Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy

Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected in real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast neural network training on a cluster of GPUs for action recognition with high accuracy

In this work, we propose algorithms and techniques to accelerate training of deep neural networks for action recognition on a cluster of GPUs. The convergence analysis of our algorithm shows it is possible to reduce communication cost and at the same time minimize the number of iterations needed for convergence. We customize the Adam optimizer for our distributed algorithm to improve efficiency. In addition, we employ transfer-learning to further reduce training time while improving validation accuracy. For the UCF101 and HMDB51 datasets, the validation accuracies achieved are 93.1% and 67.9% respectively. With an additional end-to-end trained temporal stream, the validation accuracies achieved for UCF101 and HMDB51 are 93.47% and 81.24% respectively. As far as we know, these are the highest accuracies achieved with the two-stream approach using ResNet that does not involve computationally expensive 3D convolutions or pretraining on much larger datasets.

97 MATHEMATICS AND COMPUTING↗

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-accuracy Geant4 simulation and semi-analytical modeling of nuclear resonance fluorescence

Nuclear resonance fluorescence (NRF) is a photonuclear interaction that enables highly isotope-specific measurements in both pure and applied physics scenarios. High-accuracy design and analysis of NRF measurements in complex geometries is aided by Monte Carlo simulations of photon physics and transport, motivating Jordan and Warren (2007) to develop the G4NRF codebase for NRF simulation in Geant4. In this work, we enhance the physics accuracy of the G4NRF code and perform improved benchmarking simulations. The NRF cross section calculation in G4NRF, previously a Gaussian approximation, has been replaced with a full numerical integration for improved accuracy in thick-target scenarios. A high-accuracy semi-analytical model of expected NRF count rates in a typical NRF measurement is then constructed and compared against G4NRF simulations for both simple homogeneous and more complex heterogeneous geometries. Furthermore, agreement between rates predicted by the semi-analytical model and G4NRF simulation is found at a level of ~1% in simple test cases and ~3% in more realistic scenarios, improving upon the ~20% level of the initial benchmarking study and establishing a highly-accurate NRF framework for Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing the Expense and Accuracy of Methods to Simulate Atomic Vibrations in Rubrene

Atomic vibrations can inform about materials properties from hole transport in organic semiconductors to correlated disorder in metal–organic frameworks. Currently, there are several methods for predicting these vibrations using simulations, but the accuracy–efficiency tradeoffs have not been examined in depth. In this work, rubrene is used as a model system to predict atomic vibrational properties using six different simulation methods: density functional theory, density functional tight binding, density functional tight binding with a Chebyshev polynomial-based correction, a trained machine learning model, a pretrained machine learning model called ANI-1, and a classical forcefield model. The accuracy of each method is evaluated by comparison to the experimental inelastic neutron scattering spectrum. All methods discussed here show some accuracy across a wide energy region, though the Chebyshev-corrected tight-binding method showed the optimal combination of high accuracy with low expense. We then offer broad simulation guidelines to yield efficient, accurate results for inelastic neutron scattering spectrum prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elevating density functional theory to chemical accuracy for water simulations through a density-corrected many-body formalism

Abstract Density functional theory (DFT) has been extensively used to model the properties of water. Albeit maintaining a good balance between accuracy and efficiency, no density functional has so far achieved the degree of accuracy necessary to correctly predict the properties of water across the entire phase diagram. Here, we present density-corrected SCAN (DC-SCAN) calculations for water which, minimizing density-driven errors, elevate the accuracy of the SCAN functional to that of “gold standard” coupled-cluster theory. Building upon the accuracy of DC-SCAN within a many-body formalism, we introduce a data-driven many-body potential energy function, MB-SCAN(DC), that quantitatively reproduces coupled cluster reference values for interaction, binding, and individual many-body energies of water clusters. Importantly, molecular dynamics simulations carried out with MB-SCAN(DC) also reproduce the properties of liquid water, which thus demonstrates that MB-SCAN(DC) is effectively the first DFT-based model that correctly describes water from the gas to the liquid phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of Lagrange-sinc functions as a basis set for electronic structure calculations of atoms and molecules

We developed a self-consistent field program based on Kohn-Sham density functional theory using Lagrange-sinc functions as a basis set and examined its numerical accuracy for atoms and molecules through comparison with the results of Gaussian basis sets. The result of the Kohn-Sham inversion formula from the Lagrange-sinc basis set manifests that the pseudopotential method is essential for cost-effective calculations. The Lagrange-sinc basis set shows faster convergence of the kinetic and correlation energies of benzene as its size increases than the finite difference method does, though both share the same uniform grid. Using a scaling factor smaller than or equal to 0.226 bohr and pseudopotentials with nonlinear core correction, its accuracy for the atomization energies of the G2-1 set is comparable to all-electron complete basis set limits (mean absolute deviation ≤1 kcal/mol). The same basis set also shows small mean absolute deviations in the ionization energies, electron affinities, and static polarizabilities of atoms in the G2-1 set. In particular, the Lagrange-sinc basis set shows high accuracy with rapid convergence in describing density or orbital changes by an external electric field. Moreover, the Lagrange-sinc basis set can readily improve its accuracy toward a complete basis set limit by simply decreasing the scaling factor regardless of systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Turning a pyroelectric infrared motion sensor into a high-accuracy presence detector by using a narrow semi-transparent chopper

Pyroelectric infrared (PIR) sensors are the most popular presence detectors. However, their applications are limited to motion detection only, as the pyroelectric sensing element is only sensitive to radiated heat power fluctuation. Here, this letter reports a chopped PIR (C-PIR) presence sensor, capable of detecting both the stationary and the moving occupants at high accuracy by introducing a narrow semi-transparent optical chopper to shutter the incident radiation periodically. More importantly, even though the narrow chopper can efficiently shutter the unidirectional infrared (IR) power radiated by stationary occupants, it has near-zero influence on the omnidirectional power radiated from the ambient environment. Therefore, the voltage difference generated by the C-PIR sensor between occupied and unoccupied scenarios can be directly used for identifying the presence of stationary occupants with high-accuracy. For moving occupant detection, the optical chopper can barely affect the variation of the radiated power and thus lead to the same high-accuracy detection as the on-board PIR. An approximate theoretical model is created to illustrate the physics and dynamics of IR radiation shuttered by the optical chopper. Parametric studies, experimental characterization, and empirical analysis were performed to obtain the optimal setting of the chopper in terms of its thickness and chopping frequency. Experimental results reveal that the C-PIR sensor can detect stationary occupants for up to 4.0 m and moving occupants for up to 8.0 m, while maintaining an accuracy of 100%. The field of view of the C-PIR was found at 110° horizontally and 90° vertically, consistent with that of the on-board PIR sensor.

47 OTHER INSTRUMENTATION↗

Accuracy of the explicit energy-conserving particle-in-cell method for under-resolved simulations of capacitively coupled plasma discharges

The traditional explicit electrostatic momentum-conserving particle-in-cell algorithm requires strict resolution of the electron Debye length to deliver numerical stability and accuracy. The explicit electrostatic energy-conserving particle-in-cell algorithm alleviates this constraint with minimal modification to the traditional algorithm, retaining its simplicity, ease of parallelization, and acceleration on modern supercomputing architectures. In this article, we apply the algorithm to model a one-dimensional radio frequency capacitively coupled plasma discharge relevant to industrial applications. The energy-conserving approach closely matches the results from the momentum-conserving algorithm and retains accuracy even for cell sizes up to 8 times the electron Debye length. For even larger cells, the algorithm loses accuracy due to poor resolution of steep gradients within the radio frequency sheath. Accuracy can be recovered by adopting a non-uniform grid, which resolves the sheath and allows for cell sizes up to 32 times the electron Debye length in the quasi-neutral bulk of the discharge. The effect is an up to 8 times reduction in the number of required simulation cells, an improvement that can compound in higher-dimensional simulations. We therefore consider the explicit energy-conserving algorithm as a promising approach to significantly reduce the computational cost of full-scale device simulations and a pathway to delivering kinetic simulation capabilities of use to industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the accuracy of compressibility transformations

This study highlights the importance of satisfying the eddy viscosity equivalence below the logarithmic layer, to deriving accurate compressibility transformations. First, we analyze the ability of known transformations to satisfy the eddy viscosity equivalence and show that the accuracy of these transformations is strongly dependent on this ability. Second, in a step-by-step manner, we devise new transformations that satisfy this hypothesis. An approach based on curve fitting of the incompressible Direct Numerical Simulation data for eddy viscosity profiles below the logarithmic layer provides an extremely accurate transformation, which motivates self-contained methods, making use of mixing length formulas in the inner region. It is shown that the accuracy of existing transformations can be significantly improved by applying these ideas, below the logarithmic layer. Motivated by the effectiveness of the formulations derived from eddy viscosity equivalence, we introduce a new integral transformation based on Reynolds number equivalence between compressible and incompressible flows. This approach is based on defining a new compressible velocity scale, which affects the accuracy of transformations. Several choices for the velocity scale are tested, and in each attempt, it is shown that the eddy viscosity equivalence plays a very important role for the accuracy of compressibility transformations.

42 ENGINEERING↗

Exploiting regulatory heterogeneity to systematically identify enhancers with high accuracy

Identifying functional enhancer elements in metazoan systems is a major challenge. Large-scale validation of enhancers predicted by ENCODE reveal false-positive rates of at least 70%. We used the pregrastrula-patterning network of Drosophila melanogaster to demonstrate that loss in accuracy in held-out data results from heterogeneity of functional signatures in enhancer elements. We show that at least two classes of enhancers are active during early Drosophila embryogenesis and that by focusing on a single, relatively homogeneous class of elements, greater than 98% prediction accuracy can be achieved in a balanced, completely held-out test set. The class of well-predicted elements is composed predominantly of enhancers driving multistage segmentation patterns, which we designate segmentation driving enhancers (SDE). Prediction is driven by the DNA occupancy of early developmental transcription factors, with almost no additional power derived from histone modifications. We further show that improved accuracy is not a property of a particular prediction method: after conditioning on the SDE set, naïve Bayes and logistic regression perform as well as more sophisticated tools. Applying this method to a genome-wide scan, we predict 1,640 SDEs that cover 1.6% of the genome. An analysis of 32 SDEs using whole-mount embryonic imaging of stably integrated reporter constructs chosen throughout our prediction rank-list showed >90% drove expression patterns. We achieved 86.7% precision on a genome-wide scan, with an estimated recall of at least 98%, indicating high accuracy and completeness in annotating this class of functional elements.

54 ENVIRONMENTAL SCIENCES↗

Measuring, Quantifying, and Predicting the Cost-Accuracy Tradeoff

Exponentially increasing data volumes, coupled with new modes of analysis have created significant new opportunities for data scientists. However, the stochastic nature of many data science techniques results in tradeoffs between costs and accuracy. For example, machine learning algorithms can be trained iteratively and indefinitely with diminishing returns in terms of accuracy. In this paper we explore the cost-accuracy tradeoff through three representative examples: we vary the number of models in an ensemble, the number of epochs used to train a machine learning model, and the amount of data used to train a machine learning model. We highlight the feasibility and benefits of being able to measure, quantify, and predict cost-accuracy tradeoffs by demonstrating the presence and usability of these tradeoffs in two different case studies.

big data analytics↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Impact of leaf motion constraints on IMAT plan quality, deliver accuracy, and efficiency

Purpose: Intensity modulated arc therapy (IMAT) is a radiation therapy delivery technique that combines the efficiency of arc based delivery with the dose painting capabilities of intensity modulated radiation therapy (IMRT). A key challenge in developing robust inverse planning solutions for IMAT is the need to account for the connectivity of the beam shapes as the gantry rotates from one beam angle to the next. To overcome this challenge, inverse planning solutions typically impose a leaf motion constraint that defines the maximum distance a multileaf collimator (MLC) leaf can travel between adjacent control points. The leaf motion constraint ensures the deliverability of the optimized plan, but it also impacts the plan quality, the delivery accuracy, and the delivery efficiency. In this work, the authors have studied leaf motion constraints in detail and have developed recommendations for optimizing the balance between plan quality and delivery efficiency. Methods: Two steps were used to generate optimized IMAT treatment plans. The first was the direct machine parameter optimization (DMPO) inverse planning module in the Pinnacle{sup 3} planning system. Then, a home-grown arc sequencer was applied to convert the optimized intensity maps into deliverable IMAT arcs. IMAT leaf motion constraints were imposed using limits of between 1 and 30 mm/deg. Dose distributions were calculated using the convolution/superposition algorithm in the Pinnacle{sup 3} planning system. The IMAT plan dose calculation accuracy was examined using a finer sampling calculation and the quality assurance verification. All plans were delivered on an Elekta Synergy with an 80-leaf MLC and were verified using an IBA MatriXX 2D ion chamber array inserted in a MultiCube solid water phantom. Results: The use of a more restrictive leaf motion constraint (less than 1-2 mm/deg) results in inferior plan quality. A less restrictive leaf motion constraint (greater than 5 mm/deg) results in improved plan quality but can lead to less accurate dose distribution as evidenced by increasing discrepancies between the planned and the delivered doses. For example, the results from our patient-specific quality assurance measurements demonstrated that the average gamma analysis passing rate decreased from 98% to 80% when the allowable leaf motion increased from 3 to 20 mm/deg. Larger leaf motion constraints also led to longer treatment delivery times (2 to 4 folds) due to the additional MLC leaf motion. Conclusions: Leaf motion constraints significantly impact IMAT plans in terms of plan quality, delivery accuracy, and delivery efficiency with the impact magnified for more complex cases. Our studies indicate that a leaf motion constraint of 2 to 3 mm/deg of gantry rotation can provide an optimal balance between plan quality, delivery accuracy, and efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Holistic Algorithmic Approach to Improving Accuracy, Robustness, and Computational Efficiency for Atmospheric Dynamics

Atmospheric weather and climate models must perform simulations very quickly to be useful. Therefore, modelers have traditionally focused on reducing computations as much as possible. However, in our new era of increasingly compute-capable hardware, data movement is now the prohibiting expense. This study examines the computational benefits of a new algorithmic approach to modeling atmospheric dynamics on scales relevant to weather and climate simulation. Rather than minimizing computations, this new approach considers the larger problem more holistically, including spatial accuracy, temporal accuracy, robustness (i.e., oscillations), on-node efficiency, and internode data transfers together at once. Numerical experiments demonstrate how computations can be strategically increased to simultaneously address each of these constraints while reducing data movement to adapt to modern accelerated hardware. The new algorithm can achieve at times up to 80% peak floating point throughput in single precision on the Nvidia Tesla V100 GPU, where the traditional approach is shown to only achieve single-digit floating point efficiency. Further, the new algorithm is twice as fast as a standard Runge--Kutta time integrator, and high-order accuracy with Weighted Essentially Non-Oscillatory (WENO) limiting came at less than 30% additional runtime cost on a GPU, thus increasing the accuracy per degree of freedom.

54 ENVIRONMENTAL SCIENCES↗

Improving the Accuracy of the Chebyshev Rational Approximation Method Using Substeps

The Chebyshev Rational Approximation Method (CRAM) for solving the decay and depletion of nuclides is shown to have a remarkable decrease in error when advancing the system with the same time step and microscopic reaction rates as the previous step. This property is exploited here to achieve high accuracy in any end-of-step solution by dividing a step into equidistant sub-steps. The computational cost of identical substeps can be reduced significantly below that of an equal number of regular steps, as the LU decompositions for the linear solves required in CRAM only need to be formed on the first substep. The improved accuracy provided by substeps is most relevant in decay calculations, where there have previously been concerns about the accuracy and generality of CRAM. Lastly, with substeps, CRAM can solve any decay or depletion problem with constant microscopic reaction rates to an extremely high accuracy for all nuclides with concentrations above an arbitrary limit.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Evaluating E. coli genome‐scale metabolic model accuracy with high‐throughput mutant fitness data

Abstract The Escherichia coli genome‐scale metabolic model (GEM) is an exemplar systems biology model for the simulation of cellular metabolism. Experimental validation of model predictions is essential to pinpoint uncertainty and ensure continued development of accurate models. Here, we quantified the accuracy of four subsequent E. coli GEMs using published mutant fitness data across thousands of genes and 25 different carbon sources. This evaluation demonstrated the utility of the area under a precision–recall curve relative to alternative accuracy metrics. An analysis of errors in the latest (iML1515) model identified several vitamins/cofactors that are likely available to mutants despite being absent from the experimental growth medium and highlighted isoenzyme gene‐protein‐reaction mapping as a key source of inaccurate predictions. A machine learning approach further identified metabolic fluxes through hydrogen ion exchange and specific central metabolism branch points as important determinants of model accuracy. This work outlines improved practices for the assessment of GEM accuracy with high‐throughput mutant fitness data and highlights promising areas for future model refinement in E. coli and beyond.

59 BASIC BIOLOGICAL SCIENCES↗