Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Auto-BLAST (AutoBLAST) [SWR-20-93]

Battery life modeling often involves a lot of manual parameter fitting and is not easy for users to adopt the model and use it. To reduce the difficulties for users to adopt battery lifetime models, an automatic battery lifetime modeling analysis and simulation tool suite, Auto-BLAST, has been developed. Auto-BLAST includes a lithium-loss-base life model, a battery electric model, and an algorithm which automatically fits all key parameters in the electric and life models using user provided data. The models and algorithm are packaged into two user-friendly GUIs, Auto-LifeMod, for easy battery life prognostic model fitting and Auto-LifeSim, for easy battery lifetime simulation. The lithium-loss-based life model adopts a similar model framework that models degradations using aging rate models, using battery cycling data to predict battery degradation and expected lifetime. The electric model is an equivalent circuit model which simulates battery voltage responses based on current/power demand profiles. The auto-fitting algorithm uses the user-input data to generate custom battery life model(s). Two GUIs, wrapping around the life model and the auto-fitting algorithm, provide friendly interfaces for users to generate a life model and use it for case study. One GUI requires summary data from accelerated battery life degradation tests as an input and produces battery life models predicting (a) capacity degradation, and (b) resistance growth of the battery. The GUI displays the electrical model response and the input experimental data against the life model predictions with fitted model parameters and fitting error. The GUI also generates an output file to save the fitted model parameters. The second GUI uses the life model from the first GUI and a user-defined battery cycling profile to predict battery lifetime degradation and expected lifetime. Predicted capacity and resistance vs. time are plotted in the GUI and saved to output file. There is a user guide for both GUIs

Mishra, Partha↗

Power Systems Evaluated for Solar Electric Propulsion Vehicles

Solar electric propulsion (SEP) mission architectures are applicable to a wide range NASA missions including the robotic exploration of the outer planets in the next decade and the human exploration of Mars within the next 2 decades. SEP enables architectures that are very mass efficient with reasonable power levels (1-MW class) aerobrake and cryogenic upper-stage transportation technologies are utilized. In this architecture, the efficient SEP stage transfers the payload from low Earth orbit (LEO) High Energy Elliptical Parking Orbit (HEEPO) within a period of 6 to 12 months. highthrust, cryogenic upper stage and payload then separate from the SEP vehicle for injection to the planetary target, allowing for fast heliocentric trip times. This mission architecture offers a potential reduction in mass to LEO in comparison to alternative all-chemical nuclear propulsion schemes. Mass reductions may allow launch vehicle downsizing enable missions that would have been grounded because of cost constraints. The preceding figure illustrates a conceptual SEP stage design for a human Mars mission. Researchers at the NASA Glenn Research Center at Lewis Field designed conceptual SEP vehicle, conceived the mission architecture to use this vehicle, and analyzed the vehicle s performance. This SEP stage has a dry mass of 35 metric tons (MT), 40 MT of xenon propellant, and a photovoltaic array that spans 110 m, providing power to a cluster of eight 100-kW Hall thrusters. The stage can transfer an 80-MT payload and upper stage to the desired HEEPO. Preliminary packaging studies show this space-station-class SEP vehicle meets the proposed "Magnum" launch vehicle and volume requirements with considerable margin. An SEP vehicle for outer planetary missions, such as the Europa Mapper Mission, would be dramatically smaller than human Mars mission SEP stage. In this mission architecture, the SEP power system with the payload to provide spacecraft power throughout the mission. Several photovoltaic array design concepts were considered for the SEP vehicle power system for the human mission to Mars. These include a space station derivative, a SCARLET (Solar Concentrator Arrays with Refractive Linear Element Technology) derivative, and a hybrid inflatable-deployable thin polymer membrane array with thin-film solar cells (as shown in the concept illustration). This concept is based on a design developed for the Next Generation Space Telescope Sun shield. The array is divided into 16 independent electrical sections with 500-V, negative-grounded solar cell strings. The power system employs a channelized, 500-Vdc power management and distribution (PMAD) architecture with lithium ion batteries for energy storage for vehicle and payload secondary loads (the high-power Hall thrusters do not operate in eclipse periods). The 500-V PMAD voltage permits "direct-drive" thruster operation, greatly reducing the power processing unit size, complexity, and power loss. Similar power system architecture, designs, and technology are assumed for the Europa Mapper Mission SEP vehicle. The primary exceptions are that the photovoltaic array is assumed to consist of two rectangular wings and that the power system rating is 15 kW in Earth orbit and 200 W at Europa. To size the SEP vehicle power system, a dedicated Fortran code was developed to predict detailed power system performance, mass, and thermal control requirements. This code also modeled all the relevant Earth orbit environments; that is, the particulate radiation, plasma, meteoroids and debris, ultraviolet radiation, contamination, and thermal conditions. Analysis results for the Human Mars Mission SEP vehicle show a power system mass of 9-MT and photovoltaic array area of 5800-square meters for the thin-membrane design concept with CuInS2 thin-film cells. Power processing unit input power for a thin-membrane array design with three-junction, amorphous SiGe solar cells is shown in the graph. Power falls off rapidly inhe first weeks of the mission because of light-induced (Staebler-Wronksi) solar cell losses. During the next 200 days, power decreases steadily as the SEP stage spirals through the proton belts and sustains the bulk of the mission radiation damage. Once the vehicle apogee is above approximately four Earth radii, little additional degradation is incurred. From 400 to 800 days, a 1100-km "parking" orbit is maintained to await the next payload transfer opportunity. This orbit is below the main proton belt, and thus, little radiation dose is accumulated during this time period. During the second LEO-to-HEEPO transfer, power degrades somewhat further, but power requirements are still met. In comparison, the Europa Mapper SEP vehicle power system had a mass of 150 kg and a thin membrane array area of 100 square meters.

Kerslake, Thomas W.↗

Evaluating the Feasibility of Transactive Approach for Voltage Management Using Inverters of a PV Plant

This article evaluates the feasibility of a double-auction-based Transactive Energy System (TES) for engaging the reactive power (Var) capability of inverters in a utility-scale pho¬tovoltaic (PV) plant for voltage management in distribution feed¬ers. In this approach, a PV plant owner (seller) provides Var supply curves in terms of price-quantity pairs consider¬ing the inverters’ P-Q capability, efficiency, opportunity cost for real power curtail¬ment, losses, etc. At the same time, the utility (buyer) proposes Var demand curves in price-quantity pairs exhibiting the marginal price of Var. Then, market clearing points are obtained from the intersection points of supply and demand curves which are then used to create Var dispatch sig-nals from the PV plant. To conduct a fea¬sibility study of this approach, an Australian distribution network with a utility-scale PV plant (capacity 3.275 MWP) is modeled in RSCAD and simu¬lated in real-time on MATLAB, RSCAD-RTDS co-simulation platform using real historical data. Consid¬ering a use case, namely, conservation voltage reduction (CVR), the operational feasibility along with cost-benefit analysis is demonstrated in software-in-the-loop (SIL) and hardware-in-the-loop (HIL) platform. Another use case, exploring the benefit from tap-change reduction of step-voltage-regulator, is investigated. These studies explore further use cases, e.g., PV hosting capacity, network reconfiguration, etc., to be incorporated in TES for experiencing substantial economic benefits.

Alam, Mollah Rezaul↗

Control of multiple resonant power processors in a multi-source system

Analysis and test results show that phasor-regulated, Mapham-derived resonant inverters can be paralleled to provide standardizing interfaces for multiple sources on a utility-type, aerospace power distribution bus. The basic sources do not require matching in any way, and may have grossly different characteristics. Fully stable system architectures with multiple sources, parallel/redundant distribution buses, and a wide variety of loads can be easily constructed and controlled. The commands and parameters available for system control allow for tight tolerance bus voltage control, and absolute power-sharing control from the various sources over the full range of possible source and load variations. That level of control enables simplified load power processing hardware and the distribution of losses to optimally load the source thermal control system. Positive control of all system performance and allocation of losses are not required by all missions or vehicles, and overall vehicle considerations do not always require the loads on vehicle energy sources and thermal control systems to be balanced. In those cases, power system control can be simplified, and a hierarchical set of defaults can be substituted for computer-generated or supervisory input commands to allow for stable, fully autonomous system operation.

Mildice, James↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Operando Bragg Coherent Diffraction Imaging of LiNi 0.8 Mn 0.1 Co 0.1 O 2 Primary Particles within Commercially Printed NMC811 Electrode Sheets

Due to complex degradation mechanisms, disparities between the theoretical and practical capacities of lithium-ion battery cathode materials persist. Specifically, Ni-rich chemistries such as LiNi 0.8 Mn 0.1 Co 0.1 O 2 (or NMC811) are one of the most promising choices for automotive applications; however, they continue to suffer severe degradation during operation that is poorly understood, thus challenging to mitigate. Here in this paper we use operando Bragg coherent diffraction imaging for 4D analysis of these mechanisms by inspecting the individual crystals within primary particles at various states of charge (SoC). Although some crystals were relatively homogeneous, we consistently observed non-uniform distributions of inter- and intracrystal strain at all measured SoC. Pristine structures may already possess heterogeneities capable of triggering crystal splitting and subsequently particle cracking. During low-voltage charging (2.7–3.5 V), crystal splitting may still occur even during minimal bulk deintercalation activity; and during discharging, rotational effects within parallel domains appear to be the precursor for the nucleation of screw dislocations at the crystal core. Ultimately, this discovery of the central role of crystal grain splitting in the charge/discharge dynamics may have ramifications across length scales that affect macroscopic performance loss during real-world battery operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural Passivation of Patterned Al 2 O 3 Back Contacts on CdS/CdTe Solar Cells

Abstract Patterned aluminum oxide (Al 2 O 3 ) back contact on cadmium telluride (CdTe) solar cells can effectively mitigate the loss of the majority carriers while retaining the passivation benefits for minority carriers. This study investigates the impact of the point‐contact geometry on cell performance, where the spacing of the microholes is systematically varied at a constant microhole diameter (≈16 µm). Microhole arrays are created on an evaporated Al 2 O 3 layer (≈30 nm) on CdTe using laser‐beam lithography and selective wet etching processes. Comparative analysis indicates a significant decrease in fill factor (FF) and short‐circuit current ( I SC ) when the contact fraction falls below 30%, likely due to the Al 2 O 3 barrier impeding majority carriers. Above this fraction, FF and I SC are comparable to those of baseline CdTe cells without Al 2 O 3 . Open‐circuit voltage ( V OC ) shows a gradual decrease as Al 2 O 3 coverage is reduced but exhibits a slight increase (<15 mV) when the contact fraction exceeds 30%. Cathodoluminescence (CL) characterization reveals that significantly improved radiative recombination occurs within the CdTe grain bulk with Al 2 O 3 , whereas this effect on grain boundaries is minimal. The findings imply complex local carrier dynamics in the patterned back‐contact region, closely tied to the microstructural properties of CdTe‐based solar cells.

Roy, Etee Kawna↗

Difluorophosphoric Acid Generation and Crossover Reactions in LiNixCoyMnzO 2 Cathodes Operating at High Voltage

Cycling lithiated metal oxides to high potential (>4.5 V vs Li) is of significant interest for the next generation of lithium ion batteries as this significantly increases the capacity and energy of cells. However, cells cycled to high potential suffer from rapid capacity fade due to a combination of thickening of the anode solid electrolyte interphase (SEI) and impedance growth on the cathode. While transition metal catalysed degradation of the anode SEI has been widely proposed as a primary source of capacity loss, a related acid induced degradation of the anode SEI is proposed. A systematic investigation of LiNi 0.5 Co 0.2 Mn 0.3 O 2 , and LiNi 0.8 Co 0.1 Mn 0.1 O 2 cathodes cycled to 4.2 and 4.6 V has been conducted and the oxidative generation of the strong acid difluorophosphoric acid (F 2 PO 2 H) has been quantified by solution Nuclear Magnetic Resonance (NMR) spectroscopy. Ex-situ surface analysis of the electrodes with X-ray Photo Electron spectroscopy (XPS) suggests that the generation of F 2 PO 2 H correlates with a thickening of the anode SEI and an increase in the fluorophosphate content of the SEI. Changes to the LiNi 0.8 Co 0.1 Mn 0.1 O 2 surface for cells cycled to 4.6 V are also consistent with the generation of acidic species. There is good correlation between the concentration F 2 PO 2 H, anode SEI degradation and the capacity loss of the cells.

25 ENERGY STORAGE↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Analysis of PV Fleet Performance in Western United States During August 2020 Extreme Heat Wave

Starting in June 2020 through the end of that year, the western and central United States experienced a widespread heat wave and drought, which resulted in US$5.44 billion (CPI-adjusted) worth of damages. The ongoing heat and drought produced record large wildfires across the region, responsible for an additional US$19.9 billion in damage. These natural disasters directly impacted the energy system in the western US, leading to power blackouts in August 2020. In this work, we analyze the NLR PV Fleets data set, focusing on the geographic area covered by the Western Coordinating Council (WECC). We find that over the 10-day period from August 14 through 24, the median PV system produced 12% lower energy than expected, with some locations experiencing total losses of around 30%. Analyzing the spatial-temporal structure of the data and supplementing with limited operational current and voltage data where available, we find that system underperformance was more strongly impacted by irradiance reduction from wildfire smoke rather than by the high heat itself.

14 SOLAR ENERGY↗

CalTestBed - Delphire - Testing and Evaluation of Delphire Sentinel System (CRADA Final Report)

The Delphire Sentinel is a modular fire detection and communications system operating as a mobile field unit, with low voltage DC power supplied by onboard photovoltaics (PV) and batteries. The Sentinel addresses several aspects of fire detection, communications and data analysis. The Sentinel's mobility enables it to be rapidly deployed and operate independently of existing power and communications networks. The duration of independent operation depends critically on the energy consumption of the systems and performance of the onboard PV and battery. The purpose of this testing is to ascertain the power draw and energy consumption of the Delphire Sentinel prototype system under several operational states, including various data transfer packet sizes, transmission time and frequencies, and communication pathways (Wi-Fi, cellular, satellite) expected to be encountered in field deployments. It will also include procedures to test the ability of the Sentinel to operate for extended periods without loss of functionality. Based on results from energy and power measurements, and anticipated duty cycles in field deployments, we will model annual system autonomy (e.g. loss of load probability) for off-grid operation in representative locations.

47 OTHER INSTRUMENTATION↗

Battery state-of-health diagnostics during fast cycling using physics-informed deep-learning

Rapid, in-situ Li-ion battery state-of-health (SOH) quantification is challenging. Li-ion battery aging can vary significantly with chemistry, operating conditions, cycling demands, electrode design, and operation history. As a cell ages, optimal and safe operating conditions need to be adapted to account for battery degradation by tracking critical aging modes such as loss-of-lithium-inventory (LLI), loss-of-active-material (LAM) in either electrode, and/or impedance rise. This manuscript describes a framework for identifying battery aging modes in-operando using fast-rate voltage charge/discharge responses. The framework uses a physically based Li-ion battery model to produce synthetic high-rate responses at aged states. The aging model is calibrated against experimental data from cells with different electrode loadings and cycled under a variety of fast-charging conditions (1 h, 15 min, 10 min, and 7 min charging). The synthetically generated high-rate responses at aged states are then used to train a deep-learning model to identify real cell state-of-health from fast charge/discharge battery voltage responses. The synthetically trained deep-learning model performance is validated by comparing to standard incremental capacity analysis and half-cell measurements. Finally, the framework demonstrates the benefits of using high-rate physics-based models to generate synthetic data for training deep-learning models.

25 ENERGY STORAGE↗

Applications of Anabolic Vitamin D Analogs as Countermeasures to Bone Loss

The experiments in Round 2 were designed to extend the results of our efforts in Round 1 which led us to hypothesize that the seco-steroid, 1,25-dihydroxyvitamin D3[1,25(OH)2D3], acts in synergy with parathyroid hormone (PTH) to regulate bone calcium homeostasis. Our work centered on one particular target of 1,25(OH)2D3 action, the voltage-sensitive calcium channels (VSCC's), which are activated acutely by this steroid within milliseconds of exposure . A second area of research focused on the effects of mechanical strain on VSCC expression in bone. These experiments were performed in collaboration with Dr. Steven Goldstein (Univ. Michigan), who generously provided RNA extracted from dog bones that had been exposed to mechanical strain in vivo. Our results suggest that mechanical loading elevated VSCC expression in the long bones from 3 of the 6 animals tested. A second line of experimentation, carried out in collaboration with Dr. Randall Duncan, a NASA-funded investigator in Indianapolis, centered on RT-PCR analysis of effects of mechanical strain on Ca2(+) channel expression in cultured bone cells. Compared to unstrained controls, the expression of vitamin-D-sensidve Ca2(+) channels is elevated 3- to 5-fold over a 24 hr period.

Karin, Norman J.↗