Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Three-dimensional superlattice engineering with block copolymer epitaxy

Three-dimensional (3D) structures at the nanometer length scale play a crucial role in modern devices, but their fabrication using traditional top-down approaches is complex and expensive. Analogous to atomic lattices, block copolymers (BCPs) spontaneously form a rich variety of 3D nanostructures and have the potential to substantially simplify 3D nanofabrication. Here, we show that the 3D superlattice formed by BCP micelles can be controlled by lithographically defined 2D templates matching a crystallographic plane in the 3D superlattice. Using scanning transmission electron microscopy tomography, we demonstrate precise control over the lattice symmetry and orientation. Excellent ordering and substrate registration can be achieved, propagating through 284-nanometer-thick films. BCP epitaxy also showed exceptional lattice tunability, with a continuous Bain transformation from a body-centered cubic to a face-centered cubic lattice. Lattice stability was mediated by molecular packing frustration, and surface-induced lattice reconstruction was observed, leading to the formation of a unique honeycomb lattice.

42 ENGINEERING↗

Prior data assisted compressed sensing: A novel MR imaging strategy for real time tracking of lung tumors

Purpose: Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal compressed sensing (CS) imaging strategy for the real time MRI–-prior data assisted compressed sensing (PDACS), which aims to improve the image quality of the conventional CS without significantly increasing reconstruction times. Methods: Conventional 2D CS requires a random sampling of partial k-space data, as well as an iterative reconstruction that simultaneously enforces the image's sparsity in a transform domain as well as maintains the fidelity to the acquired k-space. PDACS method requires the additional acquisition of the prior data, and for reconstruction, it additionally enforces fidelity to the prior k-space domain similar to viewsharing. In this work, the authors evaluated the proposed PDACS method by comparing its results to those obtained from the 2D CS and viewsharing methods when performed individually. All three methods are used to reconstruct images from lung cancer patients whose tumors move and who are likely to benefit from lung tumor tracking. The patients are scanned, using a 3T MRI, under free breathing using the fully sampled k-space with 2D dynamic bSSFP sequence in a sagittal plane containing lung tumor. These images form a reference set for the evaluation of the partial k-space methods. To create partial k-space, the fully sampled k-space is retrospectively undersampled to obtain a range of acquisition acceleration factors, and reconstructed with 2D-CS, PDACS, and viewshare methods. For evaluation, metrics assessing global image artifacts as well as tumor contour shape fidelity are determined from the reconstructed images. These analyses are performed both for the original 3T images and those at a simulated 0.5T equivalent noise level. Results: In the 3.0T images, the PDACS strategy is shown to give superior results compared to viewshare and conventional 2D CS using all metrics. The 2D-CS tends to perform better than viewshare at the low acceleration factors, while the opposite is true at the high acceleration factors. At simulated 0.5T images, PDACS method performs only marginally better than the viewsharing method, both of which are superior compared to 2D CS. The PDACS image reconstruction time (0.3 s/image) is similar to that of the conventional 2D CS. Conclusions: The PDACS method can potentially improve the real time tracking of moving tumors by significantly increasing MRI's data acquisition speeds. In 3T images, the PDACS method does provide a benefit over the other two methods in terms of both the overall image quality and the ability to accurately and automatically contour the tumor shape. MRI's data acquisition may be accelerated using the simpler viewsharing strategy at the lower, 0.5T magnetic field, as the marginal benefit of the PDACS method may not justify its additional reconstruction times.

60 APPLIED LIFE SCIENCES↗

On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions

Purpose: As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. Methods: A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Results: Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Conclusions: Although the authors showed that CR plates can be used for patient specific IMRT QA, the practical problems such as the over-response to low energy scatter and signal fading with light exposure and time mean that alternative detectors such as radiochromic film or diode arrays will be a more sensible choice for most radiotherapy departments.

60 APPLIED LIFE SCIENCES↗

SU-F-J-54: Towards Real-Time Volumetric Imaging Using the Treatment Beam and KV Beam

Purpose: Existing real-time imaging uses dual (orthogonal) kV beam fluoroscopies and may result in significant amount of extra radiation to patients, especially for prolonged treatment cases. In addition, kV projections only provide 2D information, which is insufficient for in vivo dose reconstruction. We propose real-time volumetric imaging using prior knowledge of pre-treatment 4D images and real-time 2D transit data of treatment beam and kV beam. Methods: The pre-treatment multi-snapshot volumetric images are used to simulate 2D projections of both the treatment beam and kV beam, respectively, for each treatment field defined by the control point. During radiation delivery, the transit signals acquired by the electronic portal image device (EPID) are processed for every projection and compared with pre-calculation by cross-correlation for phase matching and thus 3D snapshot identification or real-time volumetric imaging. The data processing involves taking logarithmic ratios of EPID signals with respect to the air scan to reduce modeling uncertainties in head scatter fluence and EPID response. Simulated 2D projections are also used to pre-calculate confidence levels in phase matching. Treatment beam projections that have a low confidence level either in pre-calculation or real-time acquisition will trigger kV beams so that complementary information can be exploited. In case both the treatment beam and kV beam return low confidence in phase matching, a predicted phase based on linear regression will be generated. Results: Simulation studies indicated treatment beams provide sufficient confidence in phase matching for most cases. At times of low confidence from treatment beams, kV imaging provides sufficient confidence in phase matching due to its complementary configuration. Conclusion: The proposed real-time volumetric imaging utilizes the treatment beam and triggers kV beams for complementary information when the treatment beam along does not provide sufficient confidence for phase matching. This strategy minimizes the use of extra radiation to patients. This project is partially supported by a Varian MRA grant.

60 APPLIED LIFE SCIENCES↗

A Two-Dimensional Manganese Gallium Nitride Surface Structure Showing Ferromagnetism at Room Temperature

Practical applications of semiconductor spintronic devices necessitate ferromagnetic behavior at or above room temperature. In this paper we demonstrate a two-dimensional manganese gallium nitride surface structure (MnGaN-2D) which is atomically thin and shows ferromagnetic domain structure at room temperature as measured by spin-resolved scanning tunneling microscopy and spectroscopy. Application of small magnetic fields proves that the observed magnetic domains follow a hysteretic behavior. Two initially oppositely-oriented MnGaN-2D domains are rotated into alignment with only 120 mT and remain mostly in alignment at remanence. Additionally, the measurements are further supported by first-principles theoretical calculations which reveal highly spin-polarized and spin-split surface states, with spin polarization of up to 95% for manganese partial density of states.

36 MATERIALS SCIENCE↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Si(hhm) surfaces: Templates for developing nanostructures

The fabrication of ordered low-dimensional structures on clean and metal-atom-decorated stepped Si(557) and Si(556) surfaces is discussed. The formation conditions and atomic structure of regular step systems on clean Si(557) 7 × 7 and Si(556) 7 × 7 surfaces are studied. The atomic structure of stepped Si(hhm), Ag/Si(557), and Gd/Si(557) surfaces is studied using high-resolution scanning tunneling microscopy and low-energy electron diffraction. The possibility of fabricating 1D and 2D structures of gadolinium and silver atoms on the Si(557) surface is demonstrated.

36 MATERIALS SCIENCE↗

Cation-Driven Assembly of Bilayered Vanadium Oxide and Graphene Oxide Nanoflakes to Form Two-Dimensional Heterostructure Electrodes for Li-Ion Batteries

Lithium preintercalated bilayered vanadium oxide (LVO or δ-Li x V 2 O 5 ·nH 2 O) and graphene oxide (GO) nanoflakes were assembled using a concentrated lithium chloride solution and annealed under vacuum at 200 °C to form two-dimensional (2D) δ-Li x V 2 O 5 ·nH 2 O and reduced GO (rGO) heterostructures. Here we found that the Li + ions from LiCl enhanced the oxide/carbon heterointerface formation and served as stabilizing ions to improve structural and electrochemical stability. The graphitic content of the heterostructure could be easily controlled by changing the initial GO concentration prior to assembly. We found that increasing the GO content in our heterostructure composition helped inhibit the electrochemical degradation of LVO during cycling and improved the rate capability of the heterostructure. A combination of scanning electron microscopy and X-ray diffraction was used to help confirm that a 2D heterointerface formed between LVO and GO, and the final phase composition was determined using energy-dispersive X-ray spectroscopy and thermogravimetric analysis. Scanning transmission electron microscopy and electron energy-loss spectroscopy were additionally used to examine the heterostructures at high resolution, mapping the orientations of rGO and LVO layers and locally imaging their interlayer spacings. Further, electrochemical cycling of the cation-assembled LVO/rGO heterostructures in Li-ion cells with a non-aqueous electrolyte revealed that increasing the rGO content led to improved cycling stability and rate performance, despite slightly decreased charge storage capacity. The heterostructures with 0, 10, 20, and 35 wt % rGO exhibited capacities of 237, 216, 174, and 150 mAh g –1 , respectively. Moreover, the LVO/rGO-35 wt % and LVO/rGO-20 wt % heterostructures retained 75% (110 mAh g–1) and 67% (120 mAh g –1 ) of their initial capacities after increasing the specific current from 20 to 200 mA g –1 , while the LVO/rGO-10 wt % sample retained only 48% (107 mAh g –1 ) of its initial capacity under the same cycling conditions. In addition, the cation-assembled LVO/rGO electrodes exhibited enhanced electrochemical stability compared to electrodes prepared through physical mixing of LVO and GO nanoflakes in the same ratios as the heterostructure electrodes, further revealing the stabilizing effect of a 2D heterointerface. The cation-driven assembly approach, explored in this work using Li + cations, was found to induce and stabilize the formation of stacked 2D layers of rGO and exfoliated LVO. The reported assembly methodology can be applied for a variety of systems utilizing 2D materials with complementary properties for applications as electrodes in energy storage devices.

25 ENERGY STORAGE↗

SU-E-J-251: Fast MR-Based DRR Generation Using Highly Undersampled 3D Radial Trajectories

Purpose: The construction of a digitally reconstructed radiograph (DRR) from a magnetic resonance image (MRI) is possible if the cortical bone signal can be acquired and separated from air and soft tissue. This may be accomplished by subtracting a long echo-time, in-phase, gradient echo (GRE) image volume from an ultra-short echo time free induction decay (FID) image to produce a bone-enhanced (BE) image that reveals cortical bone. One limitation of this approach is the length of time required for data acquisition, which can limit the quality of the DRRs due to patient and organ motion. This study aimed to significantly reduce the acquisition time without compromising DRR quality. Methods: Brain data were acquired from two volunteers using a 3T MR scanner (Ingenia, Philips Healthcare). The FID and GRE images were acquired in a single acquisition using a 3D radial readout sequence with the following parameters: TE1=0.142ms (ultra-short), TE2=2.197ms (nearly in-phase), 2*2*2mm3 isotropic voxels, 250*250*250mm3 FOV. To reduce the acquisition time, k-space was sampled at 75, 50 and 25% of a full 3D sphere . The TE2 image was subtracted from the TE1 image to generate the BE images. The BE images were used to generate DRRs using the Pinnacle treatment planning system (Philips-version 9.2). The quality of the DRRs was evaluated qualitatively by 5 board certified medical physicists for clinical usefulness. Results: The acquisition time for 75, 50 and 25% sampling schemes were 219s, 146s, and 73s, respectively, the latter of which was a four-fold reduction in scan time compared to a 300s fully-sampled acquisition. All DRRs obtained were of acceptable quality and were shown to have sufficient information for clinical 2D image matching. Conclusion: Undersampling k-space while maintaining the same range of frequency information results in significantly reduced scan time and clinically acceptable DRR image quality. Drs. B Traughber and R Muzic have research support from Philips Healthcare. Drs. M Traughber and L Hu are employees of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Towards Simultaneous Multi-Parameter Measurements Using Burst-Mode Frequency-Scanning Planar Laser-Induced Fluorescence

While planar laser-induced fluorescence (PLIF) can provide valuable flow visualization, there are many challenges in extracting quantitative measurements from the fluorescence intensity. To overcome the multi-parameter dependence of the signal intensity, frequency scanning planar laser-induced fluorescence (FS-PLIF) provides the potential for 2D temperature, pressure, and velocity measurements by spectrally resolving the excitation spectrum of one or more fluorescence transitions to extract the Doppler shift, Doppler- and collisional-broadening of absorption lines, and the relative signal intensities of multiple transitions. This work aims to characterize a burst-mode FS-PLIF system consisting of a Spectral Energies, LLC burst-mode laser coupled with a Spectral Energies, LLC optical parametric oscillator using nitric oxide (NO) static pressure cell measurements. The effect of the OPO cavity on intensity fluctuations during frequency-scanning is investigated. A NO PLIF model is implemented to investigate the feasibility of property measurements using single- and two-NO-line scans.

burst-mode laser↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1D Magnetic MX 3 Single-Chains (M = Cr, V and X = Cl, Br, I)

Magnetic materials in reduced dimensions are not only excellent platforms for fundamental studies of magnetism, but they play crucial roles in technological advances. The discovery of intrinsic magnetism in monolayer 2D van der Waals systems has sparked enormous interest, but the single-chain limit of 1D magnetic van der Waals materials has been largely unexplored. This paper reports on a family of 1D magnetic van der Waals materials with composition MX 3 (M = Cr, V, and X = Cl, Br, I), prepared in fully-isolated fashion within the protective cores of carbon nanotubes. Atomic-resolution scanning transmission electron microscopy identifies unique structures that differ from the well-known 2D honeycomb lattice MX 3 structure. Density functional theory calculations reveal charge-driven reversible magnetic phase transitions.

1D materials↗

Mesoscale Magnetostructural Phase Separation in Fe‐deficient Fe 5 GeTe 2

Two-dimensional van der Waals ferromagnet Fe 5-x GeTe 2 (F5GT) is promising for spintronic applications due to its high Curie temperature, layered structure, and ability to host complex magnetic textures. However, the origin of its sample-dependent magnetic anisotropy remains unclear, hindering control of its magnetic behavior. Here, we use spatially resolved cryogenic scanning transmission electron microscopy (STEM) to correlatively map magnetism, lattice structure, and chemistry across atomic-to-micron scales. We reveal that only mesoscale, not nanoscale, inclusions of a Fe-deficient secondary phase significantly modify magnetic behavior, establishing a previously unrecognized critical length scale. This phase separation, induced by quenching, leads to in-plane magnetic anisotropy, while slow cooling confines separation to a few nanometers and preserves out-of-plane anisotropy. These findings reconcile prior inconsistencies and establish a predictive framework for tuning magnetism in F5GT through thermal processing, with broader implications for controlling anisotropy in other two-dimensional magnetic materials.

2D ferromagnets↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Deep Learning Enabled Strain Mapping of Single-Atom Defects in Two-Dimensional Transition Metal Dichalcogenides with Sub-Picometer Precision

Two-dimensional (2D) materials offer an ideal platform to study the strain fields induced by individual atomic defects, yet challenges associated with radiation damage have so far limited electron microscopy methods to probe these atomic-scale strain fields. In this work, we demonstrate an approach to probe single-atom defects with sub-picometer precision in a monolayer 2D transition metal dichalcogenide, WSe 2–2x Te 2x . We utilize deep learning to mine large data sets of aberration-corrected scanning transmission electron microscopy images to locate and classify point defects. By combining hundreds of images of nominally identical defects, we generate high signal-to-noise class averages which allow us to measure 2D atomic spacings with up to 0.2 pm precision. Our methods reveal that Se vacancies introduce complex, oscillating strain fields in the WSe 2–2x Te 2x lattice that correspond to alternating rings of lattice expansion and contraction. These results indicate the potential impact of computer vision for the development of high-precision electron microscopy methods for beam-sensitive materials.

2D materials↗

SU-G-TeP1-12: Random Repainting as Mitigation for Scanned Ion Beam Interplay Effects

Purpose: Interference of dose application in scanned beam particle therapy and organ motion may lead to interplay effects with distorted dose to target volumes. Interplay effects depend on the speed and direction of the scanning beam, leading to fringed field edges (scanning parallel to organ motion direction) or over- and under-dosed regions (both directions are orthogonal). Current repainting methods can mitigate interplay effects, but are susceptible to artefacts when only a limited number of repaints are applied. In this study a random layered-repainting strategy was investigated. Methods: Mono-energetic proton beams were irradiated to a 10 ×10 cm{sup 2} scanned field at a Varian ProBeam facility. Applied dose was measured with a 2D amorphous silicon detector mounted on a motion platform (CIRS dynamic platform). Motion was considered with different cycles, directions and translations up to ±8 mm. Dose distributions were measured for a static case, regular repainting (repeated meander-like path) and random repainting. Latter was realized by randomly distributing single spot locations during irradiation for a given number of repaints. Efficiency of repainting was analyzed by comparison to the static case. A simulation tool based on treatment logs and motion information was developed to compare measurement results to expected dose distributions. Results: Regular repainting could reduce motion artefacts, but dose distortion was strongly dependent on motion direction. Random repainting with same number of repaints (N=4) showed superior results, independent of target movement direction, while introducing slight penalty on delivery times, caused by an increase of overall scanning travel distance. The simulation tool showed good agreement to measured results. Conclusion: The results demonstrate significant improvement in terms of dose conformity when layered repainting is applied in a randomized fashion. This allows for reduced target margins during treatment planning and limited number of repaints. A combination with e.g. respiratory gating is straight-forward. Authors are employees of Varian Medical Systems Particle Therapy GmbH.

43 PARTICLE ACCELERATORS↗

Evidence of Spin Frustration in a Vanadium Diselenide Monolayer Magnet

Monolayer VSe 2 , featuring both charge density wave and magnetism phenomena, represents a unique van der Waals magnet in the family of metallic 2D transition-metal dichalcogenides (2D-TMDs). Herein, by means of in situ microscopy and spectroscopic techniques, including scanning tunneling microscopy/spectroscopy, synchrotron X-ray and angle-resolved photoemission, and X-ray absorption, direct spectroscopic signatures are established, that identify the metallic 1T-phase and vanadium 3d1 electronic configuration in monolayer VSe 2 grown on graphite by molecular-beam epitaxy. Element-specific X-ray magnetic circular dichroism, complemented with magnetic susceptibility measurements, further reveals monolayer VSe 2 as a frustrated magnet, with its spins exhibiting subtle correlations, albeit in the absence of a long-range magnetic order down to 2 K and up to a 7 T magnetic field. This observation is attributed to the relative stability of the ferromagnetic and antiferromagnetic ground states, arising from its atomic-scale structural features, such as rotational disorders and edges. Finally, the results of this study extend the current understanding of metallic 2D-TMDs in the search for exotic low-dimensional quantum phenomena, and stimulate further theoretical and experimental studies on van der Waals monolayer magnets.

2D materials↗

Local strain-dependent electronic structure and perpendicular magnetic anisotropy of a MnGaN 2D magnetic monolayer

Local strain-dependent spin-polarized electronic structure of a two-dimensional (2D) magnetic layer is an exciting property for practical applications. For example, it holds the promise for advanced ultrathin spintronic nanodevices with customized electronic and magnetic properties by local strain engineering. Here, we demonstrate that the spin-polarized electronic structure of a 2D manganese gallium nitride (MnGaN-2D) magnetic monolayer is sensitive to intrinsic local lattice strain, as proven by first-principles calculations and indicated by scanning tunneling spectroscopy measurements. Atomic resolution images reveal a highly non-Gaussian lattice spacing/strain distribution, while the spectroscopy reveals variations in the electronic density of states. Simulations of the MnGaN-2D monolayer based on first-principles calculations, including both isotropic and anisotropic strains, confirm a highly strain-dependent manganese partial density of states. Spin-orbit coupling is included which indicates either out-of-plane perpendicular magnetic anisotropy (PMA) or in-plane magnetic anisotropy, dependent on the type of strain whether compressive or tensile, suggesting that MnGaN-2D is magnetoelastic. The MnGaN-2D PMA is further supported by superconducting quantum interference device magnetometry measurements which reveal a high spin polarization of ~ 79 % at room temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗