SEARCH · Search NASA
Results for “4D”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
4D Point-to-Point Ray Tracing
Explore the source record for details and available documents.
Generating a 4D Global CH(4) Product by Assimilating TROPOMI column CH(4) in NASA’s GEOS GCM
Examination of temporal and spatial CH4 variability is crucial for better understanding the human and natural processes driving climate change and ultimately designing mitigation strategies. Here we present an analysis framework that uses NASA’s GEOS General Circulation Model (GCM) to construct a high-resolution, time varying picture of atmospheric CH4 consistent with measurements from a variety of platforms, both in situ and remotely sensed. The resulting time varying atmospheric CH4 product can (i) support interpretation of high-resolution point source detection approaches, (ii) provide reanalysis fields for CH4 and other greenhouse gases, and (iii) supply boundary conditions for regional models. Our approach starts with a set of CH4 emissions from various inventories that have been adjusted to match the global annual growth rate over recent decades. These emissions are transported by the GEOS GCM, which in turn is constrained by meteorology from NASA’s Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) product. The simulated atmospheric field is compared with CH4 measurements, such as those from the TROPOspheric Monitoring Instrument (TROPOMI), and adjustments calculated following a Bayesian protocol. The accuracy of the resultant optimal atmospheric CH4 field can be demonstrated by its improved agreement (compared to a direct simulation of the CH4 inventories) with a host of independent CH4 measurements, such as those from the Total Carbon Column Observation Network (TCCON) and in situ observations from surface and airborne platforms.
The impact of remote sensing observations on cross-shelf transport estimates from 4D-Var analyses of the Mid-Atlantic Bight
Explore the source record for details and available documents.
Assessing the Iterative Finite Difference Mass Balance and 4D‐Var Methods to Derive Ammonia Emissions Over North America Using Synthetic Observations
Explore the source record for details and available documents.
Crystallographic Orientation of 1D & 2D Tellurium from 4D Scanning Transmission Electron Microscopy
Explore the source record for details and available documents.
Quantifying peak profile analysis of 2D Tellurium nanostructures by 4D-STEM
Explore the source record for details and available documents.
Attend and Decode: 4D fMRI Task Decoding Using Attention Models
Explore the source record for details and available documents.
High-Resolution Fiber-Optic Sensing System for 4D Mapping, Detection, and Characterization, and Integrity Assessment of Legacy Wellbores for Carbon Storage
Explore the source record for details and available documents.
Airborne Four-Dimensional Flight Management in a Time-based Air Traffic Control Environment
Advanced Air Traffic Control (ATC) systems are being developed which contain time-based (4D) trajectory predictions of aircraft. Airborne flight management systems (FMS) exist or are being developed with similar 4D trajectory generation capabilities. Differences between the ATC generated profiles and those generated by the airborne 4D FMS may introduce system problems. A simulation experiment was conducted to explore integration of a 4D equipped aircraft into a 4D ATC system. The NASA Langley Transport Systems Research Vehicle cockpit simulator was linked in real time to the NASA Ames Descent Advisor ATC simulation for this effort. Candidate procedures for handling 4D equipped aircraft were devised and traffic scenarios established which required time delays absorbed through speed control alone or in combination with path stretching. Dissimilarities in 4D speed strategies between airborne and ATC generated trajectories were tested in these scenarios. The 4D procedures and FMS operation were well received by airline pilot test subjects, who achieved an arrival accuracy at the metering fix of 2.9 seconds standard deviation time error. The amount and nature of the information transmitted during a time clearance were found to be somewhat of a problem using the voice radio communication channel. Dissimilarities between airborne and ATC-generated speed strategies were found to be a problem when the traffic remained on established routes. It was more efficient for 4D equipped aircraft to fly trajectories with similar, though less fuel efficient, speeds which conform to the ATC strategy. Heavy traffic conditions, where time delays forced off-route path stretching, were found to produce a potential operational benefit of the airborne 4D FMS.
Supplemental basis functions for the second transition row elements
It is noted that for molecular calculations, the basis sets presented by Huzinaga (1977) need to be augmented by (1) 5p functions to describe the 5s - 5p near degeneracy; (2) a diffuse 4d function to provide for a balanced description of the 5s2 4dn, 5s1 4d(n+1), and 4d(n+2) states of the atom; and (3) a set of 4f functions to correlate the 4d functions. Here, the diffuse 4d function is similar in function to the diffuse 3d function for the first transition row elements recommended by Hay (1977). A table is included giving the optimized values for the diffuse 4d, the 5p, and 4f (STO exponent) functions. The diffuse 4d function and the 5p functions are optimized at the SCF level on the basis of the 5s1 4d(n+1) state (except for Pd, which is optimized for the 4d10 state) and the 5s1 5p1 4dn state, respectively. The table also gives the energies and the atomic symmetries for each of the SCF calculations.
Real-time manned simulation of advanced terminal area guidance concepts for short-haul operations
A real-time simulation was conducted of three-dimensional area navigation and four-dimensional area navigation equipped (STOL) aircraft operating in a high-density terminal area traffic environment. The objectives were to examine the effects of 3D RNAV and 4D RNAV equipped aircraft on the terminal area traffic efficiency, and to examine the performance of an air traffic control system concept and associated controller display proposed for use with advanced RNAV systems. Three types of STOL aircraft were simulated each with different performance capabilities. System performance was measured in both the 4D mode and in a 3D mode; the 3D mode, used as a baseline, was simply the 4D mode less any time specification. The results show that communications workload in the 4D mode was reduced by about 35 percent compared to the 3D, while 35 percent more traffic was handled with the 4D. Aircraft holding time in the 4D mode was only 30 percent of that required in the 3D mode. In addition, the orderliness of traffic was improved significantly in the 4D mode.
Origin of spin-driven ferroelectricity and effect of external pressure on the complex magnetism of the 6 H perovskite Ba 3 HoRu 2 O 9
The compound Ba 3 HoRu 2 O 9 magnetically orders at 50 K (T N1 ), followed by another complex magnetic ordering at 10.2 K (T N2 ). The second magnetic phase transition was characterized by the coexistence of two competing magnetic ground states associated with two different magnetic wave vectors (K 1 = 0.5 0 0 and K 2 = 0.25 0.25 0). The multiferroicity and magnetoelectric coupling were predicted below T N2 in these 4d-based materials. Here, in this work, we have discussed the origin of spin-driven ferroelectricity, which is not known yet, and the nature of magnetoelectric domains. We have investigated the compound through time-of-flight neutron diffraction, synchrotron x-ray diffraction (XRD), ac susceptibility, frequency-dependent complex dielectric spectroscopy, and dc magnetization under external pressure. We have demonstrated that the noncollinear structure involving two different magnetic ions, Ru (4d) and Ho (4f), breaks the spatial inversion symmetry via inverse Dzyaloshinskii-Moriya (DM) interaction through strong 4d-4f magnetic correlation, which shifts the oxygen atoms and results in nonzero polarization. Such an observation of inverse DM interaction from two different magnetic ions which cause ferroelectricity is rarely observed. The stronger spin-orbit coupling of 4d orbital might play a major role in creating DM interaction of noncollinear spins. We have systematically studied the spin and dipolar dynamics, which exhibit intriguing behavior with shorter coherence lengths of second magnetic phase associated with the k 2 wave vector. The results manifest the development of finite-size magnetoelectric domains instead of true long-range ordering, which justifies the experimentally obtained low value of ferroelectric polarization. The lattice parameters and volume show a sharp anomaly at T N2 obtained by analyzing the temperature-dependence XRD, which is consistent with the ferroelectric transition, predicting a noncentrosymmetric space group, $P\bar{6}2c$, for this compound. Furthermore, we have investigated the effect of external pressure on this complex magnetism. The result reveals an enhancement of ordering temperature by the application of external pressure (~1.6 K/GPa). The external pressure might favor stabilizing the magnetic ground state associated with second magnetic phase. Our study shows an unconventional mechanism of spin-driven ferroelectricity involving inverse DM interaction between Ru (4d) and Ho (4f) magnetic ions due to strong 4d-4f cross coupling.
Probing compactified extra dimensions with gravitational waves
We study the effect of compact extra dimensions on the gravitational wave luminosity and waveform. We consider a toy model, with a compactified fifth dimension, and matter confined on a brane. We work in the context of five-dimensional (5D) general relativity, though we do make connections with the corresponding Kaluza-Klein effective 4D theory. We show that the luminosity of gravitational waves emitted in 5D gravity by a binary with the same characteristics (same masses and separation distance) as a 4D binary is 20.8% less relative to the 4D case, to leading post-Newtonian order. The phase of the gravitational waveform differs by 26% relative to the 4D case, to leading post-Newtonian order. Such a correction arises mainly due to the coupling between matter and dilaton field in the effective 4D picture and agrees with previous calculations when we set black holes’ scalar charges to be those computed from the Kaluza-Klein reduction. The above corrections to the waveform and the luminosity are inconsistent with the gravitational-wave and binary pulsar observations, and they thus effectively rule out the possibility of such a simple compactified higher dimensions scenario. We also comment on how our results change if there are several compactified extra dimensions and show that the discrepancy with 4D general relativity only increases.
Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition
Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.
Seismic monitoring of a small CO 2 injection using a multi-well DAS array: Operations and initial results of Stage 3 of the CO 2 CRC Otway project
Active time-lapse seismic is widely employed for monitoring CO 2 geosequestration due to its ability to track the distribution of fluids in space and time. However, standard 4D seismic monitoring suffers from several challenges, including high cost, disruption to other land uses, and, consequently, relatively large intervals between monitor surveys. Some of these challenges can be mitigated using permanently installed sources and receivers. Such an approach was tested at the CO 2 CRC Otway site by continuous offset VSP monitoring of 15,000 t of supercritical CO 2 injected into an aquifer 1,500 m deep with nine permanent seismic sources (surface orbital vibrators or SOVs) and five downhole fibre-optic receivers. This continuous monitoring is complemented by multi-well 4D VSP using a mobile vibroseis source and the same DAS receivers, which included one baseline and two monitor surveys after injection of 4,000 and 12,000 t of CO 2 . The continuous DAS-SOV monitoring detected an abrupt increase of travel times below the injection interval on the second day of injection (after injection of 300 t of CO 2 ) and tracked the growth of the areal CO 2 plume by mapping changes of reflection amplitudes. The plume is also detected by time-lapse changes of reflection amplitudes in multi-well 4D VSPs. The plume images obtained from continuous offset VSP and 4D VSP are broadly consistent with each other but with some differences due to differences in illumination, lateral variations of velocities and seismic anisotropy. Furthermore, these differences also serve as a measure of uncertainty of 4D VSP images.
End-to-End Automated Segmentation Framework for Four-Dimensional Scanning Transmission Electron Microscopy Data
Four-dimensional scanning transmission electron microscopy (4D-STEM) is powerful for rapidly characterizing arrays of nanoparticles produced via high-throughput synthesis. However, such 4D-STEM datasets typically contain thousands of nanoparticles, each characterized by thousands of diffraction patterns spatially distributed across the nanoparticle, necessitating efficient and comprehensive analysis. We propose an end-to-end segmentation framework to automatically segment each nanoparticle into regions with distinct composition/orientation of crystal grains, using only the 4D-STEM data. Bragg disk information is extracted in a physics-informed manner from the diffraction patterns at each spatial location and combined with the real space coordinates to form feature vectors. These feature vectors are then used as inputs to a Gaussian mixture model (GMM) to segment the nanoparticle into distinct regions. We also develop two visualization tools based on the GMM outputs to infer the interface transition and the degree of superposition. Our framework comprehensively integrates machine learning tools and physics knowledge, and provides a basis for substantially compressing enormous 4D-STEM datasets, e.g., by replacing the full 4D-STEM dataset for each nanoparticle with only a single set of Bragg disk features for each distinct crystal grain identified in the nanoparticle. In this article, we demonstrate the power of our framework by presenting results for real, complex datasets.
Four-dimensional emittance measurement at the Spallation Neutron Source
A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.