Search NASA⌕ Search

SEARCH · Search NASA

Results for “560”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Anthropomorphic Telemanipulation System in Terminus Control Mode

This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

glove exoskeleton force-sensing master glove EVA s↗

Initial Al-26/Al-27 in Carbonaceous-chondrite Chondrules: Too little Al-26 to Melt Asteroids

We report Mg-26 excesses correlated with Al/Mg ratios in five chondrules from the primitive CO3.0 chondrite Yamato 81020 that yield a mean initial Al-26/Al-27 ratio of only (3.8 +/- 0.7) x 10(exp -6) about half that of ordinary chondrite (OC)chondrules. Even if asteroids formed immediately after chondrule formation, this ratio and the mean Al content of CO chondrites is only capable of raising the temperature of a well-insulated CO asteroid to 940 K, which is more than 560 K too low to produce differentiation. The same ratio combined with the higher Al content of CV chondrites results in a CV asteroid temperature of 1100 K. We calculate that the mean initial Al-26/Al-27 ratio of about 7.4 x 10(exp -6) found in LL chondrules is only able to produce small amounts of melting, too little to produce differentiation. These results cast serious doubt on the viability of Al-26 as the heat source responsible for asteroid differentiation. Inclusion of raises temperatures about 160 K, but this increment is not enough to cause differentiation, even of an LL-chondrite asteroid.

McKeegan, Kevin D.↗

Subclinical Reactivation and Shed of Infectious Varicella Zoster Virus in Saliva of Astronauts

We have previously detected VZV in healthy astronauts both during spaceflight and shortly after landing. Herein, we show that VZV shed in seropositive astronauts is infectious. A total of 40 saliva samples were obtained from each of the 3 astronauts. From each astronaut, 14 samples were taken 109 to 133 days before liftoff, 1 sample was taken every day during 12 days in space, and one sample was taken for 14 consecutive days beginning the second day after landing. Quantitative PCR was used to detect VZV DNA in saliva. None of 42 preflight saliva samples contained VZV DNA. VZV DNA was detected in saliva from 2 of 3 astronauts. In 1 astronaut, 6 of 12 samples obtained during space flight contained 120 to 2,500 copies of VZV DNA per ml; after landing, 1250 copies of VZV DNA were present on day 2, 45 copies on day 3, and 110 copies on day 5. All samples taken 6 to 15 days after touchdown were negative for VZV DNA. In the second astronaut, 5 of 12 samples obtained during space flight contained 18 to 650 copies of VZV DNA per ml; after landing, 560 copies of VZV DNA were present in saliva on day 2, 340 copies on day 4, 45 copies on day 5, and 23 copes on day 6. All samples taken 7 to 15 days after touchdown were negative for VZV DNA. Saliva taken 2 to 6 days after landing from all 3 astronauts was cultured on human fetal lung cells. After one subcultivation, a cytopathic effect developed in cultures inoculated with saliva from the two astronauts whose saliva contained VZV DNA. Both PCR and immunostaining identified the isolates to be VZV and not HSV-1. Importantly, the astronaut in whom no VZV was detected had a history of zoster 9 years earlier. It is possible that a boost in cell-mediated immunity to VZV which is known to develop after zoster protected him from subclinical reactivation. The genotype of the two VZV isolates was determined by VZV ORF22-based PCR/sequencing along with FRET-based PCR assays that target specific nucleotide polymorphisms. Both VZV isolates were found to be the European genotype which also contained a rare MspI restriction enodnuclease site in VZV ORF62 at position 107,252. These findings extend our previous demonstration of VZV DNA in saliva of astronauts by showing that infectious VZV is also present. Thus, like HSV-1 and HSV-2, VZV can reactivate and shed infectious virus in the absence of clinical disease.

Cohrs, Randall J.↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

An Examination of Selected Geomagnetic Indices in Relation to the Sunspot Cycle

Previous studies have shown geomagnetic indices to be useful for providing early estimates for the size of the following sunspot cycle several years in advance. Examined this study are various precursor methods for predicting the minimum and maximum amplitude of the following sunspot cycle, these precursors based on the aa and Ap geomagnetic indices and the number of disturbed days (NDD), days when the daily Ap index equaled or exceeded 25. Also examined is the yearly peak of the daily Ap index (Apmax), the number of days when Ap greater than or equal to 100, cyclic averages of sunspot number R, aa, Ap, NDD, and the number of sudden storm commencements (NSSC), as well the cyclic sums of NDD and NSSC. The analysis yields 90-percent prediction intervals for both the minimum and maximum amplitudes for cycle 24, the next sunspot cycle. In terms of yearly averages, the best regressions give Rmin = 9.8+/-2.9 and Rmax = 153.8+/-24.7, equivalent to Rm = 8.8+/-2.8 and RM = 159+/-5.5, based on the 12-mo moving average (or smoothed monthly mean sunspot number). Hence, cycle 24 is expected to be above average in size, similar to cycles 21 and 22, producing more than 300 sudden storm commencements and more than 560 disturbed days, of which about 25 will be Ap greater than or equal to 100. On the basis of annual averages, the sunspot minimum year for cycle 24 will be either 2006 or 2007.

Wilson, Robert M.↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

The design of a complete vector measurement system being tested over 560-635 GHz is presented. The topics include: 1) Current State-of-the-Art in Vector Measurements; 2) Submillimeter Active Imaging Requirements; 3) 600 GHz Vector Measurement System; 4) 450 MHz IF Signal; 5) 450 MHz IF signal @ 1 kHz Res. BW; 6) 450 MHz IF Signal Mixed with Shifted 450 MHz Reference Signal; 7) Reference Signal Offset Generator; 8) Cavity Bandpass Filter; 9) Miniature Multistage Helical Filter; 10) X36 450 MHz Multiplier; 11) 600 GHz Test Setup; 12) 600 GHz Transmit Module; 13) 600 GHz Receive Module; 14) Performance Tests: Amplitude Stability & Dynamic Range; 15) Performance Tests: Phase Stability; 16) Stability at Imaging Bandwidths; 17) Phase Measurement Verification; and 18) The Next Step: Imaging.

phase measurements↗

Multi-Anode Frequency Triplers at Sub-Millimeter Wavelengths

We report on the design methodology of fix-tuned split-block waveguide balanced frequency triplers working at 300,600 and 900 GHz. They feature four to six GaAs Schottky planar diodes in a balanced configuration. A 6-anode 300 GHz tripler, a 6-anode 560 GHz tripler and a 4-anode 900 GHz tripler will be fabricated with JPL membrane technology in order to minimize dielectric loading and ensure accurate thickness of the substrate. A 4-anode 600 GHz tripler was fabricated with JPL substrateless technology that delivers 0.8-1.6mW in the 540-640 GHz band at room temperature. When cooled to l2OK this tripler delivers 2-4mW from 540 to 640 GHz.

Schottky diodes↗

Polymer electrolyte membrane assembly for fuel cells

An electrolyte membrane for use in a fuel cell can contain sulfonated polyphenylether sulfones. The membrane can contain a first sulfonated polyphenylether sulfone and a second sulfonated polyphenylether sulfone, wherein the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone have equivalent weights greater than about 560, and the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone also have different equivalent weights. Also, a membrane for use in a fuel cell can contain a sulfonated polyphenylether sulfone and an unsulfonated polyphenylether sulfone. Methods for manufacturing a membrane electrode assemblies for use in fuel cells can include roughening a membrane surface. Electrodes and methods for fabricating such electrodes for use in a chemical fuel cell can include sintering an electrode. Such membranes and electrodes can be assembled into chemical fuel cells.

Yen, Shiao-Ping S.↗

Polymer electrolyte membrane assembly for fuel cells

An electrolyte membrane for use in a fuel cell can contain sulfonated polyphenylether sulfones. The membrane can contain a first sulfonated polyphenylether sulfone and a second sulfonated polyphenylether sulfone, wherein the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone have equivalent weights greater than about 560, and the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone also have different equivalent weights. Also, a membrane for use in a fuel cell can contain a sulfonated polyphenylether sulfone and an unsulfonated polyphenylether sulfone. Methods for manufacturing a membrane electrode assemblies for use in fuel cells can include roughening a membrane surface. Electrodes and methods for fabricating such electrodes for use in a chemical fuel cell can include sintering an electrode. Such membranes and electrodes can be assembled into chemical fuel cells.

Yen, Shiao-Ping S.↗

Polymer electrolyte membrane assembly for fuel cells

An electrolyte membrane for use in a fuel cell can contain sulfonated polyphenylether sulfones. The membrane can contain a first sulfonated polyphenylether sulfone and a second sulfonated polyphenylether sulfone, wherein the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone have equivalent weights greater than about 560, and the first sulfonated polyphenylether and the second sulfonated polyphenylether sulfone also have different equivalent weights. Also, a membrane for use in a fuel cell can contain a sulfonated polyphenylether sulfone and an unsulfonated polyphenylether sulfone. Methods for manufacturing a membrane electrode assemblies for use in fuel cells can include roughening a membrane surface. Electrodes and methods for fabricating such electrodes for use in a chemical fuel cell can include sintering an electrode. Such membranes and electrodes can be assembled into chemical fuel cells.

Yen, Shiao-Ping S.↗

Thermal Cycle Reliability of PBGA/CCGA 717 I/Os

Status of thermal cycle test results for a nonfunctional daisy-chained peripheral ceramic column grid array (CCGA) and its plastic ball grid array (PBGA) version. both having 560 I/Os. were presented in last year's conference. Test results included environmental data for three different thermal cycle regimes (-55 C/125 C, -55 C/100 C, and -50 C /75 C). Update information on these - especially failure type for assemblies with high and low solder volumes-were presented. The thermal cycle test procedure followed those recommended IPC-9701 for tin-lead solder joint assemblies. Revision A of this specification covers guideline thermal cycle requirements for Pb-free solder joints. Some background information discussed during release of this specification with its current guideline recommendations were also presented. In a recent reliability investigation a fully populated CCGA with 717 I/Os was also considered for assembly reliability. evaluation. The functional package is a field-programmable gate array that has much higher processing power than its previous version. This new package is smaller in dimension, has no interposer, and has a thinner column wrapped with copper for reliability improvement. This paper will also present thermal cycle test results for this package assembly and its plastic version with 728 I/Os. both of which were exposed to three different cycle regimes. Two cycle profiles were those specified by IPC- 9701A for tin-lead, i.e. -55 to 100 C and -55 to 125 C and one was a cycle profile specified by Mil-Std-883, i.e.. -65 C/150 C which is generally used for ceramic hybrid packages. Per IPC-9701 A, test vehicles were built using daisy chain packages and were continuously monitored. The effects of many process and assembly variables-including corner staking commonly used for improving resistance to mechanical loading such as drop and vibration loads--were also considered as part of the test matrix. Optical photomicrographs were taken at various thermal cycle intervals to document damage progress and behavior. Representative samples of these along with cross-sectional photomicrographs at higher magnification taken by scanning electron microscopy (SEM) to determine crack propagation and failure analyses for packages are also presented.

staking↗

Thermal Cycle Reliability and Failure Mechanisms of CCGA and PBGA Assemblies with and without Corner Staking

Area array packages (AAPs) with 1.27 mm pitch have been the packages of choice for commercial applications; they are now starting to be implemented for use in military and aerospace applications. Thermal cycling characteristics of plastic ball grid array (PBGA) and chip scale package assemblies, because of their wide usage for commercial applications, have been extensively reported on in literature. Thermal cycling represents the on-off environmental condition for most electronic products and therefore is a key factor that defines reliability.However, very limited data is available for thermal cycling behavior of ceramic packages commonly used for the aerospace applications. For high reliability applications, numerous AAPs are available with an identical design pattern both in ceramic and plastic packages. This paper compares assembly reliability of ceramic and plastic packages with the identical inputs/outputs(I/Os) and pattern. The ceramic package was in the form of ceramic column grid array (CCGA) with 560 I/Os peripheral array with the identical pad design as its plastic counterpart.

plastic ball grid array (PBGA)↗

Optoelectronic pH Meter: Further Details

A collection of documents provides further detailed information about an optoelectronic instrument that measures the pH of an aqueous cell-culture medium to within 0.1 unit in the range from 6.5 to 7.5. The instrument at an earlier stage of development was reported in Optoelectronic Instrument Monitors pH in a Culture Medium (MSC-23107), NASA Tech Briefs, Vol. 28, No. 9 (September 2004), page 4a. To recapitulate: The instrument includes a quartz cuvette through which the medium flows as it is circulated through a bioreactor. The medium contains some phenol red, which is an organic pH-indicator dye. The cuvette sits between a light source and a photodetector. [The light source in the earlier version comprised red (625 nm) and green (558 nm) light-emitting diodes (LEDs); the light source in the present version comprises a single green- (560 nm)-or-red (623 nm) LED.] The red and green are repeatedly flashed in alternation. The responses of the photodiode to the green and red are processed electronically to obtain the ratio between the amounts of green and red light transmitted through the medium. The optical absorbance of the phenol red in the green light varies as a known function of pH. Hence, the pH of the medium can be calculated from the aforesaid ratio.

Jeevarajan, Antony S.↗

600-GHz Electronically Tunable Vector Measurement System

A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

Dengler, Robert↗

High-Contrast 3.8 Micron Imaging of the Brown Dwarf/Planet-Mass Companion to GJ 758

We present L' band (3.8 Micron) MMT/Clio high-contrast imaging data for the nearby star GJ 758, which was recently reported by Thalmann et al. (2009) to have one -- possibly two-- faint comoving companions (GJ 7588 and "C", respectively). GJ 758B is detected in two distinct datasets. Additionally, we report a \textit(possible) detection of the object identified by Thalmann et al as "GJ 758C" in our more sensitive dataset, though it is likely a residual speckle. However, if it is the same object as that reported by Thalmann et al. it cannot be a companion in a bound orbit. GJ 758B has a H-L'color redder than nearly all known L--T8 dwarfs. Based on comparisons with the COND evolutionary models, GJ 758B has Te approx. 560 K (+150 K, -90 K) and a mass ranging from approx. 10-20 Mj if it is approx. 1 Gyr old to approx. 25-40 Mj if it is 8.7 Gyr old. GJ 758B is likely in a highly eccentric orbit, e approx. 0.73 (+0.12,-0.21), with a semimajor axis of approx. 44 AU (+32 AU, -14 AU). Though GJ 758B is sometimes discussed within the context of exoplanet direct imaging, its mass is likely greater than the deuterium-burning limit and its formation may resemble that of binary stars rather than that of jovian-mass planets.

Currie, Thayne↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

Titan's Aerosol and Condensation Cloud Properties in the Far-IR Between 2005 and 2010

Analyses of far-IR spectra between 20 and 560 cm(exp -1) (500 to 18 micron) recorded by the Cassini Composite Infrared Spectrometer (CIRS) yield the spectral dependence and the vertical distribution of Titan's photochemical aerosol and ice clouds. Titan's aerosol appears to be well mixed between the surface and an altitude of 300 km, with a spectral shape that does not change with latitude or time. The aerosol exhibits an extremely broad emission feature with a spectral peak at 140 cm(exp -1) (71 micron), which is not evident in laboratory simulated Titan aerosols (tholin). This low- energy aerosol emission feature may arise from low-energy molecules such as polycyclic aromatic hydrocarbons and/or nitrogenated aromatics. Unlike the vertically well-mixed aerosol, Titan's condensate clouds are located in highly restricted altitudes in the lower stratosphere, ranging between 60 and 100 km at low and moderate latitudes, to between 150 and 165 km at high northern latitudes during northern winter. Such clouds are located at altitudes where nitrile vapors are expected to condense and appear to be dominated by HCN and HC3N, which are the two most abundant nitriles in Titan's atmosphere. Associated with this ice cloud is a broad emission feature that spectrally peaks near 160 cm(exp -1) (62.5 micron). This ice composite appears to chemically change with altitude and latitude, probably as a result of differences in vapor abundance and condensation temperature, and the ice cloud appears to be global in extent. Both CIRS and the Huygens Descent Imager and Spectral Radiometer (DISR) show evidence of cloud layering in Titan's lower stratosphere. The 15 km difference in cloud altitude indicated by the two instruments suggests a difference in ice composition. CIRS also indicates a second ice cloud that exists at isolated latitudes and is consistent with hydrocarbon condensation above the tropopause. This cloud exhibits an emission feature that spectrally peaks near 80 cm(exp -1) (125 micron), possibly due to C2H6 ice or dominated by an ethane-acetylene composite ice, given that CzH6 then C2H2 are the two most abundant hydrocarbons next to methane in Titan's atmosphere.

Anderson, Carrie↗

Titan's Aerosol and Stratospheric Ice Opacities Between 18 and 500 Micrometers: Vertical and Spectral Characteristics from Cassini CIRS

Vertical distributions and spectral characteristics of Titan's photochemical aerosol and stratospheric ices are determined between 20 and 560 per centimeter (500-18 micrometers) from the Cassini Composite Infrared Spectrometer (CIRS). Results are obtained for latitudes of 15 N, 15 S, and 58 S, where accurate temperature profiles can be independently determined. In addition, estimates of aerosol and ice abundances at 62 N relative to those at 15 S are derived. Aerosol abundances are comparable at the two latitudes, but stratospheric ices are approximately 3 times more abundant at 62 N than at 15 S. Generally, nitrile ice clouds (probably HCN and HC3N), as inferred from a composite emission feature at approximately 160 per centimeter, appear to be located over a narrow altitude range in the stratosphere centered at approximately 90 km. Although most abundant at high northern latitudes, these nitrile ice clouds extend down through low latitudes and into mid southern latitudes, at least as far as 58 S. There is some evidence of a second ice cloud layer at approximately 60 km altitude at 58 S associated with an emission feature at approximately 80 per centimeter. We speculate that the identify of this cloud may be due to C2H6 ice, which in the vapor phase is the most abundant hydrocarbon (next to CH4) in the stratosphere of Titan. Unlike the highly restricted range of altitudes (50-100 km) associated with organic condensate clouds, Titan's photochemical aerosol appears to be well-mixed from the surface to the top of the stratosphere near an altitude of 300 km, and the spectral shape does not appear to change between 15 N and 58 S latitude. The ratio of aerosol-to-gas scale heights range from 1.3-2.4 at about 160 km to 1.1-1.4 at 300 km, although there is considerable variability with latitude, The aerosol exhibits a very broad emission feature peaking at approximately 140 per centimeter. Due to its extreme breadth and low wavenumber, we speculate that this feature may be caused by low-energy vibrations of two-dimensional lattice structures of large molecules. Examples of such molecules include polycyclic aromatic hydrocarbons (PAHs) and nitrogenated aromatics. Finally, volume extinction coefficients N chi EPSILON derived from 15 S CIRS data at a wavelength of lambda = 62.5 micrometers are compared with those derived from the 10 S Huygens Descent Imager/Spectral Radiometer (DISR) data at 1.583 micrometers. This comparison yields volume extinction coefficient ratios N chi EPSILON (1.583 micrometers)/N chi EPSILON (62.5 micrometers) of roughly 70 and 20, respectively, for Titan's aerosol and stratospheric ices, The inferred particle cross-section ratios chi EPSILON(1.583 micrometers)/chi EPSILON (62.5 micrometers) appear to be consistent with sub-micron size aerosol particles, and effective radii of only a few microns for stratospheric ice cloud particles.

Anderson, Carrie M.↗