Search NASA⌕ Search

SEARCH · Search NASA

Results for “AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

X-Band Ultra-Low Noise Maser Amplifier Performance

Noise temperature measurements of an 8440 MHz ultra-low noise maser amplifier (ULNA) have been performed at sub-atmospheric, liquid helium temperatures. The traveling wave maser operated while immersed in a liquid helium bath. The lowest input noise temperature measured was 1.23 plus or minus 0.16 K at a physical temperature of 1.60 kelvin. At this physical temperature the observed gain per unit length of ruby was 4.6 dB/cm, and the amplifier had a 3 dB-bandwidth of 76 MHz.

ultra-low noise maser amplifier X-band maser syste↗

Beyond G-band : a 235 GHz InP MMIC amplifier

We present results on an InP monolithic millimeter- wave integrated circuit (MMIC) amplifier having 10-dB gain at 235 GHz. We designed this circuit and fabricated the chip in Northrop Grumman Space Technology's (NGST) 0.07- m InP high electron mobility transistor (HEMT) process. Using a WR3 (220-325 GHz) waveguide vector network analyzer system interfaced to waveguide wafer probes, we measured this chip on-wafer for -parameters. To our knowledge, this is the first time a WR3 waveguide on-wafer measurement system has been used to measure gain in a MMIC amplifier above 230 GHz.

high electron mobility transistors (HEMTs)↗

Low Noise Amplifier Receivers from Millimeter Wave Atmospheric Remote Sensing

We currently achieve 3.4 dB noise figure at 183GHz and 2.1 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurement campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography altimetry.

millimeter wave radiometers↗

Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

high-power amplifier (HPA)↗

Fiber Lasers and Amplifiers for Space-based Science and Exploration

We present current and near-term uses of high-power fiber lasers and amplifiers for NASA science and spacecraft applications. Fiber lasers and amplifiers offer numerous advantages for the deployment of instruments on exploration and science remote sensing satellites. Ground-based and airborne systems provide an evolutionary path to space and a means for calibration and verification of space-borne systems. NASA fiber-laser-based instruments include laser sounders and lidars for measuring atmospheric carbon dioxide, oxygen, water vapor and methane and a pulsed or pseudo-noise (PN) code laser ranging system in the near infrared (NIR) wavelength band. The associated fiber transmitters include high-power erbium, ytterbium, and neodymium systems and a fiber laser pumped optical parametric oscillator. We discuss recent experimental progress on these systems and instrument prototypes for ongoing development efforts.

Fiber laser↗

Spectrally Efficient GaN High-Power Amplifier for Lunar Communications

The paper demonstrates a spectrally efficient Ka-band GaN MMIC based high-power amplifier (HPA) that uses a waveguide 4-port magic-tee as a 2-way power combiner to combine the output from two lower power amplifier circuits. The paper presents for the prototype HPA the measured output power, gain, power added efficiency, error vector magnitude for Offset-QPSK, 8PSK, 16APSK, 32APSK, and 16QAM waveforms, waveform spectrum, and out-of-band spectral regrowth. The HPA is intended for establishing a direct communication link between assets on the lunar surface/orbit and Earth.

Gallium nitride↗

Extreme hydroclimates amplify the biophysical effects of advanced green-up in temperate China

Vegetation phenology modulates climate by altering energy and water exchange between the land and atmosphere. However, how extreme hydroclimatic conditions modify these phenology-climate feedbacks is still poorly understood. Here, in this study, we used a land–atmosphere-coupled Weather Research and Forecasting model to explore the impacts of advanced green-up on air temperature under different hydroclimate conditions across temperate China and to Mechanistic analysis elucidate the underlying biophysical mechanisms. By imposing a 14-day earlier green-up in line with recent satellite observations, we found that under mean climate conditions, an earlier leaf-out induces immediate surface cooling of 0.14 °C during green-up and a lagging 0.02 °C warming during senescence averaged for temperate China. Extremely humid conditions amplify the cooling effects to 0.18 °C during green-up, extending this cooling into the senescence period. Conversely, under extremely arid conditions, earlier green-up cools air temperature by 0.09 °C, and amplified senescence warming to 0.16 °C. Mechanism analysis revealed that evapotranspiration-dominated non-radiative processes drive immediate cooling during green-up while radiation and circulation process dominates the delayed but opposite warming/cooling effects during senescence in extremely arid/humid hydroclimates. Given the projected continuation of warming trends and increased frequency of extreme climatic events, it is imperative to incorporate the biophysical effects of vegetation phenology into local climate adaptation strategies.

54 ENVIRONMENTAL SCIENCES↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amplified response of cavity-coupled quantum-critical systems

A quantum critical point develops when matter undergoes a continuous transformation between distinct ground states at absolute zero. It hosts pronounced quantum fluctuations, which render the system highly susceptible to external perturbations. While light-matter coupling has rapidly moved forward as a means to probe and control quantum materials, the capacity of quantum critical fluctuations in the photon-mediated responses has been largely unexplored. Here we advance the notion that directly coupling a quantum critical mode to a quantized cavity field dramatically facilitates the realization of the elusive superradiant phase transition in equilibrium, circumventing at once the key obstacles that have prevented its attainment in spite of decades of pursuit. The superradiant phase transition develops far below the ultrastrong regime of light-matter couplings, and the transition is accompanied by the light-matter hybrid system showing strongly enhanced intrinsic squeezing and amplified quantum Fisher information. We also identify candidate cavity quantum materials platforms for validating the proposed effect. Our findings suggest a general principle by which quantum criticality amplifies the response to cavity photons. They also demonstrate that cavity coupling accesses the elevated quantum entanglement of the underlying matter at quantum criticality, thereby pointing to a pathway towards realizing the potential of highly collective quantum materials to expand the capacities of quantum information science.

Sur, Shouvik [Rice Univ., Houston, TX (United Stat↗

Fundamental limits to the generation of highly displaced bright squeezed light using linear optics and parametric amplifiers

High-quality squeezed light is an important resource for a variety of applications. Multiple methods for generating squeezed light are known, having been demonstrated theoretically and experimentally. However, the effectiveness of these methods—in particular, the inherent limitations to the signals that can be produced—has received little consideration. Here we present a comparative theoretical analysis for generating a highly displaced squeezed light from a linear optical method—a beamsplitter mixing a squeezed vacuum and a strong coherent state—and well-studied parametric amplification methods including an optical parametric oscillator, an optical parametric amplifier, and a dissipative optomechanical squeezer seeded with coherent states. We show that the quality of highly displaced squeezed states that can be generated using these methods is limited on a fundamental level by the physical mechanism utilized; across all methods there are significant trade-offs between displacement, squeezing, and overall uncertainty. We explore the nature and extent of these trade-offs specific to each mechanism and identify the optimal operation modes for each. Finally, we identify the conditions for minimum-uncertainty squeezing in arbitrary parametric amplifying systems and show that displacing the output signal will in general violate these conditions, adding noise and degrading squeezing. Published by the American Physical Society 2025

Young, Steve M. (ORCID:0000000173839366)↗

Species interactions amplify functional group responses to elevated CO 2 and N enrichment in a 24‐year grassland experiment

Abstract Plant functional groups (FGs) differ in their response to global changes, although species within those groups also vary in such responses. Both species and FG responses to global change are likely influenced by species interactions such as inter‐specific competition and facilitation, which are prevalent in species mixtures but not monocultures. As most studies focus on responses of plants growing in either monocultures or mixtures, but rarely both, it remains unclear how interspecific interactions in diverse ecological communities, especially among species in different FGs, modify FG responses to global changes. To address these issues, we leveraged data from a 16‐species, 24‐year perennial grassland experiment to examine plant FG biomass responses to atmospheric CO 2 , and N inputs at different planted diversity. FGs differed in their responses to N and CO 2 treatments in monocultures. Such differences were amplified in mixtures, where N enrichment strongly increased C3 grass success at ambient CO 2 and C4 grass success at elevated CO 2 . Legumes declined with N enrichment in mixtures at both CO 2 levels and increased with elevated CO 2 in the initial years of the experiment. Our results suggest that previous studies that considered responses to global changes in monocultures may underestimate biomass changes in diverse communities where interspecific interactions can amplify responses. Such effects of interspecific interactions on responses of FGs to global change may impact community composition over time and consequently influence ecosystem functions.

Mohanbabu, Neha↗

Field-effect transistor improves electrometer amplifier

An electrometer amplifier uses a field effect transistor to measure currents of low amperage. The circuit, developed as an ac amplifier, is used with an external filter which limits bandwidth to achieve optimum noise performance.

Munoz, R.↗

Tiny biomedical amplifier combines high performance, low power drain

Transistorized, portable, high performance amplifier with low power drain facilitates biomedical studies on mobile subjects. This device, which utilizes a differential input to obtain a common-mode rejection, is used for amplifying electrocardiogram and electromyogram signals.

Deboo, G. J.↗

Field effect transistors improve buffer amplifier

Unity gain buffer amplifier with a Field Effect Transistor /FET/ differential input stage responds much faster than bipolar transistors when operated at low current levels. The circuit uses a dual FET in a unity gain buffer amplifier having extremely high input impedance, low bias current requirements, and wide bandwidth.

Source record↗