Design and performance of a high-pressure-ratio, highly loaded axial-flow transonic compressor space

A 50-cm-diam. axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested. At design speed, a rotor peak efficiency of 0.85 occurred at an equivalent weight flow of 29.3 kg/sec. Stage peak efficiency was 0.79 at 28.6 kg/sec. Stage total pressure ratio at peak efficiency was 1.84. The stall margin at design speed was 5 percent. Rotor and stator losses were higher than predicted. The stator choked at design flow.

Lewis, G. W., Jr.↗

Conventional probes for the relative flow measurement in a rotor blade passage

This paper reports the measurement of the relative flow in the rotor blade passages of an axial flow compressor and an axial flow inducer using conventional probes such as five-hole, disc and the spherical pitot-static probes. The probe provides an inexpensive, yet accurate, method of deriving the three dimensional flow field in a rotor. The disc probe is suitable for the blade boundary layer measurement and the pitot-static probe for the static and stagnation pressures and the total velocity across the rotor passage. Typical data obtained from each of these probes demonstrate the complex nature of turbomachinery rotor flow.

Sitaram, N.↗

Performance Characteristics of an Axial-flow Transonic Compressor Operating up to Tip Relative Inlet Mach Number of 1.34

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

Creagh, John W R↗

Water ingestion into jet engine axial compressors

An axial flow compressor has been tested with water droplet ingestion under a variety of conditions. The results illustrate the manner in which the compressor pressure ratio, efficiency and surging characteristics are affected. A model for estimating the performance of a compressor during water ingestion has been developed and the predictions obtained compare favorably with the test results. It is then shown that with respect to five droplet-associated nonlinearly-interacting processes (namely, droplet-blade interactions, blade performance changes, centrifugal action, heat and mass transfer processes and droplet break-up), the initial water content and centrifugal action play the most dominant roles.

Tsuchiya, T.↗

Comparison of the effect of two damper sizes on the performance of a low-solidity axial-flow transonic compressor rotor

The experimental performance of a 20-inch-diameter axial-flow transonic compressor rotor with small dampers is presented. The compressor rotor was tested earlier with large dampers which were twice in size, and comparisons of overall performance and radial distributions of selected flow and performance parameters are made. The rotor with small dampers experienced lower losses in the damper region which resulted in locally higher values of temperature rise efficiency and total pressure ratio. However, there was no appreciable effect on overall efficiency and pressure ratio. A greater stall margin was measured for the rotor with small dampers at design speed, but at 70 and 90 percent of design speed the rotor with large dampers had somewhat greater flow range.

Lewis, G. W., Jr.↗

A turbojet simulator for Mach numbers up to 2.0

A turbojet simulator was designed and fabricated for use in wind tunnel models. The simulator contains a six-stage, axial-flow compressor powered by a three-stage, axial-flow turbine. High pressure heated air was used to drive the turbine. At design conditions, compressor axial flow, turbine exit flow, and a third supplementary flow all entered the exhaust nozzle at equal values of pressure and termperature. Overall aerodynamic design, compressor operating conditions, automatic controls, turbine aerodynamic design, instrumentation, and calibration procedure is presented. Performance of the device when used to simulate a J-85 turbojet engine at transonic speeds is reported. The installed nozzle performance obtained with the simulator is also discussed and compared with flight data.

Steffen, F. W.↗

A comparison of predicted and measured inlet distortion flows in a subsonic axial inlet flow compressor rotor

Detailed flow measurements were taken inside an isolated axial compressor rotor operating subsonically near peak efficiency. These Laser Anemometer measurements were made with two inlet velocity profiles. One profile consisted of an unmodified baseline flow, and the second profile was distorted by placing axisymmetric screens on the hub and shroud well upstream of the rotor. A detailed comparison in the rotor relative reference frame between a Navier-Stokes solver and the measured experimental results showed good agreement between the predicted and measured flows. A primary flow is defined in the rotor and deviations and the computed predictions is made to assess the development of a passage vortex due to the distortion of the inlet flow. Computer predictions indicate that a distorted inlet profile has a minimal effect on the development of the flow in the rotor passage and the resulting passage vortex.

Owen, Albert K.↗

An axial flow research compressor facility designed for flow measurement in rotor passages

An axial flow research compressor facility, which is designed for relative flow measurement, is described in this paper. The facility has a rotating probe traverse mechanism which is capable of traversing hot wire, pitot and other probes at 0.09 deg intervals across the rotor blade passage. The data transmission system includes rotating transducers, pressure transfer device, ten-channel mercury slip ring unit, scanivalve, etc. The instrumentation includes on-line data processing capability. A brief description of probes used as well as some typical data on the rotor blade static pressure, rotor endwall flow and rotor wake characteristics are given in the paper.

Lakshminarayana, B.↗

A turbojet simulator for Mach numbers up to 2.0.

A turbojet simulator has been designed and fabricated for use in wind tunnel models. The simulator contains a six-stage, axial-flow compressor powered by a three-stage, axial-flow turbine. High pressure heated air was used to drive the turbine. At design conditions, compressor axial flow, turbine exit flow, and a third supplementary flow all entered the exhaust nozzle at equal values of pressure and temperature. Overall aerodynamic design, instrumentation, and calibration procedure is presented. Performance of the device when used to simulate a J-85 turbojet engine at transonic speeds is reported. The installed nozzle performance obtained with the simulator is also discussed and compared with flight data.

Steffen, F. W.↗

Performance of Axial-Flow Supersonic Compressor on XJ-55-FF-1 Turbojet Engine. I - Preliminary Performance of Compressor: Preliminary Performance of Compressor - 1

An investigation was conducted to determine the performance characteristics of the axial-flow supersonic compressor of the XJ-55-FF-1 turbo Jet engine. The test unit consisted of a row of inlet guide vanes and a supersonic rotor; the stator vanes after the rotor were omitted. The maximum pressure ratio produced in the single stage was 2.28 at an equivalent tip speed or 1814 feet per second with an adiabatic efficiency of approximately 0.61, equivalent weight flow of 13.4 pounds per second. The maximum efficiency of 0.79 was obtained at an equivalent tip speed of 801 feet per second.

Hartmann, Melvin J.↗

Secondary flows in annular cascades and effects on flow in inlet guide vanes

Qualitative discussion is presented of the general nature of secondary flows in stationary annular cascades with thin wall boundary layers and radial design variation of circulation. Deviations from ideal mean outlet flows (based on blade-element performance) exist in potential-flow region of vanes because of conditions imposed by end-wall boundaries, displacement of wall boundary layers toward blade suction surfaces, and irrotationality requirement. As a consequence of existence of nonuniform radial flow across blade spacing, it may not generally be possible to obtain an arbitrarily specified design variation of the turning angle along the radial height of a blade row. Quantitative turning angle corrections due to effects of secondary flows in axial-flow compressor inlet guide vanes were obtained from induced deflections of a superimposed vortex system in conjunction with an empirically determined correlation factor.

CASCADES, EXPERIMENT↗

Off-design computer code for calculating the aerodynamic performance of axial-flow fans and compressors

An off-design axial-flow compressor code is presented and is available from COSMIC for predicting the aerodynamic performance maps of fans and compressors. Steady axisymmetric flow is assumed and the aerodynamic solution reduces to solving the two-dimensional flow field in the meridional plane. A streamline curvature method is used for calculating this flow-field outside the blade rows. This code allows for bleed flows and the first five stators can be reset for each rotational speed, capabilities which are necessary for large multistage compressors. The accuracy of the off-design performance predictions depend upon the validity of the flow loss and deviation correlation models. These empirical correlations for the flow loss and deviation are used to model the real flow effects and the off-design code will compute through small reverse flow regions. The input to this off-design code is fully described and a user's example case for a two-stage fan is included with complete input and output data sets. Also, a comparison of the off-design code predictions with experimental data is included which generally shows good agreement.

Schmidt, James F.↗

Performance of Axial-Flow Supersonic Compressor of XJ55-FF-1 Turbojet Engine: Over-All Performance of Compressor - III

An investigation was conducted to determine the performance characteristics of the rotor and inlet guide vanes used in the axial-flow supersonic compressor of the XJ55-FF-1 turbojet engine. Outlet stators used in the engine were omitted to facilitate study of the supersonic rotor. The extent of the deviation from design performance indicates that the design-shock configuration was not obtained. A maximum pressure ratio of 2.26 was obtained at an equivalent tip speed of 1614 feet per second and an adiabatic efficiency of 0.61. The maximum efficiency obtained was 0.79 at an equivalent tip speed of 801 feet per second and a pressure ratio of 1.29. The performance obtained was considerably below design performance. The effective aerodynamic forces encountered appeared to be large enough to cause considerable damage to the thin aluminum leading edges of the rotor blades.

Hartmann, Melvin J.↗

Performance of Axial-Flow Supersonic Compressor of the XJ55-FF-1 Turbojet Engine. IV - Analysis of Compressor Operation over a Range of Equivalent Tip Speeds from 801 to 1614 Feet Per Second

An investigation was conducted to determine the performance characteristics of the axial-flow supersonic compressor of the XJ55-FF-1 turbojet engine. An analysis of the performance of the rotor was made based on detailed flow measurements behind the rotor. The compressor apparently did not obtain the design normal-shock configuration in this investigation. A large redistribution of mass occurred toward the root of the rotor over the entire speed range; this condition was so acute at design speed that the tip sections were completely inoperative. The passage pressure recovery at maximum pressure ratio at 1614 feet per second varied from a maximum of 0.81 near the root to 0.53 near the tip, which indicated very poor efficiency of the flow process through the rotor. The results, however, indicated that the desired supersonic operation may be obtained by decreasing the effective contraction ratio of the rotor blade passage.

Graham, Robert C.↗

Effect of casing treatment on overall and blade element performance of a compressor rotor

An axial flow compressor rotor was tested at design speed with six different casing treatments across the rotor tip. Radial surveys of pressure, temperature, and flow angle were taken at the rotor inlet and outlet. Surveys were taken at several weight flows for each treatment. All the casings treatments decreased the weight flow at stall over that for the solid casing. Radial surveys indicate that the performance over the entire radial span of the blade is affected by the treatment across the rotor tip.

Moore, R. D.↗

Compressor surge

Steady state characteristics, stalling, and surge in axial flow compressors

STEADY STATE↗