Search NASA⌕ Search

SEARCH · Search NASA

Results for “14 - SOLAR ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Site Occupancy Preference and Magnetic Properties in Nd 2 (Fe,Co) 14 B

Partial replacement of Fe by Co is an effective method to increase Curie temperature (T C ) , which improves the thermal stability of magnetic properties in Nd 2 Fe 14 B-based permanent magnets. The correlation between Fe substitution and magnetic properties has been studied in Nd 2 (Fe,Co) 14 B via a first-principles calculation. The calculated Fe substitution energies indicate that the Co atoms avoid the 8 j 2 site, which agrees with the experiments. The Co atoms are ferromagnetically coupled with Fe sublattice and show magnetic moments of about 1.2 to 1.7 μ B at different crystallographic sites, less than that of Fe (2.1–2.7 μ B ), resulting in the decrease in total magnetization at ground state (0 K) with increasing Co content. The effective exchange interaction parameter, derived from the energy difference between varied magnetic structures, increases from 7.8 meV to 17.0 meV with increasing Co content from x = 0 to x = 14 in Nd 2 Fe 14–x Co x B. This change in the effective exchange interaction parameter is responsible for the enhancement of T C in Nd 2 (Fe,Co) 14 B. The total magnetization at 300 K, derived from mean-field theory, shows a peak maximum value at x = 1 in Nd 2 Fe 14–x Co x B. The phenomenon results from the interplay between the reduction of the magnetic moment in the Fe(Co) sublattice and the enhancement of T C with increasing Co content.

36 MATERIALS SCIENCE↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Do not forget the electrons: Extending moderately-sized nuclear networks for multidimensional hydrodynamic codes

Context.Nuclear networks are widely used coupled with hydrodynamical simulations of explosive scenarios to account for the change of nuclear species and energy generation rate due to nuclear reactions. In this way, there is a feedback mechanism between the hydrodynamical state and the nuclear processes. Unfortunately, the timescale of nuclear reactions is orders of magnitude smaller than the dynamical timescale that drives hydrodynamical simulations. Therefore, these nuclear networks are usually very small, reduced in most cases to a dozen elements, especially when simulations are carried out in more than one dimension. Aims.We present here an extended nuclear network, with 90 species, designed for being coupled with hydrodynamic simulations, which includes neutrons, protons, electrons, positrons, and the corresponding neutrino and anti-neutrino emission. This network is also coupled with temperature, making it extremely robust and, together with its size, unique of its kind. The inclusion of electron captures on free protons makes the network very appropriate for multidimensional studies of Type Ia supernova explosions, especially when the exploding object is a massive white dwarf. Methods.We perform several tests that are relevant to simulate explosive scenarios, such as Type Ia supernovae and core-collapse supernovae. We compare the results of the 90 nuclei network with a standardα-chain network with 14 elements to evaluate the differences in the energy generation rate. We also evaluate the relevance of including the electrons in the network in terms of generated yields and how it affects the pressure of a degenerate fluid such as that of white dwarfs. The results obtained with the 90-nuclei network have been verified with a much larger 2000-nuclei network built from REACLIB (WinNet), in terms of nuclear energy generation rate, pressure, and produced yields. Results.The results obtained with the proposed medium-sized network compare fairly well, to a few percent, with those computed withWinNetin scenarios reproducing the gross physical conditions of current Type Ia supernova explosion models. In those cases where the carbon and oxygen fuel ignites at high density, the high-temperature plateau typical of the nuclear statistical equilibrium regime is well defined and stable, allowing large integration time steps. We show that the inclusion of electron captures on free protons substantially improves the estimation of the electron fraction of the mixture. Therefore, the pressure is better determined than in networks where electron captures are excluded, which will ultimately lead to more reliable hydrodynamic models. Explosive combustion of helium at low density, occurring near the surface layer of a white dwarf, is also better described with the proposed network, which gives nuclear energy generation rates much closer toWinNetthan typical reduced alpha networks. Conclusions.A nuclear network withN= 90 species, including electrons, aimed at multidimensional calculations of supernova explosions is described and verified. The proposed network is suitable for the study of Type Ia supernova explosions because it provides better values of pressure and electron abundance than other existing networks with smaller or even a similar size but without including electron capture processes.

Astronomy & Astrophysics↗

Findings from the NETL Well Integrity Workshop: Insights for multiple subsurface energy operations

Wells are a core aspect of subsurface energy infrastructure. Ensuring the resilience of that infrastructure relies on the integrity of wells as engineered pathways that safely extract, inject, and store fluids in the subsurface. To identify areas where focused research can yield new insights to improve integrity and extend the operational life of wells, the United States (US) Department of Energys (DOE) National Energy Technology Laboratory (NETL) organized and hosted a workshop on well integrity research needs in May and June of 2021. The three-day workshop consisted of six technical sessions and 18 presentations from international well integrity experts on topics of geologic storage of carbon dioxide, natural gas, and hydrogen, as well as hydrocarbon and geothermal energy production. There were over 350 registrants from more than 10 countries, 4 major oil & gas companies, 14 US states, 8 US DOE National Laboratories, US Departments of Interior, Transportation, and Energy, and regulators from eight of ten US Environmental Protection Agency (EPA) regions and US EPA headquarters. Through presentations, moderated discussions, and an attendee survey several important areas for future research were identified. In this presentation, we highlight the findings of the NETL well integrity workshop and discuss future well integrity research needs.

carbon capture utilization and storage (CCUS)↗

Boson Fermion Nucleus And The Phenomenon Of Nuclear Fission (Monograph #14)

Nuclear fission can be induced by a neutron with insufficient energy to physically impact and disrupt the nucleus. A boson fermion nucleus (BFN) capturing an incident neutron at the same quantum state as a neutron in the BFN structure, or an assimilated incident neutron altering the quantum state of a neutron or proton in the structure to match another, is sufficient by the Pauli exclusion principle to disrupt the organized nuclear structure. This creates a scission point and force imbalance where the inverse radius squared (1/r 2 ) electrostatic repulsive force among protons dominates over the inverse radius exponential (1/e µr ) strong, short-range attractive Yukawa force among nucleons. The result is nuclear fission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Late Peaking Afterglow of GR8 100418A

GRB 100418A is a long Gamma-Ray Burst at redshift z=0.6235 discovered with the Swift Gamma-Ray Burst Explorer with unusual optical and X-ray light curves ' After an initial short-lived, rapid decline in X-rays, the optical and X-ray light curves observed with Swift are approximately flat or rising slightly out to at least approx.7 ks after the trigger, peak at approx.50 ks, and then follow an approximately power-law decay. Such a long optical plateau and late peaking is rarely seen in 6R8 afterglows. Observations with REM during a gap in the Swift coverage indicate a bright optical flare at approx.25 ks, The long plateau phase of the afterglow is interpreted using either a model with continuous injection of energy into the forward shock of the burst or a model in which the 'et of the burst is viewed off-axis. In both models the isotropic kinetic energy in the late afterglow after the plateau phase is >100 times the 10(exp 51) erg of the prompt isotropic gamma-ray energy release. The energy injection model is favored because the off-axis 'et model would require the intrinsic $T f801$ for the GR8 'et viewed on-axis to be very short, approx.10 ms, and the intrinsic isotropic gamma-ray energy release and the true jet energy to be much higher than the typical values of known short GRBs^ The non-detection of a 'et break up to approx.2 Ms indicates a jet half-opening angle of at least 14 degrees, and a relatively high collimation-corrected 'et energy of at least 10(exp 52) erg.

Marshall, Frank↗

Atomic, Molecular, and Optical Physics: Optical Excitation Function of H(1s-2p) Produced by electron Impact from Threshold to 1.8 keV

The optical excitation function of prompt Lyman-Alpha radiation, produced by electron impact on atomic hydrogen, has been measured over the extended energy range from threshold to 1.8 keV. Measurements were obtained in a crossed-beams experiment using both magnetically confined and electrostatically focused electrons in collision with atomic hydrogen produced by an intense discharge source. A vacuum-ultraviolet mono- chromator system was used to measure the emitted Lyman-Alpha radiation. The absolute H(1s-2p) electron impact excitation cross section was obtained from the experimental optical excitation function by normalizing to the accepted optical oscillator strength, with corrections for polarization and cascade. Statistical and known systematic uncertainties in our data range from +/- 4% near threshold to +/- 2% at 1.8 keV. Multistate coupling affecting the shape of the excitation function up to 1 keV impact energy is apparent in both the present experimental data and present theoretical results obtained with convergent close- coupling (CCC) theory. This shape function effect leads to an uncertainty in absolute cross sections at the 10% level in the analysis of the experimental data. The derived optimized absolute cross sections are within 7% of the CCC calculations over the 14 eV-1.8 keV range. The present CCC calculations converge on the Bethe- Fano profile for H(1s-2p) excitation at high energy. For this reason agreement with the CCC values to within 3% is achieved in a nonoptimal normalization of the experimental data to the Bethe-Fano profile. The fundamental H(1s-2p) electron impact cross section is thereby determined to an unprecedented accuracy over the 14 eV - 1.8 keV energy range.

James, G. K.↗

Temperature dependence of electronic energy transfer and quenching in copolymer films of styrene and 2-(2'-hydroxy-5'-vinylphenyl)-2H-benzotriazole

Quenching of the emission of both the polystyrene monomer and the excimer for a series of varying composition copolymer films of styrene and 2-(2'-hydroxy-5'-vinylphenyl)-2H-benzotriazole is reported. The preponderance of quenching for both the monomer and excimer emissions is due to interception of the migrating excitation at the quencher site, although additional quenching results via long-range dipole-dipole energy transfer from the monomer and excimer traps to the quencher trap. The quenching of the monomer fluorescence and phosphorescence and that of the excimer fluorescence were found to be temperature independent over the ranges 14-58 and 191-296 K, respectively. Most significantly, it is concluded that the energy migration process is temperature independent over the range 14-296 K.

O'Connor, Donald B.↗

The Broadband Counterpart of the Short GRB 200522A at z = 0.5536: A Luminous Kilonova or a Collimated Outflow with a Reverse Shock?

In this work, we present the discovery of the radio afterglow and near-infrared (NIR) counterpart of the Swift short gamma-ray burst (GRB) GRB 200522A, located at a small projected offset of ≈1 kpc from the center of a young, star-forming host galaxy at z = 0.5536. The radio and X-ray luminosities of the afterglow are consistent with those of on-axis cosmological short GRBs. The NIR counterpart, revealed by our Hubble Space Telescope observations at a rest-frame time of ≈2.3 days, has a luminosity of ≈(1.3–1.7) × 10 42 erg s -1 . This is substantially lower than on-axis short GRB afterglow detections but is a factor of ≈8–17 more luminous than the kilonova of GW170817 and significantly more luminous than any kilonova candidate for which comparable observations exist. The combination of the counterpart's color (i - y = -0.08 ± 0.21; rest frame) and luminosity cannot be explained by standard radioactive heating alone. Additionally, we present two scenarios to interpret the broadband behavior of GRB 200522A: a synchrotron forward shock with a luminous kilonova (potentially boosted by magnetar energy deposition), or forward and reverse shocks from a ≈14°, relativistic (Γ0 ≳ 10) jet. Models that include a combination of enhanced radioactive heating rates, low-lanthanide mass fractions, or additional sources of heating from late-time central engine activity may provide viable alternate explanations. If a stable magnetar was indeed produced in GRB 200522A, we predict that late-time radio emission will be detectable starting ≈0.3–6 yr after the burst for a deposited energy of ≈10 53 erg. Counterparts of similar luminosity to GRB 200522A associated with gravitational wave events will be detectable with current optical searches to ≈250 Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Testosterone on Mixed-Muscle Protein Synthesis and Proteome Dynamics During Energy Deficit

Effects of testosterone on integrated muscle protein metabolism and muscle mass during energy deficit are undetermined. The objective was to determine the effects of testosterone on mixed-muscle protein synthesis (MPS), proteome-wide fractional synthesis rates (FSR), and skeletal muscle mass during energy deficit. This was a randomized, double-blind, placebo-controlled trial. The study was conducted at Pennington Biomedical Research Center. Fifty healthy men. The study consisted of 14 days of weight maintenance, followed by a 28-day 55% energy deficit with 200 mg testosterone enanthate (TEST, n = 24) or placebo (PLA, n = 26) weekly, and up to 42 days of ad libitum recovery feeding. Mixed-MPS and proteome-wide FSR before (Pre), during (Mid), and after (Post) the energy deficit were determined using heavy water (days 1-42) and muscle biopsies. Muscle mass was determined using the D3-creatine dilution method. Mixed-MPS was lower than Pre at Mid and Post (P < 0.0005), with no difference between TEST and PLA. The proportion of individual proteins with numerically higher FSR in TEST than PLA was significant by 2-tailed binomial test at Post (52/67; P < 0.05), but not Mid (32/67; P > 0.05). Muscle mass was unchanged during energy deficit but was greater in TEST than PLA during recovery (P < 0.05). The high proportion of individual proteins with greater FSR in TEST than PLA at Post suggests exogenous testosterone exerted a delayed but broad stimulatory effect on synthesis rates across the muscle proteome during energy deficit, resulting in muscle mass accretion during subsequent recovery.

Endocrinology & Metabolism↗

A Guideline to Mitigate Interfacial Degradation Processes in Solid‐State Batteries Caused by Cross Diffusion

Abstract Diffusion of transition metals across the cathode–electrolyte interface is identified as a key challenge for the practical realization of solid‐state batteries. This is related to the formation of highly resistive interphases impeding the charge transport across the materials. Herein, the hypothesis that formation of interphases is associated with the incorporation of Co into the Li 7 La 3 Zr 2 O 12 lattice representing the starting point of a cascade of degradation processes is investigated. It is shown that Co incorporates into the garnet structure preferably four‐fold coordinated as Co 2+ or Co 3+ depending on oxygen fugacity. The solubility limit of Co is determined to be around 0.16 per formula unit, whereby concentrations beyond this limit causes a cubic‐to‐tetragonal phase transition. Moreover, the temperature‐dependent Co diffusion coefficient is determined, for example, D 700 °C = 9.46 × 10 −14 cm 2 s −1 and an activation energy E a = 1.65 eV, suggesting that detrimental cross diffusion will take place at any relevant process condition. Additionally, the optimal protective Al 2 O 3 coating thickness for relevant temperatures is studied, which allows to create a process diagram to mitigate any degradation with a minimum compromise on electrochemical performance. This study provides a tool to optimize processing conditions toward developing high energy density solid‐state batteries.

Chemistry↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

β + Gamow-Teller Strengths from Unstable 14 O via the (d, 2 He) Reaction in Inverse Kinematics

For the first time, the (d, 2 He) reaction was successfully used in inverse kinematics to extract the Gamow-Teller transition strength in the β + direction from an unstable nucleus. The new technique was made possible by the use of an active-target time-projection chamber and a magnetic spectrometer, and opens a path to addressing a range of scientific challenges, including in astrophysics and neutrino physics. Here, in this Letter, the nucleus studied was 14 O, and the Gamow-Teller transition strength to 14 N was extracted up to an excitation energy of 22 MeV. The data were compared to shell-model and state-of-the-art coupled-cluster calculations. Shell-model calculations reproduce the measured Gamow-Teller strength distribution up to about 15 MeV reasonably well, after the application of a phenomenological quenching factor. In a significant step forward to better understand this quenching, the coupled-cluster calculation reproduces the full strength distribution well without such quenching, owing to the large model space, the inclusion of strong correlations, and the coupling of the weak interaction to two nucleons through two-body currents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Optimization of Structured Multi-Functional Trapping Catalysts for Conversion of Hydrocarbons and NOx from Diesel and Advanced Combustion Engines

Oxides of nitrogen in the form of nitric oxide (NO) and nitrogen dioxide (NO 2 ) commonly referred to as NOx, is one of the two chemical precursors that lead to ground-level ozone, a ubiquitous air pollutant in urban areas. A major source of NOx is generated by equipment and vehicles powered by diesel engines, which have a combustion exhaust that contains NOx in the presence of excess O 2 . Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NO x during engine cold-start when exhaust temperatures are below 200°C. The objective of the project was to develop and demonstrate a multi-functional, catalyzed trap that enables vehicles with advanced combustion strategies to meet Tier 3 emissions standards while achieving the 150 °C challenge for sustained co-oxidation of HCs and CO and ≥90% NO trapping and release during warmup. Specifically, the multi-functional Lean HC+NOx (LHCNT) was developed for application in the exhaust aftertreatment of conventional diesel engines and engines having low temperature combustion (LTC) regimes. Activities included the design and synthesis of adsorbents and catalysts, screening and evaluation. Passive NOx absorbers (PNA), hydrocarbon (HC) traps, and oxidation catalysts (OC) were evaluated for use in series or as integrated devices. Predictive tools were developed utilizing the characterization and analysis of these materials, and an emission system was designed and optimized utilizing the catalyst systems. Microkinetic models were developed for the PNA for the simple NO-only feed and complex feed containing CO, H 2 , and model hydrocarbons (ethylene and dodecane). A first-principles, mechanistic-based model of the PNA was developed which utilized molecular-scale estimates (density functional theory) of energy barriers, mechanistic-based kinetics and realistic treatments of the flow and transport processes. Two new oxidation catalysts were developed (PdCu alloy, mixed copper-ceria-cobalt oxide), both of which significantly lessened the detrimental inhibition by CO on hydrocarbon and NO oxidation. A method for lessening the detrimental impact of CO on PNA activity was developed that involves use of an oxidation catalyst upstream of the PNA. The SwRI Ectolab TM burner system was applied to evaluate the baseline PNA material and confirmed performance comparable to the benchflow PNA studies using simulated exhaust. Spatially-resolved mass spectrometry (SpaciMS) was used to measure the transient spatial profiles of reacting species spanning the length of a three-function LHCNT containing PNA, HCT, and OC. The findings from this study provide diesel vehicle and catalyst companies valuable information to develop more cost effective emission control catalysts which helps to expand the use of more fuel efficient diesel power. The fundamental modeling and experimental tools and findings from this project can be applied to catalyst technologies used in the energy and chemical industries. The project led to 14 publications in the peer-reviewed literature with 2 additional currently under review. Finally, the project also led to training of several doctoral students who were placed in research jobs in industry and academia. Specifically, Mugdha Ambast (UH) has joined Cummins, Kevin Gu (UVa) has joined GM, and Abhay Gupta (UH) is to join Caterpillar.

42 ENGINEERING↗

Recommendations to Improve Nuclear Licensing: Update to INL/RPT-23-72206, Recommendations to Improve the Nuclear Regulatory Commission Reactor Licensing and Approval Process

In 2023, various stakeholders had asked for BEA’s thoughts and recommendations to improve the U.S. Nuclear Regulatory Commission’s (NRC) licensing review and approval process. This included an April 14, 2023 request from the House Committee on Energy and Commerce on “information and recommendations to improve the licensing review and approval process, . . . as well as the siting, licensing, construction, and oversight of advanced nuclear reactor technologies.” In response to these requests, BEA prepared and published INL/RPT-23-72206, Recommendations to Improve the Nuclear Regulatory Commission Reactor Licensing and Approval Process (2023 Report). The 2023 Report included 13 recommendations related to streamlining NRC hearings, expediting NRC safety and environmental reviews, otherwise improving NRC licensing, and providing financial benefits to new reactor projects. Many of these earlier recommendations were addressed through various legislative actions or changes made by the NRC. Section 2 of this report addresses the current status of those earlier recommendations. BEA recently received a new request from the House Committee on Energy and Commerce seeking any suggestions for additional areas to examine or potential reforms “that may assist in modernizing the licensing and regulatory process that affects civil nuclear deployment.” Additionally, the new Secretary of Energy has identified initial DOE actions to support unleashing the golden era of American energy dominance, including “Unleash Commercial Nuclear Power in the United States” and “Streamline Permitting and Identify Undue Burdens on American Energy.” Given these developments, BEA has prepared a new set of updated recommendations in this report. The recommendations include updated versions of recommendations from the 2023 Report which have not been fully adopted, as well as entirely new recommendations. This set of recommendations has a slightly broader focus with some recommendations focused on DOE authorizations and some recommendations related to nuclear licensing beyond new reactors. Each recommendation below also identifies whether the recommendation would require legislative action or could be addressed directly by the respective agency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

University of Miami G-band Vapor Radiometer Calibration (UMGVR_CAL) Field Campaign Report

Cold-air outbreak (CAO) clouds in the Arctic are commonly mixed-phase (MP); however, the partitioning of the amount of ice and water in CAO clouds and precipitation is not always well observed. Understanding how cloud phases partition as a function of cloud life cycle is important for predicting snowfall rates, convective life cycle, and intensity at weather timescales. The partitioning into liquid versus ice also has radiative impacts that are consequential for climate. These concerns motivated the incorporation of an airborne G-band vapor radiometer (GVR) into an National Science Foundation-supported aircraft campaign named the Cold Air outbreak Experiment in the Sub-Arctic Region (CAESAR). The GVR is an upward-pointing passive microwave radiometer using four frequencies centered around the 183.31 GHz water vapor absorption line, displaced by +- 1, 3, 7, and 14 GHz. For context, The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility operates a surface-based GVR at its North Slope of Alaska (NSA) site. The same GVR has been used previously for a field campaign in the southeast Pacific, where an offset was noticed between brightness temperatures (Tbs) measured under clear skies compared to those calculated from a radiative transfer model. To account for any calibration offsets to the Tbs, a request was made to DOE to allow the GVR to operate at ARM’s Southern Great Plains (SGP) observatory and enable comparisons between its measurements and those available at SGP. This request was granted, titled ‘UMGVR_CAL’, short for ‘UMGVR_Calibration’. From October 30 to November 10, 2023, the GVR was deployed to the ARM SGP site to take advantage of their regular, nearby radiosonde launches under clear-sky conditions. The latter were determined using the SGP total sky imagery data. The GVR brightness temperatures in these clear-sky conditions were compared to those calculated by a radiative transfer code (PAMTRA) based on the SGP radiosondes. During the campaign, four suitable clear-sky episodes could be used for the GVR calibration. While few in number, these proved to be enough to satisfy our goal.

54 ENVIRONMENTAL SCIENCES↗

A burst of energetic gamma rays

A burst of gamma rays with energies greater than 1 MeV occurring on May 14, 1972, at 201247 UT (151247 local time) was detected during a balloon flight from Palestine, Texas, at a float altitude of 4g/sq cm residual atmosphere. The detector was a tank of liquid scintillator 1m x 0.5 m x 15 cm surrounded by a 0.6 cm plastic scintillator in anticoincidence. The signal was 60 standard deviations above a steady background of 600 counts/sec. The flux was 0.12 (+0.07 or -0.04) gamma/sq cm, and the time integrated flux 20(+11 or -7) gamma/sq cm. Only one such event was seen during the 8 hours of observation in the daytime on May 14 and 15. Two sub-flares in H alpha occurred during the burst, but not coincident with the start time. A detector on the Solrad satellite observed X-rays on all channels 2 minutes after the gamma ray start time. This event is similar to three earlier reported events.

Koga, R.↗