Search NASA⌕ Search

SEARCH · Search NASA

Results for “Activity detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

DETECTION OF COMA ACTIVITY OF THE ACO/QUASI-HILDA OBJECT 212P/2000YN{sub 30}

The quasi-Hilda object 212P/2000YN{sub 30}, which has a cometary-like orbit, was found to display a dust tail structure between 2009 January and March. From orbital calculations, it is shown that this object could have been an active comet in the past before being transported to its current orbital configuration in quasi-stable 3:2 resonance with Jupiter.

79 ASTRONOMY AND ASTROPHYSICS↗

First Measurement of Deeply Virtual Compton Scattering on the Neutron with Detection of the Active Neutron

Measuring deeply virtual Compton scattering (DVCS) on the neutron is one of the necessary steps to understand the structure of the nucleon in terms of generalized parton distributions (GPDs). Neutron targets play a complementary role to transversely polarized proton targets in the determination of the GPD E . This poorly known and poorly constrained GPD is essential to obtain the contribution of the quarks’ angular momentum to the spin of the nucleon. DVCS on the neutron was measured for the first time selecting the exclusive final state by detecting the neutron, using the Jefferson Lab longitudinally polarized electron beam, with energies up to 10.6 GeV, and the CLAS12 detector. The extracted beam-spin asymmetries, combined with DVCS observables measured on the proton, allow a clean quark-flavor separation of the imaginary parts of the Compton form factors H and E . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of a spaceflight-compatible device to perform WBC surface marker staining and whole-blood mitogenic activation for cytokine detection by flow cytometry

Significant changes have recently been described regarding circulating peripheral immune cells immediately following spaceflight. Existing methods for immunophenotype staining of peripheral blood in terrestrial labs do not meet the constraints for flight on the Space Shuttle. We have recently described the development and use of the Whole Blood Staining Device (WBSD), a simple device for staining flow cytometry specimens during spaceflight. When preparing samples with the WBSD, all liquids are safely contained as the cells are moved through staining, lysis and fixation steps. Here we briefly review the use of the WBSD, and then describe another versatile adaptation, a modification to perform intracellular staining of cytokines for detection by flow cytometry. Alterations in cytokine production have been reported both in ground-based simulated microgravity culture and in astronaut samples returning from spaceflight. Data regarding microgravity effects on cytokine production for specific subpopulations of cells is lacking. Flow cytometric cytokine analysis offers the unique ability to perform simultaneous surface marker analysis and positively identity cytokine producing subsets of cells. The utilization of the WBSD provides the ability to perform rapid and routine mitogenic activation during spaceflight coupled with the ability to perform simultaneous surface marker analysis. The only external requirements for this procedure are an in-flight 37-degree incubator and the capacity for 4-degree storage.

NASA Discipline Regulatory Physiology↗

Correlating ethylene glycol reforming activity with in-situ EXAFS detection of Ni segregation in supported NiPt bimetallic catalysts

The structural changes in supported NiPt/C and NiPt/γ-Al2O3 catalysts were investigated using in-situ extended X-ray absorption fine structure (EXAFS) under aqueous phase reforming (APR) of ethylene glycol conditions. Reverse Monte Carlo is introduced to analyze the EXAFS data. Parallel reactor studies of APR of ethylene glycol showed that NiPt catalysts were initially more active than monometallic Pt catalysts. The enhanced activity was correlated to changes in the catalyst structure. Under APR conditions, Ni segregated to the surface of the catalysts, resembling Ni-terminated bimetallic surfaces that were predicted to be more active than Pt from theoretical and experimental studies on model surfaces.

Environmental Molecular Sciences Laboratory↗

Detection of emetic activity in the cat by monitoring venous pressure and audio signals

To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

A Nagahara↗

Potential Activities and Long Lifetimes of Organic Carbon-Degrading Extracellular Enzymes in Deep Subsurface Sediments of the Baltic Sea

Heterotrophic microorganisms in marine sediments produce extracellular enzymes to hydrolyze organic macromolecules, so their products can be transported inside the cell and used for energy and growth. Therefore, extracellular enzymes may mediate the fate of organic carbon in sediments. The Baltic Sea Basin is a primarily depositional environment with high potential for organic matter preservation. The potential activities of multiple organic carbon-degrading enzymes were measured in samples obtained by the International Ocean Discovery Program Expedition 347 from the Little Belt Strait, Denmark, core M0059C. Potential maximum hydrolysis rates (V max ) were measured at depths down to 77.9mbsf for the following enzymes: alkaline phosphatase, β- d -xylosidase, β- d -cellobiohydrolase, N-acetyl-β- d -glucosaminidase, β-glucosidase, α-glucosidase, leucyl aminopeptidase, arginyl aminopeptidase, prolyl aminopeptidase, gingipain, and clostripain. Extracellular peptidase activities were detectable at depths shallower than 54.95mbsf, and alkaline phosphatase activity was detectable throughout the core, albeit against a relatively high activity in autoclaved sediments. β-glucosidase activities were detected above 30mbsf; however, activities of other glycosyl hydrolases (β-xylosidase, β-cellobiohydrolase, N-acetyl-β-glucosaminidase, and α-glucosidase) were generally indistinguishable from zero at all depths. These extracellular enzymes appear to be extremely stable: Among all enzymes, a median of 51.3% of enzyme activity was retained after autoclaving for an hour. We show that enzyme turnover times scale with the inverse of community metabolic rates, such that enzyme lifetimes in subsurface sediments, in which metabolic rates are very slow, are likely to be extraordinarily long. A back-of-the-envelope calculation suggests enzyme lifetimes are, at minimum, on the order of 230days, and may be substantially longer. These results lend empirical support to the hypothesis that a population of subsurface microbes persist by using extracellular enzymes to slowly metabolize old, highly degraded organic carbon.

54 ENVIRONMENTAL SCIENCES↗

Thoron detection with an active Radon exposure meter—First results

For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11 Bq m{sup −3} Radon atmosphere or by a 15 Bq m{sup −3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

54 ENVIRONMENTAL SCIENCES↗

Detection sensitivities in 3-8 MeV neutron activation

Study of detection sensitivities of 73 radioactive elements using fast unmoderated neutrons includes experiments for irradiation, cooling and counting conditions. The gamma ray emission spectra is used to identify the unknown material.

Wahlgren, M. A.↗

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly↗

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly↗

Center of mass detection via an active pixel sensor

An imaging system for identifying the location of the center of mass (COM) in an image. In one aspect, an imaging system includes a plurality of photosensitive elements arranged in a matrix. A center of mass circuit coupled to the photosensitive elements includes a resistive network and a normalization circuit including at least one bipolar transistor. The center of mass circuit identifies a center of mass location in the matrix and includes: a row circuit, where the row circuit identifies a center of mass row value in each row of the matrix and identifies a row intensity for each row; a horizontal circuit, where the horizontal circuit identifies a center of mass horizontal value; and a vertical circuit, where the vertical circuit identifies a center of mass vertical value. The horizontal and vertical center of mass values indicate the coordinates of the center of mass location for the image.

Yadid-Pecht, Orly↗