Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration stress”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Effect of Engineered Cracks in Catalyst Layers on PEMFC Catalyst Layer Durability

Proton exchange membrane fuel cells (PEMFCs) are expected to play a pivotal role in decarbonizing the transportation sector, and particularly heavy-duty vehicles (HDVs). However, improvements in durability are needed for PEMFCs to compete with state-of-the-art power sources for HDVs. Here, we examine how catalyst layer (CL) cracks that are engineered affect the CL durability by using patterned silicon templates to control the CL crack density at the micrometer scale. Electrochemical analyses show that the initial PEMFC performance is relatively unaffected by crack density, but the performance after durability testing was strongly affected. Specifically, CLs with high crack density showed higher performance relative to CLs without cracks after application of a carbon corrosion accelerated stress test. Electrochemical analyses coupled with X-ray computed tomography and scanning transmission electron microscopy with energy dispersive X-ray spectroscopy showed that the cracks provide shorter oxygen diffusion pathways to reaction sites, leading to decreased oxygen transport resistance. Additionally, we observed that the catalyst durability is unaffected by cracks. Our results provide a mechanistic explanation of the role of cracks in CL durability.

30 DIRECT ENERGY CONVERSION↗

Performance and Durability of Heavy-Duty Fuel Cell Systems with an Advanced Ordered Intermetallic ORR Alloy Catalyst and Novel Support

Ordered PtCo intermetallic (OIM) catalyst (L1 0 -PtCo/C) is a promising candidate as the oxygen reduction reaction (ORR) catalyst in hybrid fuel cell systems (FCS) for class-8 heavy duty (HD) trucks. Compared to a baseline annealed Pt on high surface area carbon (a-Pt/HSC) catalyst, its mass activity (MA) is 71% higher initially and 144% higher after 90,000 potential cycles in an accelerated stress test (AST). Analysis of the AST data indicates that the ORR kinetic constants do not change with aging and the degradation in the OIM catalyst activity is linearly proportional to the loss in the electrochemically active surface area (ECSA). Several operational strategies are investigated to mitigate catalyst degradation and achieve 25,000-h electrode lifetime and 2.5 kW g −1 Pt utilization on a HD truck duty cycle including load sharing with the hybrid battery, regulating the radiator fan power to maintain the coolant temperature close to 60 °C, clipping the maximum cell voltage below 850 mV, limiting the ECSA loss to 55%, and oversizing the active area of the membrane electrode assemblies by 20%. Drive cycle simulations indicate that the lifetime average voltage degradation rate is about 1.8 μV h −1 and the integrated stack and FCS drive cycle efficiencies decrease by 3.5 to 3.9%.

25 ENERGY STORAGE↗

Membrane Pretreatment and Cell Conditioning for Proton Exchange Membrane Water Electrolysis

As the research community studying proton exchange membrane water electrolysis (PEMWE) grows, it is important to develop methods that achieve transparent, reproducible research. Reproducibility of performance and durability is a challenge facing the PEMWE field, as the published literature includes a wide spread of results obtained with nominally similar materials. Prior round-robin performance benchmarking efforts [1] have identified inadequate cell conditioning as a major source of variation in apparent cell performance. Inadequate pre-treatment and conditioning can lead to instability in initial performance and adds ambiguity to durability measurements. However, excessively prolonged conditioning procedures limit the throughput of testing and the pace of research. Pretreatment and conditioning methods vary significantly across the research literature, but little systematic investigation is available into the mechanisms of these procedures or how procedural differences may impact results. This presentation will discuss investigations into the effects of membrane pre-treatment and operating procedures during cell conditioning on initial performance and catalyst-specific accelerated stress tests, with the aim of recommending procedures to enable clear, reproducible, and high-throughput research. Methods investigated include the use of hydrogen peroxide, acids, and hydration at elevated temperature for membrane pretreatment, and conditioning procedures such as current or voltage holds and cycling. The investigations cover both the impacts of these procedures on cell performance and stability as well as underlying mechanisms and processes taking place in the cell materials.

cell↗

(Invited) Fuel Cell Component Durability for Million Mile Fuel Cell Trucks

While significant advances have been made and early commercial fuel cell light-duty vehicles (LDVs) are starting to be produced, fuel cells in the heavy-duty-vehicle (HDV) transportation sector (including trucks, long-haul semitrailers, maritime, trains, etc.) are nascent, despite the fact that advantages of fuel cells compared to both diesel and electric powertrains are very compelling in terms of emissions, charging time, efficiency, power-to-weight ratio, among others. However, the fuel-cell technology for HDVs requires a paradigm shift in fuel-cell research and development compared to LDVs, where the emphasis becomes efficiency and improvements in durability instead of a focus on increased power densities and lower cell costs. Heavy-duty applications require significantly longer vehicle lifetimes (>25,000 hours/1,000,000 miles for heavy-duty trucks), and therefore require improved fuel cell durability compared to light-duty vehicles. In 2020, HFTO formed the Million Mile Fuel Cell Truck Consortium (M2FCT) that includes a core team of five national laboratories to overcome durability and efficiency challenges in PEMFCs for heavy-duty applications with an initial focus on long-haul trucks. While targets and testing protocols have been developed for light-duty vehicles, the same level of targets and testing protocols have not been established for heavy-duty transportation. With operational times of greater than > 25,000 hours required, the need for well-developed accelerated stress tests (ASTs) is amplified. Results from these ASTs demonstrate the need for more durable electrode layers and well-controlled potential variations. Finally, this presentation will provide an overview of the DOE's Fuel Cell R&D approach, highlighting past and current activities, as well as strategies to enable fuel cell competiveness for heavy-duty applications.

25 ENERGY STORAGE↗

High Performance non-PGM Transition Metal Oxide ORR Catalysts of PEMFCs

This project was designed to develop acid-stable PGM-free transition metal oxide oxygen reduction reaction (ORR) electrocatalysts to meet or exceed the performance and durability of the DOE 2020 Technical Targets for platinum-group metal (PGM) free electrocatalysts from first-principles to incorporation into membrane-electrode assemblies (MEAs) for polymer electrolyte membrane (PEM) fuel cells. The planned project was to accomplish this goal with a multi-step approach: 1) materials modeling and experimental screening to identify acid-stable oxides with high ORR activity, 2) optimization of catalyst particle size and catalyst/carbon/ionomer catalyst layer composition, 3) fabrication of MEAs for performance and durability testing. During the course of this project: 1) acid-stability descriptors were developed for manganese oxides; 2) a family of acid-stable multicomponent oxides based on antimony were developed; 3) a flexible synthesis for the formation of nanocrystalline nonstoichiometric oxides was developed; 4) limited ORR activity but modest and improving oxygen evolution reaction (OER) activity was measured for multicomponent antimony oxides. The project was programmed into five technical tasks: The development of acid-stable ORR electrocatalytic oxides through 1) identification and optimization of acid-stable oxide compositions, and 2) electrochemical characterization; 3) optimization of catalyst layer composition for MEAs using identified ORR electrocatalysts; 4) MEA fabrication and performance testing to result in performance of 44 mA-cm-2 at 0.9 V vs. RHE; and 5) accelerated-stress testing of optimized MEAs. Because no acid-stable oxide was identified with the requisite activity for ORR (4.4 µA-cm-2oxide intrinsic activity at 0.9 V vs. RHE) within the time and budget allotted in Tasks 1 and 2, the project was halted at the end of phase 1, with no activity in Tasks 3-5. The research output, while not succeeding in developing ORR electrocatalysts, advanced the development of acid-stable oxide materials, showing potential for further improvement as OER electrocatalysts.

08 HYDROGEN↗

AST Development in M2FCT (ASTWG and iDWG) Update to 21CTP [Slides]

Accelerated Stress Tests (ASTs) are required to evaluate fuel cell component durability in a reasonable time. Current DOE and FCTT ASTs are light duty focused with 5000 – 8000 hour durability requirements. Heavy duty ASTs need to reflect the 25000+ hour durability requirement. Interim solution is to extend the duration of the current light duty ASTs: Catalyst AST has been extended from 30,000 cycles to 90,000 cycles (From 50 hours to 150 hours). We need to understand Heavy duty stressors and tailor ASTs for heavy duty applications: Longer lifetimes; Higher efficiencies – Higher loadings - Potentially higher operating temperatures and voltages; Heat rejection during low speed hill climbs – Higher operating temperature; Longer Idling times – Higher operating voltages and drier operation; Take into account different hybridization strategies (Vary size of battery).

30 DIRECT ENERGY CONVERSION↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Composite PEMs from Electrospun Crosslinkable Poly(Phenylene Sulfonic Acid)s (Final Technical Report)

The main objective of this project is to fabricate and demonstrate superior fuel cell performance of an electrospun composite all-hydrocarbon, non-PFSA membrane. The project builds on two earlier, DOE-funded studies demonstrating high proton conductivity, even at very low humidity of crosslinkable poly(phenylenesulfonic acid), cPPSA, solution cast films, and high durability of electrospun perfluorosulfonic acid (PFSA) composite membranes. Most project milestones were fully met but the best membrane conductivity and fuel cell performance were obtained with membranes that did not contain electrospun sulfonated polyphenylene, as initially planned. Instead, an excellent performance was achieved with membranes fabricated by pore-filling, either with electrospun poly(phenyl sulfone) scaffolds or with commercial, expanded polytetrafluoroethylene scaffolds. Fuel cell testing demonstrated performance better than that of Nafion 211 or Nafion XL, particularly at lower cell humidification levels with significantly lower hydrogen crossover. No accelerated stress testing was performed, due to the initial numerous difficulties with controlling the copolymerization reaction, which took excessive amount of time to overcome. Potential scale-up of the proposed composite membrane technology can aid in boosting the fuel cell power output and simplification of the cell hydration system.

08 HYDROGEN↗

Durable Fuel Cell MEA through Immobilization of Catalyst Particle and Membrane Chemical Stabilizer

For hydrogen-based fuel cell electric vehicle to be cost competitive with the incumbent diesel-powered internal combustion engine heavy-duty vehicle, the total cost of ownership of the truck must be decreased via both capital cost and the operating cost (H 2 fuel expense) reduction. This puts the emphasis on the decrease of fuel cell stack cost via use of low platinum catalyst material usage to decrease capital cost, high H 2 fuel efficiency and high stack durability to decrease the operating cost. US DOE has set a target of ≤ 0.25 mgPt/cm 2 total loading in the membrane electrode assembly, high fuel efficiency of > 68% and a HD-combined target of ≥ 2.5 kW/gPGM after running an accelerated stress test (AST) equivalent to 30,000 hours of heavy-duty fuel cell operation.

08 HYDROGEN↗

Metallization failures

Metallization-related failure mechanisms were shown to be a major cause of integrated circuit failures under accelerated stress conditions, as well as in actual use under field operation. The integrated circuit industry is aware of the problem and is attempting to solve it in one of two ways: (1) better understanding of the aluminum system, which is the most widely used metallization material for silicon integrated circuits both as a single level and multilevel metallization, or (2) evaluating alternative metal systems. Aluminum metallization offers many advantages, but also has limitations particularly at elevated temperatures and high current densities. As an alternative, multilayer systems of the general form, silicon device-metal-inorganic insulator-metal, are being considered to produce large scale integrated arrays. The merits and restrictions of metallization systems in current usage and systems under development are defined.

Beatty, R.↗

Contributions of the space program to our knowledge of motion sickness.

A slow rotation room (SRR) was used in a laboratory setting to study experimental motion sickness. This SRR simulates, to some degree, the conditions on a rotating spacecraft. Habitability of the chamber was ascertained by subjects who remained in the room for over a month with experimenters in attendance. Control over stressful accelerations involved regulation of the room's angular velocity and the subject's head rotations. By standardizing the head rotations, the strength of the disturbing stimulus became a function of the room's angular velocity. Mild acute episodes of motion sickness were readily kept under control. Certain techniques demonstrated that a subject's susceptibility may be expressed in terms of the number of head motions at a particular angular velocity to reach a chosen endpoint. Investigations using prolonged exposure used rapid increase in rpm to terminal velocity to evoke symptoms, or incremental increase to terminal velocity to prevent them. The effectiveness of 16 representative antimotion sickness drugs is discussed.

Graybiel, A.↗

Prevention of experimental motion sickness by scopolamine absorbed through the skin

A double-blind placebo-controlled study compared the efficacy of the antimotion sickness drug scopolamine when administered by oral or transdermal routes. A secondary purpose was to extend our bioassay involving fixed-dose combinations of the homergic drugs promethazine and ephedrine. After receiving 12 apparently identical drug-placebo treatments, eight normal male students were exposed in a slow rotation room to stressful accelerations generated by their execution of 40 head movements out of the plane of the room's rotation at 1 rpm and at 1-rpm increments until either symptoms were experienced (just short of frank motion sickness) or the 27-rpm ceiling on the test was reached. Efficacy of a drug was defined in terms of the placebo-range and categorized as beneficial, inconsequential, or detrimental. The only detrimental effect was with scopolamine given orally. It is concluded that the advantages of the transdermal scopolamine, which include minimal side effects and prolonged effectiveness, deserve full exploitation.

Graybiel, A.↗

Motion sickness susceptibility during rotation at 30 rpm in free-fall parabolic flight

To make comparisons with experimental motion sickness susceptibility in Skylab missions, subjects were tested during free fall in parabolic flight and in ground-based simulation tests. They were rotated at 30 rpm in a rotating litter chair (RLC) with head fixed, head swiveling left-to-right, or with 90 degree forward and return head and body movements. Stressful accelerations similar to those in the Skylab RLC were generated only in the tests aloft, where subjects who made 'forward and return' movements (generating cross-coupled angular accelerations) were substantially more prone to motion sickness than those with either head fixed or head swiveling left-to-right. However, with head swiveling, susceptibility was slightly higher in the laboratory than aloft.

Graybiel, A.↗

Experimental motion sickness - Efficacy of transdermal scopolamine plus ephedrine

A double-blind, placebo-controlled study compared the efficacy of transdermal therapeutic system-scopolamine administered alone and combined with ephedrine sulfate given orally in doses of 12.5, 25, and 50 mg. Eight normal male students were exposed to stressful accelerations in a slow-rotation room after receiving 10 apparently identical treatments comprising the four drugs and six placebos. Efficacy of the drug was defined in terms of the placebo range and categorized as beneficial, inconsequential, or detrimental. None of the effects was detrimental. Overall beneficial effects were 60% for transdermal therapeutic system-scopolamine (plus placebo) and 57% for the three transdermal therapeutic system-scopolamine plus ephedrine combinations.

Graybiel, A.↗

Module degradation catalyzed by metal-encapsulation reactions

Four major properties are considered to be relevant in determining service life of a photovoltaic module: (1) Mechanical: creep resistance, modulus, tensile strength; (2) Optical: integrated transmission at 0.4 to 1.1 m wavelength; (3) Chemical: inertness with respect to metals and other components, retention of stabilizers, etc. and (4) Electrical; maintaining effective isolation of conductive components. These properties were measured after exposing polymer specimens to three types of accelerated stress: thermal, ultraviolet radiation and metal catalysts. These conditions give rise to a large number of complex interrelated free-radical reactions that result in the deterioration of polymeric materials.

Gallagher, B. D.↗