SEARCH · Search NASA
Results for “Accelerators, Instrumentation”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Beam energy and diameter diagnostics for ASD Scorpius commissioning
Explore the source record for details and available documents.
Modeling and Simulations of Electron Emission from Diamond-Amplified Cathodes
Emission of electrons from a diamond-amplified cathode was recently demonstrated. This experiment was based on a promising new concept for generation of high-current, high-brightness, and low thermal emittance electron beams. The measurements from transmission and emission experiments have shown the potential to realize the diamond-amplified cathode concept. However, the results indicate that the involved physical properties should be understood in greater detail to build diamond cathodes with optical properties. We have already made progress in understanding the secondary electron generation and charge transport in diamond with the models we implemented in the VORPAL computational framework. We have been implementing models for electron emission from diamond and will present results from 3D VORPAL simulations with the integrated capabilities on generating electrons and holes, initiated by energetic primary electrons, propagation of the charge clouds, and then the emission of electrons into diamond. We will discuss simulation results on the dependence of the electron emission on diamond surface properties.
Charge Lifetime Study of K2CsSb Photocathode Inside a JLAB DC High Voltage Gun
Two photocathodes are frequently considered for generating high average current electron beams and/or beams with high brightness for current and future accelerator applications: GaAs:Cs and K2CsSb. Each photocathode has advantages and disadvantages, and need to demonstrate performance at 'production' accelerator facilities. To this end a K2CsSb photocathode was manufactured at Brookhaven National Lab and delivered to Jefferson Lab within a compact vacuum apparatus at pressure {approx} 5 x 10{sup -11} Torr. This photocathode was installed inside a dc high voltage photogun biased at voltages up to 200 kV, and illuminated with laser light at 440 or 532 nm, to generate beams up to 20 mA. Photocathode charge lifetime measurements indicate that under some conditions this cathode has exceptionally high charge lifetime, without measurable QE decay, even from the center of the photocathode where operation using GaAs photocathodes is precluded due to ion bombardment. These studies also suggest a complex QE decay mechanism likely related to chemistry and localized heating via the laser beam.
Generation of Coherent X-Ray Radiation through Modulation Compression
In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulator, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of 1 + h{sub b}R{sub 56}{sup a} in phase space, where h{sub b} is the energy bunch length chirp introduced by the laser chirper, R{sub 56}{sup a} is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 attoseconds pulse, 1 nm coherent X-ray radiation using a 60 A electron beam out of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.
Ultra-High Gradient S-Band Linac for Laboratory And Industrial Applications
A strong demand for high gradient structures arises from the limited real estate available for linear accelerators. RadiaBeam Technologies is developing a Doubled Energy Compact Accelerator (DECA) structure: an S-band standing wave electron linac designed to operate at accelerating gradients of up to 50 MV/m. In this paper, we present the radio-frequency design of the DECA S-band accelerating structure, operating at 2.856 GHz in the {pi}-mode. The structure design is heavily influenced by NLC collaboration experience with ultra high gradient X-band structures; S-band, however, is chosen to take advantage of commonly available high power S-band klystrons.
Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun
In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.
Simulations of Surface Effects and Electron Emission from Diamond-Amplifier Cathodes
Emission of electrons in diamond experiments based on the promising diamond-amplifier concept was recently demonstrated. Transmission mode experiments have shown the potential to realize over two orders of magnitude charge amplification. However, the recent emission experiments indicate that surface effects should be understood in detail to build cathodes with optimal properties. We have made progress in understanding secondary electron generation and charge transport in diamond with models we implemented in the VORPAL particle-in-cell computational framework. We introduce models that we have been implementing for surface effects (band bending and electron affinity), charge trapping, and electron emission from diamond. Then, we present results from 3D VORPAL diamond-vacuum simulations with the integrated capabilities on generating electrons and holes, initiated by energetic primary electrons, charge transport, and then emission of electrons from diamond into vacuum. Finally, we discuss simulation results on the dependence of the electron emission on diamond surface properties.
First Demonstration of Electron Beam Generation and Characterization With an All Superconducting Radio-Frequency (SRF) Photoinjector
In preparation for a high brightness, high average current electron source for the energy recovery linac BERLinPro an all superconducting radio-frequency (SRF) photoinjector is now in operation at Helmholtz-Zentrum Berlin. The aim of this experiment is beam demonstration with a high brightness electron source able to generate short, few ps long pulse length electron bunches from a superconducting (SC) cathode film made of Pb coated on the backplane of a Nb SRF cavity. This paper describes the setup of the experiment, first results from beam measurements and capabilities of the source derived from beam dynamics considerations. In April 2011 the photoinjector generated and accelerated for the first time electron beam. This result marks the highlight of the project running for two years starting with project approval in May 2009.
First Characterization of a Fully Superconducting RF Photoinjector Cavity
As a first step towards a high brightness, high average current electron source for the BERLinPro ERL a fully superconducting photo-injector was developed by HZB in collaboration with Jefferson Laboratory, DESY and the A. Soltan Institute. This cavity-injector ensemble is made up of a 1.6-cell superconducting cavity with a superconducting lead cathode deposited on the half-cell backwall. A superconducting solenoid is used for emittance compensation. This system, including a diagnostics beamline, has been installed in the HoBiCaT facility to serve as a testbed for beam dynamics studies and to test the combination SRF cavity and superconducting solenoid. This paper summarizes the characterization of the cavity in this configuration including Q measurements, dark current tests and field-stability analyzes.
EVALUATION OF SILICON DIODES AS IN-SITU CRYOGENIC FIELD EMISSION DETECTORS FOR SRF CAVITY DEVELOPMENT
We performed in-situ cryogenic testing of four silicon diodes as possible candidates for field emission (FE) monitors of superconducting radio frequency (SRF) cavities during qualification testing and in accelerator cryo-modules. We evaluated diodes from 2 companies - from Hamamatsu corporation model S1223-01; and from OSI Optoelectronics models OSD35-LR-A, XUV-50C, and FIL-UV20. The measurements were done by placing the diodes in superfluid liquid helium near the top of a field emitting 9-cell cavity during its vertical test. For each diode, we will discuss their viability as a 2K cryogenic detector for FE mapping of SRF cavities and the directionality of S1223-01 in such environments. We will also present calibration curves between the diodes and JLab's standard radiation detector placed above the Dewar's top plate.
The Tri-modal Imager: Imaging and Source Identification at Standoff Distances
No abstract prepared.
Diamond X-ray Beam Position Monitors
Modern Synchrotrons are capable of significant per-pulse x-ray flux, and time resolved pulse-probe experiments have become feasible. These experiments provide unique demands on x-ray monitors, as the beam position, flux and arrival time all potentially need to be recorded for each x-ray pulse. Further, monitoring of white x-ray beam position and flux upstream of beamline optics is desirable as a diagnostic of the electron source and insertion device alignment. We report on diamond quadrant monitors which provide beam diagnostics for a variety of applications, for both white and monochromatic beams. These devices have a position resolution of 25 nm for a stable beam, are linear in flux over at least 11 orders of magnitude, and can resolve beam motion shot-by-shot at repetition rates up to 6.5 MHz.
High Efficiency Visible Photocathode Development
The alkali antimonides are of significant interest to the accelerator community, as they have a high quantum efficiency (QE) under illumination by green light. These cathodes are attractive for high-average-current photoinjector applications and understanding their fundamental properties are critical to the production of long lived, reliable cathodes. We report on ongoing work to characterize cathode formation during growth. In-situ X-ray Diffraction (XRD) has been used to compare grain size and texture in antimony layers, and X-ray Photoelectron Spectroscopy (XPS) has been used to investigate the solid-state chemistry of cathode formation.
Detector positioning for the initial subcriticality level determination in accelerator-driven systems
Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)
Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets
Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.
Microgravity acceleration measurement and environment characterization science (17-IML-1)
The Space Acceleration Measurement System (SAMS) is a general purpose instrumentation system designed to measure the accelerations onboard the Shuttle Orbiter and Shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigation into the microgravity environment of the vehicle. Acceleration measurements can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The prime objective for SAMS on the International Microgravity Lab (IML-1) mission will be to measure the accelerations experienced by the Fluid Experiment System (FES). The SAMS acceleration measurements for FES will be complemented by low level, low frequency acceleration measurements made by the Orbital Acceleration Research Experiment (OARE) installed on the shuttle. Secondary objectives for SAMS will be to measure accelerations at several specific locations to enable the acceleration transfer function of the Spacelab module to be analyzed. This analysis effort will be in conjunction with similar measurements analyses on other Spacelab missions.
MUSETT and the Spectroscopy of Heavy Elements at GANIL
The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.