Search NASA⌕ Search

SEARCH · Search NASA

Results for “ASHRAE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Capture of Uranium Particles By Filtration: Effects of Filter Material and Air Humidity

Filtration of airborne particles is a standard technique for removal of radiological particles from the effluent of a nuclear reactor. The effects of humidity on filter performance and uranium particles are however less understood. We have conducted experimental runs in the Environmental Experimental Chamber (EEC) located at ORNL to study the capture of uranyl fluoride particles in supports of NNSA missions. Two filter types, one of Minimum Efficiency Reporting Value (MERV)-9 and the other of MERV-10 American Society of Heating, Refrigerating and Air-Conditioning Engineering) ASHRAE rating, were used in the investigations under two humidity conditions [15% and 65% Relative Humidity (Rh)]. Both MERV9 and MERV10 filters failed to capture uranyl fluoride particles that were smaller than 100 nm. The penetration efficiencies for both filter types were very high, greater than 80%, for particles from 10 to 100 nm. As particles became larger and wetter, the capturing efficiencies of both types of filter improved. Slightly greater than 50% of particles from 1 to 10 μm still escaped the capture by the MERV9 filters. However, MERV10 filters were able to capture higher than 50% of particles in the size range of 1 to 2 μm indicating it is likely to meet ASHRAE requirements. Overall, the capture efficiency of a filter is highly dependent on uranyl fluoride particle size, which humidity plays a major role. These two filter types simply are unable to capture particles smaller than 1 μm. A filter that has a higher ASHRAE rating like the HEPA filter has to be used to capture sub-micron particles. Questions on how uranyl fluoride behave in a condition higher than 65% Rh remain, because the particles could deliquescent at the higher humidity condition. That would complete change the size, shape, and surface properties of the uranyl fluoride particles which could lead to completely different filter performance and filtration dynamics. Furthermore, how high humidity affects filters of all MERV ratings remain unclear. Other filter characteristics such as surface charge could also be affected by high humidity condition and need to be investigated.

42 ENGINEERING↗

Impacts of Standard 90.1-2007 for Commercial Buildings at State Level

This nationwide analysis of commercial energy code compares ASHRAE Standard 90.1-2007 with the commercial code in each state as of June 2009. The results are provided in chapters specific to each state. States with unique energy codes were not included in the analysis because the codes in these states would be difficult to appropriately compare to ASHRAE Standard 90.1 and most of these states have energy offices that routinely assess their codes against the model codes. In states with codes prior to and including the 2000 IECC or Standard 90.1-1999, those states with no statewide energy code, and home rule states which did not specifically request that another code be used, Standard 90.1-1999 was used as the baseline for comparison. Three DOE benchmark buildings were used for the simulation used in this analysis: a medium office building (53,600 square feet), a mid-rise apartment building (33,700 square feet), and a non-refrigerated warehouse (49,500 square feet) - representing ASHRAE Standard 90.1 non-residential, residential, and semi-heated requirements, respectively. Locations for the analysis were selected based on obtaining a sample representative of each climate zone in the state, where typical meteorological year (TMY2) weather file locations existed, making sure to include the state capital. In the absence of a TMY2 weather file for a particular climate zone in a state, a representative location in an adjacent state was used for the purposes of the simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy Design Guide for K-12 School Buildings (AEDG) Training: Cooperative Research and Development Final Report, CRADA Number CRD-18-00761

U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO), Commercial Buildings Integration (CBI) Program supports the adoption of zero energy ready buildings design practices through targeted Science, Technology, Engineering, and Mathematics (STEM) workforce development. The National Renewable Energy Laboratory (NREL) identified the opportunity to provided targeted training to those professionals that have the greatest potential to impact adoption and successful design outcomes of zero energy ready buildings projects. In January 2018, ASHRAE released Achieving Zero Energy: Advanced Energy Design Guide for K-12 School Buildings (AEDG). The AEDG was developed in collaboration with NREL, American Institute of Architects (AIA), American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE), U.S. Green Building Council (USGBC), and Illuminating Engineers Society (IES). The purpose of this CRADA was to create a partnership between NREL, AIA, ASHRAE, USGBC, and IES to create and host on-demand, web-based training based on the AEDG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Trade-off between Solar Reflectance and Above-Sheathing Ventilation for Metal Roofs on Residential and Commercial Buildings

An alternative to white and cool-color roofs that meets prescriptive requirements for steep-slope (residential and non-residential) and low-slope (non-residential) roofing has been documented. Roofs fitted with an inclined air space above the sheathing (herein termed above-sheathing ventilation, or ASV), performed as well as if not better than high-reflectance, high-emittance roofs fastened directly to the deck. Field measurements demonstrated the benefit of roofs designed with ASV. A computer tool was benchmarked against the field data. Testing and benchmarks were conducted at roofs inclined at 18.34 ; the roof span from soffit to ridge was 18.7 ft (5.7 m). The tool was then exercised to compute the solar reflectance needed by a roof equipped with ASV to exhibit the same annual cooling load as that for a direct-to-deck cool-color roof. A painted metal roof with an air space height of 0.75 in. (0.019 m) and spanning 18.7 ft (5.7 m) up the roof incline of 18.34 needed only a 0.10 solar reflectance to exhibit the same annual cooling load as a direct-to-deck cool-color metal roof (solar reflectance of 0.25). This held for all eight ASHRAE climate zones complying with ASHRAE 90.1 (2007a). A dark heat-absorbing roof fitted with 1.5 in. (0.038 m) air space spanning 18.7 ft (5.7 m) and inclined at 18.34 was shown to have a seasonal cooling load equivalent to that of a conventional direct-to-deck cool-color metal roof. Computations for retrofit application based on ASHRAE 90.1 (1980) showed that ASV air spaces of either 0.75 or 1.5 in. (0.019 and 0.038 m) would permit black roofs to have annual cooling loads equivalent to the direct-to-deck cool roof. Results are encouraging, and a parametric study of roof slope and ASV aspect ratio is needed for developing guidelines applicable to all steep- and low-slope roof applications.

above sheathing ventilation↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

Hun, Diana E↗

The New Face of Standard 100

In January 2024, ASHRAE published a significant overhaul to ANSI/ASHRAE/IES Standard 100-2018, Energy Efficiency in Existing Buildings. You may almost not recognize it. Standard 100-2024, Energy and Emissions Building Performance Standard for Existing Buildings, now addresses both energy and emissions performance as a model building performance standard (BPS). ASHRAE Standing Standard Project Committee (SSPC) 100, with direction from ASHRAE and its Task Force for Building Decarbonization (TFBD) has been working to update the standard to make it a model for building performance standard adoption across the U.S. and internationally. Here, the new edition of Standard 100 addresses key issues of climate change surrounding building performance, including new metrics for greenhouse gas (GHG) emissions targets, continuing to support the imperative of improving our existing building stock and meeting global climate change commitments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Qualitative Determination

A final qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007 was conducted. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were evaluated by the U.S. Department of Energy (DOE) for their impact on energy efficiency. DOE preliminarily determined whether that addenda would have a positive, neutral, or negative impact on overall building efficiency. Table S.1 shows the number of positive and negative changes for each section of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2010 Preliminary Qualitative Determination

A preliminary qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 (Standard 90.1-2007 or 2007 edition) that were included in ANSI/ASHRAE/IESNA Standard 90.1-2010 (Standard 90.1-2010 or 2010 edition) was conducted. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were evaluated by DOE for their impact on energy efficiency. DOE preliminarily determined whether that addenda would have a positive, neutral, or negative impact on overall building efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

99 GENERAL AND MISCELLANEOUS↗

Simplified Performance Rating Method - Review of Existing Tools, Rulesets, and Programs. Literature and technical review

The Performance Rating Method (PRM) in ASHRAE Standard 90.1 (ASHRAE 2016) is a simulation ruleset for establishing minimum code compliance and for rating a building’s beyond-code applications. Building energy modeling (BEM) to comply with the PRM is often expensive and time consuming due to the complexity of code requirements. The goal of this project is to develop and codify a simplified PRM (S-PRM) approach for commercial buildings that will expand the use of BEM for small or simple buildings by defining a low-cost, simplified approach for creating robust and detailed models. This report summarizes a review of (i) the more commonly used existing codes, (ii) incentive programs, and (iii) the existing simplified energy modeling tools to identify which requirements are good candidates for simplification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1–2019

The purpose of this analysis is to examine the cost-effectiveness of the 2019 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1, and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2019, compared to the previous 90.1-2016 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated of energy codes. This information also informs the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2022

The purpose of this analysis is to examine the cost-effectiveness of the 2022 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1 and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2022, compared to the previous 90.1-2019 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated energy codes. This information also informs the development of future editions of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simplified Space Conditioning in Low-Load Homes

TO3 2.1.6: Simplified Space Conditioning IBACOS anticipates that houses achieving 50% whole-house source energy savings with respect to the Building America 2010 Benchmark (Hendron and Engebrecht 2010a) will be considered "low load." Low load is defined by IBACOS as a house with a thermal enclosure that yields a maximum space heating and cooling load of less than 10 Btu/h/ft2 of conditioned floor area (31.5 W/m2 [1,200 ft2 /ton]). These small loads can be met by systems other than today's typical ducted forced-air systems. For example, distributed fan coils with minimized ducts, terminal fan coil units, or point source units with buoyant force or ventilation-driven distribution may provide sufficient occupant comfort in a low-load home. These systems, which can have lower total installed costs than traditional ducted forced-air systems (Stecher 2011), allow the thermal enclosure characteristics of low-load houses to provide first-cost savings in addition to operational cost savings. The purpose of this study is to help determine cost-effective solutions for heating and cooling houses that are designed to be energy efficient. This is done by testing the occupant comfort performance of some concepts that may already exist on the market but are not in use by production homebuilders. In some cases, the products are market available, but their use in housing may be a new application. The standards used to assess the performance of the systems in this study are Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and ASHRAE Standard 55-2010 (ASHRAE 2010a).

ACCA Manual RS↗

DOAS, Radiant Cooling Revisited

The article discusses dedicated outdoor air systems (DOAS) and radiant cooling technologies. Both of these topics were covered in previous ASHRAE Journal columns. This article reviews the technologies and their increasing acceptance. The two steps that ASHRAE is taking to disseminate DOAS information to the design community, available energy savings and the market potential of radiant cooling systems are addressed as well.

Air Conditioner Condensate↗

Achieving 50% Energy Savings in New Schools, Advanced Energy Design Guides: K-12 Schools (Brochure)

This fact sheet summarizes recommendations for designing elementary, middle, and high school buildings that will result in 50% less energy use than conventional new schools built to minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for K-12 School Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use school buildings (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller schools with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of schools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗