Search NASASearch

SEARCH · Search NASA

Results for “Active Thermal Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

713 records · Page 13

Dressed-State Hamiltonian Engineering in a Strongly Interacting Solid-State Spin Ensemble

In quantum science applications, ranging from many-body physics to quantum metrology, dipolar interactions in spin ensembles are often controlled via Floquet engineering. However, this technique typically reduces the interaction strength between spins and effectively weakens the coupling to a target sensing field, limiting the metrological sensitivity. In this Letter, we develop and demonstrate an alternative method that directly tunes the native dipolar interaction in an ensemble of nitrogen-vacancy (NV) centers in diamond, thereby overcoming these limitations inherent to Floquet engineering. Our approach utilizes dressed-state qubit encoding under a bias magnetic field applied perpendicular to the crystal lattice orientation. This method leads to a 3.2× enhancement of the dimensionless coherence parameter JT 2 compared to state-of-the-art Floquet engineering and a 2.6× (8.3 dB) enhanced sensitivity in ac magnetometry. Furthermore, our results provide a powerful Hamiltonian engineering tool for future studies with NV ensembles and other interacting higher-spin (S > $\frac{1}{2}$) systems.

Quantum control

Reversible Ferroelectric Polarization Modulation of Chiral Molecular Ferroelectrics by Circularly Polarized Light

Abstract The optical modulation of ferroelectric polarization constitutes a transformative, non‐contact strategy for the precise manipulation of ferroelectric properties, heralding advancements in optically stimulated ferroelectric devices. Despite its potential, progress in this domain is constrained by material limitations and the intricate nature of the underlying mechanisms. Recent studies have achieved efficient regulation of ferroelectric polarization and thermal conductivity in chiral ferroelectric thin films through the application of left‐ and right‐handed circularly polarized light (LCP and RCP). Differential absorption of circularly polarized light (CPL) induces nonequilibrium carrier dynamics, generating distinctive interfacial electrostatic fields that enable precise control of ultrathin ferroelectric films. For (R)‐BINOL−DIPASi and (S)‐BINOL−DIPASi (C 26 H 26 O 2 Si), polarization changes surpass 23%, exhibiting opposite response under LCP and RCP excitation. In R chiral films, remnant polarization decreases from 1.05 µC cm − 2 under LCP to 0.85 µC cm − 2 under RCP, whereas in S chiral films, polarization increases from 0.85 µC cm − 2 under LCP to 0.98 µC cm − 2 under RCP. This reversible modulation facilitates reliable switching between ON and OFF states, presenting the potential of chiral ferroelectric materials for flexible, high‐speed integrated photonic sensor technologies.

Chemistry

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Nuclear Safety [Vol. 35, No. 1, January-June 1994]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: THE CHERNOBYL ACCIDENT: 1 Chernobyl Accident Management Actions, A. R Sich 25 The IAEA-ASSET Approach to Avoiding Accidents is to Recognize the Precursors to Prevent Incidents, F. Reisch; ACCIDENT ANALYSIS: 36 A Review of the Available Information on the Triggering Stage of a Steam Explosion, D. F. Fletcher; 58 Analysis and Modeling of Flow-Blockage-Induced Steam Explosion Events in the High-Flux Isotope Reactor, R. P. Taleyarkhan, V. Georgevich, C. W. Nestor, U. Gat, B. L. Lepard, D. H. Cook, J. Freels, S. J. Chang, C. Luttrell, R. C. Gwaltney, and J. Kirkpatrick; 74 An Analysis of Disassembling the Radial Reflector of a Thermionic Space Nuclear Reactor Power System, M. S. El-Genk and D. V. Paramonov; CONTROL AND INSTRUMENTATION: 86 Standards for High-Integrity Software, D. R. Wallace, D. R. Kuhn, L M. Ippolito, and L. Beltracchi; DESIGN FEATURES: 98 Adoption of New Design Features for the Next Generation Nuclear Power Reactors, L. S. Tong; 114 Review of Nuclear Piping Seismic Design Requirements, G. C. Slagis and S. E. Moore; ENVIRONMENTAL EFFECTS: 128 PC-Based Probabilistic Safety Assessment Study for a Geological Waste Repository Placed in a Bedded Salt Formation, S. A. Khan; OPERATING EXPERIENCES: 142 Managing Aging in Nuclear Power Plants: Insights from NRC’s Maintenance Team Inspection Reports, A. Fresco and M. Subudhi; 150 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 153 Selected Safety-Related Events, Compiled by G. A. Murphy; RECENT DEVELOPMENTS: 158 Reports, Standards, and Safety Guides, D. S. Queener; 168 Proposed Rule Changes as of Dec. 31, 1993; ANNOUNCEMENTS: 177 Symposium on Radioactive and Mixed Waste—Risk as a Basis for Waste Classification; 177 1995 Incineration Conference 178 Ninth Power Plant Dynamics Control and Testing Symposium; 174 The Authors

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development of a high fidelity CFD model for solvent evaporation and transport in porous structure during battery electrode drying

An efficient battery manufacturing process is the key to the mass production of Electric Vehicles (EV), in which drying is one of the most energy-intensive steps significantly influencing the battery cell performance. An accurate 3D CFD model for drying is essential for predicting the drying mechanism and optimizing its parameters. By optimizing the drying process, it is possible to reduce energy consumption and cost during battery manufacturing, minimize binder loading and maximize active material loading to achieve superior electrochemical performances and facilitate wider and faster public adoption of EV. This project aims to optimize the drying process during electrode manufacturing by leveraging high-fidelity, porous electrode simulations for solvent evaporation. By optimizing this process, we seek to reduce energy consumption during battery manufacturing, while minimizing binder loading and maximizing active material loading, with the overall goal of enhancing electrical vehicle performance.

Horner, Jeffrey Scott [Sandia National Laboratorie

TRACE Input Modernization

This work presents a Tom’s Obvious Minimal Language (TOML)-based representation of input for the US Nuclear Regulatory Commission’s TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics code. Implemented using the Workbench Analysis Sequence Processor (WASP), the approach maps traditional TRACE input structures to a hierarchical format composed of named parameters, typed values, and native data collections. The resulting representation preserves TRACE’s existing modeling capabilities while providing a modern, structured interface for model development and management. WASP further extends TOML through a file import directive that supports modular model composition and reusable input organization. In addition, WASP provides extended array data entry convenience with various data repeat and interpolation capabilities. Examples of the new TOML syntax are provided for major TRACE input categories, including hydraulic components, heat structures, control systems, and trip logic. The TOML representation establishes a foundation for improved validation, tooling, automation, and model maintainability while remaining compatible with existing TRACE workflows. To facilitate migration to the TOML-based input format, the TRACE executable now supports conversion of native TRACE input into an intermediate JSON representation. A Python utility subsequently transforms the JSON data into an equivalent TOML model. Lastly, the TRACE executable now supports execution using TOML-formatted input.

Lefebvre, Robert A. [Oak Ridge National Laboratory

Pivotal role of organic adsorbates for the creation of catalytic sites during dry reforming of methane

Inadvertent factors can sometimes be crucial for synthesis of catalysts. The use of polyalcohols is common in the synthesis of heterogeneous catalysts. Interactions between alcohols and heterogeneous catalysts have been shown to induce surface reconstructions that greatly impact catalytic performance. Thus, traces of these alcohol functionalities on the as-synthesized catalysts, combined with heat treatment, could be critical in the generation of catalytic sites. Here, we show that during the synthesis of a Ni–Mo/MgO catalyst using a polyol process, residual ethylene glycol (EG) on the surface plays a significant role in the generation of catalytic sites for dry reforming of methane (DRM). The as-synthesized catalyst presents dispersed cationic Ni. Under DRM reaction conditions, the presence of EG, and H2 generated in situ, promote the generation of co-localized Ni–Mo nanoparticles (NPs). Greater amount of EG in the as-synthesized catalyst prevented sintering, leading to better catalyst stability and higher rates. If the residual EG remaining post-synthesis is removed through calcination, before conducting DRM, NiO NPs are formed and the material is completely inactive for catalyzing the reaction. When using a different support, denoted MgO*, EG also proved indispensable to generate active sites, although Ni–Mo co-localization was not evident, and a combination of DRM-related species was needed to activate the catalyst, not just H2. This work systematically uncovers how the interactions between organic adsorbates, the supported metals and the catalyst support dictate the creation of catalytic active sites.

Polo Garzon, Felipe [ORNL] (ORCID:0000000265076183

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

Forge Internship at FAST-IOTA

Assisted FAST facility personal with various upgrades and system installation activities during the summer 2026 FAST-IOTA shutdown as a part of the FORGE internship program. Herein is a summary of my involvement in and the results of that experience.

DeCraene, Ryan [Unlisted, US, IL]

Flexible and Extensive Platinum Ion Gel Condensers for Programmable Catalysis

Catalytic condensers composed of ion gels separating a metal electrode from a platinum-on-carbon active layer were fabricated and characterized to achieve more powerful, high surface area dynamic heterogeneous catalyst surfaces. Ion gels comprised of poly(vinylidene difluoride)/1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide were spin coated as a 3.8 μm film on a Au surface, after which carbon sputtering of a 1.8 nm carbon film and electron-beam evaporation of 2 nm Pt clusters created an active surface exposed to reactant gases. Electronic characterization indicated that most charge condensed within the Pt nanoclusters upon application of a potential bias, with the condenser device achieving a capacitance of ∼20 μF/cm 2 at applied frequencies of up to 120 Hz. The maximum charge of ∼10 14 |e – | cm –2 was condensed under stable device conditions at 200 °C on catalytic films with ∼10 15 sites cm –2 . Grazing incidence infrared spectroscopy measured carbon monoxide adsorption isobars, indicating a change in the CO* binding energy of ∼19 kJ mol –1 over an applied potential bias of only 1.25 V. Condensers were also fabricated on flexible, large area Kapton substrates allowing stacked or tubular form factors that facilitate high volumetric active site densities, ultimately enabling a fast and powerful catalytic condenser that can be fabricated for programmable catalysis applications.

Catalysis

Divergent Rickettsia species exhibit distinct mechanisms of actin-based motility

Many Rickettsia species undergo actin-based motility to promote cell-cell spread during infection. Rickettsial genomes often encode two motility effectors, RickA and Sca2, which in the spotted fever group I species, Rickettsia parkeri act by activating the host Arp2/3 complex and by mimicking eukaryotic formins, respectively. The function of RickA and Sca2 orthologs in the distantly related species Rickettsia bellii was unclear. We report that R. bellii RickA activates the host Arp2/3 complex but has no discernible role in bacterial motility. The R. bellii Sca2 ortholog, Sca2/6, nucleates and elongates actin with a flexible structure and an unusual actin monomer-binding motif in a mechanism distinct from formins or other microbial actin nucleators. R. bellii motility is solely correlated with Sca2/6 localization and, compared with R. parkeri motility, is slow and meandering, generating distinctly organized actin tails. The evolutionary flexibility in the mechanism and regulation of rickettsial actin-based motility suggests similar adaptability for other microbes.

Bacher, Meghan C

Speciation of Transition Metal Dissolution in Electrolyte from Common Cathode Materials

Significant capacity loss has been observed across extended cycling of lithium-ion batteries cycled to high potential. One of the sources of capacity fade is transition metal dissolution from the cathode active material, ion migration through the electrolyte, and deposition on the solid-electrolyte interphase on the anode. While much research has been conducted on the oxidation state of the transition metal in the cathode active material or deposited on the anode, there have been limited investigations of the oxidation state of the transition metal ions dissolved in the electrolyte. Here, in this work, X-ray absorption spectroscopy has been performed on electrolytes extracted from cells built with four different cathode active materials (LiMn 2 O 4 (LMO), LiNi 0.5 Mn 1.5 O 4 (LNMO), LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811), and (x Li 2 MnO 3 *(1-x) LiNi a Mn b Co c O 2 , with a+b+c=1) (LMRNMC)) that were cycled at either high or standard potentials to determine the oxidation state of Mn and Ni in solution. Inductively coupled plasma-mass spectrometry has been performed on the anodes from these cells to determine the concentration of deposited transition metal ions. While transition metal ions were found dissolved in all electrolytes, the oxidation state(s) of Mn and Ni were determined to be dependent on the cathode material and independent of cycling potential.

25 ENERGY STORAGE

A Phenazine‐Based Two‐Dimensional Covalent Organic Framework for Photochemical CO 2 Reduction with Increased Selectivity for Two‐Carbon Products

Abstract The reduction of carbon dioxide (CO₂) into valuable products will contribute to sustainable carbon use. Here we report the photocatalytic reduction of CO₂ to carbon monoxide, formate, and oxalate ions using a redox‐active phenazine‐based 2D covalent organic framework (Phen‐COF) and its phenazine monomer. Under similar irradiation conditions,Phen‐COFproduced 2.9 times more CO, 11 times more formate, and 13 times more oxalate compared to equimolar amounts of the monomeric phenazine, demonstrating that the COF architecture enhances catalytic performance (TOF COF : 10 −7 s −1 CO, 10 −8 s −1 formate, and 10 −11 s −1 oxalate). Structural analysis, including X‐ray diffraction and N₂ porosimetry, confirmed the COF's long‐range order and porosity. Mechanistic studies suggest a sequential formate‐to‐oxalate pathway, with CO and formate acting as intermediates. These results demonstrate the potential of the COF architecture to improve the performance of metal‐free, redox‐active aromatic systems such as phenazines to facilitate efficient and selective CO₂ conversion under mild conditions.

Chemistry

Lanthanum-Promoted Electrocatalyst for the Oxygen Evolution Reaction: Unique Catalyst or Oxide Deconstruction?

A conventional performance metric for electrocatalysts that promote the oxygen evolution reaction (OER) is the current density at a given overpotential. However, the assumption that increased current density at lower overpotentials indicates superior catalyst design is precarious for OER catalysts in the working environment, as the crystalline lattice is prone to deconstruction and amorphization, thus greatly increasing the concentration of catalytic active sites. We show this to be the case for La 3+ incorporation into Co 3 O 4 . Powder X-ray diffraction (PXRD), Raman spectroscopy and extended X-ray absorption fine structure (EXAFS) reveal smaller domain sizes with decreased long-range order and increased amorphization for La-modified Co 3 O 4 . This lattice deconstruction is exacerbated under the conditions of OER as indicated by operando spectroscopies. The overpotential for OER decreases with increasing La 3+ concentration, with maximum activity achieved at 17% La incorporation. HRTEM images and electron diffraction patterns clearly show the formation of an amorphous overlayer during OER catalysis that is accelerated with La 3+ addition. O 1s XPS spectra after OER show the loss of lattice-oxide and an increase in peak intensities associated with hydroxylated or defective O-atom environments, consistent with Co(O) x (OH) y species in an amorphous overlayer. Furthermore, our results suggest that improved catalytic activity of oxides incorporated with La 3+ ions (and likely other metal ions) is due to an increase in the number of terminal octahedral Co(O) x (OH) y edge sites upon Co 3 O 4 lattice deconstruction, rather than enhanced intrinsic catalysis.

Catalysts

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

Intensified atomic utilization efficiency of single-atom catalysts for nitrate conversion via electrified nanoporous membrane

Conventional electrochemical reactors for nitrate reduction typically suffer from limited reaction efficiency when applied for real-world water treatment due to poor utilization of electrocatalytic active sites. Here, we applied nanoporous electrofiltration to intensify atomic utilization by incorporating single-atom catalysts into an electrified membrane for reducing low-concentration nitrate to ammonia under realistic water conditions. We enhance the exposure of single atoms in nanopores by coating the catalysts on a carbon nanotube–interwoven membrane framework. Electrofiltration intensifies the transport and adsorption of nitrate in confined nanopores with highly exposed single-atom active sites to enhance reduction. The membrane enables a superior ammonia turnover frequency of 15.1 grams of nitrogen per gram of metal per hour, up to four orders of magnitude higher than that reported in the literature, under both high removal efficiency and Faradaic efficiency of over 86% when treating influents with a low nitrate concentration of 100 milligrams of nitrogen per liter in a residence time on the order of seconds.

Science & Technology - Other Topics