Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

FY2008 Report on GADRAS Radiation Transport Methods

The primary function of the Gamma Detector Response and Analysis Software (GADRAS) is the solution of inverse radiation transport problems, by which the configuration of an unknown radiation source is inferred from one or more measured radiation signatures. GADRAS was originally developed for the analysis of gamma spectrometry measurements. During fiscal years 2007 and 2008, GADRAS was augmented to implement the simultaneous analysis of neutron multiplicity measurements. This report describes the radiation transport methods developed to implement this new capability. This work was performed at the direction of the National Nuclear Security Administration's Office of Nonproliferation Research and Development. It was executed as an element of the Proliferation Detection Program's Simulation, Algorithm, and Modeling element.

Mattingly, John↗

Generating MCNP Input Files for Unstructured Mesh Geometries

Los Alamos National Laboratory's (LANL) Monte Carlo N-Particle (MCNP) transport code version 6 has the capability for tracking particles on unstructured mesh (UM) geometry models. The MCNP UM feature has been developed for performing calculations of complex geometry models. This capability tracks particles on hybrid geometries where finite element meshes are embedded into constructive solid geometry (CSG) cells. The MCNP UM feature was originally designed to read UM models created by Abaqus/CAE software suite. MCNP versions 6.2.0 and later can process UM models read from Abaqus input les or MCNPUM les converted from Abaqus input les. Sandia National Laboratory's Cubit Toolkit and other finite element analysis software packages may generate UM models and then convert these models into Abaqus input formats.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data, performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully demonstrated. This workflow was run once on the same 96 samples that the group had examined manually and the workflow cycled successfully through all of the samples, collected data from the same samples that were selected manually and located the same peaks of unmodeled density in the resulting difference Fourier maps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

ISAP-MATLAB Package for Sensitivity Analysis of High-Dimensional Stochastic Chemical Networks

Stochastic simulation and modeling play an important role to elucidate the fundamental mechanisms in complex biochemical networks. The parametric sensitivity analysis of reaction networks becomes a powerful mathematical and computational tool, yielding information regarding the robustness and the identifiability of model parameters. However, due to overwhelming computational cost, parametric sensitivity analysis is a extremely challenging problem for stochastic models with a high-dimensional parameter space and for which existing approaches are very slow. Here we present an information-theoretic sensitivity analysis in path-space (ISAP) MATLAB package that simulates stochastic processes with various algorithms and most importantly implements a gradient-free approach to quantify the parameter sensitivities of stochastic chemical reaction network dynamics using the pathwise Fisher information matrix (PFIM; Pantazis, Katsoulakis, and Vlachos 2013). The sparse, block-diagonal structure of the PFIM makes its computational complexity scale linearly with the number of model parameters. As a result of the gradientfree and the sparse nature of the PFIM, it is highly suitable for the sensitivity analysis of stochastic reaction networks with a very large number of model parameters, which are typical in the modeling and simulation of complex biochemical phenomena. Finally, the PFIM provides a fast sensitivity screening method (Arampatzis, Katsoulakis, and Pantazis 2015) which allows it to be combined with any existing sensitivity analysis software.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XScan: An Integrated Tool for Understanding Open Source Community-Based Scientific Code

Many scientific communities have adopted community-based models that integrate multiple components to simulate whole system dynamics. The community software projects’ complexity, stems from the integration of multiple individual software components that were developed under different application requirements and various machine architectures, has become a challenge for effective software system understanding and continuous software development. The paper presents an integrated software toolkit called X-ray Software Scanner (in abbreviation, XScan) for a better understanding of large-scale community-based scientific codes. Our software tool provides support to quickly summarize the overall information of scientific codes, including the number of lines of code, programming languages, external library dependencies, as well as architecture-dependent parallel software features. The XScan toolkit also realizes a static software analysis component to collect detailed structural information and provides an interactive visualization and analysis of the functions. We use a large-scale community-based Earth System Model to demonstrate the workflow, functions and visualization of the toolkit. We also discuss the application of advanced graph analytics techniques to assist software modular design and component refactoring.

Zheng, Weijian↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Deployable Wind-Hybrid Power Systems for Defense and Disaster Response Applications

This report presents an analysis of the performance of deployable energy systems comprised of wind energy systems integrated with diesel generators, photovoltaic systems, and battery storage to meet the load requirements of a representative U.S. Army forward operating base. The analysis is conducted using HOMER, a microgrid analysis software that can search through a wide range of parameters to design and optimize microgrid power systems. The search parameters include the system architecture, the wind and solar resources, and the availability of diesel fuel. The results of the analysis measure the relative performance of the different systems and environments in terms of the overall transportation cost to deploy the system and the ability to provide resilience in terms of meeting mission critical loads.

02 PETROLEUM↗

Improving the Definition of Tumor Bed Boost With the Use of Surgical Clips and Image Registration in Breast Cancer Patients

Purpose: To evaluate the accuracy of a boost technique. Methods and Materials: Twenty-two patients underwent tumorectomy with placement of two or more clips in the surgical cavity before breast remodeling. Preoperative and postoperative computed tomography scans, with match-point registration, were performed on all patients. The relationship between the location of the gross tumor volume (GTV), defined on the preoperative scan, and clip clinical target volume (CTV) (clips with a 5-mm margin on the postoperative scan) was then studied, by use of commercial volume analysis software. Results: Of the patients, 4 had two clips, 2 had three clips, 8 had four clips, and 8 had five clips. The median GTV was 1.06 mL (range, 0.2-5.3 mL); clip CTV ranged from 2.4 to 21.5 mL. Volumetric analysis showed that in 7 cases (32%), there was no intersection between the GTV and the clip CTV, with the following distribution: 4 patients with two clips, 1 patient with three clips, 1 patient with four clips, and 1 patient with five clips. The common contoured volume was defined as the percent ratio between the intersection of the GTV and clip CTV and the GTV. It was found to be significantly increased if three or more clips were used vs. only two clips (common contoured volume, 35.45% vs. 0.73%; p = 0.028). Finally, the GTV and clip CTV volume relationship can be presented as follows: 12.5% to 33% overlap in 8 patients (36.4%), 50% to 75% in 5 patients (22.7%), and greater than 90% in 2 patients (9%). Conclusions: The use of three or more clips during tumorectomy increases the accuracy of tumor bed delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proteomic analysis of astrocytic secretion that regulates neurogenesis using quantitative amine-specific isobaric tagging

Astrocytes are essential components of neurogenic niches that affect neurogenesis through membrane association and/or the release of soluble factors. To identify factors released from astrocytes that could regulate neural stem cell differentiation and proliferation, we used mild oxygen-glucose deprivation (OGD) to inhibit the secretory capacity of astrocytes. Using the Transwell co-culture system, we found that OGD-treated astrocytes could not promote neural stem cell differentiation and proliferation. Next, isobaric tagging for the relative and absolute quantitation (iTRAQ) proteomics techniques was performed to identify the proteins in the supernatants of astrocytes (with or without OGD). Through a multi-step analysis and gene ontology classification, 130 extracellular proteins were identified, most of which were involved in neuronal development, the inflammatory response, extracellular matrix composition and supportive functions. Of these proteins, 44 had never been reported to be produced by astrocytes. Using ProteinPilot software analysis, we found that 60 extracellular proteins were significantly altered (27 upregulated and 33 downregulated) in the supernatant of OGD-treated astrocytes. Among these proteins, 7 have been reported to be able to regulate neurogenesis, while others may have the potential to regulate neurogenesis. This study profiles the major proteins released by astrocytes, which play important roles in the modulation of neurogenesis.

60 APPLIED LIFE SCIENCES↗

New method for analysis of X-ray computed tomography scans of TRISO fuel forms

X-ray computed tomography (XCT) is a powerful characterization tool that has been used for examination of both tristructural-isotropic (TRISO) coated particles and fuel forms. Rapid, nondestructive imaging of complete specimens by XCT provides significant characterization advantages in both speed and comprehensiveness over traditional materialographic methods. This paper discusses a method that has been developed to analyze XCT images of pebble fuel forms containing ~18,000 TRISO particles each. The XCT images are three-dimensional with contrast based on relative x-ray transparency. In the case of TRISO fuel forms, XCT image intensity distinguishes between the high-density kernel, the medium-density SiC, and the low-density matrix and carbon layers. Image analysis software has been developed to process XCT data sets to extract spatial distribution information, including particle nearest-neighbor distances, local packing fraction, and fuel-free zone thickness in TRISO fuel forms. Finally, although this type of high-resolution XCT analysis is likely not feasible as a quality control measurement for commercial TRISO fuel, it is highly useful in generating feedback for the development of fuel form fabrication processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced TidGen Power System - ProteusDS Version 2.43.5 Files

The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. ProteusDS is a full featured dynamic analysis software capable of simulating vessels, structures, lines, and technologies in harsh marine environments. This simulation software that was used to test the Advanced TidGen Power System. This submission includes the supporting Proteus simulation files.

16 TIDAL AND WAVE POWER↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.

25 ENERGY STORAGE↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

Study of Orbitally Excited $B_{(s)}$ Mesons and Evidence for a New $B\pi$ Resonance with the CDF II Detector

This thesis presents an analysis of excited states of B0, B+ and B0 s mesons, decaying to B mesons while emitting a pion or kaon. They are reconstructed from their decay products and a selection is performed to discard wrongly reconstructed B(s) mesons with the multivariate analysis software NeuroBayes, as described in chapter 5. In the training process, the sPlot method and measured and simulated data are used. Chapter 6 describes how the properties of excited B(s) are determined by an unbinned maximum likelihood t to their mass spectra. The systematic uncertainties determined in this analysis are described in chapter 7. The results of this thesis are presented in chapter 8 and a conclusion is given in chapter 9. The results shown in this thesis have been published before in [1].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗