spectral separation. While there are a number of advantages to rapid kVp-switching for dual energy, it may not be feasible to have two different filters for the two spectra. Therefore, the authors are interested in whether a fixed added filter can improve the dose efficiency of kVp-switching dual energy x-ray systems. Methods: The authors hypothesized that a K-edge filter would provide the energy selectivity needed to remove overlap of the spectra and hence increase the precision of material separation at constant dose. Preliminary simulations were done using calcium and water basis materials and 80 and 140 kVp x-ray spectra. Precision of the decomposition was evaluated based on the propagation of the Poisson noise through the decomposition function. Considering availability and cost, the authors chose a commercial Gd{sub 2}O{sub 2}S screen as the filter for their experimental validation. Experiments were conducted on a table-top system using a phantom with various thicknesses of acrylic and copper and 70 and 125 kVp x-ray spectra. The authors kept the phantom exposure roughly constant with and without filtration by adjusting the tube current. The filtered and unfiltered raw data of both low and high energy were decomposed into basis material and the variance of the decomposition for each thickness pair was calculated. To evaluate the filtration performance, the authors measured the ratio of material decomposition variance with and without filtration. Results: Simulation results show that the ideal filter material depends on the object composition and thickness, and ranges across the lanthanide series, with higher atomic number filters being preferred for more attenuating objects. Variance reduction increases with filter thickness, and substantial reductions (40%) can be achieved with a 2× loss in intensity. The authors’ experimental results validate the simulations, yet were overall slightly worse than expectation. For large objects, conventional (non-K-edge) beam hardening filters perform well. Conclusions: This study demonstrates the potential of fixed K-edge filtration to improve the dose efficiency and material decomposition precision for rapid kVp-switching dual energy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing cone beam CT scatter estimation in egs-cbct for a clinical and virtual chest phantom

Purpose: Cone beam computed tomography (CBCT) image quality suffers from contamination from scattered photons in the projection images. Monte Carlo simulations are a powerful tool to investigate the properties of scattered photons.egs-cbct, a recent EGSnrc user code, provides the ability of performing fast scatter calculations in CBCT projection images. This paper investigates how optimization of user inputs can provide the most efficient scatter calculations. Methods: Two simulation geometries with two different x-ray sources were simulated, while the user input parameters for the efficiency improving techniques (EITs) implemented inegs-cbct were varied. Simulation efficiencies were compared to analog simulations performed without using any EITs. Resulting scatter distributions were confirmed unbiased against the analog simulations. Results: The optimal EIT parameter selection depends on the simulation geometry and x-ray source. Forced detection improved the scatter calculation efficiency by 80%. Delta transport improved calculation efficiency by a further 34%, while particle splitting combined with Russian roulette improved the efficiency by a factor of 45 or more. Combining these variance reduction techniques with a built-in denoising algorithm, efficiency improvements of 4 orders of magnitude were achieved. Conclusions: Using the built-in EITs inegs-cbct can improve scatter calculation efficiencies by more than 4 orders of magnitude. To achieve this, the user must optimize the input parameters to the specific simulation geometry. Realizing the full potential of the denoising algorithm requires keeping the statistical uncertainty below a threshold value above which the efficiency drops exponentially.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-108: Development of a Novel Clinical Neutron Dose Monitor for Proton Therapy Based On Twin TLD500 Chips in a Small PE Moderator

Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:C (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-602: Beryllium Seeds Implant for Photo-Neutron Yield Using External Beam Therapy

Purpose: To evaluate the Neutron yield obtained during prostate external beam irradiation. Methods: Neutrons, that are commonly a radiation safety concern for photon beams with energy above 10 MV, are induced inside a PTV from Beryllium implemented seeds. A high megavoltage photon beam delivered to a prostate will yield neutrons via the reaction Be-9(γ,n)2?. Beryllium was chosen for its low gamma,n reaction cross-section threshold (1.67 MeV) to be combined with a high feasible 25 MV photon beam. This beam spectra has a most probable photon energy of 2.5 to 3.0 MeV and an average photon energy of about 5.8 MeV. For this feasibility study we simulated a Beryllium-made common seed dimension (0.1 cm diameter and 0.5 cm height) without taking into account encapsulation. We created a 0.5 cm grid loading pattern excluding the Urethra, using Variseed (Varian inc.) A total of 156 seeds were exported to a 4cm diameter prostate sphere, created in Fluka, a particle transport Monte Carlo Code. Two opposed 25 MV beams were simulated. The evaluation of the neutron dose was done by adjusting the simulated photon dose to a common prostate delivery (e.g. 7560 cGy in 42 fractions) and finding the corresponding neutron dose yield from the simulation. A variance reduction technique was conducted for the neutrons yield and transported. Results: An effective dose of 3.65 cGy due to neutrons was found in the prostate volume. The dose to central areas of the prostate was found to be about 10 cGy. Conclusion: The neutron dose yielded does not justify a clinical implant of Beryllium seeds. Nevertheless, one should investigate the Neutron dose obtained when a larger Beryllium loading is combined with commercially available 40 MeV Linacs.

07 ISOTOPE AND RADIATION SOURCES↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

GMctdospp: Description and validation of a CT dose calculation system

Purpose: To develop a Monte Carlo (MC)-based computed tomography (CT) dose estimation method with a graphical user interface with options to define almost arbitrary simulation scenarios, to make calculations sufficiently fast for comfortable handling, and to make the software free of charge for general availability to the scientific community. Methods: A framework called GMctdospp was developed to calculate phantom and patient doses with the MC method based on the EGSnrc system. A CT scanner was modeled for testing and was adapted to half-value layer, beam-shaping filter, z-profile, and tube-current modulation (TCM). To validate the implemented variance reduction techniques, depth-dose and cross-profile calculations of a static beam were compared against DOSXYZnrc/EGSnrc. Measurements for beam energies of 80 and 120 kVp at several positions of a CT dose-index (CTDI) standard phantom were compared against calculations of the created CT model. Finally, the efficiency of the adapted code was benchmarked against EGSnrc defaults. Results: The CT scanner could be modeled accurately. The developed TCM scheme was confirmed by the dose measurement. A comparison of calculations to DOSXYZnrc showed no systematic differences. Measurements in a CTDI phantom could be reproduced within 2% average, with a maximal difference of about 6%. Efficiency improvements of about six orders of magnitude were observed for larger organ structures of a chest-examination protocol in a voxelized phantom. In these cases, simulations took 25 s to achieve a statistical uncertainty of ∼0.5%. Conclusions: A fast dose-calculation system for phantoms and patients in a CT examination was developed, successfully validated, and benchmarked. Influences of scan protocols, protection method, and other issues can be easily examined with the developed framework.

60 APPLIED LIFE SCIENCES↗

SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

TH-CD-201-02: A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator

Purpose: Direct measurement of the energy spectrum of a 6MV linear accelerator has not been successful due to the high fluence rate, high energy nature of these photon beams. Previous work used a Compton Scattering (CS) spectrometry setup with a shielded spectrometer for spectrum measurements. Despite substantial lead shielding, excessive pulse pile-up was seen. MCNP6 transport code was used to investigate the feasibility and effectiveness of performing measurements using a novel detector setup. Methods: Simulations were performed with a shielded high-purity germanium (HPGe) semiconductor detector placed in the accelerator vault’s maze, with a 2 cm diameter collimator through a 92 cm thick concrete wall. The detector was positioned 660 cm from a scattering rod (placed at isocenter) at an angle of 45° relative to the central axis. This setup was compared with the shielded detector positioned in the room, 200 cm from the scattering rod at the same CS angle. Simulations were used to determine fluence contributions from three sources: (1) CS photons traveling through the collimator aperture, the intended signal, (2) CS scatter photons penetrating the detector shield, and (3) room-scattered photons penetrating the detector shield. Variance reduction techniques including weight windows, DXTRAN spheres, forced collisions, and energy cutoffs were used. Results: Simulations showed that the number of pulses per starting particle from an F8 detector tally for the intended signal decreased by a factor of 10{sup 2} when moving the detector out of the vault. This reduction in signal was amplified for the unwanted scatter signal which decreased by up to a factor of 10{sup 9}. Conclusion: This work used MCNP6 to show that using a vault wall to shield unwanted scatter and increasing isocenter-to-detector distance reduces unwanted fluence to the detector. This study aimed to provide motivation for future experimental work using the proposed setup.

07 ISOTOPE AND RADIATION SOURCES↗

Probing for the Trace Estimation of a Permuted Matrix Inverse Corresponding to a Lattice Displacement

We report thatpProbing is a general technique that is used to reduce the variance of the Hutchinson stochastic estimator for the trace of the inverse of a large, sparse matrix A. The variance of the estimator is the sum of the squares of the off-diagonal elements of A -1 . Therefore, this technique computes probing vectors that when used in the estimator annihilate the largest off-diagonal elements. For matrices that display decay of the magnitude of |A$^{-1}_{ij}$| with the graph distance between nodes i and j, this is achieved through graph coloring of increasing powers A k . Equivalently, when a matrix stems from a lattice discretization, it is computationally beneficial to find a distance-k coloring of the lattice. Previously, a hierarchical coloring was proposed so that k can be increased at runtime as needed without discarding previous work. In this work, we study probing for the more general problem of computing the trace of a permutation of A -1 , say PA -1 . The motivation comes from lattice quantum chromodynamics (QCD), where we need to construct “disconnected diagrams” to extract flavor-separated generalized parton functions. In lattice QCD, where the matrix has a four-dimensional toroidal lattice structure, these nonlocal operators correspond to a PA -1 , where P is the permutation relating to some displacement $\vec{p}$ in one or more dimensions. We focus on a single dimension displacement (p), but our methods are general. We show that probing on A k or (PA) k does not annihilate the largest magnitude elements. To resolve this issue, our displacement-based probing works on PA k using a new coloring scheme that works directly on appropriately displaced neighborhoods on the lattice. We prove lower bounds on the number of colors needed and study the effect of this scheme on variance reduction, both theoretically and experimentally on a real-world lattice QCD calculation. We achieve orders of magnitude speedup over the unprobed or the naively probed methods.

97 MATHEMATICS AND COMPUTING↗

Weak-Form Latent Space Dynamics Identification

This software showcases the enhanced capabilities of the Latent Space Dynamics Identification (LaSDI) algorithm through the application of the weak form, resulting in WLaSDI. WLaSDI first compresses the data, then projects it onto test functions, and subsequently learns the local latent space models. Notably, WLaSDI demonstrates significantly improved robustness to noise. Using weak-form equation learning techniques, WLaSDI achieves local latent space modeling. Compared to the standard sparse identification of nonlinear dynamics (SINDy) used in LaSDI, the variance reduction of the weak form ensures robust and precise latent space recovery, enabling fast, robust, and accurate simulations. We demonstrate the efficacy of WLaSDI against LaSDI using several common benchmark examples, including viscid and inviscid Burgers', radial advection, and heat conduction. For instance, in 1D inviscid Burgers' simulations with up to 100% Gaussian white noise, WLaSDI maintains relative errors consistently below 6%, whereas LaSDI errors can exceed 10,000%. Similarly, in radial advection simulations, WLaSDI keeps relative errors below 16%, compared to potential errors of up to 10,000% with LaSDI. Additionally, WLaSDI achieves significant speedups, such as a 140X speedup in 1D Burgers' simulations compared to the corresponding full order model.

Choi, Youngsoo↗

CV4Quantum

CV4Quantum is a statistical technique for reducing the sampling overhead in probabilistic error cancellation, which is an error mitigation technique used in quantum computing. CV4Quantum is based on the control variates method, which is a Monte Carlo variance reduction technique. This repository contains the code and data associated with a demonstration of CV4Quantum using simulation experiments.

Shyamsundar, Prasanth [Fermi National Accelerator ↗

Shutdown Dose Rate Analysis Using the Multi-Step CADIS Method

The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid Monte Carlo (MC)/deterministic radiation transport method was proposed to speed up the shutdown dose rate (SDDR) neutron MC calculation using an importance function that represents the neutron importance to the final SDDR. This work applied the MS-CADIS method to the ITER SDDR benchmark problem. The MS-CADIS method was also used to calculate the SDDR uncertainty resulting from uncertainties in the MC neutron calculation and to determine the degree of undersampling in SDDR calculations because of the limited ability of the MC method to tally detailed spatial and energy distributions. The analysis that used the ITER benchmark problem compared the efficiency of the MS-CADIS method to the traditional approach of using global MC variance reduction techniques for speeding up SDDR neutron MC calculation. Compared to the standard Forward-Weighted-CADIS (FW-CADIS) method, the MS-CADIS method increased the efficiency of the SDDR neutron MC calculation by 69%. The MS-CADIS method also increased the fraction of nonzero scoring mesh tally elements in the space-energy regions of high importance to the final SDDR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

The Oak Ridge National Laboratory (ORNL) Second Target Station (STS) neutron production facility is an accelerator driven pulsed neutron source that is currently being actively developed at ORNL. The neutrons are produced by proton-induced spallation reactions. A proton beam of 700 kW power is delivered to a spallation target in short, less than 1 µs long pulses, with 15 Hz repetition rate. The spallation target of ORNL STS is a rotating water-cooled tungsten target with tantalum cladding housed in a stainless-steel shroud. It is divided into 21 segments. These segments become highly activated due to spallation reactions or nuclei transmutation by the emitted neutrons. The radioactive nuclides continue to decay after ceasing operation. The decay dose rates generated from the target segments once they are removed from their operational location within the core vessel must be accurately quantified to determine the shielding configurations of remote handling tools and transport casks and to aid in planning maintenance events. To determine the shielding configurations needed for an activated target segment after ceasing operation, both the hybrid unstructured mesh (UM)/constructive solid geometry (CSG) approach that was previously utilized for STS analyses [1] and the ADVANTG code [2] were used. Even though the ADVANTG code does not include UM capability, the utilization of its advanced variance reduction technique was crucial to accelerate the extremely difficult final photon transport calculation in this analysis. This paper also describes the procedures taken to mitigate the convergence issues that occur when ADVANTG uses a source definition that does not match the source of the final Monte Carlo (MC) calculation. These convergence issues often occur because of inconsistencies between source and transport biasing parameters.

Ibrahim, Ahmad↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

SCALE 6: Comprehensive Nuclear Safety Analysis Code System

Version 6 of the Standardized Computer Analyses for Licensing Evaluation (SCALE) computer software system developed at Oak Ridge National Laboratory, released in February 2009, contains significant new capabilities and data for nuclear safety analysis and marks an important update for this software package, which is used worldwide. This paper highlights the capabilities of the SCALE system, including continuous-energy flux calculations for processing multigroup problem-dependent cross sections, ENDF/B-VII continuous-energy and multigroup nuclear cross-section data, continuous-energy Monte Carlo criticality safety calculations, Monte Carlo radiation shielding analyses with automated three-dimensional variance reduction techniques, one- and three-dimensional sensitivity and uncertainty analyses for criticality safety evaluations, two- and three-dimensional lattice physics depletion analyses, fast and accurate source terms and decay heat calculations, automated burnup credit analyses with loading curve search, and integrated three-dimensional criticality accident alarm system analyses using coupled Monte Carlo criticality and shielding calculations.

99 GENERAL AND MISCELLANEOUS↗

Biological shield design and analysis of KIPT accelerator-driven subcritical facility.

Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology of Ukraine have been collaborating on the conceptual design development of an electron accelerator-driven subcritical facility. The facility will be utilized for performing basic and applied nuclear research, producing medical isotopes, and training young nuclear specialists. This paper presents the design and analyses of the biological shield performed for the top section of the facility. The neutron source driving the subcritical assembly is generated from the interaction of a 100-kW electron beam with a natural uranium target. The electron energy is in the range of 100 to 200 MeV, and it has a uniform spatial distribution. The shield design and the associated analyses are presented including different parametric studies. In the analyses, a significant effort was dedicated to the accurate prediction of the radiation dose outside the shield boundary as a function of the shield thickness without geometrical approximations or material homogenization. The MCNPX Monte Carlo code was utilized for the transport calculation of electrons, photons, and neutrons. Weight window variance-reduction techniques were introduced, and the dose equivalent outside the shield can be calculated with reasonably good statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗