Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

CMS HGCAL ECON-D ASIC : Impact of CMOS fabrication process tuning on performance and radiation tolerance

The CMS experiment’s High Granularity Calorimeter (HGCAL) upgrade will replace CMS’s existing endcap calorimeters in preparation for the High Luminosity LHC. To effectively use over 6 million channels of this “imaging”calorimeter, CMS has developed two novel Endcap Concentrator (ECON) ASICs to perform data compression/selection on detector. The ECON-D ASIC operates on the 750kHz data path, and the ECON-T ASIC on the 40MHz trigger path. These 65 nm CMOS ASICs are radiation tolerant to 200 Mrad and low power, operating at less than 2.5 mW/channel. The first full-functionality prototype ECONs were produced and characterized in 2021-23, and an initial engineering run was performed in 2024. ECON-D radiation testing for the engineering run revealed that the chip’s internal SRAMs produce intermittent read errors for a non-negligible fraction of chips. Further investigation indicated that the SRAM performance is highly sensitive to the exact parameters of the CMOS fabrication process. To both study this process sensitivity and mitigate SRAM performance issues, twenty ECON wafers were produced in 2025 with a range of doping concentrations designed to tune the underlying transistor threshold voltage by 0%, 5%, 10%, and 15% from nominal. This talk will present first measurements of ECON-D performance, power consumption, and radiation tolerance for these four variations of CMOS process.

Syal, Chinar [Fermilab]↗

Direct Mercury Detection in Landfill Leachate Using a Novel AuNP-Biopolymer Carbon Screen-Printed Electrode Sensor

A novel Au nanoparticle (AuNP)-biopolymer coated carbon screen-printed electrode (SPE) sensor was developed through the co-electrodeposition of Au and chitosan for mercury (Hg) ion detection. This new sensor showed successful Hg2+ detection in landfill leachate using square wave anodic stripping voltammetry (SWASV) with an optimized condition: a deposition potential of −0.6 V, deposition time of 200 s, amplitude of 25 mV, frequency of 60 Hz, and square wave step voltage of 4 mV. A noticeable peak was observed at +0.58 V associated with the stripping current of the Hg ion. The sensor exhibited a good sensitivity of ~0.09 μA/μg (~0.02 μA/nM) and a linear response over the concentration range of 10 to 100 ppb (50–500 nM). The limit of detection (LOD) was 1.69 ppb, which is significantly lower than the safety limit defined by the United States Environmental Protection Agency (USEPA). The sensor had an excellent selective response to Hg2+ in landfill leachate against other interfering cations (e.g., Zn2+, Pb2+, Cd2+, and Cu2+). Fifteen successive measurements with a stable peak current and a lower relative standard deviation (RSD = 5.1%) were recorded continuously using the AuNP-biopolymer-coated carbon SPE sensor, which showed excellent stability, sensitivity and reproducibility and consistent performance in detecting the Hg2+ ion. It also exhibited a good reliability and performance in measuring heavy metals in landfill leachate.

Hwang, Jae-Hoon (ORCID:0000000220100864)↗

How Bulk Sensitive is Hard X-ray Photoelectron Spectroscopy: Accounting for the Cathode–Electrolyte Interface when Addressing Oxygen Redox

Sensitivity to the `bulk' oxygen core orbital makes hard X-ray photoelectron spectroscopy (HAXPES) an appealing technique for studying oxygen redox candidates. Various studies have reported an additional O 1s peak (530-531 eV) at high voltages, which has been considered a direct signature of the bulk oxygen redox process. Here, we find the emergence of a 530.4 eV O 1s HAXPES peak for three model cathodes, Li 2 MnO 3 , Li-rich NMC, and NMC 442, that shows no clear link to oxygen redox. Instead, the 530.4 eV peak for these three systems is attributed to transition metal reduction and electrolyte decomposition in the near-surface region. Claims of oxygen redox relying on photoelectron spectroscopy must explicitly account for the surface sensitivity of this technique and the extent of the cathode degradation layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting dark matter substructures on small scales with fast radio bursts

The matter power spectrum is only weakly constrained on subgalactic scales, while physics beyond the Standard Model can leave unique imprints, especially on sub-parsec scales. We propose measuring the arrival-time difference of fast radio bursts (FRBs) along two adjacent sightlines as a new probe to dark matter substructures on scales down to ∼ 1 AU . We discuss two observational scenarios in which it may be possible to place interesting constraints on such models through the monitoring of repeating FRB sources: (i) By sending radio receivers to space to form a baseline of tens of AU or more and measuring the temporal variation of the arrival-time difference between receivers. (ii) By measuring the temporal variation of the arrival-time difference between two lensed images of one strongly lensed repeater. In both scenarios, obtaining interesting constraints requires correlating the voltage time series to measure the radio signal arrival time to sub-nanosecond precision. We find that two radio dishes separated by 20 AU may be sensitive to the enhancement of small-scale structures at ∼ 10 - 8 M ⊙ masses in the QCD axion dark matter scenario, or from an early epoch of matter domination with a reheating temperature up to 60 MeV. Other dark matter models, such as those composed of ∼ 10 - 13 M ⊙ primordial black holes produced during inflation, would also be probed by this method. We further show that a strong lensing situation of multiple images provides an equivalent ∼ 2000 AU ( σ v / 10 3 km s - 1 ) ( δ t / 10 yr ) baseline, for a typical velocity of dark matter substructures σ v and an observational time span δ . This is much more sensitive, but with the uncertainty that intervening decoherence from the interstellar medium may degrade the timing precision, and that spatial variation in the FRB emission spot may result in confounding signals. We show that the lensing magnifications of Type Ia supernovae constrain a similar quantity to such FRB timing, with present limits being equivalent to ruling out the same parameter space that would be probed by a 0.14 AU baseline.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Assessment of Photovoltaic Panels Using Impedance Spectroscopy

The goal of this project was to develop a technique for measuring internal characteristics of a PV module using light modulation under a fixed voltage bias while measuring the resulting alternating current. This technique, light-intensity modulated impedance spectroscopy (LIMIS), has the promise of detecting early signs of panel aging and degradation that could be used for example by solar farm operators to have early warnings to repair or replace panels to maintain reliability of the overall PV array. LIMIS would be complementary with the previously developed electrochemical impedance spectroscopy (EIS), which uses an alternating voltage applied electrically to a solar cell with a similar alternating current measurement. EIS has mostly been developed for individual PV cells rather than whole modules. The project was intended to assess what different information could be revealed by LIMIS, which may in some cases be more scalable to larger modules and potentially more practical to apply in field measurements without needing to electrically disconnect PV modules. We began with small 10 W PV modules and built a testbed capable of oscillating the light intensity with frequencies up to 50 kHz. In parallel, we built a large testbed for testing large 250 W PV modules. Meanwhile, we developed procedures for established measurement techniques: current–voltage (I–V), EIS, and electroluminescence (EL) imaging, where panels are subjected to forward bias while their infrared emission is recorded using a camera modified to be sensitive to IR wavelengths. In addition, we developed protocols for accelerated aging of PV modules in two ways. Thermal cycling from –40°C to +90°C simulates the diurnal temperature cycles on a rooftop. Mechanical stress by dropping a 227 g ball from a height of 1 m simulates damage such as that due to hail impacts.

14 SOLAR ENERGY↗

Cross-Linking and Charging Molecular Magnetoelectronics

Magnetoelectrics are witnessing an ever-growing success toward the voltage-controlled magnetism derived from inorganic materials. However, these inorganic materials have predominantly focused on the ferroelectromagnetism at solid-to-solid interfaces and suffered several drawbacks, including the interface-sensitive coupling mediators, high-power electric field, and limited chemical tunability. Here, we report a promising design strategy to shift the paradigm of next-generation molecular magnetoelectrics, which relies on the integration between molecular magnetism and electric conductivity though an in situ cross-linking strategy. Following this approach, we demonstrate a versatile and efficient synthesis of flexible molecular-based magnetoelectronics by cross-linking of magnetic coordination networks that incorporate conducting chain building blocks. Furthermore, the as-grown compounds feature an improved critical temperature up to 337 K and a room-temperature magnetism control of low-power electric field. It is envisaged that the cross-linking of molecular interfaces is a feasible method to couple and modulate magnetism and electron conducting systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High Capacity for Mg 2+ Deintercalation in Spinel Vanadium Oxide Nanocrystals

Nonaqueous Mg batteries can theoretically reach high energy density with cost-effective materials, yet no such device to date has performance competitive with Li-ion technologies. A major barrier is the need for oxide cathodes that combine high capacity and voltage. Very few oxides have shown intrinsic ability for Mg 2+ intercalation in electrolytes with acceptably low content of H2O. Herein, we demonstrate that nanocrystals of MgV 2 O 4 can reach high capacity for Mg 2+ deintercalation with a mechanism that preserves their spinel framework, validated through measurements with different chemical and structural sensitivity. The structural stability contrasts with other phases where reaching high capacity required distortions that introduce undesirable mechanical strain. The favorable properties of the oxide allowed cycling in a full cell with Mg metal. This work reveals new insights into the viability of multivalent intercalation in oxides, meeting a milestone toward the feasibility of high-voltage batteries with either Mg metal or Mg-ion anodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Closed-loop optimization of fast trapped-ion shuttling with sub-quanta excitation

Shuttling ions at high speed and with low motional excitation is essential for realizing fast and high-fidelity algorithms in many trapped-ion-based quantum computing architectures. Achieving such performance is challenging due to the sensitivity of an ion to electric fields and the unknown and imperfect environmental and control variables that create them. Here we implement a closed-loop optimization of the voltage waveforms that control the trajectory and axial frequency of an ion during transport in order to minimize the final motional excitation. The resulting waveforms realize fast round-trip transport of a trapped ion across multiple electrodes at speeds of 0.5 electrodes per microsecond (35 m∙s -1 for a one-way transport of 210 μm in 6 s) with a maximum of 0.36 ± 0.08 mean quanta gain. This sub-quanta gain is independent of the phase of the secular motion at the distal location, obviating the need for an electric field impulse or time delay to eliminate the coherent motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Overview of CMOS Sensors for Future Tracking Detectors

Depleted Complementary Metal-Oxide-Semiconductor (CMOS) sensors are emerging as one of the main candidate technologies for future tracking detectors in high luminosity colliders. Their capability of integrating the sensing diode into the CMOS wafer hosting the front-end electronics allows for reduced noise and higher signal sensitivity, due to the direct collection of the sensor signal by the readout electronics. They are suitable for high radiation environments due to the possibility of applying high depletion voltage and the availability of relatively high resistivity substrates. The use of a CMOS commercial fabrication process leads to their cost reduction and allows faster construction of large area detectors. In this contribution, a general perspective of the state of the art of CMOS detectors for High Energy Physics experiments is given. The main developments carried out with regard to these devices in the framework of the CERN RD50 collaboration are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

Early Fault Detection in Particle Accelerator Power Electronics Using Ensemble Learning

Early fault detection and fault prognosis are crucial to ensure efficient and safe operations of complex engineering systems such as the Spallation Neutron Source (SNS) and its power electronics (high voltage converter modulators). Following an advanced experimental facility setup that mimics SNS operating conditions, the authors successfully conducted 21 early fault detection experiments, where fault precursors are introduced in the system to a degree enough to cause degradation in the waveform signals, but not enough to reach a real fault. Nine different machine learning techniques based on ensemble trees, convolutional neural networks, support vector machines, and hierarchical voting ensembles are proposed to detect the fault precursors. Although all 9 models have shown a perfect and identical performance during the training and testing phase, the performance of most models has decreased in the next test phase once they got exposed to realworld data from the 21 experiments. The hierarchical voting ensemble, which features multiple layers of diverse models, maintains a distinguished performance in early detection of the fault precursors with 95% success rate (20/21 tests), followed by adaboost and extremely randomized trees with 52% and 48% success rates, respectively. The support vector machine models were the worst with only 24% success rate (5/21 tests). The study concluded that a successful implementation of machine learning in the SNS or particle accelerator power systems would require a major upgrade in the controller and the data acquisition system to facilitate streaming and handling big data for the machine learning models. In addition, this study shows that the best performing models were diverse and based on the ensemble concept to reduce the bias and hyperparameter sensitivity of individual models.

43 PARTICLE ACCELERATORS↗

Interdigitated electrode geometry variation and external quantum efficiency of GaN/AlGaN-based metal-semiconductor-metal UV photodetectors

Aluminum gallium-nitride (Al x Ga 1–x N)-based metal–semiconductor–metal (MSM) ultraviolet photodetectors photodetectors (PD’s) have been successfully designed and fabricated using conventional photolithography techniques and tested experimentally to study their spectral sensitivity across different Al content, x, with x varying from 0 to 0.3. (Al)GaN-based UV PD’s have wide and tunable direct band gaps. The ability to easily select the photodetected wavelength by simply varying the aluminum content of GaN thin film (Al x Ga 1–x N) is a significant advantage of these group III–V compounds. Typically, MSM PD’s grown on (Al)GaN thin films result in ultrafast photodetection because of their highly mobile carriers. These devices are limited by the carrier transit time due to the negligible capacitance presented by the interdigitated fingers. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the devices’ performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Here, coupled with the independently measured Hall mobility and electric field, we computed the carrier transit time of the devices to be as short as 1.31 ps and the bias-voltage–independent external quantum efficiencies were as high as 70% at 60 V for n-doped and intrinsic devices when operated in the reverse bias regime. Here, (Al x )Ga 1–x N photodetectors were designed to explore spectral sensitivity by altering x from 0 to 0.3.

42 ENGINEERING↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity Enhancement and Random Telegraph Noise in Magnetic Tunnel Junctions with Compensated Anisotropy

We demonstrate the manipulation of perpendicular magnetic anisotropy (PMA) in magnetic tunnel junctions (MTJs) by varying the layer stacks and temperature. PMA is tuned to compensate the shape anisotropy, giving a nonhysteretic magnetic response, a noteworthy sensitivity enhancement, and a field detectability of 1.8 nT/$\sqrt{Hz}$ at 100 kHz. Such a method is further exemplified in multiple MTJs, providing a solution to obtain desired sensitivities and operating temperatures. Additionally, the electronic noise of this MTJ is revealed as a random telegraph noise (RTN) due to a generation-recombination process. In conclusion, the observed voltage-dependent RTN could potentially be applied to true random number generators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗