SEARCH · Search NASA
Results for “Active Controls”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Dissecting protein tyrosine phosphatase signaling by engineered chemogenetic control of its activity
Protein tyrosine phosphatases (PTPases) are critical mediators of dynamic cell signaling. A tool capable of identifying transient signaling events downstream of PTPases is essential to understand phosphatase function on a physiological time scale. We report a broadly applicable protein engineering method for allosteric regulation of PTPases. This method enables dissection of transient events and reconstruction of individual signaling pathways. Implementation of this approach for Shp2 phosphatase revealed parallel MAPK and ROCK II dependent pathways downstream of Shp2, mediating transient cell spreading and migration. Furthermore, we show that the N-SH2 domain of Shp2 regulates MAPK-independent, ROCK II-dependent cell migration. Engineered targeting of Shp2 activity to different protein complexes revealed that Shp2-FAK signaling induces cell spreading whereas Shp2-Gab1 or Shp2-Gab2 mediates cell migration. We identified specific transient morphodynamic processes induced by Shp2 and determined the role of individual signaling pathways downstream of Shp2 in regulating these events. Broad application of this approach is demonstrated by regulating PTP1B and PTP-PEST phosphatases.
WHOC (Wind Hybrid Open Controller) [SWR-25-54]
The Wind Hybrid Open Controller (WHOC) is a python-based tool for real-time plant-level wind farm control and wind-based hybrid plant control. WHOC is primarily run in simulation, although we intend that it could be used for physical plants in future. WHOC provides simple farm-level (and hybrid plant-level) controls such as wake steering control, spatial filtering/consensus, active power control, and coordinated control of hybrid power plant assets; and creates an entry point for the development of more advanced controllers.
Active Light-Controlled Frontal Ring-Opening Metathesis Polymerization
Frontal ring-opening metathesis polymerization (FROMP) is a self-propagating, energy-efficient polymerization method used to fabricate polymeric materials. This dataset describes a photochemical approach for controlling the FROMP of dicyclopentadiene (DCPD). A photobase generator is used to inhibit polymerization under 365 nm light, while a photosensitizer combined with a co-initiator enables acceleration of the reaction under 470 nm light. Together, these components provide orthogonal, light-meditated control over front velocity.
Cold electron measurements with active S/C potential control [Slide]
Abstract not provided.
End-to-end analysis of active wake control-induced flow instabilities in a stable ABL
Explore the source record for details and available documents.
Magnetospheric cold plasma measurements using active spacecraft potential control techniques.
Explore the source record for details and available documents.
Magnetospheric cold plasma measurements using active spacecraft potential control techniques
Explore the source record for details and available documents.
Magnetospheric cold plasma measurements using active spacecraft potential control techniques
Explore the source record for details and available documents.
Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters
This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.
Error field correction strategies in preparation to MAST-U operation
In magnetic fusion devices, unwanted non-axisymmetric magnetic field perturbations, known as error fields (EF), can have detrimental effects on plasma stability and confinement. Such EFs may originate from several sources, such as axi-symmetric coil misalignments, coil feeds, 3D structures in the wall surrounding the plasma, presence of ferromagnetic materials near the plasma surface, blanket materials in future devices. To minimize their impact on plasma performance and on the available operational space, it is important to identify the EF sources and develop EF control strategies. MAST Upgrade (MAST-U) is a spherical tokamak which will operate in the near future after a series of enhancements from the previous MAST experiment. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal eld (P) and divertor (D) coils. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal field (P) and divertor (D) coils, whose magnetic eld measurements were available when writing this paper. Such measurements reveal that P and D coils are 3D deformed and thus are responsible for intrinsic EFs, with mainly n=1 and n=2 toroidal mode numbers. In preparation to MAST-U operation, both passive and active EF control strategies have been adopted for n=1 and n=2 EFs compensation. Passive EF control consisted of installing finely each D and P coil within MAST-U device so as to minimize the intrinsic n=1 EF amplitude. The optimal coil alignment has been determined based on magnetic eld measurements and the corresponding 3D electro-magnetic modelling, and envisaged coil shift and tilt of 3.2 mm and 0.7 mrad, respectively, in the case of P coil named P4. Conversely, active control will be use during MAST-U operation to reduce the n=2 EF which is associated mainly with P4 and P5, as well. Since these coils have been re-used from the MAST device, studies attempting n=2 EF control, based on MAST plasmas, have been modelled utilizing the MARS-F code to interpret experimental results in MAST and to give hints for future n=2 EF control studies in MAST-U. Here, a model-based control set for n=2 EF control has been identified which would allow for the minimization of rotation braking, of the resonant magnetic field at the q=2 and of the plasma displacement in MAST-U, simultaneously.
Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems
This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.
Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends
Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.
Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters
High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.
Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint
High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.
Control, Operation, and Stability Characteristics of Grid-Forming Type III Wind Turbines: Preprint
This paper explores the control, operation, and stability characteristics of grid-forming Type III wind turbines. The paper shows that the grid-forming operation mode requires redesign of only the slower control loops for active and reactive power control, whereas the faster current control implementation can stay the same as grid-following turbines. The paper also shows that grid-forming wind turbines face higher mechanical stress than grid-following wind turbines because of the slower speed of the active power control. This stress, however, can be mitigated using advanced pitch control. The paper compares the stability characteristics of the grid-forming and grid-following operation modes of Type III turbines by comparing sequence impedance responses for both operation modes. It is found that, unlike standard Type III wind turbines, the grid-forming mode substantially reduces the risks of subsynchronous oscillations during operation with series-compensated transmission lines. Moreover, the grid-forming Type III turbines can operate stably with extremely weak grids. The findings of this paper are validated using EMT-PSCAD simulations of a 2.5-MW turbine operating in both grid-forming and grid-following modes.