Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Element- and momentum-resolved electronic structure of the dilute magnetic semiconductor manganese doped gallium arsenide

The dilute magnetic semiconductors have promise in spin-based electronics applications due to their potential for ferromagnetic order at room temperature, and various unique switching and spin-dependent conductivity properties. However, the precise mechanism by which the transition-metal doping produces ferromagnetism has been controversial. Here we have studied a dilute magnetic semiconductor (5% manganese-doped gallium arsenide) with Bragg-reflection standing-wave hard X-ray angle-resolved photoemission spectroscopy, and resolved its electronic structure into element- and momentum- resolved components. The measured valence band intensities have been projected into element-resolved components using analogous energy scans of Ga 3d, Mn 2p, and As 3d core levels, with results in excellent agreement with element-projected Bloch spectral functions and clarification of the electronic structure of this prototypical material. This technique should be broadly applicable to other multi-element materials.

36 MATERIALS SCIENCE↗

Injection moulding of optical functional micro structures using laser structured, PVD-coated mould inserts

Micro structured optical plastics components are intensively used i. e. in consumer electronics, for optical sensors in metrology, innovative LED-lighting or laser technology. Injection moulding has proven to be successful for the large-scale production of those parts. However, the production of those parts still causes difficulties due to challenges in the moulding and demoulding of plastics parts created with laser structured mould inserts. A complete moulding of the structures often leads to increased demoulding forces, which then cause a breaking of the structures and a clogging of the mould. An innovative approach is to combine PVD-coated (physical vapour deposition), laser structured inserts and a variothermal moulding process to create functional mic8iüro structures in a one-step process. Therefore, a PVD-coating is applied after the laser structuring process in order to improve the wear resistance and the anti-adhesive properties against the plastics melt. In a series of moulding trials with polycarbonate (PC) and polymethylmethacrylate (PMMA) using different coated moulds, the mould temperature during injection was varied in the range of the glass transition and the melt temperature of the polymers. Subsequently, the surface topography of the moulded parts is evaluated by digital 3D laser-scanning microscopy. The influence of the moulding parameters and the coating of the mould insert on the moulding accuracy and the demoulding behaviour are being analysed. It is shown that micro structures created by ultra-short pulse laser ablation can be successfully replicated in a variothermal moulding process. Due to the mould coating, significant improvements could be achieved in producing micro structured optical plastics components.

36 MATERIALS SCIENCE↗

Integration of triaxial testing and pore-scale visualization of methane hydrate bearing sediments

Understanding mechanical interactions between hydrate and hosting sediments is critical for evaluating formation stability and associated environmental impacts of hydrate-bearing sediments during gas production. While core-scale studies of hydrate-bearing sediments are readily available and some explanations of observed results rely on pore-scale behavior of hydrate, actual pore-scale observations supporting the larger-scale phenomena are rarely available for hydrate-bearing sediments, especially with methane as guest molecules. The primary reasons for the scarcity include the challenge of developing tools for small-scale testing apparatus and pore-scale visualization capability. We present a testing assembly that combines pore-scale visualization and triaxial test capability of methane hydrate-bearing sediments. This testing assembly allows temperature regulation and independent control of four pressures: influent and effluent pore pressure, confining pressure, and axial pressure. Axial and lateral effective stresses can be applied independently to a 9.5 mm diameter and 19 mm long specimen while the pore pressure and temperature are controlled to maintain the stability of methane hydrate. The testing assembly also includes an X-ray transparent beryllium core holder so that 3D computed tomography scanning can be conducted during the triaxial loading. This testing assembly permits pore-scale exploration of hydrate-sediment interaction in addition to the traditional stress-strain relationship. Exemplary outcomes are presented to demonstrate applications of the testing assembly on geomechanical property estimations of methane-hydrate bearing sediments.

Seol, Yongkoo (ORCID:0000000295163405)↗

Three-dimensional superlattice engineering with block copolymer epitaxy

Three-dimensional (3D) structures at the nanometer length scale play a crucial role in modern devices, but their fabrication using traditional top-down approaches is complex and expensive. Analogous to atomic lattices, block copolymers (BCPs) spontaneously form a rich variety of 3D nanostructures and have the potential to substantially simplify 3D nanofabrication. Here, we show that the 3D superlattice formed by BCP micelles can be controlled by lithographically defined 2D templates matching a crystallographic plane in the 3D superlattice. Using scanning transmission electron microscopy tomography, we demonstrate precise control over the lattice symmetry and orientation. Excellent ordering and substrate registration can be achieved, propagating through 284-nanometer-thick films. BCP epitaxy also showed exceptional lattice tunability, with a continuous Bain transformation from a body-centered cubic to a face-centered cubic lattice. Lattice stability was mediated by molecular packing frustration, and surface-induced lattice reconstruction was observed, leading to the formation of a unique honeycomb lattice.

42 ENGINEERING↗

Gargantuan Hail in Argentina

On 8 February 2018, a supercell storm produced gargantuan (>15 cm or >6 inches in maximum dimension) hail as it moved over the heavily populated city of Villa Carlos Paz in Cordoba Province, Argentina, South America. Observations of gargantuan hail are quite rare, but the large population density here yielded numerous witnesses and social media pictures and videos from this event that document multiple large hailstones. The storm was also sampled by the newly installed operational polarimetric C-band radar in Cordoba. During the RELAMPAGO campaign, the authors interviewed local residents about their accounts of the storm, and uncovered additional social media video and photographs revealing extremely large hail at multiple locations in town. This article documents the case, including the meteorological conditions supporting the storm (with the aid of a high-resolution WRF simulation), the storm's observed radar signatures, and three noteworthy hailstones observed by residents. These hailstones include a freezer-preserved 4.48-inch (11.38-cm) maximum dimension stone that was scanned with a 3D infrared laser scanner, a 7.1-inch (18-cm) maximum dimension stone, and a hailstone photogrammetrically estimated to be between 7.4 and 9.3 inches (18.8-23.7-cm) in maximum dimension, which is close to or exceeds the world record for maximum dimension. Such a well-observed case is an important step forward in understanding environments and storms that produce gargantuan hail, and ultimately how to anticipate and detect such extreme events.

Kumjian, Matthew R.↗

304L Can Crush Validation Studies

Accurate prediction of ductile behavior of structural alloys up to and including failure is essential in component or system failure assessment, which is necessary for nuclear weapons alteration and life extensions programs of Sandia National Laboratories. Modeling such behavior requires computational capabilities to robustly capture strong nonlinearities (geometric and material), rate- dependent and temperature-dependent properties, and ductile failure mechanisms. This study's objective is to validate numerical simulations of a high-deformation crush of a stainless steel can. The process consists of identifying a suitable can geometry and loading conditions, conducting the laboratory testing, developing a high-quality Sierra/SM simulation, and then drawing comparisons between model and measurement to assess the fitness of the simulation in regards to material model (plasticity), finite element model construction, and failure model. Following previous material model calibration, a J 2 plasticity model with a microstructural BCJ failure model is employed to model the test specimen made of 304L stainless steel. Simulated results are verified and validated through mesh and mass-scaling convergence studies, parameter sensitivity studies, and a comparison to experimental data. The converged mesh and degree of mass-scaling are the mesh discretization with 140,372 elements, and a mass scaling with a target time increment of 1.0e-6 seconds and time step scale factor of 0.5, respectively. Results from the coupled thermal-mechanical explicit dynamic analysis are comparable to the experimental data. Simulated global force vs displacement (F/D) response predicts key points such as yield, ultimate, and kinks of the experimental F/D response. Furthermore, the final deformed shape of the can and field data predicted from the analysis are similar to that of the deformed can, as measured by 3D optical CMM scans and DIC data from the experiment.

36 MATERIALS SCIENCE↗

dlppi2 (b1)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

dl (00)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

More-Realistic Digital Modeling of a Human Body

A MATLAB computer program has been written to enable improved (relative to an older program) modeling of a human body for purposes of designing space suits and other hardware with which an astronaut must interact. The older program implements a kinematic model based on traditional anthropometric measurements that do provide important volume and surface information. The present program generates a three-dimensional (3D) whole-body model from 3D body-scan data. The program utilizes thin-plate spline theory to reposition the model without need for additional scans.

Rogge, Renee↗

Spacesuit Fit and Mobility Assessments by Digital Human Modeling

Spacesuit Fit and Mobility Assessments by Digital Human Modeling K. Han Kim (Leidos, Inc.) Elizabeth A. Benson (KBR, Inc.) Sudhakar L. Rajulu (NASA Johnson Space Center) Spacesuits are required to accommodate safe operations for astronauts across gender and a wide variety of body shapes and sizes. This goal has been of particular importance given the increasing diversity of NASA crewmembers for upcoming Missions. While testing with design prototypes is a critical step for spacesuit development, iterative mockup design, fabrication, and human subject tests can be extremely costly and time consuming. Moreover, testing with a limited subject pool has often raised questions for validity, as test subjects need to represent the entire astronaut population, not only of the past or current, but also the future. This study is aimed at demonstrating how digital human modeling (DHM) tools have been built and directly supported NASA spacesuit developments. With DHM, the computer aided design (CAD) model of a spacesuit was integrated with human body models. Two use scenarios are presented in this paper, namely fit and mobility. For fit assessments, the suit-to-body contact and compression patterns were estimated using 3D human body scan models virtually wearing a spacesuit model. A statistical fit classifier was made from the contact patterns and applied against a large database of body scans (N=2,500). With this technique, the NASA reference design spacesuit Exploration EVA Mobility Unit (xEMU)was verified to accommodate 90% of the astronaut-like population, with the critical dimensions covering 1stto 99thpercentiles of the target body measurements. A similar technique assessed XEMU mobility. The maximum reach envelopes were considered, within which the work objects and critical hardware interfaces should be located for safe and ergonomic operations. While the reach envelope geometry varies significantly with the suit wearer’s body size and strength, the existing test data did not include the subjects critically required to define suit mobility requirements, such as very small females or large males. Using the xEMU virtual model kinematically simulated and permuted for a hypothetical wearer, however, the existing data were statistically transformed and scaled. This method enabled for a parametric estimation of the reach envelopes from the 1stpercentile female or 99thpercentile male. The outcome was successfully incorporated for requirement developments. With the new DHM tools, human integration of the spacesuit was structurally simulated and predictively assessed, which would have been otherwise impossible. Also, the needs for iterative mockup and subject tests were significantly reduced, which resulted in time and cost saving. Additional work is in progress to integrate additional vehicles, tools, and hardware with DHM framework.

K Han Kim↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Three-dimensional characterization of hardened paste of hydrated tricalcium silicate by serial block-face scanning electron microscopy

With the application of a three-dimensional (3D) characterization technique, serial block-face scanning electron microscopy (SBFSEM), the 3D microstructure of a hydrated cement monomineral, tricalcium silicate (C 3 S), was measured with nanoscale resolution. The 3D morphologies of anhydrous particles, hydrated products, and capillary pores were visualized. Closed and open pores were discovered inside an anhydrous particle. The size and distribution of both the anhydrous C 3 S particles and their capillary pores were analyzed quantitatively and the porosity was determined to be 9%. The distribution of pores was found to be in a good agreement with the inner and outer product model of Hu et. al., with an inner shell distance of 860 nm. Here, considering the spatial resolution of the instrument and the volume of sample measured, most pores in this experiment could be characterized as capillary pores.

3D microstructure↗

SU-F-T-403: Impact of Dose Reduction for Simulation CT On Radiation Therapy Treatment Planning

Purpose: To investigate the feasibility of applying ALARA principles to current treatment planning CT scans. The study aims to quantitatively verify lower dose scans does not alter treatment planning. Method: Gammex 467 tissue characterization phantom with inserts of 14 different materials was scanned at seven different mA levels (30∼300 mA). CT numbers of different inserts were measured. Auto contouring for bone and lung in treatment planning system (Pinnacle) was used to evaluate the effect of CT number accuracy from treatment planning aspect, on the 30 and 300 mA-scanned images. A head CT scan intended for a 3D whole brain radiation treatment was evaluated. Dose calculations were performed on normal scanned images using clinical protocol (120 kVP, Smart mA, maximum 291 mA), and the images with added simulating noise mimicking a 70 mA scan. Plan parameters including isocenter, beam arrangements, block shapes, dose grid size and resolution, and prescriptions were kept the same for these two plans. The calculated monitor units (MUs) for these two plans were compared. Results: No significant degradation of CT number accuracy was found at lower dose levels from both the phantom scans, and the patient images with added noise. The CT numbers kept consistent when mA is higher than 60 mA. The auto contoured volumes for lung and cortical bone show 0.3% and 0.12% of differences between 30 mA and 300 mA respectively. The two forward plans created on regular and low dose images gave the same calculated MU, and 98.3% of points having <1% of dose difference. Conclusion: Both phantom and patient studies quantitatively verified low dose CT provides similar quality for treatment planning at 20–25% of regular scan dose. Therefore, there is the potential to optimize simulation CT scan protocol to fulfil the ALARA principle and limit unnecessary radiation exposure to non-targeted tissues.

60 APPLIED LIFE SCIENCES↗

Quantitative Scanning Laue Diffraction Microscopy: Application to the Study of 3D Printed Nickel-Based Superalloys

Progress in computing speed and algorithm efficiency together with advances in area detector and X-ray optics technologies have transformed the technique of synchrotron radiation-based scanning Laue X-ray microdiffraction. It has now evolved into a near real-time quantitative imaging tool for material structure and deformation at the micrometer and nanometer scales. We will review the achievements of this technique at the Advanced Light Source (Berkeley, CA, USA), and demonstrate its application in the thorough microstructural investigations of laser-assisted 3D printed nickel-based superalloys.

36 MATERIALS SCIENCE↗

Correlation approach for quality assurance of additive manufactured parts based on optical metrology

Surface topography and surface finish are two significant factors for evaluating the quality of products in additive manufacturing (AM). AM parts are fabricated layer by layer, which is quite different from traditional formative or subtractive methods. Despite rapid progress in additive manufacturing and associated optical metrology for quality control and in-situ monitoring, limited research has been conducted to investigate the reliability of 3D surface measurement data. The surface topologies scanned by multiple optical systems demonstrated significant differences due to varying sampling mechanisms, resolutions, system noises, etc. The 3D datasets should be trustworthy in order to extract parameters for quality assurance or feedback control from 3D surface measurements. In this paper, we set up new standards to evaluate the reliability of 3D surface measurement data and analyze the variation in the topographical profile. In this study, two non-contact optical methods based on Focus Variation Microscopy (FVM) and Structured Light System (SLS) were adopted to measure the surface topography of the target components. The two optical metrology systems generated two entirely different point cloud datasets. Statistical methods were applied to test the difference between the data obtained from the two systems. By using a data analytics approach for comparison, it was found that the surface roughness estimated from the point cloud data sets of FVM and SLS has no significant difference, though the point cloud data sets were completely different. This paper provides standard validation approach to evaluate the plausibility of metrology data from in-situ real-time surface analysis for process planning of AM.

36 MATERIALS SCIENCE↗