Search NASA⌕ Search

SEARCH · Search NASA

Results for “well control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Diagnostic assessment of reservoir response to fracturing: a case study from Hydraulic Fracturing Test Site (HFTS) in Midland Basin

Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.

Energy & Fuels↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Optimal dynamic control for a maglev vehicle moving on multi-span guideway girders

Abstract An optimal control algorithm using a virtual tuned mass damper called virtual TMD to control the levitation force of a magnetic system is developed for resonance suppression of a maglev vehicle moving on multi-span guideway girders. Since the optimal dynamic parameters of a TMD in vibration control are well developed, the optimal tuning gains required to control the magnetic oscillations of the maglev bogie can be directly used and fed back to the maglev control system. To address the dynamic interaction analysis from the maglev vehicle to the guideway girders and vice versa, the entire coupling system is decomposed into two subsystems, one is the moving vehicle subsystem and another the stationary guideway subsystem. Then, an incremental–iterative procedure associated with the Newmark method is presented to solve the two sets of subsystem equations. Finally, the control effectiveness and parametric studies of the optimal virtual TMD scheme on resonance reduction of the moving maglev vehicle are demonstrated.

Liu, Linya↗

Sample Type Adaptable RNA depletion performance data [Slides]

Sequencing data was aligned to rRNA data sets QIIME_16S_MiDAS_4.8.1 and SILVA_138.1_LSURef_NR99 using BWA. RNA used was a composite (pool) of wastewater RNA samples collected at LANL between April 2022 and December 2022. RNA sample was split into four aliquots (STAR depletion and STAR depletion no-probe-control as well as RiboZero and RiboZero no-probe-control). All sequencing libraries were prepared from the depleted RNA samples using the same library prep method and sequenced on Illumina platforms.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the impact of COVID-19 on air quality in southern California: implications for future control policies

Abstract. In response to the coronavirus disease of 2019 (COVID-19), California issued statewide stay-at-home orders, bringing about abrupt and dramatic reductions in air pollutant emissions. This crisis offers us an unprecedented opportunity to evaluate the effectiveness of emission reductions in terms of air quality. Here we use the Weather Research and Forecasting model with Chemistry (WRF-Chem) in combination with surface observations to study the impact of the COVID-19 lockdown measures on air quality in southern California. Based on activity level statistics and satellite observations, we estimate the sectoral emission changes during the lockdown. Due to the reduced emissions, the population-weighted concentrations of fine particulate matter (PM2.5) decrease by 15 % in southern California. The emission reductions contribute 68 % of the PM2.5 concentration decrease before and after the lockdown, while meteorology variations contribute the remaining 32 %. Among all chemical compositions, the PM2.5 concentration decrease due to emission reductions is dominated by nitrate and primary components. For O3 concentrations, the emission reductions cause a decrease in rural areas but an increase in urban areas; the increase can be offset by a 70 % emission reduction in anthropogenic volatile organic compounds (VOCs). These findings suggest that a strengthened control on primary PM2.5 emissions and a well-balanced control on nitrogen oxides and VOC emissions are needed to effectively and sustainably alleviate PM2.5 and O3 pollution in southern California.

54 ENVIRONMENTAL SCIENCES↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A dimensionless number for high-throughput design of multi-principal element alloys in directed energy deposition

The present study demonstrates the development of a dimensionless number to predict the build height in the additive manufacturing technique of directed energy deposition (DED). The build height can also be used to estimate the dendrite arm spacing and, thus, the cooling rate in the fabrication of samples. A baseline sample, 316L stainless steel, was used to fit the build height to the dimensionless number. A range of process parameters, including laser power, laser feed rate, powder flow rate, layer thickness, and hatch spacing, were varied. Based upon dendrite arm spacing, the estimated cooling rate varied between 102 and 104 K/s. Using the fitted relationship for the stainless steel, high-throughput (HT) processing of multi-principal element alloys (MPEAs) was performed. For this study, HT is the ability to fabricate a batch of 25 bulk samples (∼1 cm3) with different compositions within a 5-h period with ±10 at. % accuracy. A range of compositions using in situ alloying of elemental powders in the Fe–Ni–Cr–Mo system were made. The MPEAs' build height followed the same relationship to the dimensionless number as the 316L alloy. The dimensionless number predicts both macro and meso-scale features in HT processing, thus offering a design tool for choosing process parameters in DED additive manufacturing. Also, the ability to control or increase cooling rates can enhance the ability to promote metastability as well as control meso-scale chemical distributions of alloy samples.

Islam, Zahabul (ORCID:0000000169613209)↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

Mitigating the Effect of Wind Gusts on Local Run-of-River Hydropower Plants Using Cooperative Control

This paper focuses on the challenges and solutions associated with the integration of wind farms in a hydro- dominated power system. Due to sudden increases in wind power, the system frequency can increase, causing excessive reduction in the run-of-river (ROR) system’s power. Considering their small pondage, this can result in damage to the physical structure due to water level violations which are also penalized by stakeholders. To prevent excessive ROR power deviations, ROR governor wear and tear, and to prevent tie-line deviations, a centralized, distributed, and hybrid scheme for coordinating the response from a cluster of ROR plants is examined. Both centralized and distributed control as well as their hybrids can reduce frequency peaks. However, the inclusion of decentralized cooperative controls leads to reduced governor actions from fast- acting plants while enhancing net response from the hydro unit cluster.

13 HYDRO ENERGY↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Control over Banded Morphologies and Circular Dichroism in Chiral Halide Perovskites

Chiral halide perovskites (c-HPs) merge the chirality of organic cations with the semiconducting properties of metal halide frameworks, creating a family of chiral semiconductors with tunable chiroptoelectronic behavior. Here, we describe the impact of periodic banded morphologies of textured c-HP ( R/S -NEA) 2 PbBr 4 films (NEA = 1- (1-naphthyl)ethylammonium) on their chiroptical behavior. Due to the interplay between the crystalline and glassy phases, the c-HP film growth is driven by rhythmic precipitation, producing a distinctive controllable radial banded pattern with the ( R/S -NEA) 2 PbBr 4 inorganic planes oriented parallel to the substrate. The banded morphology can be controlled, as evidenced by the growth temperature dictating the ridge-to-ridge spacing as well as the density of banded regions. The resulting circular dichroism (CD) spectral shape, intensity, and polarity vary in a seemingly random manner across processing conditions. However, these spectral features can be explained by considering key features of the banded morphology, such as refraction of the incident light due to surface morphology, birefringence, and stacked, rotated crystallites. These effects cannot be canceled by averaging front and back CD spectra of c-HP films, and our model incorporating these effects reproduces all observed CD spectra remarkably well. The control over the c-HP morphology and prediction capabilities of our CD modeling leads to further understanding of this class of semiconductors and the possibility of exploiting structural features for light polarization control akin to enhanced metamaterials.

14 SOLAR ENERGY↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗