Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind turbine controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Aggregation of Inverter-Based Resources for Modeling and Simulation

In order to conduct system dynamic studies, it is necessary to have dynamic models of both inverter and plant levels. Detailed and aggregated modeling approaches are two essential options. The detailed modeling method involves capturing the dynamic characteristics of each individual device (e.g., wind turbine or PV array), as well as their interconnections. However, as the scale of the IBR plant increases, the complexity and computation time required for detailed modeling also increase. On the other hand, aggregated modeling offers a more efficient way of representing large-scale IBRs in power system dynamic studies. This approach involves aggregating a large number of wind turbines, PV arrays, inverters, and/or plant controllers into one or a smaller number of equivalent models. In order to analyze the impact of a high-level IBR penetration in power systems, it is important to develop accurate and computationally efficient models for both the detailed and aggregated methods.

14 SOLAR ENERGY↗

Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) (Final Report) [Slides]

In this final report, we summarize activities and results from the Ultraflexible Smart Floating Offshore Wind Turbine (USFLOWT) project. The project involved co-design of a 10-MW floating offshore wind system, especially the substructure. This substructure was based on the SpiderFLOAT, an ultra-compliant, ultralight, and modular system with actuators for smart platform control that was promising for control co-design. The project’s overall goal was to unlock the floating offshore wind market based on conditions on the North Atlantic coast of the United States. Tasks summarized in the report include Task 2.3 (including controller design for the turbine and the substructure and final design of the SpiderFLOAT), Task 2.4 (final design of the active can ballasting actuator), Task 2.5 (planning for a scale demonstrator), Task 3.1 (technology to market plan), and Task 3.3 (approval in principle). The report also summarizes project dissemination activities at a variety of venues including the lead author and/or presenter for each.

17 WIND ENERGY↗

Wind turbine gearbox fault prognosis using high-frequency SCADA data

Condition-based maintenance using routinely collected Supervisory Control and Data Acquisition (SCADA) data is a promising strategy to reduce downtime and costs associated with wind farm operations and maintenance. New approaches are continuously being developed to improve the condition monitoring for wind turbines. Development of normal behaviour models is a popular approach in studies using SCADA data. This paper first presents a data-driven framework to apply normal behaviour models using an artificial neural network approach for wind turbine gearbox prognostics. A one-class support vector machine classifier, combining different error parameters, is used to analyse the normal behaviour model error to develop a robust threshold to distinguish anomalous wind turbine operation. A detailed sensitivity study is then conducted to evaluate the potential of using high-frequency SCADA data for wind turbine gearbox prognostics. The results based on operational data from one wind turbine show that, compared to the conventionally used 10-min averaged SCADA data, the use of high-frequency data is valuable as it leads to improved prognostic predictions. High-frequency data provides more insights into the dynamics of the condition of the wind turbine components and can aid in earlier detection of faults.

17 WIND ENERGY↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Numerical Analysis of Offshore Wind-Farm-Induced Drag Effects on Coastal Upwelling Dynamics

Wind farms extract momentum from the atmospheric flow, generating wind-speed deficits both within the plant, and extending downstream. When located offshore, these deficits modulate air-sea coupling, potentially impacting coastal upwelling in sensitive regions. We investigate impacts of wind farms on coastal upwelling using kilometre-scale, three-way-coupled simulations with the coupled ocean-atmosphere-wave-sediment transport system for the US West Coast. Wind-farm effects are represented by a generalised turbine drag formulation, an idealised, height-dependent body force whose magnitude is systematically varied. This approach isolates the leading-order fluid-dynamical response in a realistic coastal configuration. The atmospheric adjustment exhibits an approximately linear relation between drag force and wind-speed deficit, with wakes that expand downstream and increase in magnitude as drag increases. An empirical orthogonal function analysis of sea-surface-temperature anomalies reveals the emergence of a canonical dipole pattern under strong drag forcing. Subsurface diagnostics show consistent shoaling of the mixed layer and suppressed upward velocities in areas near wind-farm region, accompanied by compensating enhancements of shoaling closer to the coast. These results identify turbine drag as a control parameter in assessing interactions between wind-farm wake and coastal upwelling and provide scaling relationships for understanding offshore wind-farm effects on the coastal circulation dynamics.

16 TIDAL AND WAVE POWER↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Aeroservoelastic Stability of a Floating Wind Turbine

The problem of negative damping undermines the aeroservoelastic stability of floating offshore wind turbines. The negative damping problem is most prevalent around rated wind speed, where the sensitivity of thrust to wind speed is the largest. This paper investigates the implementation of peak shaving, a controller feature that limits the rated thrust by pitching the blades before rated wind speed is reached. Two controller designs are investigated: a de-tuned controller and a nacelle-feedback controller. A time-domain metric is defined, inspired by Lyapunov theory, in order to compute and assess the stability of floating offshore wind turbines. The model of the International Energy Agency 15-MW reference wind turbine mounted on the University of Maine VolturnUS-S floater is simulated in HAWC2 with the National Renewable Energy Laboratory reference open-source controller. Peak shaving is applied to the two controller designs and stability is assessed. According to the chosen metric, peak shaving does not improve the stability of the system. This is due to the trade-off between loads and error tracking: although the loads and displacements in the fore-aft direction of the turbine are reduced, the rotor-speed tracking is poorer, which increases the shaft torsion fatigue load.

17 WIND ENERGY↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

WEIS and FAST.Farm Advancements Beyond Wind Turbine Aeroelasticity

Presentation at the 7th Wind Energy Systems Engineering workshop from NREL principal engineer Jason Jonkman, Ph.D., on NREL's numerical tools Wind Energy with Integrated Servo-control (WEIS), which focuses on the integrated design of floating wind turbines, and FAST.Farm, a simulation tool for multi-turbine wind farms based on popular aero-servo-hydro-elastic solver OpenFAST. The presentation discusses recent advancements beyond wind turbine aero-elasticity.

17 WIND ENERGY↗

Measurement-driven large-eddy simulations of a diurnal cycle during a wake-steering field campaign

Abstract. High-fidelity flow modeling with data assimilation enables accurate representation of the wind farm operating environment under realistic, nonstationary atmospheric conditions. Capturing the temporal evolution of the turbulent atmospheric boundary layer is critical to understanding the behavior of wind turbines under operating conditions with simultaneously varying inflow and control inputs. This paper has three parts: the identification of a case study during a field evaluation of wake steering; the development of a tailored mesoscale-to-microscale coupling strategy that resolved local flow conditions within a large-eddy simulation (LES), using observations that did not completely capture the wind and temperature fields throughout the simulation domain; and the application of this coupling strategy to validate high-fidelity aeroelastic predictions of turbine performance and wake interactions with and without wake steering. The case study spans 4.5 h after midnight local time, during which wake steering was toggled on and off five times, achieving yaw offset angles ranging from 0 to 17°. To resolve nonstationary nighttime conditions that exhibited shear instabilities, the turbulence field was evolved starting from the diurnal cycle of the previous day. These background conditions were then used to drive wind farm simulations with two different models: an LES with actuator disk turbines and a steady-state engineering wake model. Subsequent analysis identified two representative periods during which the up- and downstream turbines were most nearly aligned with the mean wind direction and had observed yaw offsets of 0 and 15°. Both periods corresponded to partial waking on the downstream turbine, which had errors in the LES-predicted power of 4 % and 6 %, with and without wake steering. The LES was also able to capture conditions during which an upstream turbine wake induced a speedup at a downstream turbine and increased power production by up to 13 %.

17 WIND ENERGY↗

An Unsteady Actuator Line Solver to Enable Adjoint Sensitivity Studies for Wake Steering

This study demonstrates the sensitivity of wind turbine wake steering performance to blade design. An actuator line model was implemented within an unsteady adjoint solver that enables efficient execution of gradient-based optimization and sensitivity studies. After first confirming the feasibility of wake steering by controlling actuator line chord profiles and formulating a suitable objective function for wake position, a sensitivity study was conducted to determine the relative importance of chord length as a function of spanwise position on the resulting turbine wake deflection. The results presented here support the idea that blade design choices play a role in wake control. In a larger context, this study demonstrates a computational framework in which turbine and blade designs can be studied at the individual and farm-wide level to enhance wind plant controllability and manage power output.

17 WIND ENERGY↗

Validation of FAST.Farm Against Full-Scale Turbine SCADA Data for a Small Wind Farm

FAST.Farm is a new midfidelity engineering tool developed by the National Renewable Energy Laboratory targeted at accurately and efficiently predicting wind turbine power production and structural loading in wind farm settings, including wake interactions between turbines. FAST.Farm is based on some of the principles of the Dynamic Wake Meandering model—including passive tracer modeling of wake meandering—but addresses many of the limitations of previous Dynamic Wake Meandering (DWM) implementations. Previous FAST.Farm verification studies show the similarities and differences between FAST.Farm and large-eddy simulations for rigid and flexible turbines. In this validation study, FAST.Farm turbine responses are compared to multiturbine measurements from a subset of a full-scale wind farm. FAST.Farm predictions of turbine generator power, rotor speed, and blade pitch for five-turbine simulations are compared to supervisory control and data acquisition results. Results reveal that FAST.Farm generator power mean and standard deviation results reasonably match measured data for upstream and downstream turbines, as well as the mean rotor speed and blade pitch above rated wind speeds. However, FAST.Farm generally underpredicts the mean rotor speed and overpredicts the mean blade pitch below rated operation. These errors are likely related to inaccuracies in the generic controller simulated. Despite controller differences, FAST.Farm predicts the same overall relative rotor power trends for all waked turbines at all wind speeds.

17 WIND ENERGY↗

Drivetrain Reliability Collaborative 1.5 (DRC1.5) Project: Joint Industry Megawatt Scale Gearbox Field Tests: Cooperative Research and Development (Final Report) CRADA Number CRD-17-00702

A new Department of Energy (DOE)/NREL industry collaboration called the Drivetrain Reliability Collaborative 1.5 (DRC1.5) will undertake field testing on a commercial multi-megawatt wind turbine drivetrain to collect loading data as installed in the turbine to thoroughly characterize drivetrain loads and responses during actual in-field conditions. A chief outcome is to provide publicly available operational loading data to the industry. This will provide a greater understanding of steady-state, transient, and fault response for both the input and output of the drivetrain; thus, facilitating improvements in the drivetrain components, lubrication system, power converter or turbine controller.

17 WIND ENERGY↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

Sensitivity Analysis of Numerical Modeling Input Parameters on Wind Turbine Loads in Deterministic Transient Load Cases

Aero-hydro-elastic-servo numerical models used to design and analyze wind turbines are based on thousands of variable input parameters that dictate the inflow, aerodynamic, structural, and control characteristics of the system as well as sea state, hydrodynamic, and mooring characteristics for fixed-bottom and floating offshore wind turbines. Each of these parameters has some level of uncertainty, which can significantly impact the predicted loads. Understanding the uncertainty in the inputs is critical to understanding the uncertainty in the outputs. This work demonstrates a screening technique to identify which parameters ultimate loads are most sensitive to so that more focus can be given to quantifying the possible range of those parameters. This technique has been demonstrated previously for different turbine and load case types and is extended here for a floating offshore wind turbine in design load cases with transient events both in the inflow and operations. Each load case features a deterministic gust, including variations in wind speed, direction, and shear. Load cases are considered with an operating turbine as well as with prescribed fault, startup, and shutdown procedures. The study found that key input parameters with a large impact on loads include the length of the gust, the magnitude of direction change and speed in the gust, the initial wind speed, and the shape of the gust profile.

17 WIND ENERGY↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗